Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
2.
J Mater Sci Mater Med ; 30(6): 67, 2019 Jun 04.
Article in English | MEDLINE | ID: mdl-31165278

ABSTRACT

Braiding of Nitinol micro wires is an established technology for the manufacturing of fine-meshed neurovascular implants for tortuous vessel geometries. Electropolishing of wires before the braiding process has the potential to improve the in vitro behaviour in terms of thrombogenicity and endothelial cell proliferation. In this study, we present the first in vitro investigation of braided electropolished/blue oxide Nitinol samples in a blood flow loop, showing a significantly lower activation of the coagulation pathway (represented by the TAT III marker) and a tendency towards reduced platelet adhesion. Furthermore, we applied the same surface treatment on flat disks and measured protein adhesion as well as endothelial cell proliferation. We compared our results to non-electropolished samples with a native oxide surface. While platelet deposition was reduced on electropolished/blue oxide surface, a significant increase of endothelial cell seeding was observed. Investigation of inflammatory marker expression in endothelial cells provided divergent results depending on the marker tested, demanding closer investigation. Surface analysis using Auger electron spectroscopy revealed a thin layer mainly consisting of titanium oxynitride or titanium oxide + titanium nitride as a potential cause of the improved biological performance. Translated to the clinical field of intracranial aneurysm treatment, the improved biocompatibility has the potential to increase both safety (low thrombogenicity) and effectiveness (aneurysm neck reconstruction).


Subject(s)
Alloys/chemistry , Blood Coagulation/drug effects , Blood Vessels/pathology , Coated Materials, Biocompatible/chemistry , Endothelial Cells/cytology , Platelet Adhesiveness , Prostheses and Implants , Adsorption , Aneurysm/surgery , Blood Platelets , Cell Adhesion , Cell Proliferation , Elasticity , Electrochemistry , Humans , Inflammation , Materials Testing , Nickel/chemistry , Oxides/chemistry , Patient Safety , Surface Properties , Titanium/chemistry
3.
Drug Des Devel Ther ; 11: 2753-2762, 2017.
Article in English | MEDLINE | ID: mdl-29075100

ABSTRACT

Polypropylene mesh implants are routinely used to repair abdominal wall defects or incisional hernia. However, complications associated with mesh implantation, such as mesh-related infections, can cause serious problems and may require complete surgical removal. Hence, the aim of the present study was the development of a safe and efficient coating to reduce postoperative mesh infections. Biodegradable poly(lactide-co-glycolide acid) microspheres loaded with rifampicin as an antibacterial agent were prepared through single emulsion evaporation method. The particle size distribution (67.93±3.39 µm for rifampicin-loaded microspheres and 64.43±3.61 µm for unloaded microspheres) was measured by laser diffraction. Furthermore, the encapsulation efficiency of rifampicin (61.5%±2.58%) was detected via ultraviolet-visible (UV/Vis) spectroscopy. The drug release of rifampicin-loaded microspheres was detected by UV/Vis spectroscopy over a period of 60 days. After 60 days, 92.40%±3.54% of the encapsulated rifampicin has been continuously released. The viability of BJ fibroblasts after incubation with unloaded and rifampicin-loaded microspheres was investigated using an MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay, which showed no adverse effects on the cells. Furthermore, the antibacterial impact of rifampicin-loaded microspheres and mesh implants, coated with the antibacterial microspheres, was investigated using an agar diffusion model with Staphylococcus aureus. The coated mesh implants were also tested in an in vivo mouse model of staphylococcal infection and resulted in a 100% protection against mesh implant infections or biofilm formation shown by macroscopic imaging, scanning electron microscopy, and histological examinations. This effective antibacterial mesh coating combining the benefit of a controlled drug delivery system and a potent antibacterial agent possesses the ability to significantly reduce postoperative implant infections.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Rifampin/administration & dosage , Staphylococcal Infections/prevention & control , Surgical Wound Infection/prevention & control , Animals , Anti-Bacterial Agents/pharmacology , Coated Materials, Biocompatible , Delayed-Action Preparations , Drug Liberation , Female , Lactic Acid/chemistry , Mice , Mice, Inbred C57BL , Microspheres , Particle Size , Polyglycolic Acid/chemistry , Polylactic Acid-Polyglycolic Acid Copolymer , Polypropylenes/chemistry , Rifampin/pharmacology , Staphylococcus aureus/drug effects , Surgical Mesh/microbiology , Surgical Wound Infection/microbiology , Time Factors
4.
J Biomed Mater Res A ; 105(11): 2995-3005, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28646555

ABSTRACT

Long-term performance of implanted cardiovascular grafts can be ensured if living endothelium overgrows their surface. Surface modifications to implants are therefore being sought that can encourage endothelialization while preventing thrombus formation until the natural endothelium is formed. In the present study, heparin was covalently attached to a fibrin mesh grown from a polyvinyl chloride (PVC) substrate surface by the catalytic action of surface immobilized thrombin on a fibrinogen solution. The coating prevented platelet activation, thrombin generation and clot formation, and reduced inflammatory reactions when exposed to fresh human whole blood circulating in a Chandler loop model. In addition, in vitro seeded human umbilical vein and human saphenous vein endothelial cells showed considerably enhanced attachment and proliferation on the coating. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2995-3005, 2017.


Subject(s)
Anticoagulants/chemistry , Anticoagulants/pharmacology , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Heparin/chemistry , Heparin/pharmacology , Thrombosis/prevention & control , Blood Coagulation/drug effects , Blood Vessel Prosthesis/adverse effects , Cell Adhesion/drug effects , Cells, Cultured , Endothelial Cells/cytology , Endothelial Cells/drug effects , Fibrin/chemistry , Hematocrit , Human Umbilical Vein Endothelial Cells , Humans , Platelet Activation/drug effects , Saphenous Vein/cytology , Thrombosis/blood , Thrombosis/etiology
5.
Biomed Mater Eng ; 27(4): 353-364, 2016 Sep 28.
Article in English | MEDLINE | ID: mdl-27689569

ABSTRACT

BACKGROUND: Chitosan is used in a wide field of applications and therapies and has been reported to be an effective hemostyptic. The objective of this study was to provide further information about the use of chitosan as a hemostyptic agent also taking into focus its hemocompatible effects. METHODS: Human whole blood (n=5) was anticoagulated with heparin, treated with different chitosan concentrations (0, 2.5, 5, 7.5, 10, 12.5, 25 mg/mL) and incubated at 37°C for 30 minutes. Before and after incubation different parameters for coagulation and hemocompatibility were evaluated. RESULTS: Blood treated with high chitosan concentrations showed enhanced coagulation, which we evaluated with activated clotting time, activated partial thromboplastin time and concentration of thrombin-antithrombin complexes. Furthermore, we observed an activation of blood platelets, complement cascade and granulocytes in the groups treated with chitosan. CONCLUSION: Our data indicate that chitosan activates human blood coagulation and hence has good properties as a hemostyptic agent. However, inflammatory parameters were upregulated after direct contact with human blood indicating that systemic administration of chitosans should not be performed whereas the topical use of chitosan as a hemostypticum should not present any hazard with regard to adverse inflammatory reactions at the site of application.

6.
Drug Des Devel Ther ; 10: 2823-2832, 2016.
Article in English | MEDLINE | ID: mdl-27660414

ABSTRACT

Biodegradable polymers, especially poly(lactide-co-glycolide) (PLGA), have good biocompatibility and toxicological properties. In combination with active ingredients, a specialized drug delivery system can be generated. The aim of the present study was to develop a drug delivery system consisting of PLGA microspheres loaded with the natural active ingredient totarol, which has several antimicrobial mechanisms. Totarol, isolated from the Podocarpus totara tree, was purified using column chromatography, and the eluate was checked for purity using thin layer chromatography. The spherically shaped microspheres with mean diameters of 147.21±3.45 µm and 131.14±3.69 µm (totarol-loaded and -unloaded microspheres, respectively) were created using the single emulsion evaporation method. Furthermore, the encapsulation efficiency, in a range of 84.72%±6.68% to 92.36%±0.99%, was measured via UV/vis spectroscopy. In a 90-day in vitro drug release study, the release of totarol was investigated by UV/vis spectroscopy as well, showing a release of 53.76%. The toxicity on cells was determined using BJ fibroblasts or Human Embryonic Kidney cells and an 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay, which showed no influence on the cell growth. The minimal inhibitory concentration was ascertained. A totarol concentration between 64 µg/mL and 128 µg/mL was necessary to inhibit the bacterial growth over a period of 24 hours. Biofilm formation on the surface of totarol-loaded microspheres was determined using transmission electron microscopy. No biofilm formation could be detected, even if the totarol concentration was below the minimal inhibitory concentration. The hemocompatibility investigations on various markers with fresh heparinized blood (1.5 IU/mL) showed that totarol and totarol-loaded microspheres have no influence on different blood parameters. The PLGA microspheres characterized by slow release of totarol and great entrapment efficiency represent a novel drug delivery system, which may be highly beneficial for the long-term therapy of bacterial infections.

7.
Thorac Cardiovasc Surg ; 64(7): 589-595, 2016 Oct.
Article in English | MEDLINE | ID: mdl-26765244

ABSTRACT

Background During cardiac surgery with heart-lung-machine support, abdominal swabs are routinely used to adsorb blood from the operation field. In part, abdominal swabs exhibit procoagulant activity, which is usually considered harmless. However, coagulation induction and abnormal clot formation on the surface of abdominal swabs in the operation field may, if the blood is retransfused into the extracorporeal circuit, lead to severe thromboembolic complications. The aim of the present study was to elucidate the origin of the unexpected blood clotting upon contact with hypercoagulant swabs. Methods The coagulant properties of three abdominal swabs were characterized using a simple clotting test and human whole blood, which was anticoagulated with different heparin concentrations. Eluates prepared from the abdominal swabs and the color stabilizer polydiallyamine (PDAA) were incubated with blood and blood clotting was investigated. Furthermore, the effects of the abdominal swabs on blood clotting time and on heparin were investigated. Results Our data show that the three abdominal swabs as well as the respective eluates exhibit distinctive coagulant properties. The abdominal swab with the highest hypercoagulant effect significantly reduced blood clotting time and also led to a reduction in free heparin. PDAA does not induce activation of the coagulation system. Conclusion The data indicate that the hypercoagulant swab reduces the clotting time and the concentration of free heparin. Abdominal swabs used during complex cardiac surgery with heart-lung-machine support should definitely be tested for their coagulant properties using appropriate tests before clinical applications, as it cannot be specified what leads to their hypercoagulant property.


Subject(s)
Blood Coagulation/drug effects , Blood Loss, Surgical/prevention & control , Cardiac Surgical Procedures/instrumentation , Coagulants/administration & dosage , Surgical Sponges , Anticoagulants/pharmacology , Blood Coagulation Tests , Cardiac Surgical Procedures/adverse effects , Coagulants/adverse effects , Heart-Lung Machine , Heparin/pharmacology , Humans , Materials Testing , Predictive Value of Tests , Reproducibility of Results , Surgical Sponges/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...