Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
2.
Biomed Phys Eng Express ; 10(3)2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38599190

ABSTRACT

Background. Thoracoabdominal MRI is limited by respiratory motion, especially in populations who cannot perform breath-holds. One approach for reducing motion blurring in radially-acquired MRI is respiratory gating. Straightforward 'hard-gating' uses only data from a specified respiratory window and suffers from reduced SNR. Proposed 'soft-gating' reconstructions may improve scan efficiency but reduce motion correction by incorporating data with nonzero weight acquired outside the specified window. However, previous studies report conflicting benefits, and importantly the choice of soft-gated weighting algorithm and effect on image quality has not previously been explored. The purpose of this study is to map how variable soft-gated weighting functions and parameters affect signal and motion blurring in respiratory-gated reconstructions of radial lung MRI, using neonates as a model population.Methods. Ten neonatal inpatients with respiratory abnormalities were imaged using a 1.5 T neonatal-sized scanner and 3D radial ultrashort echo-time (UTE) sequence. Images were reconstructed using ungated, hard-gated, and several soft-gating weighting algorithms (exponential, sigmoid, inverse, and linear weighting decay outside the period of interest), with %Nprojrepresenting the relative amount of data included. The apparent SNR (aSNR) and motion blurring (measured by the maximum derivative of image intensity at the diaphragm, MDD) were compared between reconstructions.Results. Soft-gating functions produced higher aSNR and lower MDD than hard-gated images using equivalent %Nproj, as expected. aSNR was not identical between different gating schemes for given %Nproj. While aSNR was approximately linear with %Nprojfor each algorithm, MDD performance diverged between functions as %Nprojdecreased. Algorithm performance was relatively consistent between subjects, except in images with high noise.Conclusion. The algorithm selection for soft-gating has a notable effect on image quality of respiratory-gated MRI; the timing of included data across the respiratory phase, and not simply the amount of data, plays an important role in aSNR. The specific soft-gating function and parameters should be considered for a given imaging application's requirements of signal and sharpness.


Subject(s)
Imaging, Three-Dimensional , Lung , Infant, Newborn , Humans , Imaging, Three-Dimensional/methods , Respiration , Magnetic Resonance Imaging/methods , Algorithms
3.
Article in English | MEDLINE | ID: mdl-38568735

ABSTRACT

RATIONALE: A hemodynamically significant patent ductus arteriosus (hsPDA) in premature infants has been associated with bronchopulmonary dysplasia (BPD) and pulmonary hypertension (PH). However, these associations remain incompletely understood. OBJECTIVES: The aim was to assess the association between hsPDA duration with clinical outcomes, PH, and phenotypic differences on lung MRI. METHODS: This retrospective cohort study identified all infants with BPD <32 weeks gestation who also underwent a research lung MRI <48 weeks postmenstrual age (PMA) from 2014-2022. Clinical echocardiograms were reviewed for hsPDA, and categorized into no hsPDA, hsPDA 1-60 days, and hsPDA >60 days. Outcome variables included BPD severity, PH at 36 weeks PMA, PH after 36 weeks PMA in the absence of shunt (PH-PVD), tracheostomy or death, and lung phenotype by MRI via modified Ochiai score, indexed total lung volume (TLVI), and whole lung hyperdensity (WLH). Logistic regression and ANOVA analysis were used. MEASUREMENTS AND MAIN RESULTS: In total, 133 infants born at 26.2 ± 1.9 weeks and 776 ± 276g were reviewed (47 no hsPDA, 44 hsPDA 1-60 days, 42 hsPDA >60 days). hsPDA duration >60 days was associated with BPD severity (p<0.01), PH at 36 weeks PMA (aOR 9.7 [95% CI: 3.3-28.4]), PH-PVD (aOR 6.5 [95% CI: 2.3-18.3]), and tracheostomy or death (aOR 3.0 [95% CI: 1.0-8.8]). Duration of hsPDA > 60 days was associated with higher Ochiai score (p=0.03) and TLVI (p=0.01), but not WLH (p=0.91). CONCLUSIONS: In infants with moderate or severe BPD, prolonged exposure to hsPDA is associated with BPD severity, PH-PVD, and increased parenchymal lung disease by MRI.

4.
J Aerosol Med Pulm Drug Deliv ; 37(1): 19-29, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38064481

ABSTRACT

Rationale: Neonates with respiratory issues are frequently treated with aerosolized medications to manage lung disease or facilitate airway clearance. Dynamic tracheal collapse (tracheomalacia [TM]) is a common comorbidity in these patients, but it is unknown whether the presence of TM alters the delivery of aerosolized drugs. Objectives: To quantify the effect of neonatal TM on the delivery of aerosolized drugs. Methods: Fourteen infant subjects with respiratory abnormalities were recruited; seven with TM and seven without TM. Respiratory-gated 3D ultrashort echo time magnetic resonance imaging (MRI) was acquired covering the central airway and lungs. For each subject, a computational fluid dynamics simulation modeled the airflow and particle transport in the central airway based on patient-specific airway anatomy, motion, and airflow rates derived from MRI. Results: Less aerosolized drug reached the distal airways in subjects with TM than in subjects without TM: of the total drug delivered, less particle mass passed through the main bronchi in subjects with TM compared with subjects without TM (33% vs. 47%, p = 0.013). In subjects with TM, more inhaled particles were deposited on the surface of the airway (48% vs. 25%, p = 0.003). This effect becomes greater with larger particle sizes and is significant for particles with a diameter >2 µm (2-5 µm, p ≤ 0.025 and 5-15 µm, p = 0.004). Conclusions: Neonatal patients with TM receive less aerosolized drug delivered to the lungs than subjects without TM. Currently, infants with lung disease and TM may not be receiving adequate and/or expected medication. Particles >2 µm in diameter are likely to deposit on the surface of the airway due to anatomical constrictions such as reduced tracheal and glottal cross-sectional area in neonates with TM. This problem could be alleviated by delivering smaller aerosolized particles.


Subject(s)
Lung Diseases , Tracheomalacia , Infant, Newborn , Infant , Humans , Administration, Inhalation , Lung , Trachea , Particle Size , Respiratory Aerosols and Droplets
5.
Pediatr Pulmonol ; 59(1): 55-62, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37787390

ABSTRACT

RATIONALE: Bronchopulmonary dysplasia (BPD) is the most common long term pulmonary morbidity in premature infants and is characterized by impaired lung growth and development. We hypothesized that lung mass growth is a critical factor in determining outcomes in infants with BPD. OBJECTIVES: To measure regional lung density and mass in infants with BPD and compare to clinical variables. METHODS: We conducted a retrospective cohort study of neonates (n = 5 controls, n = 46 with BPD). Lung mass and lung density were calculated using ultrashort echo time (UTE) magnetic resonance imaging (MRI). MEASUREMENTS AND MAIN RESULTS: Lung mass increased with increasing corrected gestational age at the time of MRI in all patients. Total, right, and left lung mass in infants with BPD trended higher than control infants (65.7 vs. 49.9 g, 36.2 vs. 26.8 g, 29.5 vs. 23.1 g, respectively). Babies with BPD who survived to discharge had higher relative lung mass than control infants and infants with BPD that did not survive to discharge (21.6 vs. 15.7 g/kg, p = .01). There was a significant association between the rate of lung mass growth and linear growth at the time of MRI (p = .034). CONCLUSIONS: Infants with BPD are capable of building lung mass over time. While this lung mass growth in infants with BPD may not represent fully functional lung tissue, higher lung mass growth is associated with increased linear growth.


Subject(s)
Bronchopulmonary Dysplasia , Infant, Newborn , Infant , Humans , Bronchopulmonary Dysplasia/complications , Retrospective Studies , Lung , Infant, Premature , Magnetic Resonance Imaging/methods , Gestational Age
6.
Magn Reson Med ; 90(6): 2420-2431, 2023 12.
Article in English | MEDLINE | ID: mdl-37526031

ABSTRACT

PURPOSE: The underlying functional and microstructural lung disease in neonates who are born preterm (bronchopulmonary dysplasia, BPD) remains poorly characterized. Moreover, there is a lack of suitable techniques to reliably assess lung function in this population. Here, we report our preliminary experience with hyperpolarized 129 Xe MRI in neonates with BPD. METHODS: Neonatal intensive care patients with established BPD were recruited (N = 9) and imaged at a corrected gestational age of median:40.7 (range:37.1, 44.4) wk using a 1.5T neonatal scanner. 2D 129 Xe ventilation and diffusion-weighted images and dissolved phase spectroscopy were acquired, alongside 1 H 3D radial UTE. 129 Xe images were acquired during a series of short apneic breath-holds (˜3 s). 1 H UTE images were acquired during tidal breathing. Ventilation defects were manually identified and qualitatively compared to lung structures on UTE. ADCs were calculated on a voxel-wise basis. The signal ratio of the 129 Xe red blood cell (RBC) and tissue membrane (M) resonances from spectroscopy was determined. RESULTS: Spiral-based 129 Xe ventilation imaging showed good image quality and sufficient sensitivity to detect mild ventilation abnormalities in patients with BPD. 129 Xe ADC values were elevated above that expected given healthy data in older children and adults (median:0.046 [range:0.041, 0.064] cm2 s-1 ); the highest value obtained from an extremely pre-term patient. 129 Xe spectroscopy revealed a low RBC/M ratio (0.14 [0.06, 0.21]). CONCLUSION: We have demonstrated initial feasibility of 129 Xe lung MRI in neonates. With further data, the technique may help guide management of infant lung diseases in the neonatal period and beyond.


Subject(s)
Bronchopulmonary Dysplasia , Adult , Infant, Newborn , Child , Humans , Bronchopulmonary Dysplasia/diagnostic imaging , Feasibility Studies , Xenon Isotopes , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods
7.
Neonatology ; 120(2): 185-195, 2023.
Article in English | MEDLINE | ID: mdl-36812903

ABSTRACT

INTRODUCTION: There is currently no validated diagnostic modality to characterize the anatomy and predict outcomes of tracheal esophageal defects, such as esophageal atresia (EA) and tracheal esophageal fistulas (TEFs). We hypothesized that ultra-short echo-time MRI would provide enhanced anatomic information allowing for evaluation of specific EA/TEF anatomy and identification of risk factors that predict outcome in infants with EA/TEF. METHODS: In this observational study, 11 infants had pre-repair ultra-short echo-time MRI of the chest completed. Esophageal size was measured at the widest point distal to the epiglottis and proximal to the carina. Angle of tracheal deviation was measured by identifying the initial point of deviation and the farthest lateral point proximal to the carina. RESULTS: Infants without a proximal TEF had a larger proximal esophageal diameter (13.5 ± 5.1 mm vs. 6.8 ± 2.1 mm, p = 0.07) when compared to infants with a proximal TEF. The angle of tracheal deviation in infants without a proximal TEF was larger than infants with a proximal TEF (16.1 ± 6.1° vs. 8.2 ± 5.4°, p = 0.09) and controls (16.1 ± 6.1° vs. 8.0 ± 3.1°, p = 0.005). An increase in the angle of tracheal deviation was positively correlated with duration of post-operative mechanical ventilation (Pearson r = 0.83, p < 0.002) and total duration of post-operative respiratory support (Pearson r = 0.80, p = 0.004). DISCUSSION: These results demonstrate that infants without a proximal TEF have a larger proximal esophagus and a greater angle of tracheal deviation which is directly correlated with the need for longer post-operative respiratory support. Additionally, these results demonstrate that MRI is a useful tool to assess the anatomy of EA/TEF.


Subject(s)
Esophageal Atresia , Tracheoesophageal Fistula , Humans , Infant , Esophageal Atresia/diagnostic imaging , Esophageal Atresia/pathology , Esophageal Atresia/surgery , Tracheoesophageal Fistula/diagnostic imaging , Tracheoesophageal Fistula/pathology , Tracheoesophageal Fistula/surgery , Postoperative Complications/pathology , Postoperative Complications/surgery , Trachea/diagnostic imaging , Prognosis
8.
J Appl Physiol (1985) ; 133(4): 893-901, 2022 10 01.
Article in English | MEDLINE | ID: mdl-36049059

ABSTRACT

Tracheomalacia is an airway condition in which the trachea excessively collapses during breathing. Neonates diagnosed with tracheomalacia require more energy to breathe, and the effect of tracheomalacia can be quantified by assessing flow-resistive work of breathing (WOB) in the trachea using computational fluid dynamics (CFD) modeling of the airway. However, CFD simulations are computationally expensive; the ability to instead predict WOB based on more straightforward measures would provide a clinically useful estimate of tracheal disease severity. The objective of this study is to quantify the WOB in the trachea using CFD and identify simple airway and/or clinical parameters that directly relate to WOB. This study included 30 neonatal intensive care unit subjects (15 with tracheomalacia and 15 without tracheomalacia). All subjects were imaged using ultrashort echo time (UTE) MRI. CFD simulations were performed using patient-specific data obtained from MRI (airway anatomy, dynamic motion, and airflow rates) to calculate the WOB in the trachea. Several airway and clinical measurements were obtained and compared with the tracheal resistive WOB. The maximum percent change in the tracheal cross-sectional area (ρ = 0.560, P = 0.001), average glottis cross-sectional area (ρ = -0.488, P = 0.006), minute ventilation (ρ = 0.613, P < 0.001), and lung tidal volume (ρ = 0.599, P < 0.001) had significant correlations with WOB. A multivariable regression model with three independent variables (minute ventilation, average glottis cross-sectional area, and minimum of the eccentricity index of the trachea) can be used to estimate WOB more accurately (R2 = 0.726). This statistical model may allow clinicians to estimate tracheal resistive WOB based on airway images and clinical data.NEW & NOTEWORTHY The work of breathing due to resistance in the trachea is an important metric for quantifying the effect of tracheal abnormalities such as tracheomalacia, but currently requires complex dynamic imaging and computational fluid dynamics simulation to calculate it. This study produces a method to predict the tracheal work of breathing based on readily available imaging and clinical metrics.


Subject(s)
Tracheomalacia , Work of Breathing , Humans , Infant, Newborn , Lung/diagnostic imaging , Tidal Volume , Trachea/diagnostic imaging , Tracheomalacia/diagnostic imaging
11.
Phys Med Biol ; 67(14)2022 07 04.
Article in English | MEDLINE | ID: mdl-35714617

ABSTRACT

Objective. We introduce an unsupervised motion-compensated reconstruction scheme for high-resolution free-breathing pulmonary magnetic resonance imaging.Approach. We model the image frames in the time series as the deformed version of the 3D template image volume. We assume the deformation maps to be points on a smooth manifold in high-dimensional space. Specifically, we model the deformation map at each time instant as the output of a CNN-based generator that has the same weight for all time-frames, driven by a low-dimensional latent vector. The time series of latent vectors account for the dynamics in the dataset, including respiratory motion and bulk motion. The template image volume, the parameters of the generator, and the latent vectors are learned directly from the k-t space data in an unsupervised fashion.Main results. Our experimental results show improved reconstructions compared to state-of-the-art methods, especially in the context of bulk motion during the scans.Significance. The proposed unsupervised motion-compensated scheme jointly estimates the latent vectors that capture the motion dynamics, the corresponding deformation maps, and the reconstructed motion-compensated images from the raw k-t space data of each subject. Unlike current motion-resolved strategies, the proposed scheme is more robust to bulk motion events during the scan.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Motion , Respiration
12.
Pediatr Radiol ; 52(12): 2306-2318, 2022 11.
Article in English | MEDLINE | ID: mdl-35556152

ABSTRACT

BACKGROUND: Pulmonary arterial hypertension, impaired cardiac function and lung hypoplasia are common in infants with congenital diaphragmatic hernia (CDH) and are associated with increased morbidity and mortality. Robust noninvasive methods to quantify these abnormalities in early infancy are lacking. OBJECTIVE: To determine the feasibility of MRI to quantify cardiopulmonary hemodynamics and function in infants with CDH and to investigate left-right blood flow and lung volume discrepancies. MATERIALS AND METHODS: We conducted a prospective MRI study of 23 neonates (isolated left CDH: 4 pre-repair, 7 post-repair, 3 pre- and post-repair; and 9 controls) performed on a small-footprint 1.5-tesla (T) scanner. We calculated MRI-based pulmonary arterial blood flow, left ventricular eccentricity index, cardiac function and lung volume. Using the Wilcoxon rank sum test for continuous data and Fisher exact test for categorical data, we made pairwise group comparisons. RESULTS: The right-to-left ratios for pulmonary artery blood flow and lung volume were elevated in pre-repair and post-repair CDH versus controls (flow: P<0.005; volume: P<0.05 pre-/post-repair). Eccentricity index at end-systole significantly differed between pre-repair and post-repair CDH (P<0.01) and between pre-repair CDH and controls (P<0.001). CONCLUSION: Cardiopulmonary MRI is a viable method to serially evaluate cardiopulmonary hemodynamics and function in critically ill infants and is useful for capturing left-right asymmetries in pulmonary blood flow and lung volume.


Subject(s)
Hernias, Diaphragmatic, Congenital , Infant, Newborn , Infant , Humans , Hernias, Diaphragmatic, Congenital/diagnostic imaging , Hernias, Diaphragmatic, Congenital/complications , Prospective Studies , Lung/abnormalities , Lung Volume Measurements , Magnetic Resonance Imaging/methods
13.
Pediatr Radiol ; 52(4): 643-660, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35122130

ABSTRACT

Bronchopulmonary dysplasia (BPD) is a common long-term complication of preterm birth. The chest radiograph appearance and survivability have evolved since the first description of BPD in 1967 because of improved ventilation and clinical strategies and the introduction of surfactant in the early 1990s. Contemporary imaging care is evolving with the recognition that comorbidities of tracheobronchomalacia and pulmonary hypertension have a great influence on outcomes and can be noninvasively evaluated with CT and MRI techniques, which provide a detailed evaluation of the lungs, trachea and to a lesser degree the heart. However, echocardiography remains the primary modality to evaluate and screen for pulmonary hypertension. This review is intended to highlight the important findings that chest radiograph, CT and MRI can contribute to precision diagnosis, phenotyping and prognosis resulting in optimal management and therapeutics.


Subject(s)
Bronchopulmonary Dysplasia , Hypertension, Pulmonary , Premature Birth , Bronchopulmonary Dysplasia/diagnostic imaging , Female , Humans , Infant, Newborn , Magnetic Resonance Imaging/adverse effects , Pregnancy , Tomography, X-Ray Computed/adverse effects
14.
Pediatr Pulmonol ; 57(4): 1042-1050, 2022 04.
Article in English | MEDLINE | ID: mdl-35029053

ABSTRACT

RATIONALE: Clinical management of neonatal bronchopulmonary dysplasia (BPD) is often imprecise and can vary widely between different institutions and providers, due to limited objective measurements of disease pathology severity. There is critical need to improve guidance on the application and timing of interventional treatments, such as tracheostomy. OBJECTIVES: To generate an imaging-based clinical tool for early identification of those patients with BPD who are likely to require later tracheostomy and long-term mechanical ventilation. METHODS: We conducted a prospective cohort study of n = 61 infants (55 BPD, 6 preterm non-BPD). Magnetic resonance imaging (MRI) scores of lung parenchymal disease were used to create a binomial logistic regression model for predicting tracheostomy requirement. This model was further investigated using clinical variables and MRI-quantified tracheomalacia (TM). MEASUREMENTS AND MAIN RESULTS: A model for predicting tracheostomy requirement was created using MRI parenchymal score. This model had 89% accuracy, 100% positive predictive value (PPV), and 85% negative predictive value (NPV), compared with 84%, 60%, and 83%, respectively, when using only relevant clinical variables. In a subset of patients with airway MRI (n = 36), a model including lung and TM measurements had 83% accuracy, 92% PPV, and 78% NPV. CONCLUSIONS: MRI-based measurements of parenchymal disease and TM can be used to predict need for tracheostomy in infants with BPD, more accurately than clinical factors alone. This prediction model has strong potential as a clinical tool for physicians and families for early determination of tracheostomy requirement.


Subject(s)
Bronchopulmonary Dysplasia , Tracheomalacia , Bronchopulmonary Dysplasia/diagnostic imaging , Bronchopulmonary Dysplasia/therapy , Humans , Infant , Infant, Newborn , Infant, Premature , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods , Prospective Studies , Tracheostomy
15.
J Perinatol ; 42(7): 866-872, 2022 07.
Article in English | MEDLINE | ID: mdl-34686834

ABSTRACT

OBJECTIVE: To demonstrate sensitivity of diffusion-weighted MRI (DW-MRI) to pulmonary cellular-space changes during normal in utero development using fetal rhesus macaques, compared to histological biomarkers. STUDY DESIGN: In vivo/ex vivo DW-MRI was acquired in 26 fetal rhesus lungs (early-canalicular through saccular stages). Apparent diffusion coefficients (ADC) from MRI and tissue area density (H&E), alveolar type-II cells (ABCA3), and epithelial cells (TTF1) from histology were compared between gestational stages. RESULTS: In vivo/ex vivo ADC correlated with each other (Spearman ρ = 0.47, P = 0.038; Bland-Altman bias = 0.0835) and with area-density (in vivo ρ = -0.56, P = 0.011; ex vivo ρ = -0.83, P < 0.0001). In vivo/ex vivo ADC increased exponentially toward saturation with gestational stage (R2 = 0.49/0.49), while area-density decreased exponentially (R2 = 0.53). ABCA3 and TTF1 stains demonstrated expected fetal cellular development. CONCLUSIONS: Fetal DW-MRI provides a non-invasive biomarker for pulmonary structural maturation, with a strong correlation to histological markers during tissue development in rhesus macaques. This method has strong potential for assessing human fetal development, particularly in patients with pulmonary hypoplasia.


Subject(s)
Diffusion Magnetic Resonance Imaging , Fetal Development , Animals , Biomarkers , Diffusion Magnetic Resonance Imaging/methods , Humans , Lung/diagnostic imaging , Macaca mulatta
16.
Front Pediatr ; 9: 707822, 2021.
Article in English | MEDLINE | ID: mdl-34307264

ABSTRACT

In this case report, we describe the clinical course of a neonate who presented initially with respiratory distress and later with choking during feeding. He was subsequently found to have an esophageal bronchus to the right upper lung lobe, a rare communicating bronchopulmonary foregut malformation. Histological and molecular analysis of the fistula and distal tissues revealed that the proximal epithelium from the esophageal bronchus has characteristics of both esophageal and respiratory epithelia. Using whole exome sequencing of the patient's and parent's DNA, we identified gene variants that are predicted to impact protein function and thus could potentially contribute to the phenotype. These will be the subject of future functional analysis.

17.
Chest ; 160(6): 2168-2177, 2021 12.
Article in English | MEDLINE | ID: mdl-34157310

ABSTRACT

BACKGROUND: In pediatrics, tracheomalacia is an airway condition that causes tracheal lumen collapse during breathing and may lead to the patient requiring respiratory support. Adult patients can narrow their glottis to self-generate positive end-expiratory pressure (PEEP) to raise the pressure in the trachea and prevent collapse. However, auto-PEEP has not been studied in newborns with tracheomalacia. The objective of this study was to measure the glottis cross-sectional area throughout the breathing cycle and to quantify total pressure difference through the glottis in patients with and without tracheomalacia. RESEARCH QUESTION: Do neonates with tracheomalacia narrow their glottises? How does the glottis narrowing affect the total pressure along the airway? STUDY DESIGN AND METHODS: Ultrashort echo time MRI was performed in 21 neonatal ICU patients (11 with tracheomalacia, 10 without tracheomalacia). MRI scans were reconstructed at four different phases of breathing. All patients were breathing room air or using noninvasive respiratory support at the time of MRI. Computational fluid dynamics simulations were performed on patient-specific virtual airway models with airway anatomic features and motion derived via MRI to quantify the total pressure difference through the glottis and trachea. RESULTS: The mean glottis cross-sectional area at peak expiration in the patients with tracheomalacia was less than half that in patients without tracheomalacia (4.0 ± 1.1 mm2 vs 10.3 ± 4.4 mm2; P = .002). The mean total pressure difference through the glottis at peak expiration was more than 10 times higher in patients with tracheomalacia compared with patients without tracheomalacia (2.88 ± 2.29 cm H2O vs 0.26 ± 0.16 cm H2O; P = .005). INTERPRETATION: Neonates with tracheomalacia narrow their glottises, which raises pressure in the trachea during expiration, thereby acting as auto-PEEP.


Subject(s)
Glottis/physiopathology , Positive-Pressure Respiration , Tracheomalacia/physiopathology , Female , Glottis/diagnostic imaging , Humans , Infant, Newborn , Magnetic Resonance Imaging , Male , Tracheomalacia/congenital , Tracheomalacia/diagnostic imaging
18.
J Perinatol ; 41(4): 707-717, 2021 04.
Article in English | MEDLINE | ID: mdl-33547408

ABSTRACT

Bronchopulmonary dysplasia (BPD) is a complex and serious cardiopulmonary morbidity in infants who are born preterm. Despite advances in clinical care, BPD remains a significant source of morbidity and mortality, due in large part to the increased survival of extremely preterm infants. There are few strong early prognostic indicators of BPD or its later outcomes, and evidence for the usage and timing of various interventions is minimal. As a result, clinical management is often imprecise. In this review, we highlight cutting-edge methods and findings from recent pulmonary imaging research that have high translational value. Further, we discuss the potential role that various radiological modalities may play in early risk stratification for development of BPD and in guiding treatment strategies of BPD when employed in varying severities and time-points throughout the neonatal disease course.


Subject(s)
Bronchopulmonary Dysplasia , Infant, Newborn, Diseases , Bronchopulmonary Dysplasia/diagnostic imaging , Humans , Infant , Infant, Extremely Premature , Infant, Newborn , Lung/diagnostic imaging , Morbidity
19.
Laryngoscope ; 131(6): E1971-E1979, 2021 06.
Article in English | MEDLINE | ID: mdl-33399240

ABSTRACT

OBJECTIVE/HYPOTHESIS: To assess the ability of ultra-short echo time (UTE)-MRI to detect subglottic stenosis (SGS) and evaluate response to balloon dilation. To correlate measurements from UTE-MRI with endotracheal-tube (ETT)-sizing and to investigate whether SGS causes change in airway dynamics. STUDY DESIGN: Animal research study. METHODS: Eight adult New-Zealand white rabbits were used as they approximate neonatal airway-size. The airways were measured using ETT-sizing and 3D UTE-MRI at baseline, 2 weeks post-cauterization induced SGS injury, and post-balloon dilation treatment. UTE-MR images were acquired to determine airway anatomy and motion. Airways were segmented from MR images. Cross-sectional area (CSA), major and minor diameters (Dmajor and Dminor ), and eccentricity were measured. RESULTS: Post-injury CSA at SGS was significantly reduced (mean 38%) compared to baseline (P = .003) using UTE-MRI. ETT-sizing correlated significantly with MRI-measured CSA at the SGS location (r = 0.6; P < .01), particularly at the post-injury timepoint (r = 0.93; P < .01). Outer diameter from ETT-sizing (OD) correlated significantly with Dmajor (r = 0.63; P < .01) from UTE-MRI at the SGS location, especially for the post-injury timepoint (r = 0.91; P < .01). Mean CSA of upper trachea did not change significantly between end-expiration and end-inspiration at any timepoint (all P > .05). Eccentricity of the upper trachea increased significantly post-balloon dilation (P < .05). CONCLUSIONS: UTE-MRI successfully detected SGS and treatment response in the rabbit model, with good correlation to ETT-sizing. Balloon dilation increased CSA at SGS, but not to baseline values. SGS did not alter dynamic motion for the trachea in this rabbit model; however, tracheas were significantly eccentric post-balloon dilation. UTE-MRI can detect SGS without sedation or ionizing radiation and may be a non-invasive alternative to ETT-sizing. LEVEL OF EVIDENCE: NA Laryngoscope, 131:E1971-E1979, 2021.


Subject(s)
Laryngostenosis/diagnostic imaging , Magnetic Resonance Imaging/methods , Animals , Disease Models, Animal , Female , Imaging, Three-Dimensional , Intubation, Intratracheal , Laryngoscopy , Rabbits
20.
Laryngoscope ; 131(4): E1220-E1226, 2021 04.
Article in English | MEDLINE | ID: mdl-33280109

ABSTRACT

OBJECTIVES: Subglottic stenosis (SGS) is the most common type of laryngeal stenosis in neonates. SGS severity is currently graded based on percent area of obstruction (%AO) via the Myer-Cotton grading scale. However, patients with similar %AO can have widely different clinical courses. Computational fluid dynamics (CFD) based on patient-specific imaging can quantify the relationship between airway geometry and flow dynamics. We investigated the effect of %AO and axial position of SGS on work of breathing (WOB) in neonates using magnetic resonance imaging. METHODS: High-resolution ultrashort echo-time MRI of the chest and airway was obtained in three neonatal patients with no suspected airway abnormalities; images were segmented to construct three-dimensional (3D) models of the neonatal airways. These models were then modified with virtual SGSs of varying %AO and axial positioning. CFD simulations of peak inspiratory flow were used to calculate patient-specific WOB in nonstenotic and artificially stenosed airway models. RESULTS: CFD simulations demonstrated a relationship between stenosis geometry and WOB increase. WOB rapidly increased with %AO greater than about 70%. Changes in axial position could also increase WOB by approximately the same amount as a 10% increase in %AO. Increased WOB was particularly pronounced when the SGS lumen was misaligned with the glottic jet. CONCLUSION: The results indicate a strong, predictable relationship between WOB and axial position of the stenotic lumen relative to the glottis, which has not been previously reported. These findings may lead to precision diagnosis and treatment prediction tools in individual patients. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:E1220-E1226, 2021.


Subject(s)
Laryngostenosis/diagnostic imaging , Laryngostenosis/physiopathology , Magnetic Resonance Imaging , Work of Breathing , Humans , Imaging, Three-Dimensional , Infant, Newborn , Patient-Specific Modeling
SELECTION OF CITATIONS
SEARCH DETAIL
...