Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 83
Filter
2.
Catheter Cardiovasc Interv ; 98(5): 904-913, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34398509

ABSTRACT

The Society for Cardiovascular Angiography and Interventions (SCAI) Think Tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community annually for high-level field-wide discussions. The 2021 Think Tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease. Each session was moderated by a senior content expert and co-moderated by a member of SCAI's Emerging Leader Mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialog from a broader base, and thereby aid SCAI, the industry community and external stakeholders in developing specific action items to move these areas forward.


Subject(s)
Cardiologists , Cardiology , Heart Defects, Congenital , Angiography , Humans , Treatment Outcome
3.
Catheter Cardiovasc Interv ; 98(5): 950-956, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34227736

ABSTRACT

The aim of the study was to estimate the percentage of Medicare patients needing coronary access for percutaneous coronary intervention (PCI) or coronary angiography following aortic valve replacement (AVR). Indications for TAVR have expanded to include younger and low-risk patients, raising the question of coronary access for future procedures. Medicare patients <80 years old with an AVR between 2011 and 2018 were included. Time-to-event analyses were conducted using Cox hazard models to estimate risk of coronary access up to 7 years after AVR. Model adjustments included age, sex, race, region, comorbidity, concomitant CABG, and smoking. A total of 13,469 Medicare patients (mean age 70.6) met inclusion criteria. Models estimated that 2.5% of patients at 1-year post-index and 17% at over 7 years would need coronary access. For patients who had SAVR (with or without CABG), estimates for coronary access were similar and over 15% after 6.5 years. For TAVR patients, with a previous PCI, 28% at 4.5 years required coronary access, which was higher than TAVR patients without a previous PCI. SAVR patients with and without CAD at baseline were similar; however, TAVR patients with CAD had a 22% rate of coronary access versus 7% for those without at 3 years. Approximately half of patients who needed coronary access returned to the same hospital as their initial AVR. Coronary access is required in a substantial portion of AVR patients especially those with PCI or a history of CAD undergoing TAVR. The need for coronary access may increase as transcatheter AVR becomes accessible to younger patients with a longer life expectancy.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Medicare , Percutaneous Coronary Intervention/adverse effects , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , United States/epidemiology
5.
JACC Cardiovasc Interv ; 14(9): 1009-1018, 2021 05 10.
Article in English | MEDLINE | ID: mdl-33640388

ABSTRACT

OBJECTIVES: The authors sought to determine whether coronary artery tortuosity negatively affects clinical outcomes after stent implantation. BACKGROUND: Coronary artery tortuosity is a common angiographic finding and has been associated with increased rates of early and late major adverse events after balloon angioplasty. METHODS: Individual patient data from 6 prospective, randomized stent trials were pooled. Outcomes at 30 days and 5 years following percutaneous coronary intervention of a single coronary lesion were analyzed according to the presence or absence of moderate/severe vessel tortuosity, as determined by an angiographic core laboratory. The primary endpoint was target vessel failure (TVF) (composite of cardiac death, target vessel-related myocardial infarction [TV-MI], or ischemia-driven target vessel revascularization [ID-TVR]). RESULTS: A total of 6,951 patients were included, 729 of whom (10.5%) underwent percutaneous coronary intervention in vessels with moderate/severe tortuosity. At 30 days, TVF was more frequent in patients with versus without moderate/severe tortuosity (3.8% vs. 2.4%; hazard ratio [HR]: 1.64; 95% confidence interval [CI]: 1.09 to 2.46; p = 0.02), a difference driven by a higher rate of TV-MI. At 5 years, TVF remained increased in patients with moderate/severe tortuosity (p = 0.003), driven by higher rates of TV-MI (p = 0.003) and ID-TVR (p = 0.01). Definite stent thrombosis was also greater in patients with versus without moderate/severe tortuosity (1.9% vs. 1.0%; HR: 1.86; 95% CI: 1.02 to 3.39; p = 0.04). After adjustment for baseline covariates, moderate/severe vessel tortuosity was independently associated with TV-MI and ID-TVR at 5 years (p = 0.04 for both). CONCLUSIONS: Stent implantation in vessels with moderate/severe coronary artery tortuosity is associated with increased rates of TVF due to greater rates of TV-MI and ID-TVR.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Humans , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Risk Factors , Stents , Treatment Outcome
6.
Catheter Cardiovasc Interv ; 96(6): 1258-1265, 2020 11.
Article in English | MEDLINE | ID: mdl-32840956

ABSTRACT

The society for cardiovascular angiography and interventions (SCAI) think tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community for high-level field-wide discussions. The 2020 think tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease (CHD). Each session was moderated by a senior content expert and co-moderated by a member of SCAI's emerging leader mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialogue from a broader base, and thereby aid SCAI and the industry community in developing specific action items to move these areas forward.


Subject(s)
Cardiac Catheterization/trends , Cardiology/trends , Coronary Angiography/trends , Heart Diseases/diagnostic imaging , Heart Diseases/therapy , Percutaneous Coronary Intervention/trends , Diffusion of Innovation , Heart Diseases/physiopathology , Humans
7.
JACC Cardiovasc Interv ; 13(2): 219-231, 2020 01 27.
Article in English | MEDLINE | ID: mdl-31973795

ABSTRACT

OBJECTIVES: This study sought to evaluate the ability of individual markers of frailty to predict outcomes after transcatheter aortic valve replacement (TAVR) and of their discriminatory value in different age groups. BACKGROUND: Appropriate patient selection for TAVR remains a dilemma, especially among the most elderly and potentially frail. METHODS: The study evaluated patients ≥65 years of age in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy registry, linked to Centers for Medicare and Medicaid administrative claims data, receiving elective TAVR from November 2011 to June 2016 (n = 36,242). Indices of frailty included anemia, albumin level, and 5-m walk speed. We performed Cox proportional hazards regression for 30-day and 1-year mortality, adjusting for risk factors known to be predictive of 30-day mortality in the Transcatheter Valve Therapy registry, as well as survival analysis. RESULTS: These indices are independently associated with mortality at 30 days and 1 year and provide incremental value in risk stratification for mortality, with low albumin providing the largest value (hazard ratio: 1.52). Those with low albumin and slower walking speed had longer lengths of stay and higher rates of bleeding and readmission (p < 0.001). Those with anemia also had higher rates of bleeding, readmission, and subsequent myocardial infarction (p < 0.001). CONCLUSIONS: This represents the largest study to date of the role of frailty indices after TAVR, further facilitating robust modeling and adjusting for a large number of confounders. These simple indices are easily attainable, and clinically relevant markers of frailty that may meaningfully stratify patients at risk for mortality after TAVR.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Frail Elderly , Frailty/diagnosis , Geriatric Assessment , Transcatheter Aortic Valve Replacement , Age Factors , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Databases, Factual , Female , Frailty/mortality , Frailty/physiopathology , Hemodynamics , Humans , Male , Predictive Value of Tests , Registries , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United States
8.
Cardiovasc Revasc Med ; 21(3): 263-270, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31255552

ABSTRACT

BACKGROUND: Predictors of hospital readmissions and tools to predict readmissions after TAVR are scarce. Our objective was to identify predictors of early hospital readmission following TAVR in contemporary clinical practice and develop a risk calculator. METHODS: Patients with a contemporary self-expanding TAVR between 2015 and 2017 in the STS/ACC/TVT Registry™ database were included. Patients were divided into a derivation and validation cohort (2:1). A risk score was calculated using the derivation cohort based on multivariable predictors of 30-day unplanned readmissions and applied to the validation cohort. RESULTS: A total of 10,345 TAVR patients at 350 centers were included. Unplanned 30-day hospital readmission was 9.2%. Patients with an early readmission had higher 30-day rates for mortality (2.3% vs. 0.8%, p ≪ 0.001), stroke (4.1% vs. 2.7% p = 0.009), major vascular complications (2.0% vs. 1.0%, p = 0.003) and new pacemaker implantation (25.7% vs. 18.6%, p ≪ 0.001). Multivariable predictors of 30-day readmission included diabetes, atrial fibrillation, advanced heart failure symptoms, home oxygen, decreased 5-m gait speed or the inability to walk, serum creatinine ≫1.6 mg/dL, index hospitalization length of stay ≫5 days, major vascular complication and ≥ moderate post-procedure aortic or mitral valve regurgitation. Based on these predictors, we stratified 30-day readmission risk into low-, moderate- and high-risk subsets. There was a 2.5× difference in readmission rates between the low- (5.8%) and high-risk subsets (14.6%). CONCLUSION: We stratified the risk of early hospital readmission after TAVR based on a simple scoring system. This score may improve discharge planning centered on the individual's readmission risk. SUMMARY: Unplanned readmissions in the United States are prevalent and costly accounting for $41.3 billion in annual hospital payments and are associated with adverse clinical outcomes. We found that diabetes, atrial fibrillation, advanced heart failure symptoms, home oxygen, frailty, acute kidney injury, prolonged hospitalization, major vascular complications, and moderate or worse post-procedure aortic or mitral valve regurgitation predicted of 30-day readmission following self-expanding TAVR. This information may improve discharge planning centered on each patient's readmission risk.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Heart Failure , Mitral Valve Insufficiency , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Oxygen , Patient Readmission , Registries , Risk Factors , Treatment Outcome , United States/epidemiology
9.
Circ Cardiovasc Interv ; 12(10): e008155, 2019 10.
Article in English | MEDLINE | ID: mdl-31607151

ABSTRACT

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (TAVR) is an option when a surgical valve demonstrates deterioration and dysfunction. This study reports 3-year results following valve-in-valve with self-expanding TAVR. METHODS: The CoreValve US Expanded Use Study is a prospective, nonrandomized, single-arm study that evaluates safety and effectiveness of TAVR in extreme risk patients with symptomatic failed surgical biologic aortic valves. Study end points include all-cause mortality, need for valve reintervention, hemodynamic changes over time, and quality of life through 3 years. Patients were stratified by presence of preexisting surgical valve prosthesis-patient mismatch. RESULTS: From March 2013 to May 2015, 226 patients deemed extreme risk (STS-PROM [Society of Thoracic Surgeons Predicted Risk of Mortality] 9.0±7%) had attempted valve-in-valve TAVR. Preexisting surgical valve prosthesis-patient mismatch was present in 47.2% of the cohort. At 3 years, all-cause mortality or major stroke was 28.6%, and 93% of patients were in New York Heart Association I or II heart failure. Valve performance was maintained over 3 years with low valve reintervention rates (4.4%), an improvement in effective orifice area over time and a 2.7% rate of severe structural valve deterioration. Preexisting severe prosthesis-patient mismatch was not associated with 3-year mortality but was associated with significantly less improvement in quality of life at 3-year follow-up (P=0.01). CONCLUSIONS: Self-expanding TAVR in patients with failed surgical bioprostheses at extreme risk for surgery was associated with durable hemodynamics and excellent clinical outcomes. Preexisting surgical valve prosthesis-patient mismatch was not associated with mortality but did limit patient improvement in quality of life over 3-year follow-up. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01675440.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Prosthesis Failure , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Bioprosthesis , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Hemodynamics , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Quality of Life , Recovery of Function , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
10.
Am J Cardiol ; 124(7): 1091-1098, 2019 10 01.
Article in English | MEDLINE | ID: mdl-31362879

ABSTRACT

Transcatheter aortic valve implantation with a bioprosthetic valve of insufficient size is associated with a higher risk of aortic regurgitation (AR). The 31-mm CoreValve and the next generation 34-mm Evolut R bioprostheses were designed to address the need for larger diameter aortic annuli. This analysis examined the clinical and hemodynamic outcomes following commercial transcatheter aortic valve implantation with the 31-mm CoreValve and 34-mm Evolut R in the Society of Thoracic Surgeons/the American College of Cardiology Transcatheter Valve Therapy Registry. Patients receiving a 31-mm CoreValve or 34-mm Evolut R valve for symptomatic severe native aortic stenosis from January 2014 to September 2017 in the Transcatheter Valve Therapy Registry underwent propensity score matching using baseline demographics, clinical and frailty measures, and procedural variables. Procedural characteristics, in-hospital and 30-day clinical and echocardiographic outcomes were compared. Of 4545 patients implanted with a 31-mm CoreValve and 3036 patients with a 34-mm Evolut R valve, matching resulted in 1813 patient sets. Most patients were male (>92%), elderly (∼80 years) with the Society of Thoracic Surgeons score of 6.6%. Use of the 34-mm versus 31-mm valve resulted in shorter median procedural time (113.0 [85.0, 150.0] vs 93.0 [71.0, 126.0] min, p <0.001), higher device success (98.1% vs 93.9%, p <0.001), fewer pacemakers (16.7% vs 24.6%, p <0.001), less ≥moderate AR with the 34-mm (5.5% vs 13.7%), p <0.001) and shorter hospital stay (3.0 [2.0, 4.0] vs 4.0 [3.0, 6.0] days, p <0.001). In conclusion, this largest experience with the 34-mm Evolut R valve showed higher device success, reduced hospital stay, lower pacemaker rates and less ≥moderate AR compared with the 31-mm CoreValve bioprosthesis.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Bioprosthesis , Heart Valve Prosthesis , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Echocardiography , Female , Humans , Length of Stay , Male , Postoperative Complications/diagnostic imaging , Propensity Score , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome
11.
Am J Cardiol ; 124(5): 781-788, 2019 09 01.
Article in English | MEDLINE | ID: mdl-31311661

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is approved for treatment of symptomatic aortic stenosis in patients at increased risk for surgical valve replacement, but outcomes data in patients with severe native aortic regurgitation (AR) treated with TAVI remain limited. The objective of this analysis was to evaluate outcomes among patients identified in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry who underwent TAVI for native AR with a commercially available self-expanding valve system. From January 2014 to December 2017, 230 patients in the TVT Registry underwent TAVI for primary severe native AR using a commercially available self-expanding valve (n = 81, CoreValve; n = 149, Evolut R). For inclusion, AR was either pure or mixed with predominantly moderate/severe AR and mean aortic valve gradient ≤20 mm Hg. Thirty-day outcomes were evaluated using time-to-event methods. Device success was reported in 81.7% of patients (CoreValve, 72.2%; Evolut R, 86.9%; p = 0.0.01). Thirty-day all-cause mortality was 13.3%. All patients presented with moderate/severe AR at baseline; at 30 days, 9.1% of implanted patients with data continued to have moderate and 1.4% severe AR. There was a significant reduction in residual moderate/severe AR from the CoreValve to Evolut R device (19.1% vs 6.3%, p = 0.02). Multivariable analysis revealed factors associated with 30-day all-cause mortality include number of valves used (hazard ratio [HR] 2.361, 1.643 to 3.391, p <0.001), albumin < 3.3 mg/dL (HR 3.358, 1.551 to 7.273, p=0.002), and left ventricular ejection fraction (HR 0.978, 0.957 to 1.000, p = 0.047). Despite higher 30-day all-cause mortality, self-expanding TAVI may be an option in selected patients with AR who have no surgical options.


Subject(s)
Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/surgery , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Insufficiency/diagnostic imaging , Cause of Death , Female , Hospital Mortality/trends , Humans , Male , Multivariate Analysis , Prognosis , Proportional Hazards Models , Prosthesis Design , Retrospective Studies , Risk Assessment , Survival Rate , Treatment Outcome
12.
Am Heart J ; 211: 45-53, 2019 05.
Article in English | MEDLINE | ID: mdl-30831333

ABSTRACT

The Amulet IDE Trial is an ongoing, prospective, randomized, multi-national trial, designed to evaluate the safety and effectiveness of the AMPLATZER Amulet Left Atrial Appendage Occluder for stroke prevention in comparison to the WATCHMAN Left Atrial Appendage Closure Device in patients with non-valvular atrial fibrillation. METHODS: Non-valvular atrial fibrillation patients at high risk of stroke (CHADS2 score ≥2 or a CHA2DS2-VASc score of ≥3) who are suitable candidates for left atrial appendage occlusion (LAAO) will be fully informed and requested to participate in the trial. A total of 1878 patients at up to 150 sites worldwide will be randomized in a 1:1 ratio between the AMPLATZER Amulet device (investigational) and the Boston Scientific WATCHMAN device (control). Each patient will be followed for 5 years, with follow-up assessments at discharge, 45 days, 3, 6, 9, 12, 18, and 24 months and then annually. The trial has three primary endpoints: A composite of procedure-related complications, or all-cause death, or major bleeding through 12 months (safety); a composite of ischemic stroke or systemic embolism through 18 months (effectiveness); and effective device LAAO, defined as residual jet around the device ≤5 mm at the 45-day visit (mechanism of action). SUMMARY: The Amulet IDE Trial is the first randomized head-to-head LAAO device trial and will provide data for the AMPLATZER Amulet occluder in a population with a high risk of stroke and bleeding.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Surgical Procedures/instrumentation , Septal Occluder Device , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Atrial Fibrillation/complications , Cardiac Catheterization , Cardiac Surgical Procedures/adverse effects , Cause of Death , Fibrinolytic Agents/adverse effects , Fibrinolytic Agents/therapeutic use , Hemorrhage/chemically induced , Hemorrhage/prevention & control , Humans , Postoperative Complications , Prospective Studies , Prosthesis Design , Risk Factors , Septal Occluder Device/adverse effects , Stroke/etiology , Stroke/prevention & control
13.
Heart ; 105(21): 1622-1628, 2019 11.
Article in English | MEDLINE | ID: mdl-30077993

ABSTRACT

OBJECTIVES: This study evaluates the 5-year clinical outcomes of transcatheter mitral valve (MV) repair with the MitraClip device in patients at high risk for MV surgery treated in the Endovascular Valve Edge-to-Edge Repair (EVEREST) II High Risk Study (HRS). METHODS: Patients with mitral regurgitation (MR) 3+ or 4+ and predicted surgical mortality risk ≥12% or surgeon assessment based on prespecified high-risk factors were enrolled. Patients prospectively consented to 5 years of follow-up. RESULTS: At 5 years, clinical follow-up was achieved in 90% of 78 enrolled patients. The rate of postprocedural adverse events declined from 30 days to 1 year follow-up and was stable thereafter through 5 years. Two patients (2.6%) developed mitral stenosis (MS). Two patients underwent MV surgery, including one due to MS. A total of 42 deaths were reported through 5 years. Effectiveness measures at 5 years showed reductions in MR severity to ≤2+ in 75% of patients (p=0.0107), left ventricular (LV) end-diastolic volume (-38.2 mL; 95% CI -55.0 to -21.4; p<0.0001) and LV end-systolic volume (-14.6 mL; 95% CI -27.7 to -1.5; p=0.0303) compared with baseline. The New York Heart Association (NYHA) functional class improved from baseline to 5 years (p<0.005), and septal-lateral annular dimensions remained stable with no indication of mitral annular dilation through 5 years. CONCLUSIONS: The EVEREST II HRS demonstrated long-term safety and efficacy of MitraClip in high-surgical-risk patients through 5 years. The observed mortality was most likely a consequence of the advanced age and comorbidity profile of the enrolled patients, while improvements in NYHA class in surviving patients were durable through long-term follow-up. TRIAL REGISTRATION NUMBER: NCT01940120.


Subject(s)
Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Heart Ventricles/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Postoperative Complications/epidemiology , Risk Assessment/methods , Aged , Echocardiography , Female , Follow-Up Studies , Heart Ventricles/diagnostic imaging , Humans , Incidence , Male , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/mortality , Prospective Studies , Risk Factors , Severity of Illness Index , Survival Rate/trends , Time Factors , United States/epidemiology , Ventricular Function, Left/physiology
14.
JAMA Cardiol ; 3(12): 1151-1159, 2018 12 01.
Article in English | MEDLINE | ID: mdl-30476950

ABSTRACT

Importance: Improvements in symptoms, functional capacity, and quality of life are among the key goals of edge-to-edge transcatheter mitral valve repair (TMVR) for mitral regurgitation. Objective: To examine health status outcomes among patients undergoing TMVR in clinical practice and the factors associated with improvement. Design, Setting, and Participants: This cohort study used the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry, which contains data on patients with severe mitral regurgitation treated with TMVR from 2013 through 2017 in 217 US hospitals. Main Outcomes and Measures: Change in disease-specific health status (Kansas City Cardiomyopathy Questionnaire-Overall Summary score [KCCQ-OS]; range 0-100 points, with higher scores indicating better health status) at 30 days and 1 year after TMVR. We also examined factors associated with health status at 30 days after TMVR, by means of multivariable linear regression using a generalized estimating equations approach to account for clustering of patients within sites. Results: The KCCQ data were available in 81.2% at baseline, 69.3% of survivors at 30 days, and 47.4% of survivors at 1 year. Among 4226 patients who underwent TMVR, survived 30 days, and completed the KCCQ at baseline and follow-up, the KCCQ-OS increased from 41.9 before TMVR to 66.7 at 30 days (mean change 24.8 [95% CI, 24.0-25.6] points; P < .001), representing a large clinical improvement. The KCCQ scores remained stable from 30 days to 1 year after TMVR, with no further significant increase or decline. On multivariable analysis, atrial fibrillation (-2.2 [95% CI, -3.7 to -0.6] points; P = .01), permanent pacemaker (-2.1 [95% CI, -3.7 to -0.4] points; P = .01), severe lung disease (-3.9 [95% CI, -6.2 to -1.5] points; P = .001), home oxygen (-2.7 [95% CI, -4.9 to -0.4] points; P = .02), and lower KCCQ scores at baseline (3.9 points for each 10-point increase [95% CI, 3.6-4.2]; P < .001) were independently associated with lower 30-day KCCQ-OS scores. In-hospital renal failure was uncommon but was also associated with significant reductions in 30-day KCCQ-OS scores (-7.3 [95% CI -13.3 to -1.2] points). In estimates calculated with inverse probability weighting, after 1 year after TMVR, 54.2% (95% CI 52.2%-56.1%) of patients were alive and well; 23.0% had died, 21.9% had persistently poor health status (KCCQ-OS <60 points), 5.5% had a health status decline from baseline, and 4.6% had both poor health status and health status decline. Conclusions and Relevance: In a national cohort of US patients undergoing edge-to-edge TMVR in clinical practice, health status was impaired prior to the procedure, improved within 30 days, and remained stable through 1 year among surviving patients with available data. While long-term mortality remains high, most surviving patients demonstrate improvements in symptoms, functional status, and quality of life, with only modest differences by patient-level factors.


Subject(s)
Cardiac Catheterization/methods , Health Status , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Quality of Life , Registries , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Mitral Valve Insufficiency/psychology , Retrospective Studies , Time Factors , Treatment Outcome
15.
J Am Coll Cardiol ; 72(22): 2687-2696, 2018 12 04.
Article in English | MEDLINE | ID: mdl-30249462

ABSTRACT

BACKGROUND: The CoreValve U.S. Pivotal High Risk Trial was the first randomized trial to show superior 1-year mortality of transcatheter aortic valve replacement (TAVR) compared with surgical aortic valve replacement (SAVR) among high operative mortality-risk patients. OBJECTIVES: The authors sought to compare TAVR to SAVR for mid-term 5-year outcomes of safety, performance, and durability. METHODS: Surgical high-risk patients were randomized (1:1) to TAVR with the self-expanding bioprosthesis or SAVR. VARC-1 (Valve Academic Research Consortium I) definitions were applied. Severe hemodynamic structural valve deterioration was defined as a mean gradient ≥40 mm Hg or a change in gradient ≥20 mm Hg or new severe aortic regurgitation. Five-year follow-up was planned. RESULTS: A total of 797 patients were randomized at 45 U.S. centers, of whom 750 underwent an attempted implant (TAVR = 391, SAVR = 359). The overall mean age was 83 years, and the STS score was 7.4%. All-cause mortality rates at 5 years were 55.3% for TAVR and 55.4% for SAVR. Subgroup analysis showed no differences in mortality. Major stroke rates were 12.3% for TAVR and 13.2% for SAVR. Mean aortic valve gradients were 7.1 ± 3.6 mm Hg for TAVR and 10.9 ± 5.7 mm Hg for SAVR. No clinically significant valve thrombosis was observed. Freedom from severe SVD was 99.2% for TAVR and 98.3% for SAVR (p = 0.32), and freedom from valve reintervention was 97.0% for TAVR and 98.9% for SAVR (p = 0.04). A permanent pacemaker was implanted in 33.0% of TAVR and 19.8% of SAVR patients at 5 years. CONCLUSIONS: This study shows similar mid-term survival and stroke rates in high-risk patients following TAVR or SAVR. Severe structural valve deterioration and valve reinterventions were uncommon. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902).


Subject(s)
Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/surgery , Self Expandable Metallic Stents/trends , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Aortic Valve Insufficiency/diagnosis , Cohort Studies , Female , Follow-Up Studies , Humans , Male , Mortality/trends , Prospective Studies , Risk Factors , Self Expandable Metallic Stents/adverse effects , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
16.
Curr Cardiol Rep ; 20(10): 101, 2018 09 01.
Article in English | MEDLINE | ID: mdl-30173390

ABSTRACT

PURPOSE: This paper reviews the double-kiss crush (DK crush) technique in coronary artery bifurcation lesions. The technical aspects of the procedure and the clinical data supporting its use are summarized. RECENT FINDINGS: Randomized studies support the adoption of DK technique in complex bifurcation lesions for both left main and non-left-main lesions. For true bifurcation lesions, DK crush may become the default technique for lesions in which the side-branch disease is complex and long. Optimal technique is essential for obtaining the clinical outcomes noted in the DKCRUSH randomized studies.


Subject(s)
Coronary Artery Disease/surgery , Percutaneous Coronary Intervention/methods , Stents , Angioplasty, Balloon, Coronary/methods , Coronary Angiography , Coronary Restenosis/surgery , Coronary Stenosis/surgery , Drug-Eluting Stents , Humans , Myocardial Infarction/surgery , Myocardial Revascularization , Randomized Controlled Trials as Topic , Time Factors , Treatment Outcome
17.
Am J Cardiol ; 121(11): 1358-1364, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29680171

ABSTRACT

The impact of predilatation (Pre-Dil) on prosthesis hemodynamics and clinical outcomes of subjects who underwent transcatheter aortic valve implantation (TAVI) with a self-expanding prosthesis remains unclear. Two thousand seven hundred twenty-one subjects from the extreme- and high-risk CoreValve Continued Access Study (CAS) were included in the analysis. Subjects who underwent Pre-Dil before TAVI were compared with subjects who underwent TAVI without Pre-Dil. Clinical outcomes included death, stroke, myocardial infarction, acute kidney injury, and new permanent pacemaker implantation. Serial echocardiograms were analyzed to evaluate prosthesis hemodynamics, specifically paravalvular regurgitation, effective orifice area, and mean gradient. Two thousand one hundred eighteen and 603 subjects underwent TAVI with and without Pre-Dil, respectively. Subjects in the Pre-Dil cohort were more commonly male, while subjects in the no Pre-Dil cohort had higher rates of previous stroke and lower mean aortic valve gradients. Outcomes at 30 days were comparable between Pre-Dil and no Pre-Dil subjects, with no significant difference in mortality (5.5% vs 4.3%, p = 0.27), major stroke (2.6% vs 2.2%, p = 0.54), major vascular complications (6.9% vs 8.0%, p = 0.37), major bleeding (24.4% vs 26.1%, p = 0.40), and permanent pacemaker implantation (21.3% vs 23.4%, p = 0.36). There were no significant differences in the same outcomes at 12 months. Effective orifice area and mean gradient were comparable between Pre-Dil and no-Pre-Dil subjects at discharge, at 30 days, and at 12 months. In conclusion, when performing TAVI with the self-expanding CoreValve device, performing direct implantation without Pre-Dil maintains an acceptable safety profile and still achieves desired and consistent prosthesis hemodynamics.


Subject(s)
Aortic Valve Stenosis/surgery , Dilatation/methods , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/methods , Acute Kidney Injury/epidemiology , Aged , Aged, 80 and over , Bundle-Branch Block/epidemiology , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial , Echocardiography , Female , Hemodynamics , Humans , Male , Mortality , Myocardial Infarction/epidemiology , Pacemaker, Artificial , Severity of Illness Index , Stroke/epidemiology , Treatment Outcome
18.
J Thorac Cardiovasc Surg ; 153(6): 1293-1301.e1, 2017 06.
Article in English | MEDLINE | ID: mdl-28249691

ABSTRACT

OBJECTIVE: Explore causes and timing of death from the CoreValve US Pivotal High-Risk Trial. METHODS: An independent clinical events committee adjudicated causes of death, followed by post hoc hierarchical classification. Baseline characteristics, early outcomes, and causes of death were evaluated for 3 time periods (selected based on threshold of surgical 30-day mortality and on the differences in the continuous hazard between the 2 groups): early (0-30 days), recovery (31-120 days), and late (121-365 days). RESULTS: Differences in the rate of death were evident only during the recovery period (31-120 days), whereas 15 patients undergoing transcatheter aortic valve replacement (TAVR) (4.0%) and 27 surgical aortic valve replacement (SAVR) patients (7.9%) died (P = .025). This mortality difference was largely driven by higher rates of technical failure, surgical complications, and lack of recovery following surgery. From 0 to 30 days, the causes of death were more technical failures in the TAVR group and lack of recovery in the SAVR group. Mortality in the late period (121-365 days) in both arms was most commonly ascribed to other circumstances, comprising death from medical complications from comorbid disease. CONCLUSIONS: Mortality at 1 year in the CoreValve US Pivotal High-Risk Trial favored TAVR over SAVR. The major contributor was that more SAVR patients died during the recovery period (31-121 days), likely affected by the overall influence of physical stress associated with surgery. Similar rates of technical failure and complications were observed between the 2 groups. This suggests that early TAVR results can improve with technical refinements and that high-risk surgical patients will benefit from reducing complications.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/mortality , Multicenter Studies as Topic/methods , Randomized Controlled Trials as Topic/methods , Research Design , Transcatheter Aortic Valve Replacement/mortality , Aged , Aged, 80 and over , Animals , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Cause of Death , Comorbidity , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Postoperative Complications/mortality , Risk Assessment , Risk Factors , Severity of Illness Index , Sus scrofa , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , United States
20.
Coron Artery Dis ; 28(1): 77-89, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27561169

ABSTRACT

Although current everolimus-eluting coronary stents have shown improved event-free survival within the first year following implantation compared with bare-metal stents or earlier generation drug-eluting stents, they remain associated with an ongoing risk for adverse outcomes (thrombosis, myocardial infarction, and restenosis) beyond 1 year at rates similar to those observed following bare-metal stent deployment. This ongoing very late hazard has been attributed to the permanent presence of the metal frame and/or polymer in these stents. The Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) has been developed to provide mechanical support and drug-delivery functions similar to metallic drug-eluting stents, followed by complete resorption with recovery of more normal vascular structure and function, thus avoiding the limitations associated with permanent metallic endovascular prostheses. Absorb BVS has shown safety and efficacy in the dedicated clinical trial development program of Abbott Vascular and in an array of investigator-sponsored studies involving a broad spectrum of clinical (patient) as well as coronary anatomic complexity. Longer-term evidence, largely limited to single-arm studies, appears to reflect durable safety and efficacy and suggests Absorb BVS to be an attractive therapeutic option. Interim evidence from a series of randomized-clinical trials (RCTs) comparing Absorb BVS with the Xience cobalt-chromium metallic everolimus-eluting stent has shown noninferiority of Absorb BVS with respect to target lesion failure (composite occurrence of cardiac death, target vessel-related myocardial infarction, and ischemia-driven target lesion revascularization) beyond the first year, with no statistically significant differences in other safety/efficacy measures. However, concerns do exist in terms of increased rates of scaffold thrombosis, the risk for which may be mitigated by improved patient and lesion selection, procedural technique, and device iteration. We provide an overview of the evolution of percutaneous coronary intervention, in-vivo characterization of Absorb BVS resorption, and a summary with a critical evaluation of available evidence from RCTs, pooled analyses, and meta-analyses of RCTs for the safety and efficacy of Absorb BVS obtained primarily following the treatment of noncomplex coronary lesions in patients with stable ischemic heart disease and/or stabilized acute coronary syndromes.


Subject(s)
Absorbable Implants , Coronary Artery Disease/therapy , Percutaneous Coronary Intervention/instrumentation , Randomized Controlled Trials as Topic , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Restenosis/etiology , Coronary Stenosis/etiology , Evidence-Based Medicine , Humans , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL