Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-34790885

ABSTRACT

Disability is an important and often overlooked component of diversity. Individuals with disabilities bring a rare perspective to science, technology, engineering, mathematics, and medicine (STEMM) because of their unique experiences approaching complex issues related to health and disability, navigating the healthcare system, creatively solving problems unfamiliar to many individuals without disabilities, managing time and resources that are limited by physical or mental constraints, and advocating for themselves and others in the disabled community. Yet, individuals with disabilities are underrepresented in STEMM. Professional organizations can address this underrepresentation by recruiting individuals with disabilities for leadership opportunities, easing financial burdens, providing equal access, fostering peer-mentor groups, and establishing a culture of equity and inclusion spanning all facets of diversity. We are a group of deaf and hard-of-hearing (D/HH) engineers, scientists, and clinicians, most of whom are active in clinical practice and/or auditory research. We have worked within our professional societies to improve access and inclusion for D/HH individuals and others with disabilities. We describe how different models of disability inform our understanding of disability as a form of diversity. We address heterogeneity within disabled communities, including intersectionality between disability and other forms of diversity. We highlight how the Association for Research in Otolaryngology has supported our efforts to reduce ableism and promote access and inclusion for D/HH individuals. We also discuss future directions and challenges. The tools and approaches discussed here can be applied by other professional organizations to include individuals with all forms of diversity in STEMM.

2.
Otol Neurotol ; 42(10S): S2-S10, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34766938

ABSTRACT

HYPOTHESIS: This study tests the hypothesis that it is possible to find tone or noise vocoders that sound similar and result in similar speech perception scores to a cochlear implant (CI). This would validate the use of such vocoders as acoustic models of CIs. We further hypothesize that those valid acoustic models will require a personalized amount of frequency mismatch between input filters and output tones or noise bands. BACKGROUND: Noise or tone vocoders have been used as acoustic models of CIs in hundreds of publications but have never been convincingly validated. METHODS: Acoustic models were evaluated by single-sided deaf CI users who compared what they heard with the CI in one ear to what they heard with the acoustic model in the other ear. We evaluated frequency-matched models (both all-channel and 6-channel models, both tone and noise vocoders) as well as self-selected models that included an individualized level of frequency mismatch. RESULTS: Self-selected acoustic models resulted in similar levels of speech perception and similar perceptual quality as the CI. These models also matched the CI in terms of perceived intelligibility, harshness, and pleasantness. CONCLUSION: Valid acoustic models of CIs exist, but they are different from the models most widely used in the literature. Individual amounts of frequency mismatch may be required to optimize the validity of the model. This may be related to the basalward frequency mismatch experienced by postlingually deaf patients after cochlear implantation.


Subject(s)
Cochlear Implantation , Cochlear Implants , Speech Perception , Acoustic Stimulation/methods , Acoustics , Cochlear Implantation/methods , Humans , Noise
3.
Hear Res ; 377: 339-352, 2019 06.
Article in English | MEDLINE | ID: mdl-30867111

ABSTRACT

Auditory brainstem implants (ABIs) restore hearing to deaf individuals not eligible for cochlear implants. Speech comprehension in ABI users is generally poor compared to that of cochlear implant users, and side effects are common. The poor performance may result from activating broad areas and multiple neuronal populations of the cochlear nucleus, however detailed studies of the responses to surface stimulation of the cochlear nucleus are lacking. A conformable electrode array was microfabricated to fit on the rat's dorsal cochlear nucleus (DCN). It hosts 20 small electrodes (each 100 µm diam.). The array was tested by recording evoked potentials and neural activity along the tonotopic axis of the inferior colliculus (IC). Almost all bipolar electrode pairs elicited responses, in some cases with an even, or relatively constant, pattern of thresholds and supra-threshold measures along the long axis of the array. This pattern suggests that conformable arrays can provide relatively constant excitation along the surface of the DCN and thus might decrease the ABI side effects caused by spread of high current to adjacent structures. We also examined tonotopic patterns of the IC responses. Compared to sound-evoked responses, electrically-evoked response mappings had less tonotopic organization and were broader in width. They became more tonotopic when the evoked activity common to all electrodes and the late phase of response were subtracted out, perhaps because the remaining activity is from tonotopically organized principal cells of the DCN. Responses became less tonotopic when inter-electrode distance was increased from 400 µm to 800 µm but were relatively unaffected by changing to monopolar stimulation. The results illustrate the challenges of using a surface array to present tonotopic cues and improve speech comprehension in humans who use the ABI.


Subject(s)
Auditory Brain Stem Implants , Cochlear Nucleus/physiology , Evoked Potentials, Auditory, Brain Stem , Hearing , Inferior Colliculi/physiology , Acoustic Stimulation , Animals , Auditory Pathways/physiology , Electric Stimulation , Male , Materials Testing , Prosthesis Design , Rats, Sprague-Dawley
4.
Mol Ther ; 26(8): 1931-1939, 2018 08 01.
Article in English | MEDLINE | ID: mdl-30017876

ABSTRACT

Optogenetics is a transformative technology based on light-sensitive microbial proteins, known as opsins, that enable precise modulation of neuronal activity with pulsed radiant energy. Optogenetics has been proposed as a means to improve auditory implant outcomes by reducing channel interaction and increasing electrode density, but the introduction of opsins into cochlear spiral ganglion neurons (SGNs) in vivo has been challenging. Here we test opsin delivery using a synthetically developed ancestral adeno-associated virus (AAV) vector called Anc80L65. Wild-type C57BL/6 mouse pups were injected via the round window of cochlea with Anc80L65 carrying opsin Chronos under the control of a CAG promoter. Following an incubation of 6-22 weeks, pulsed blue light was delivered to cochlear SGNs via a cochleosotomy approach and flexible optical fiber. Optically evoked auditory brainstem responses (oABRs) and multiunit activity in inferior colliculus (IC) were observed. Post-experiment cochlear histology demonstrated opsin expression in SGNs (mean = 74%), with an even distribution of opsin along the cochlear basal/apical gradient. This study is the first to describe robust SGN transduction, opsin expression, and optically evoked auditory electrophysiology in neonatal mice. Ultimately, this work may provide the basis for a new generation of cochlear implant based on light.


Subject(s)
Genetic Vectors/administration & dosage , Opsins/genetics , Optogenetics/methods , Spiral Ganglion/metabolism , Animals , Animals, Newborn , Cochlear Implants , Dependovirus/genetics , Evoked Potentials, Auditory, Brain Stem , Humans , Mice , Mice, Inbred C57BL , Neurons/metabolism , Opsins/metabolism , Optical Fibers , Spiral Ganglion/physiology
5.
J Med Ethics ; 44(3): 174-179, 2018 03.
Article in English | MEDLINE | ID: mdl-28947504

ABSTRACT

OBJECTIVE: Cochlear explantation for purely elective (e.g. psychological and emotional) reasons is not well studied. Herein, we aim to provide data and expert commentary about elective cochlear implant (CI) removal that may help to guide clinical decision-making and formulate guidelines related to CI explantation. DATA SOURCES: We address these objectives via three approaches: case report of a patient who desired elective CI removal; review of literature and expert discussion by surgeon, audiologist, bioethicist, CI user and member of Deaf community. REVIEW METHODS: A systematic review using three scientific online databases was performed. Included articles addressed the benefits and/or complications of cochlear implantation in young children, CI explantation with or without revision surgery and the ethical debate between the medical and Deaf communities on cochlear implantation and explantation. CONCLUSIONS: The medical and audiological perspectives identify a host of risks related to implant removal without reimplantation, including risk from surgery, general anaesthesia, cochlear ossification and poor audiometric outcomes. The member of the deaf community and bioethicist argue that physicians need to guide the principles of beneficence, non-maleficence and patient autonomy. Taken together, patient desires should be seen as paramount, if the patient is otherwise fit for surgery and well informed. IMPLICATIONS FOR PRACTICE: Similar to the case of device implantation, device explantation should be a multidisciplinary and collaborative decision with the patient and the family's desires at the centre. While every case is different, we offer a CI explantation discussion to assist in clinical decision-making, patient counselling and education.


Subject(s)
Clinical Decision-Making/ethics , Cochlear Implantation , Cochlear Implants , Device Removal/ethics , Elective Surgical Procedures/ethics , Cochlear Implantation/psychology , Device Removal/psychology , Elective Surgical Procedures/psychology , Humans , Patient Education as Topic , Personal Autonomy
7.
Hear Res ; 322: 235-41, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25598479

ABSTRACT

Contemporary auditory brainstem implant (ABI) performance is limited by reliance on electrical neurostimulation with its accompanying channel cross talk and current spread to non-auditory neurons. A new generation ABI based on optogenetic technology may ameliorate limitations fundamental to electrical stimulation. The most widely studied opsin is channelrhodopsin-2 (ChR2); however, its relatively slow kinetic properties may prevent the encoding of auditory information at high stimulation rates. In the present study, we compare the temporal resolution of light-evoked responses of ChR2 to a recently developed fast opsin, Chronos, to ChR2 in a murine ABI model. Viral mediated gene transfer via a posterolateral craniotomy was used to express Chronos or ChR2 in the cochlear nucleus (CN). Following a four to eight week incubation period, blue light (473 nm) was delivered via an optical fiber placed directly on the surface of the infected CN, and neural activity was recorded in the contralateral inferior colliculus (IC). Both ChR2 and Chronos evoked sustained responses to all stimuli, even at high pulse rates. In addition, optical stimulation evoked excitatory responses throughout the tonotopic axis of the IC. Synchrony of the light-evoked response to stimulus rates of 14-448 pulses/s was higher in Chronos compared to ChR2 mice (p < 0.05 at 56, 168, and 224 pulses/s). Our results demonstrate that Chronos has the ability to drive the auditory system at higher stimulation rates than ChR2 and may be a more ideal opsin for manipulation of auditory pathways in future optogenetic-based neuroprostheses. This article is part of a Special Issue entitled "Lasker Award".


Subject(s)
Auditory Brain Stem Implants , Auditory Pathways/physiology , Cochlear Nucleus/physiology , Gene Transfer Techniques , Opsins/biosynthesis , Optogenetics , Rhodopsin/biosynthesis , Animals , Auditory Pathways/metabolism , Cochlear Nucleus/metabolism , Dependovirus/genetics , Evoked Potentials , Genetic Vectors , Kinetics , Light , Mice, Inbred CBA , Microinjections , Opsins/genetics , Photic Stimulation , Prosthesis Design , Rhodopsin/genetics
SELECTION OF CITATIONS
SEARCH DETAIL
...