Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
J Clin Med ; 13(18)2024 Sep 20.
Article in English | MEDLINE | ID: mdl-39337062

ABSTRACT

Objectives: To assess the impact of an Artificial Intelligence (AI) limb bone fracture diagnosis software (AIS) on emergency department (ED) workflow and diagnostic accuracy. Materials and Methods: A retrospective study was conducted in two phases-without AIS (Period 1: 1 January 2020-30 June 2020) and with AIS (Period 2: 1 January 2021-30 June 2021). Results: Among 3720 patients (1780 in Period 1; 1940 in Period 2), the discrepancy rate decreased by 17% (p = 0.04) after AIS implementation. Clinically relevant discrepancies showed no significant change (-1.8%, p = 0.99). The mean length of stay in the ED was reduced by 9 min (p = 0.03), and expert consultation rates decreased by 1% (p = 0.38). Conclusions: AIS implementation reduced the overall discrepancy rate and slightly decreased ED length of stay, although its impact on clinically relevant discrepancies remains inconclusive. Key Point: After AI software deployment, the rate of radiographic discrepancies decreased by 17% (p = 0.04) but this was not clinically relevant (-2%, p = 0.99). Length of patient stay in the emergency department decreased by 5% with AI (p = 0.03). Bone fracture AI software is effective, but its effectiveness remains to be demonstrated.

2.
Eur Radiol ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39012527

ABSTRACT

BACKGROUND: The last decade has seen a surge in the demand for imaging exams in emergency radiology (ER), necessitating an evolution in organizational systems for departments offering round-the-clock care, while safeguarding patient care quality and physician well-being to prevent burnout. PURPOSE: To develop a nationwide overview of ER organizations in France and identify structures that promote job satisfaction. MATERIAL AND METHODS: Two surveys were sent to 709 radiological centers across France from March to June 2022, inquiring about organizational aspects and quality of life (QOL), incorporating four validated QOL questionnaires. The organization of each center was mapped, and correlations between respondent characteristics and mental health were analyzed using Pearson's and Wilcoxon tests. RESULTS: A total of 284 centers answered the organizational survey, with a response rate of about 41.6%. Among them, there were 32 university hospitals, 208 general hospitals, 2 teaching army hospitals, and 42 private facilities. Of these, night-time operations showed 14% on-site coverage, 12% on-call from home, 69% utilized external teleradiology, and 4% used in-house teleradiology. These trends persisted over weekends and holidays. Regarding the quality of working life, academic, general, and private radiologists are more satisfied with their practice compared to trainees. Depersonalization, part of the three dimensions of burnout, was high in every class, at 60% (n = 210/350). CONCLUSION: Outside of university hospitals, most radiology centers in France no longer have on-site radiologists during off hours. Residents are prone to lower job satisfaction and quality of life than more experienced radiologists. CLINICAL RELEVANCE STATEMENT: The survey illustrates how French ER is structured, pointing out the escalating significance of teleradiology and noting that radiologists generally experience high job satisfaction while also confronting typical organizational challenges. KEY POINTS: The need for continuous radiology coverage comes with unique logistical challenges, especially in ER. Night shifts show a significant reliance on teleradiology services, especially by external companies. Pay, shift patterns, and seniority affect the well-being of emergency radiologists, particularly the residents.

3.
J Clin Med ; 13(13)2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38999213

ABSTRACT

Purpose: We aimed to evaluate whether virtual non-contrast cerebral computed tomography (VNCCT) reconstructed from intravenous contrast-enhanced dual-energy CT (iv-DECT) could replace non-contrast CT (NCCT) in patients with suspected acute cerebral ischemia. Method: This retrospective study included all consecutive patients in whom NCCT followed by iv-DECT were performed for suspected acute ischemia in our emergency department over a 1-month period. The Alberta Stroke Program Early CT Score (ASPECTS) was used to determine signs of acute ischemia in the anterior and posterior circulation, the presence of hemorrhage, and alternative findings, which were randomly evaluated via the consensus reading of NCCT and VNCCT by two readers blinded to the final diagnosis. An intraclass correlation between VNCCT and NCCT was calculated for the ASPECTS values. Both techniques were evaluated for their ability to detect ischemic lesions (ASPECTS <10) when compared with the final discharge diagnosis (reference standard). Results: Overall, 148 patients (80 men, mean age 64 years) were included, of whom 46 (30%) presented with acute ischemia, 6 (4%) presented with intracerebral hemorrhage, 11 (7%) had an alternative diagnosis, and 85 (59%) had no pathological findings. The intraclass correlation coefficients of the two modalities were 0.97 (0.96-0.98) for the anterior circulation and 0.77 (0.69-0.83) for the posterior circulation. The VNCCT's sensitivity for detecting acute ischemia was higher (41%, 19/46) than that of NCCT (33%, 15/46). Specificity was similar between the two techniques, at 94% (97/103) and 98% (101/103), respectively. Conclusions: Our results show that VNCCT achieved a similar diagnostic performance as NCCT and could, thus, replace NCCT in assessing patients with suspected acute cerebral ischemia.

5.
Eur Radiol ; 34(10): 6885-6895, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38494526

ABSTRACT

OBJECTIVES: The aim of the IRECAP study was to evaluate the rate of locally advanced pancreas cancer patients (LAPC) who could undergo R0 or R1 surgery after irreversible electroporation (IRE). MATERIALS AND METHODS: IRECAP study is a phase II, single-center, open-label, prospective, non-randomized trial registered at clinicaltrials.gov (NCT03105921). Patients with LAPC were first treated by 3-month neo-adjuvant chemotherapy in order to avoid inclusion of either patients with LAPC having become resectable after chemotherapy or patients with rapid disease progression. In cases of stable disease, IRE was performed percutaneously under CT guidance. Surgery was planned between 28 and 90 days after IRE. Tumor specimens were studied to evaluate the resection margins (R0/R1/R2). RESULTS: Six men and 11 women were included (median age 61 years, range 37-77 years). No IRE-related death was observed. Ten patients (58%, 10/17) experienced 25 serious adverse events related to IRE. Four patients progressed between IRE and surgery and were excluded from surgery. Thirteen patients were finally operated, six withheld for pancreas resection, three for diffuse peritoneal carcinosis, two for massive vascular entrapment, and one for hepato-cellular carcinoma not diagnosed before surgery. Rate of R1-R0 was 35% (n = 6/17). Median overall survival was 31 months (95% CI; 4-undefined) for the six patients with R0/R1 resection and 21 months (95% CI; 4-25) for the 11 patients without resection or R2 resection (logrank p = 0.044). CONCLUSION: After neoadjuvant chemotherapy, IRE could provide R0 or R1 resection in 35% of LAPC, which seems to be associated with higher OS. CLINICAL RELEVANCE STATEMENT: After induction chemotherapy, stable locally advanced pancreatic cancers can be treated by irreversible electroporation, which could lead to a secondary 35% rate of R0 or R1 surgical resection which may be associated with a significantly higher overall survival. KEY POINTS: • In cases of unresectable LAPC (locally advanced pancreatic cancer), percutaneous irreversible electroporation (pIRE) is feasible (100% success rate of the procedure), but is associated with a 58% rate of grade 3-4 adverse events. • In patients with unresectable LAPC, pIRE could lead 35% of patients to R0-R1 surgical resection. • From IRE, median overall survival was 31 months (95% CI; 4-undefined) for the patients with R0/R1 resection and 21 months (95% CI; 4-25) for the patients without resection or R2 resection (logrank p = 0.044).


Subject(s)
Adenocarcinoma , Electroporation , Pancreatic Neoplasms , Humans , Pancreatic Neoplasms/surgery , Pancreatic Neoplasms/therapy , Male , Female , Middle Aged , Aged , Electroporation/methods , Adult , Prospective Studies , Adenocarcinoma/surgery , Adenocarcinoma/therapy , Neoadjuvant Therapy/methods , Treatment Outcome
6.
J Vasc Surg ; 79(6): 1390-1400.e8, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38325564

ABSTRACT

OBJECTIVE: This study aims to evaluate a fully automatic deep learning-based method (augmented radiology for vascular aneurysm [ARVA]) for aortic segmentation and simultaneous diameter and volume measurements. METHODS: A clinical validation dataset was constructed from preoperative and postoperative aortic computed tomography angiography (CTA) scans for assessing these functions. The dataset totaled 350 computed tomography angiography scans from 216 patients treated at two different hospitals. ARVA's ability to segment the aorta into seven morphologically based aortic segments and measure maximum outer-to-outer wall transverse diameters and compute volumes for each was compared with the measurements of six experts (ground truth) and thirteen clinicians. RESULTS: Ground truth (experts') measurements of diameters and volumes were manually performed for all aortic segments. The median absolute diameter difference between ground truth and ARVA was 1.6 mm (95% confidence interval [CI], 1.5-1.7; and 1.6 mm [95% CI, 1.6-1.7]) between ground truth and clinicians. ARVA produced measurements within the clinical acceptable range with a proportion of 85.5% (95% CI, 83.5-86.3) compared with the clinicians' 86.0% (95% CI, 83.9-86.0). The median volume similarity error ranged from 0.93 to 0.95 in the main trunk and achieved 0.88 in the iliac arteries. CONCLUSIONS: This study demonstrates the reliability of a fully automated artificial intelligence-driven solution capable of quick aortic segmentation and analysis of both diameter and volume for each segment.


Subject(s)
Aortography , Computed Tomography Angiography , Deep Learning , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Humans , Reproducibility of Results , Female , Male , Aged , Middle Aged , Automation , Retrospective Studies , Aged, 80 and over , Datasets as Topic , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery
7.
J Clin Med ; 12(24)2023 Dec 15.
Article in English | MEDLINE | ID: mdl-38137775

ABSTRACT

Glial tumors represent the leading etiology of primary brain tumors. Their particularities lie in (i) their location in a highly functional organ that is difficult to access surgically, including for biopsy, and (ii) their rapid, anisotropic mode of extension, notably via the fiber bundles of the white matter, which further limits the possibilities of resection. The use of mathematical tools enables the development of numerical models representative of the oncotype, genotype, evolution, and therapeutic response of lesions. The significant development of digital technologies linked to high-resolution NMR exploration, coupled with the possibilities offered by AI, means that we can envisage the creation of digital twins of tumors and their host organs, thus reducing the use of physical sampling.

8.
Front Neurol ; 14: 1205256, 2023.
Article in English | MEDLINE | ID: mdl-37470004

ABSTRACT

Background: There is no consensus regarding the influence of infarct laterality in patients with acute ischemic stroke due to anterior large vessel occlusion (AIS-LVO) treated with mechanical thrombectomy (MT), particularly in low-ASPECT (0-5) patients who were excluded from the initial MT studies and that participated in dedicated randomized-controlled trials that do not consider the side of the occlusion. We aimed to evaluate the role of infarct laterality on the clinical outcome in low-ASPECT AIS patients treated with MT. Material and methods: We retrospectively analyzed our institutional stroke database in our Thrombectomy-Capable Stroke Center (TCSC), including patient characteristics, procedural variables, and outcomes, between January 2015 and January 2022. Patients with acute intracranial ICA and/or proximal MCA occlusions with ASPECT ≤ 5 either on CT or MRI were included and divided into 2 groups according to the location of ischemia. The primary endpoint was a good clinical outcome at 90 days (modified Rankin Scale (mRS) score of 0-3). Results: Between January 2015 and November 2021, 817 MT were performed, of which 82 were low-ASPECT (10.0%): 41 left-sided and 41 right-sided strokes. The rates of good clinical outcome were 30.8% (12/41) for the left-sided group and 43.6% (17/41) for the right-sided group, with a p-value of 0.349. The morality rate showed no significant difference between the two groups: 39.0% (16/41) in the right stroke group and 36.6% (15/41) in the left stroke group. Conclusion: The clinical outcome was not significantly influenced by stroke laterality. The results of this single-center retrospective study indicate either a lack of strength or equal value in performing mechanical thrombectomy regardless of stroke laterality.

10.
Radiology ; 304(1): 123-125, 2022 07.
Article in English | MEDLINE | ID: mdl-35258372

ABSTRACT

Online supplemental material is available for this article. See also the editorial by Tuite in this issue.


Subject(s)
COVID-19 , Radiology Department, Hospital , Radiology , Humans , Surveys and Questionnaires
11.
Diagn Interv Imaging ; 103(5): 266-272, 2022 May.
Article in English | MEDLINE | ID: mdl-34991994

ABSTRACT

PURPOSE: The purpose of this study was to identify attenuation threshold value on computed tomography (CT) that allowed discriminating between interstitial edematous pancreatitis (IEP) and necrotizing pancreatitis (NP) in patients with acute pancreatitis during the first week of the disease and evaluate interobserver reproducibility for the diagnosis of acute pancreatitis category. MATERIALS AND METHODS: Patients with acute pancreatitis who underwent CT examination of the abdomen between March 2015 and December 2019 were retrospectively included. Actual diagnosis of IEP or NP was based on final clinical report, follow-up evaluation, and complications. Six regions of interest were manually placed in the pancreatic gland and peripancreatic fat, and differences in CT attenuation values before contrast injection and during the portal venous phase of enhancement were computed. Performance in the diagnosis of AP category was evaluated using receiver operating characteristic analysis. Interobserver agreement was estimated by the intraclass correlation coefficient (ICC) and Bland Altman analysis was used to estimate reproducibility between pairs of observers. RESULTS: Sixty-six patients with NP (46 men, 20 women; mean age, 55 ± 17 [SD] years; age range: 20-89 years) and 70 patients with IEP (39 men, 31 women; mean age, 54 ± 18 [SD] years; age range: 21-87 years) were included. An enhancement value less than 30 Hounsfield units (HU) in the pancreatic gland during the portal phase compared to non-contrast phase, yielded 90.9% sensitivity (60/66; 95% CI: 81.3-96.6), 94.3% specificity (66/70; 95% CI: 86.0-98.4) and an area under curve of 0.958 (95% CI: 0.919-0.996) for the diagnosis of NP versus IEP. Interobserver reproducibility for pancreas enhancement was good using Bland Altman plot and ICC was excellent for pancreatic gland analysis (ICC 0.978; 95% CI: 0.961-0.988) but poor or moderate (ICC ≤0.634) regarding peripancreatic fat necrosis. CONCLUSION: By using a pancreas enhancement threshold value of 30 HU, CT is accurate and reproducible for the diagnosis of NP during the first week of the disease.


Subject(s)
Pancreatitis, Acute Necrotizing , Pancreatitis, Chronic , Acute Disease , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Necrosis , Pancreas/diagnostic imaging , Pancreatitis, Acute Necrotizing/diagnostic imaging , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed/methods , Young Adult
12.
Eur Radiol ; 31(11): 8141-8146, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33871709

ABSTRACT

OBJECTIVES: Value of chest CT was mainly studied in area of high COVID-19 incidence. The aim of this study was therefore to evaluate chest CT performances to diagnose COVID-19 pneumonia with regard to RT-PCR as reference standard in a low incidence area. METHODS: A survey was sent to radiology department in 4 hospitals in an administrative French region of weak disease prevalence (3.4%). Study design was approved by the local institutional review board and recorded on the clinicaltrial.gov website (NCT04339686). Written informed consent was waived due to retrospective anonymized data collection. Patients who underwent a RT-PCR and a chest CT scan within 48 h for COVID-19 pneumonia suspicion were consecutively included. Diagnostic accuracy including the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of chest CT regarding RT-PCR as reference standard were calculated. RESULTS: One hundred twenty-nine patients had abnormal chest CT findings compatible with a COVID-19 pneumonia (26%, 129/487). Among the 358 negative chest CT findings, 3% (10/358) were RT-PCR positive. Chest CT sensitivity, specificity, positive, and negative predictive value were respectively 87% (IC95: 85, 89; 69/79), 85% (IC95: 83, 87; 348/408), 53% (IC95: 50, 56; 69/129), and 97% (IC95: 95, 99; 348/358). CONCLUSIONS: In a low prevalence area, chest CT scan is a good diagnostic tool to rule out COVID-19 infection among symptomatic suspected patients. KEY POINTS: • In a low prevalence area (3.4% in the administrative area and 5.8% at mean in the study) chest CT sensitivity and specificity for diagnosing COVID-19 pneumonia were 87% and 85% respectively. • In patients with negative chest CT for COVID-19 pneumonia, the negative predictive value of COVID-19 infection was 97% (348/358 subjects). • Performance of CT was equivalent between the 4 centers participating to this study.


Subject(s)
COVID-19 , COVID-19 Testing , Humans , Incidence , Prevalence , Retrospective Studies , SARS-CoV-2 , Sensitivity and Specificity , Tomography, X-Ray Computed
13.
Diagn Interv Imaging ; 102(9): 525-530, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33785313

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the effectiveness and complication rate of computed tomography (CT)-guided epidural injection of steroids and local anesthetics for pain relief in patients with neuralgia due to acute or chronic herpes zoster (HZ). MATERIALS AND METHODS: A prospective study was conducted from April 2017 to February 2019 including patients with HZ neuralgia (HZN) at any stage (acute or chronic, the latter being defined as pain lasting more than 3 months and also called post herpetic neuralgia [PHN]). The sensory ganglion of the affected dermatome and/or the affected sensory nerve was targeted under CT-guidance and local injection of a mixture of two vials of methylprednisolone 40mg/mL and 2mL of Lidocaine 1% was performed. Using a visual analogue scale (VAS, 0 to 10), pain was assessed prior to the procedure, and at day 7, 1 month, 3 months and 6 months. Adverse effects were graded according to the Society of Interventional Radiology classification. RESULTS: Twenty patients were included. There were 9 men and 11 women with a mean age of 67±13.9 (SD) years (range: 27-83 years). Of these, 14 patients had acute HZN and 6 had PHN. Mean VAS at baseline was 8.1±1.2 (SD) (range: 6-10) with significant decrease (P<0.0001) at day 7 (3.4±3.2 [SD]; range: 0-10), day 30 (3.4±3.2 [SD]; range: 0-9), day 90 (2.9±3.2 [SD]; range: 0-9), and day 180 (2.5±3.1 [SD]; range: 0-9). Infiltrations were significantly more effective on acute HZN than on PHN (P<0.001) and required significantly fewer infiltrations for pain relef (P=0.002). Only one grade A adverse event was reported. CONCLUSION: Epidural injection of a mixture of steroids and local anesthetics under CT-guidance is effective on HZN with a persisting effect over 6 months.


Subject(s)
Herpes Zoster , Neuralgia, Postherpetic , Neuralgia , Adult , Aged , Aged, 80 and over , Anesthetics, Local , Female , Humans , Male , Middle Aged , Neuralgia/drug therapy , Neuralgia, Postherpetic/drug therapy , Prospective Studies , Steroids , Tomography, X-Ray Computed
14.
J Comput Assist Tomogr ; 45(2): 248-252, 2021.
Article in English | MEDLINE | ID: mdl-33512854

ABSTRACT

OBJECTIVE: To evaluate the accuracy of initial computed tomography (CT) interpretations made by radiology residents during nightshifts in the emergency department. METHODS: Preliminary CT reports performed by radiology residents during 120 consecutive nightshifts (08:30 pm to 08:30 am) were reviewed, attendings' final interpretation being the reference standard. Nightshifts were divided into four consecutive periods of 3 hours. Major misinterpretations were related to potentially life-threatening conditions if not treated immediately after CT. The rate of misinterpretations was calculated for all CT examinations, separately for nightshift's periods and for residents' training years. RESULTS: Misinterpretations were recorded in 155 (7.4%) of 2102 CT examinations, 0.6% (13/2102) were major. There were 2.2% (4/186) major misinterpretations that occurred during the last period of the nightshift versus 0.4% (9/1916) during the first periods of the night (P < 0.05). Of all misinterpretations, 8.5% (130/1526) were made by third- and fourth-year residents and 4.3% (25/576) by fifth-year residents (P < 0.005). CONCLUSIONS: Major misinterpretations occur at the end of the nightshift, which may be explained by the fatigue effect. The rate of misinterpretations is lower among fifth-year residents, which may be related to their prior experience in reading emergency cases.


Subject(s)
Emergency Service, Hospital , Radiologists , Shift Work Schedule , Tomography, X-Ray Computed , Humans , Internship and Residency , Observer Variation , Radiologists/education , Radiologists/standards , Radiologists/statistics & numerical data , Retrospective Studies , Surveys and Questionnaires , Tomography, X-Ray Computed/standards , Tomography, X-Ray Computed/statistics & numerical data
15.
Radiology ; 298(2): E81-E87, 2021 02.
Article in English | MEDLINE | ID: mdl-32870139

ABSTRACT

Background The role and performance of chest CT in the diagnosis of the coronavirus disease 2019 (COVID-19) pandemic remains under active investigation. Purpose To evaluate the French national experience using chest CT for COVID-19, results of chest CT and reverse transcription polymerase chain reaction (RT-PCR) assays were compared together and with the final discharge diagnosis used as the reference standard. Materials and Methods A structured CT scan survey (NCT04339686) was sent to 26 hospital radiology departments in France between March 2, 2020, and April 24, 2020. These dates correspond to the peak of the national COVID-19 epidemic. Radiology departments were selected to reflect the estimated geographic prevalence heterogeneities of the epidemic. All symptomatic patients suspected of having COVID-19 pneumonia who underwent both initial chest CT and at least one RT-PCR test within 48 hours were included. The final discharge diagnosis, based on multiparametric items, was recorded. Data for each center were prospectively collected and gathered each week. Test efficacy was determined by using the Mann-Whitney test, Student t test, χ2 test, and Pearson correlation coefficient. P < .05 indicated a significant difference. Results Twenty-six of 26 hospital radiology departments responded to the survey, with 7500 patients entered; 2652 did not have RT-PCR test results or had unknown or excess delay between the RT-PCR test and CT. After exclusions, 4824 patients (mean age, 64 years ± 19 [standard deviation], 2669 male) were included. With final diagnosis as the reference, 2564 of the 4824 patients had COVID-19 (53%). Sensitivity, specificity, negative predictive value, and positive predictive value of chest CT in the diagnosis of COVID-19 were 2319 of 2564 (90%; 95% CI: 89, 91), 2056 of 2260 (91%; 95% CI: 91, 92), 2056 of 2300 (89%; 95% CI: 87, 90), and 2319 of 2524 (92%; 95% CI: 91, 93), respectively. There was no significant difference for chest CT efficacy among the 26 geographically separate sites, each with varying amounts of disease prevalence. Conclusion Use of chest CT for the initial diagnosis and triage of patients suspected of having coronavirus disease 2019 was successful. © RSNA, 2021 Online supplemental material is available for this article.


Subject(s)
COVID-19/diagnostic imaging , COVID-19/epidemiology , Radiography, Thoracic/methods , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Female , France/epidemiology , Humans , Male , Middle Aged , Prospective Studies , SARS-CoV-2 , Sensitivity and Specificity , Young Adult
17.
Eur Radiol ; 30(12): 6537-6544, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32621241

ABSTRACT

PURPOSE: To determine the impact of the COVID-19 on the CT activities in French radiological centers during the epidemic peak. MATERIALS AND METHODS: A cross-sectional prospective CT scan survey was conducted between March 16 and April 12, 2020, in accordance with the local IRB. Seven hundred nine radiology centers were invited to participate in a weekly online survey. Numbers of CT examinations related to COVID-19 including at least chest (CTcovid) and whole chest CT scan activities (CTchest) were recorded each week. A sub-analysis on French departments was performed during the 4 weeks of the study. The impact of the number of RT-PCRs (reverse transcriptase polymerase chain reactions) on the CT workflow was tested using two-sample t test and Pearson's test. RESULTS: Five hundred seventy-seven structures finally registered (78%) with mean response numbers of 336 ± 18.9 (323; 351). Mean CTchest activity per radiologic structure ranged from 75.8 ± 133 (0-1444) on week 12 to 99.3 ± 138.6 (0-1147) on week 13. Mean ratio of CTcovid on CTchest varied from 0.36 to 0.59 on week 12 and week 14 respectively. There was a significant relationship between the number of RT-PCR performed and the number of CTcovid (r = 0.73, p = 3.10-16) but no link with the number of positive RT-PCR results. CONCLUSION: In case of local high density COVID-19, CT workflow is strongly modified and redirected to the management of these specific patients. KEY POINTS: • Over the 4-week survey period, 117,686 chest CT (CTtotal) were performed among the responding centers, including 61,784 (52%) CT performed for COVID-19 (CTcovid). • Across the country, the ratio CTcovid/CTtotal varied from 0.36 to 0.59 and depended significantly on the local epidemic density (p = 0.003). • In clinical practice, in a context of growing epidemic, in France, chest CT was used as a surrogate to RT-PCR for patient triage.


Subject(s)
Betacoronavirus , Coronavirus Infections/diagnosis , Pandemics , Pneumonia, Viral/diagnosis , Tomography, X-Ray Computed/methods , Triage/methods , Adult , COVID-19 , Coronavirus Infections/epidemiology , Cross-Sectional Studies , Female , France/epidemiology , Humans , Male , Middle Aged , Pneumonia, Viral/epidemiology , Prospective Studies , SARS-CoV-2 , Surveys and Questionnaires
18.
Emerg Radiol ; 27(2): 151-156, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31781984

ABSTRACT

OBJECTIVES: To evaluate radiological diagnosis concordance between a simplified and a multiphasic computed tomography (MCT) protocol for patients presenting acute non-traumatic abdominal pains (ANTAE). METHODS: During five consecutive months, all patients admitted in an emergency department for ANTAE were retrospectively included if they underwent MCT, including at least pre-contrast phase, late arterial phase (LAP), and portal venous phase (PVP). Clinical cases of suspected hemorrhagic conditions were secondarily excluded. For the study, two image sets, pre-contrast phase + LAP + PVP ± late phase called S1 and PVP alone called S2, were reviewed independently to give the most appropriate diagnosis with 5-point confidence scale. Diagnosis concordance and radiation dose were compared for each set of protocol by chi-square test. Linear mixed model was used to assess changes of diagnostic confidence and radiation dose. RESULTS: All in all, 196 patients were included. The kappa coefficient between S1 and S2 was excellent (98.5%, CI95% 95.6-99.7). Three errors due to an inappropriate protocol were observed (1.5%; CI95% = - 0.2 to 3.2%), 2 related to biliary tract obstruction causes and one due to gastric bleeding not suspected on clinical data. S2 was associated with a 61% decrease of the radiation dose (p = 0.01) with a mild decrease of the confidence scale (4.54 ± 0.05 versus 4.74 ± 0.03, p = 0.001). CONCLUSION: Using PVP-CT alone or MCT is equivalent for the diagnosis of ANTAE if suspected acute hemorrhages are excluded. A simplified CT protocol is associated with a dose decrease of 61%.


Subject(s)
Abdomen, Acute/diagnostic imaging , Emergency Service, Hospital , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Contrast Media , Female , Humans , Iopamidol/analogs & derivatives , Male , Middle Aged , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies
19.
BMJ Open ; 9(8): e026962, 2019 09 03.
Article in English | MEDLINE | ID: mdl-31481365

ABSTRACT

INTRODUCTION: Fractures of the tibial plateau are in constant progression. They affect an elderly population suffering from a number of comorbidities, but also a young population increasingly practicing high-risk sports. The conventional open surgical technique used for tibial plateau fractures has several pitfalls: bone and skin devascularisation, increased risks of infection and functional rehabilitation difficulties. Since 2011, Poitiers University Hospital is offering to its patients a new minimally invasive technique for the reduction and stabilisation of tibial plateau fractures, named 'tibial tuberoplasty'. This technique involves expansion of the tibial plateau through inflation using a kyphoplasty balloon, filling of the fracture cavity with cement and percutaneous screw fixation. We designed a study to evaluate the quality of fracture reduction offered by percutaneous tuberoplasty versus conventional open surgery for tibial plateau fracture and its impact on clinical outcome. METHODS AND ANALYSIS: This is a multicentre randomised controlled trial comparing two surgical techniques in the treatment of tibial plateau fractures. 140 patients with a Schatzker II or III tibial plateau fracture will be recruited in France. They will be randomised either in tibial tuberoplasty arm or in conventional surgery arm. The primary outcome is the postoperative radiological step-off reduction blindly measured on CT scan (within 48 hours post-op). Additional outcomes include other radiological endpoints, pain, functional abilities, quality of life assessment and health-economic endpoints. Outcomes assessment will be performed at baseline (before surgery), at day 0 (surgery), at 2, 21, 45 days, 3, 6, 12 and 24 months postsurgery. ETHICS AND DISSEMINATION: This study has been approved by the ethics committee Ile-De-France X and will be conducted in accordance with current Good Clinical Practice (GCP) guidelines, Declaration of Helsinki and standard operating procedures. The results will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. TRIAL REGISTRATION NUMBER: Clinicaltrial.gov:NCT03444779.


Subject(s)
Fracture Fixation, Internal/methods , Multicenter Studies as Topic/methods , Randomized Controlled Trials as Topic/methods , Tibial Fractures/surgery , Humans , Minimally Invasive Surgical Procedures , Prospective Studies , Single-Blind Method , Tibial Fractures/classification
20.
Ann Clin Transl Neurol ; 6(7): 1332-1337, 2019 07.
Article in English | MEDLINE | ID: mdl-31353859

ABSTRACT

Biotin is thought to improve functional impairment in progressive multiple sclerosis (MS) by upregulating bioenergetic metabolism. We enrolled 19 patients suffering from progressive MS (5 primary and 14 secondary Progressive-MS). Using cerebral multinuclear magnetic resonance spectroscopy (MMRS) and clinical evaluation before and after 6 months of biotin cure, we showed significant modifications of: PME/PDE, ATP, and lactate resonances; an improvement of EDSS Neuroscore. Our results are consistent with metabolic pathways concerned with biotin action and could suggest the usefulness of MMRS for monitoring.


Subject(s)
Biotin/metabolism , Multiple Sclerosis/diagnostic imaging , Multiple Sclerosis/metabolism , Female , Humans , Magnetic Resonance Spectroscopy , Male , Middle Aged , Multiple Sclerosis, Chronic Progressive/diagnostic imaging , Multiple Sclerosis, Chronic Progressive/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL