1.
Diagnostics (Basel) ; 14(11)2024 May 29.
Article in English | MEDLINE | ID: mdl-38893656

ABSTRACT

The clinical use of photon-counting CT (PCCT) allows for the generation of virtual non-contrast (VNC) series from contrast-enhanced images. In routine clinical practice, specific issues such as ruling out acute bleeding require non-contrast images. The aim of this study is to evaluate the use of PCCT-derived VNC reconstructions in abdominal imaging. PCCT scans of 17 patients including early arterial, portal venous and native sequences were enrolled. VNC reconstructions have been calculated. In every sequence and VNC reconstruction, 10 ROIs were measured (portal vein, descending aorta, inferior vena cava, liver parenchyma, spleen parenchyma, erector spinae muscle, subcutaneous adipose tissue, first lumbar vertebral body, air, and psoas muscle) and density values were compared. The VNC reconstructions show significant changes in density compared to the contrast-enhanced images. However, there were no significant differences present between the true non-contrast (TNC) and any VNC reconstructions in the observed organs and vessels. Significant differences (p < 0.05) between the measured mean density values in the TNC versus VNC reconstructions were found in fat and bone tissue. The PCCT-derived VNC reconstructions seemed to be comparable to the TNC images, despite some deviations shown in the adipose tissue and bone structures. However, the further benefits in terms of specific clinical issues need to be evaluated.

2.
Front Med (Lausanne) ; 11: 1407235, 2024.
Article in English | MEDLINE | ID: mdl-38903806

ABSTRACT

Purpose: This study compares phantom-based variability of extracted radiomics features from scans on a photon counting CT (PCCT) and an experimental animal PET/CT-scanner (Albira II) to investigate the potential of radiomics for translation from animal models to human scans. While oncological basic research in animal PET/CT has allowed an intrinsic comparison between PET and CT, but no 1:1 translation to a human CT scanner due to resolution and noise limitations, Radiomics as a statistical and thus scale-independent method can potentially close the critical gap. Methods: Two phantoms were scanned on a PCCT and animal PET/CT-scanner with different scan parameters and then the radiomics parameters were extracted. A Principal Component Analysis (PCA) was conducted. To overcome the limitation of a small dataset, a data augmentation technique was applied. A Ridge Classifier was trained and a Feature Importance- and Cluster analysis was performed. Results: PCA and Cluster Analysis shows a clear differentiation between phantom types while emphasizing the comparability of both scanners. The Ridge Classifier exhibited a strong training performance with 93% accuracy, but faced challenges in generalization with a test accuracy of 62%. Conclusion: These results show that radiomics has great potential as a translational tool between animal models and human routine diagnostics, especially using the novel photon counting technique. This is another crucial step towards integration of radiomics analysis into clinical practice.

3.
Diagnostics (Basel) ; 14(3)2024 Jan 27.
Article in English | MEDLINE | ID: mdl-38337793

ABSTRACT

(1) Background: Epicardial adipose tissue influences cardiac biology in physiological and pathological terms. As it is suspected to be linked to coronary artery calcification, identifying improved methods of diagnostics for these patients is important. The use of radiomics and the new Photon-Counting computed tomography (PCCT) may offer a feasible step toward improved diagnostics in these patients. (2) Methods: In this retrospective single-centre study epicardial adipose tissue was segmented manually on axial unenhanced images. Patients were divided into three groups, depending on the severity of coronary artery calcification. Features were extracted using pyradiomics. Mean and standard deviation were calculated with the Pearson correlation coefficient for feature correlation. Random Forest classification was applied for feature selection and ANOVA was performed for group comparison. (3) Results: A total of 53 patients (32 male, 21 female, mean age 57, range from 21 to 80 years) were enrolled in this study and scanned on the novel PCCT. "Original_glrlm_LongRunEmphasis", "original_glrlm_RunVariance", "original_glszm_HighGrayLevelZoneEmphasis", and "original_glszm_SizeZoneNonUniformity" were found to show significant differences between patients with coronary artery calcification (Agatston score 1-99/≥100) and those without. (4) Conclusions: Four texture features of epicardial adipose tissue are associated with coronary artery calcification and may reflect inflammatory reactions of epicardial adipose tissue, offering a potential imaging biomarker for atherosclerosis detection.

4.
Rofo ; 196(3): 262-272, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37944935

ABSTRACT

With personalized tumor therapy, understanding and addressing the heterogeneity of malignant tumors is becoming increasingly important. Heterogeneity can be found within one lesion (intralesional) and between several tumor lesions emerging from one primary tumor (interlesional). The heterogeneous tumor cells may show a different response to treatment due to their biology, which in turn influences the outcome of the affected patients and the choice of therapeutic agents. Therefore, both intra- and interlesional heterogeneity should be addressed at the diagnostic stage. While genetic and biological heterogeneity are important parameters in molecular tumor characterization and in histopathology, they are not yet addressed routinely in medical imaging. This article summarizes the recently established markers for tumor heterogeneity in imaging as well as heterogeneous/mixed response to therapy. Furthermore, a look at emerging markers is given. The ultimate goal of this overview is to provide comprehensive understanding of tumor heterogeneity and its implications for radiology and for communication with interdisciplinary teams in oncology. KEY POINTS:: · Tumor heterogeneity can be described within one lesion (intralesional) or between several lesions (interlesional).. · The heterogeneous biology of tumor cells can lead to a mixed therapeutic response and should be addressed in diagnostics and the therapeutic regime.. · Quantitative image diagnostics can be enhanced using AI, improved histopathological methods, and liquid profiling in the future..


Subject(s)
Neoplasms , Humans , Neoplasms/diagnostic imaging , Neoplasms/genetics , Neoplasms/therapy , Diagnostic Imaging , Medical Oncology , Radiography
6.
Cancer Imaging ; 23(1): 95, 2023 Oct 05.
Article in English | MEDLINE | ID: mdl-37798797

ABSTRACT

OBJECTIVES: The goal of this study is to demonstrate the performance of radiomics and CNN-based classifiers in determining the primary origin of gastrointestinal liver metastases for visually indistinguishable lesions. METHODS: In this retrospective, IRB-approved study, 31 pancreatic cancer patients with 861 lesions (median age [IQR]: 65.39 [56.87, 75.08], 48.4% male) and 47 colorectal cancer patients with 435 lesions (median age [IQR]: 65.79 [56.99, 74.62], 63.8% male) were enrolled. A pretrained nnU-Net performed automated segmentation of 1296 liver lesions. Radiomics features for each lesion were extracted using pyradiomics. The performance of several radiomics-based machine-learning classifiers was investigated for the lesions and compared to an image-based deep-learning approach using a DenseNet-121. The performance was evaluated by AUC/ROC analysis. RESULTS: The radiomics-based K-nearest neighbor classifier showed the best performance on an independent test set with AUC values of 0.87 and an accuracy of 0.67. In comparison, the image-based DenseNet-121-classifier reached an AUC of 0.80 and an accuracy of 0.83. CONCLUSIONS: CT-based radiomics and deep learning can distinguish the etiology of liver metastases from gastrointestinal primary tumors. Compared to deep learning, radiomics based models showed a varying generalizability in distinguishing liver metastases from colorectal cancer and pancreatic adenocarcinoma.


Subject(s)
Adenocarcinoma , Colorectal Neoplasms , Deep Learning , Liver Neoplasms , Pancreatic Neoplasms , Humans , Male , Female , Retrospective Studies , Pancreatic Neoplasms/diagnostic imaging , Tomography, X-Ray Computed/methods , Liver Neoplasms/diagnostic imaging , Pancreatic Neoplasms
7.
Microorganisms ; 11(7)2023 Jul 03.
Article in English | MEDLINE | ID: mdl-37512912

ABSTRACT

BACKGROUND: Severe courses and high hospitalization rates were ubiquitous during the first pandemic SARS-CoV-2 waves. Thus, we aimed to examine whether integrative diagnostics may aid in identifying vulnerable patients using crucial data and materials obtained from COVID-19 patients hospitalized between 2020 and 2021 (n = 52). Accordingly, we investigated the potential of laboratory biomarkers, specifically the dynamic cell decay marker cell-free DNA and radiomics features extracted from chest CT. METHODS: Separate forward and backward feature selection was conducted for linear regression with the Intensive-Care-Unit (ICU) period as the initial target. Three-fold cross-validation was performed, and collinear parameters were reduced. The model was adapted to a logistic regression approach and verified in a validation naïve subset to avoid overfitting. RESULTS: The adapted integrated model classifying patients into "ICU/no ICU demand" comprises six radiomics and seven laboratory biomarkers. The models' accuracy was 0.54 for radiomics, 0.47 for cfDNA, 0.74 for routine laboratory, and 0.87 for the combined model with an AUC of 0.91. CONCLUSION: The combined model performed superior to the individual models. Thus, integrating radiomics and laboratory data shows synergistic potential to aid clinic decision-making in COVID-19 patients. Under the need for evaluation in larger cohorts, including patients with other SARS-CoV-2 variants, the identified parameters might contribute to the triage of COVID-19 patients.

8.
BMC Med Imaging ; 23(1): 97, 2023 07 26.
Article in English | MEDLINE | ID: mdl-37495950

ABSTRACT

BACKGROUND: Cardiovascular diseases remain the world's primary cause of death. The identification and treatment of patients at risk of cardiovascular events thus are as important as ever. Adipose tissue is a classic risk factor for cardiovascular diseases, has been linked to systemic inflammation, and is suspected to contribute to vascular calcification. To further investigate this issue, the use of texture analysis of adipose tissue using radiomics features could prove a feasible option. METHODS: In this retrospective single-center study, 55 patients (mean age 56, 34 male, 21 female) were scanned on a first-generation photon-counting CT. On axial unenhanced images, periaortic adipose tissue surrounding the thoracic descending aorta was segmented manually. For feature extraction, patients were divided into three groups, depending on coronary artery calcification (Agatston Score 0, Agatston Score 1-99, Agatston Score ≥ 100). 106 features were extracted using pyradiomics. R statistics was used for statistical analysis, calculating mean and standard deviation with Pearson correlation coefficient for feature correlation. Random Forest classification was carried out for feature selection and Boxplots and heatmaps were used for visualization. Additionally, monovariable logistic regression predicting an Agatston Score > 0 was performed, selected features were tested for multicollinearity and a 10-fold cross-validation investigated the stability of the leading feature. RESULTS: Two higher-order radiomics features, namely "glcm_ClusterProminence" and "glcm_ClusterTendency" were found to differ between patients without coronary artery calcification and those with coronary artery calcification (Agatston Score ≥ 100) through Random Forest classification. As the leading differentiating feature "glcm_ClusterProminence" was identified. CONCLUSION: Changes in periaortic adipose tissue texture seem to correlate with coronary artery calcium score, supporting a possible influence of inflammatory or fibrotic activity in perivascular adipose tissue. Radiomics features may potentially aid as corresponding biomarkers in the future.


Subject(s)
Cardiovascular Diseases , Coronary Artery Disease , Humans , Male , Female , Calcium , Retrospective Studies , Tomography, X-Ray Computed/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging
9.
Eur Radiol ; 33(7): 4905-4914, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36809435

ABSTRACT

OBJECTIVES: Radiomics image data analysis offers promising approaches in research but has not been implemented in clinical practice yet, partly due to the instability of many parameters. The aim of this study is to evaluate the stability of radiomics analysis on phantom scans with photon-counting detector CT (PCCT). METHODS: Photon-counting CT scans of organic phantoms consisting of 4 apples, kiwis, limes, and onions each were performed at 10 mAs, 50 mAs, and 100 mAs with 120-kV tube current. The phantoms were segmented semi-automatically and original radiomics parameters were extracted. This was followed by statistical analysis including concordance correlation coefficients (CCC), intraclass correlation coefficients (ICC), as well as random forest (RF) analysis, and cluster analysis to determine the stable and important parameters. RESULTS: Seventy-three of the 104 (70%) extracted features showed excellent stability with a CCC value > 0.9 when compared in a test and retest analysis, and 68 features (65.4%) were stable compared to the original in a rescan after repositioning. Between the test scans with different mAs values, 78 (75%) features were rated with excellent stability. Eight radiomics features were identified that had an ICC value greater than 0.75 in at least 3 of 4 groups when comparing the different phantoms in a phantom group. In addition, the RF analysis identified many features that are important for distinguishing the phantom groups. CONCLUSION: Radiomics analysis using PCCT data provides high feature stability on organic phantoms, which may facilitate the implementation of radiomics analysis likewise in clinical routine. KEY POINTS: • Radiomics analysis using photon-counting computed tomography provides high feature stability. • Photon-counting computed tomography may pave the way for implementation of radiomics analysis in clinical routine.


Subject(s)
Random Forest , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Image Processing, Computer-Assisted/methods , Photons
10.
Sci Rep ; 12(1): 19594, 2022 11 15.
Article in English | MEDLINE | ID: mdl-36379992

ABSTRACT

Feature stability and standardization remain challenges that impede the clinical implementation of radiomics. This study investigates the potential of spectral reconstructions from photon-counting computed tomography (PCCT) regarding organ-specific radiomics feature stability. Abdominal portal-venous phase PCCT scans of 10 patients in virtual monoenergetic (VM) (keV 40-120 in steps of 10), polyenergetic, virtual non-contrast (VNC), and iodine maps were acquired. Two 2D and 3D segmentations measuring 1 and 2 cm in diameter of the liver, lung, spleen, psoas muscle, subcutaneous fat, and air were obtained for spectral reconstructions. Radiomics features were extracted with pyradiomics. The calculation of feature-specific intraclass correlation coefficients (ICC) was performed by comparing all segmentation approaches and organs. Feature-wise and organ-wise correlations were evaluated. Segmentation-resegmentation stability was evaluated by concordance correlation coefficient (CCC). Compared to non-VM, VM-reconstruction features tended to be more stable. For VM reconstructions, 3D 2 cm segmentation showed the highest average ICC with 0.63. Based on a criterion of ≥ 3 stable organs and an ICC of ≥ 0.75, 12-mainly non-first-order features-are shown to be stable between the VM reconstructions. In a segmentation-resegmentation analysis in 3D 2 cm, three features were identified as stable based on a CCC of > 0.6 in ≥ 3 organs in ≥ 6 VM reconstructions. Certain radiomics features vary between monoenergetic reconstructions and depend on the ROI size. Feature stability was also shown to differ between different organs. Yet, glcm_JointEntropy, gldm_GrayLevelNonUniformity, and firstorder_Entropy could be identified as features that could be interpreted as energy-independent and segmentation-resegmentation stable in this PCCT collective. PCCT may support radiomics feature standardization and comparability between sites.


Subject(s)
Iodine , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods
11.
Cancers (Basel) ; 14(14)2022 Jul 09.
Article in English | MEDLINE | ID: mdl-35884409

ABSTRACT

Similar to the transformation towards personalized oncology treatment, emerging techniques for evaluating oncologic imaging are fostering a transition from traditional response assessment towards more comprehensive cancer characterization via imaging. This development can be seen as key to the achievement of truly personalized and optimized cancer diagnosis and treatment. This review gives a methodological introduction for clinicians interested in the potential of quantitative imaging biomarkers, treating of radiomics models, texture visualization, convolutional neural networks and automated segmentation, in particular. Based on an introduction to these methods, clinical evidence for the corresponding imaging biomarkers-(i) dignity and etiology assessment; (ii) tumoral heterogeneity; (iii) aggressiveness and response; and (iv) targeting for biopsy and therapy-is summarized. Further requirements for the clinical implementation of these imaging biomarkers and the synergistic potential of personalized molecular cancer diagnostics and liquid profiling are discussed.

12.
Diagnostics (Basel) ; 12(7)2022 Jul 08.
Article in English | MEDLINE | ID: mdl-35885567

ABSTRACT

The coronary artery calcium score is an independent risk factor of the development of adverse cardiac events. The severity of coronary artery calcification may influence the myocardial texture. Due to higher spatial resolution and signal-to-noise ratio, new CT technologies such as PCCT may improve the detection of texture alterations depending on the severity of coronary artery calcification. In this retrospective, single-center, IRB-approved study, left ventricular myocardium was segmented and radiomics features were extracted using pyradiomics. The mean and standard deviation with the Pearson correlation coefficient for correlations of features were calculated and visualized as boxplots and heatmaps. Random forest feature selection was performed. Thirty patients (26.7% women, median age 58 years) were enrolled in the study. Patients were divided into two subgroups depending on the severity of coronary artery calcification (Agatston score 0 and Agatston score ≥ 100). Through random forest feature selection, a set of four higher-order features could be defined to discriminate myocardial texture between the two groups. When including the additional Agatston 1-99 groups as a validation, a severity-associated change in feature intensity was detected. A subset of radiomics features texture alterations of the left ventricular myocardium was associated with the severity of coronary artery calcification estimated by the Agatston score.

13.
Diagnostics (Basel) ; 12(5)2022 May 23.
Article in English | MEDLINE | ID: mdl-35626448

ABSTRACT

The implementation of radiomics-based, quantitative imaging parameters is hampered by a lack of stability and standardization. Photon-counting computed tomography (PCCT), compared to energy-integrating computed tomography (EICT), does rely on a novel detector technology, promising better spatial resolution and contrast-to-noise ratio. However, its effect on radiomics feature properties is unknown. This work investigates this topic in myocardial imaging. In this retrospective, single-center IRB-approved study, the left ventricular myocardium was segmented on CT, and the radiomics features were extracted using pyradiomics. To compare features between scanners, a t-test for non-paired samples and F-test was performed, with a threshold of 0.05 set as a benchmark for significance. Feature correlations were calculated by the Pearson correlation coefficient, and visualization was performed with heatmaps. A total of 50 patients (56% male, mean age 56) were enrolled in this study, with equal proportions of PCCT and EICT. First-order features were, nearly, comparable between both groups. However, higher-order features showed a partially significant difference between PCCT and EICT. While first-order radiomics features of left ventricular myocardium show comparability between PCCT and EICT, detected differences of higher-order features may indicate a possible impact of improved spatial resolution, better detection of lower-energy photons, and a better signal-to-noise ratio on texture analysis on PCCT.

14.
Cancers (Basel) ; 14(7)2022 Mar 24.
Article in English | MEDLINE | ID: mdl-35406418

ABSTRACT

(1) Background: Tumoral heterogeneity (TH) is a major challenge in the treatment of metastatic colorectal cancer (mCRC) and is associated with inferior response. Therefore, the identification of TH would be beneficial for treatment planning. TH can be assessed by identifying genetic alterations. In this work, a radiomics-based approach for assessment of TH in colorectal liver metastases (CRLM) in CT scans is demonstrated. (2) Methods: In this retrospective study, CRLM of mCRC were segmented and radiomics features extracted using pyradiomics. Unsupervised k-means clustering was applied to features and lesions. Feature redundancy was evaluated by principal component analysis and reduced by Pearson correlation coefficient cutoff. Feature selection was conducted by LASSO regression and visual analysis of the clusters by radiologists. (3) Results: A total of 47 patients' (36% female, median age 64) CTs with 261 lesions were included. Five clusters were identified, and the categories small disseminated (n = 31), heterogeneous (n = 105), homogeneous (n = 64), mixed (n = 59), and very large type (n = 2) were assigned based on visual characteristics. Further statistical analysis showed correlation (p < 0.01) of clusters with sex, primary location, T- and N-status, and mutational status. Feature reduction and selection resulted in the identification of four features as a final set for cluster definition. (4) Conclusions: Radiomics features can characterize TH in liver metastases of mCRC in CT scans, and may be suitable for a better pretherapeutic classification of liver lesion phenotypes.

15.
Eur J Radiol ; 146: 110105, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34920293

ABSTRACT

The development towards targeted treatments in oncology has been accompanied by significant improvements in molecular imaging. Yet, broad application of novel imaging techniques has partly been slowed down due to economical considerations. Building on the broad positive evidence of its diagnostic accuracy, modelling of effects on long-term costs and effectiveness may help to foster a broader application and acceptance of comprehensive molecular imaging techniques, such as PET/MRI. In this article, common economic evaluation techniques and cost-effectiveness analysis (CEA) evaluation methods will be introduced including Markov models and incremental cost-effectiveness ratios (ICER). This is complemented with a review of literature on recently published cost-effectiveness of molecular imaging. Additionally, the strategic relevance of CEAs for the molecular imaging community is discussed and combined with a global outlook.


Subject(s)
Magnetic Resonance Imaging , Positron-Emission Tomography , Cost-Benefit Analysis , Humans , Molecular Imaging , Quality-Adjusted Life Years
16.
In Vivo ; 35(2): 1177-1183, 2021.
Article in English | MEDLINE | ID: mdl-33622918

ABSTRACT

BACKGROUND: Crossed cerebellar diaschisis (CCD) is a phenomenon with depressed metabolism and hypoperfusion in the cerebellum. Using arterial spin-labelling perfusion weighted magnetic resonance imaging (ASL PWI), we investigated the frequency of CCD in patients with Alzheimer's disease (AD) and differences between patients with and without CCD. PATIENTS AND METHODS: In patients with AD who underwent a standardized magnetic resonance imaging including ASL PWI cerebral blood flow was evaluated in the cerebellum, and brain segmentation/volumetry was performed using mdbrain (mediaire GmbH, Berlin, Germany) and FSL FIRST (Functional Magnetic Resonance Imaging of the Brain Software Library). RESULTS: In total, 65 patients were included, and 22 (33.8%) patients were assessed as being CCD-positive. Patients with CCD had a significantly smaller whole brain volume (862.8±49.9 vs. 893.7±62.7 ml, p=0.049) as well as white matter volume (352.9±28.0 vs. 374.3±30.7, p=0.008) in comparison to patients without CCD. CONCLUSION: It was possible to detect CCD by ASL PWI in approximately one-third of patients with AD and was associated with smaller whole brain and white matter volume.


Subject(s)
Alzheimer Disease , Alzheimer Disease/complications , Alzheimer Disease/diagnostic imaging , Cerebellum/diagnostic imaging , Cerebrovascular Circulation , Germany , Humans , Magnetic Resonance Imaging , Perfusion , Spin Labels