Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
1.
Sci Data ; 11(1): 429, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38664431

ABSTRACT

While research has unveiled and quantified brain markers of abnormal neurodevelopment, clinicians still work with qualitative metrics for MRI brain investigation. The purpose of the current article is to bridge the knowledge gap between case-control cohort studies and individual patient care. Here, we provide a unique dataset of seventy-three 3-to-17 years-old healthy subjects acquired with a 6-minute MRI protocol encompassing T1 and T2 relaxation quantitative sequence that can be readily implemented in the clinical setting; MP2RAGE for T1 mapping and the prototype sequence GRAPPATINI for T2 mapping. White matter and grey matter volumes were automatically quantified. We further provide normative developmental curves based on these two imaging sequences; T1, T2 and volume normative ranges with respect to age were computed, for each ROI of a pediatric brain atlas. This open-source dataset provides normative values allowing to position individual patients acquired with the same protocol on the brain maturation curve and as such provides potentially useful quantitative biomarkers facilitating precise and personalized care.


Subject(s)
Brain , Magnetic Resonance Imaging , Humans , Brain/diagnostic imaging , Brain/growth & development , Child , Child, Preschool , Adolescent , Male , Female , White Matter/diagnostic imaging , White Matter/growth & development , Gray Matter/diagnostic imaging
2.
J Magn Reson Imaging ; 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38483105

ABSTRACT

BACKGROUND: Quantification of the T2 signal by means of T2 mapping in acute pancreatitis (AP) has the potential to quantify the parenchymal edema. Quantitative T2 mapping may overcome the limitations of previously reported scoring systems for reliable assessment of AP. PURPOSE: To evaluate MR-derived pancreatic T2 mapping values in AP and correlate them with markers of disease severity. STUDY TYPE: Prospective single-center study. POPULATION: 76 adults with AP (20-91 years, females/males: 39/37). FIELD STRENGTH/SEQUENCE: Fat suppressed multiecho spin-echo prototype sequence to quantify T2 signal at 3T MRI. ASSESSMENT: The severity of AP was assessed clinically, biologically, and by contrast-enhanced CT (CECT) performed 48-72 hours after symptom onset. MRI was then performed ≤24 hours after CT. Two readers blinded to any clinical information independently evaluated the T2 values by placing three regions of interest inside the pancreatic head, body, and tail on the T2 mapping MR sequence. Results were compared with corresponding CECT images as the standard and clinical severity parameters, using the length of hospital stay as our primary endpoint. STATISTICAL TESTS: Continuous variables were compared using the Spearman's rank correlation coefficient, analysis of variance (ANOVA) or Student's t-test. RESULTS: T2 values significantly correlated with the length of hospital stay (rs (74) = 0.29), CT severity index (CTSI) (rs (73) = 0.61; CTSI 0-3: 72 ± 14 msec, CTSI 4-10: 88 ± 15), intensive care unit (ICU) admission (t(2.77) = -3.41) and presence of organ failure (t(6.72) = -3.42), whereas the CTSI and Ranson score were not significantly related with ICU admission (CTSI: P = 0.24; Ranson score: P = 0.24) and organ failure (CTSI: P = 0.11; Ranson score P = 0.11). CONCLUSION: T2 mapping correlates with AP severity parameters and is useful for assessing the severity of AP with higher sensitivity than the usual clinical and radiological scoring systems. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.

3.
J Neurol ; 271(2): 631-641, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37819462

ABSTRACT

OBJECTIVES: Microstructural characterization of patients with multiple sclerosis (MS) has been shown to correlate better with disability compared to conventional radiological biomarkers. Quantitative MRI provides effective means to characterize microstructural brain tissue changes both in lesions and normal-appearing brain tissue. However, the impact of the location of microstructural alterations in terms of neuronal pathways has not been thoroughly explored so far. Here, we study the extent and the location of tissue changes probed using quantitative MRI along white matter (WM) tracts extracted from a connectivity atlas. METHODS: We quantified voxel-wise T1 tissue alterations compared to normative values in a cohort of 99 MS patients. For each WM tract, we extracted metrics reflecting tissue alterations both in lesions and normal-appearing WM and correlated these with cross-sectional disability and disability evolution after 2 years. RESULTS: In early MS patients, T1 alterations in normal-appearing WM correlated better with disability evolution compared to cross-sectional disability. Further, the presence of lesions in supratentorial tracts was more strongly associated with cross-sectional disability, while microstructural alterations in infratentorial pathways yielded higher correlations with disability evolution. In progressive patients, all major WM pathways contributed similarly to explaining disability, and correlations with disability evolution were generally poor. CONCLUSIONS: We showed that microstructural changes evaluated in specific WM pathways contribute to explaining future disability in early MS, hence highlighting the potential of tract-wise analyses in monitoring disease progression. Further, the proposed technique allows to estimate WM tract-specific microstructural characteristics in clinically compatible acquisition times, without the need for advanced diffusion imaging.


Subject(s)
Multiple Sclerosis , White Matter , Humans , Multiple Sclerosis/diagnostic imaging , Multiple Sclerosis/pathology , Cross-Sectional Studies , Brain/diagnostic imaging , Brain/pathology , Magnetic Resonance Imaging/methods , White Matter/diagnostic imaging , White Matter/pathology
5.
Front Oncol ; 13: 1117148, 2023.
Article in English | MEDLINE | ID: mdl-37564932

ABSTRACT

Objective: The application value of T2 mapping in evaluating endometrial carcinoma (EMC) features remains unclear. The aim of the study was to determine the quantitative T2 values in EMC using a novel accelerated T2 mapping, and evaluate them for detection, classification,and grading of EMC. Materials and methods: Fifty-six patients with pathologically confirmed EMC and 17 healthy volunteers were prospectively enrolled in this study. All participants underwent pelvic magnetic resonance imaging, including DWI and accelerated T2 mapping, before treatment. The T2 and apparent diffusion coefficient (ADC) values of different pathologic EMC features were extracted and compared. Receiver operating characteristic (ROC) curve analysis was performed to analyze the diagnostic efficacy of the T2 and ADC values in distinguishing different pathological features of EMC. Results: The T2 values and ADC values were significantly lower in EMC than in normal endometrium (bothl p < 0.05). The T2 and ADC values were significantly different between endometrioid adenocarcinoma (EA) and non-EA (both p < 0.05) and EMC tumor grades (all p < 0.05) but not for EMC clinical types (both p > 0.05) and depth of myometrial invasion (both p > 0.05). The area under the ROC curve (AUC) was higher for T2 values than for ADC values in predicting grade 3 EA (0.939 vs. 0.764, p = 0.048). When combined T2 and ADC values, the AUC for predicting grade 3 EA showed a significant increase to 0.947 (p = 0.03) compared with those of ADC values. The T2 and ADC values were negatively correlated with the tumor grades (r = -0.706 and r = -0.537, respectively). Conclusion: Quantitative T2 values demonstrate potential suitability in discriminating between EMC and normal endometrium, EA and non-EA, grade 3 EA and grade 1/2 EA. Combining T2 and ADC values performs better in predicting the histological grades of EA in comparison with ADC values alone.

6.
bioRxiv ; 2023 May 15.
Article in English | MEDLINE | ID: mdl-37425913

ABSTRACT

Functional magnetic resonance imaging (fMRI) is a methodological cornerstone of neuroscience. Most studies measure blood-oxygen-level-dependent (BOLD) signal using echo-planar imaging (EPI), Cartesian sampling, and image reconstruction with a one-to-one correspondence between the number of acquired volumes and reconstructed images. However, EPI schemes are subject to trade-offs between spatial and temporal resolutions. We overcome these limitations by measuring BOLD with a gradient recalled echo (GRE) with 3D radial-spiral phyllotaxis trajectory at a high sampling rate (28.24ms) on standard 3T field-strength. The framework enables the reconstruction of 3D signal time courses with whole-brain coverage at simultaneously higher spatial (1mm 3 ) and temporal (up to 250ms) resolutions, as compared to optimized EPI schemes. Additionally, artifacts are corrected before image reconstruction; the desired temporal resolution is chosen after scanning and without assumptions on the shape of the hemodynamic response. By showing activation in the calcarine sulcus of 20 participants performing an ON-OFF visual paradigm, we demonstrate the reliability of our method for cognitive neuroscience research.

7.
Magn Reson Med ; 90(6): 2348-2361, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37496187

ABSTRACT

PURPOSE: To develop SPARCQ (Signal Profile Asymmetries for Rapid Compartment Quantification), a novel approach to quantify fat fraction (FF) using asymmetries in the phase-cycled balanced SSFP (bSSFP) profile. METHODS: SPARCQ uses phase-cycling to obtain bSSFP frequency profiles, which display asymmetries in the presence of fat and water at certain TRs. For each voxel, the measured signal profile is decomposed into a weighted sum of simulated profiles via multi-compartment dictionary matching. Each dictionary entry represents a single-compartment bSSFP profile with a specific off-resonance frequency and relaxation time ratio. Using the results of dictionary matching, the fractions of the different off-resonance components are extracted for each voxel, generating quantitative maps of water and FF and banding-artifact-free images for the entire image volume. SPARCQ was validated using simulations, experiments in a water-fat phantom and in knees of healthy volunteers. Experimental results were compared with reference proton density FFs obtained with 1 H-MRS (phantoms) and with multiecho gradient-echo MRI (phantoms and volunteers). SPARCQ repeatability was evaluated in six scan-rescan experiments. RESULTS: Simulations showed that FF quantification is accurate and robust for SNRs greater than 20. Phantom experiments demonstrated good agreement between SPARCQ and gold standard FFs. In volunteers, banding-artifact-free quantitative maps and water-fat-separated images obtained with SPARCQ and ME-GRE demonstrated the expected contrast between fatty and non-fatty tissues. The coefficient of repeatability of SPARCQ FF was 0.0512. CONCLUSION: SPARCQ demonstrates potential for fat quantification using asymmetries in bSSFP profiles and may be a promising alternative to conventional FF quantification techniques.

8.
Neuroimage ; 276: 120173, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37201641

ABSTRACT

T1-weighted structural MRI is widely used to measure brain morphometry (e.g., cortical thickness and subcortical volumes). Accelerated scans as fast as one minute or less are now available but it is unclear if they are adequate for quantitative morphometry. Here we compared the measurement properties of a widely adopted 1.0 mm resolution scan from the Alzheimer's Disease Neuroimaging Initiative (ADNI = 5'12'') with two variants of highly accelerated 1.0 mm scans (compressed-sensing, CSx6 = 1'12''; and wave-controlled aliasing in parallel imaging, WAVEx9 = 1'09'') in a test-retest study of 37 older adults aged 54 to 86 (including 19 individuals diagnosed with a neurodegenerative dementia). Rapid scans produced highly reliable morphometric measures that largely matched the quality of morphometrics derived from the ADNI scan. Regions of lower reliability and relative divergence between ADNI and rapid scan alternatives tended to occur in midline regions and regions with susceptibility-induced artifacts. Critically, the rapid scans yielded morphometric measures similar to the ADNI scan in regions of high atrophy. The results converge to suggest that, for many current uses, extremely rapid scans can replace longer scans. As a final test, we explored the possibility of a 0'49'' 1.2 mm CSx6 structural scan, which also showed promise. Rapid structural scans may benefit MRI studies by shortening the scan session and reducing cost, minimizing opportunity for movement, creating room for additional scan sequences, and allowing for the repetition of structural scans to increase precision of the estimates.


Subject(s)
Alzheimer Disease , Humans , Aged , Alzheimer Disease/diagnosis , Reproducibility of Results , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Neuroimaging/methods
9.
Skeletal Radiol ; 52(11): 2185-2198, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37154871

ABSTRACT

Magnetic resonance imaging (MRI) is widely regarded as the primary modality for the morphological assessment of cartilage and all other joint tissues involved in osteoarthritis. 2D fast spin echo fat-suppressed intermediate-weighted (FSE FS IW) sequences with a TE between 30 and 40ms have stood the test of time and are considered the cornerstone of MRI protocols for clinical practice and trials. These sequences offer a good balance between sensitivity and specificity and provide appropriate contrast and signal within the cartilage as well as between cartilage, articular fluid, and subchondral bone. Additionally, FS IW sequences enable the evaluation of menisci, ligaments, synovitis/effusion, and bone marrow edema-like signal changes. This review article provides a rationale for the use of FSE FS IW sequences in the morphological assessment of cartilage and osteoarthritis, along with a brief overview of other clinically available sequences for this indication. Additionally, the article highlights ongoing research efforts aimed at improving FSE FS IW sequences through 3D acquisitions with enhanced resolution, shortened examination times, and exploring the potential benefits of different magnetic field strengths. While most of the literature on cartilage imaging focuses on the knee, the concepts presented here are applicable to all joints. KEY POINTS: 1. MRI is currently considered the modality of reference for a "whole-joint" morphological assessment of osteoarthritis. 2. Fat-suppressed intermediate-weighted sequences remain the keystone of MRI protocols for the assessment of cartilage morphology, as well as other structures involved in osteoarthritis. 3. Trends for further development in the field of cartilage and joint imaging include 3D FSE imaging, faster acquisition including AI-based acceleration, and synthetic imaging providing multi-contrast sequences.


Subject(s)
Cartilage, Articular , Osteoarthritis , Humans , Cartilage, Articular/diagnostic imaging , Cartilage, Articular/pathology , Knee Joint/pathology , Knee , Imaging, Three-Dimensional , Osteoarthritis/diagnostic imaging , Osteoarthritis/pathology , Magnetic Resonance Imaging/methods
10.
Heliyon ; 9(4): e15064, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37096006

ABSTRACT

Rationale and objectives: To prospectively evaluate feasibility and robustness of an accelerated T2 mapping sequence (GRAPPATINI) in brain imaging and to assess its synthetic T2-weighted images (sT2w) in comparison with a standard T2-weighted sequence (T2 TSE). Material and methods: Volunteers were included to evaluate the robustness and consecutive patients for morphological evaluation. They were scanned on a 3 T MR-scanner. Healthy volunteers underwent GRAPPATINI of the brain three times (day 1: scan/rescan; day 2: follow-up). Patients between the ages of 18 and 85 years who were able to provide written informed consent and who had no MRI contraindications were included. For morphological comparison two radiologists with 5 and 7 years of experience in brain MRI evaluated image quality using a Likert scale (1 being poor, 4 being excellent) in a blinded and randomized fashion. Results: Images were successfully acquired in ten volunteers with a mean age of 25 years (ranging from 22 to 31 years) and 52 patients (23 men/29 women) with a mean age of 55 years (range of 22-83 years). Most brain regions showed repeatable and reproducible T2 values (rescan: CoV 0.75%-2.06%, ICC 69%-92.3%; follow-up: CoV 0.41%-1.59%, ICC 79.4%-95.8%), except for the caudate nucleus (rescan: CoV 7.25%, ICC 66.3%; follow-up: CoV 4.78%, ICC 80.9%). Image quality of sT2w was rated inferior to T2 TSE (median for T2 TSE: 3; sT2w: 1-2), but measurements revealed good interrater reliability of sT2w (lesion counting: ICC 0.85; diameter measure: ICC 0.68 and 0.67). Conclusion: GRAPPATINI is a feasible and robust T2 mapping sequence of the brain on intra- and intersubject level. The resulting sT2w depict brain lesions comparable to T2 TSE despite its inferior image quality.

11.
Magn Reson Med ; 89(4): 1601-1616, 2023 04.
Article in English | MEDLINE | ID: mdl-36478417

ABSTRACT

PURPOSE: Studies at 3T have shown that T1 relaxometry enables characterization of brain tissues at the single-subject level by comparing individual physical properties to a normative atlas. In this work, an atlas of normative T1 values at 7T is introduced with 0.6 mm isotropic resolution and its clinical potential is explored in comparison to 3T. METHODS: T1 maps were acquired in two separate healthy cohorts scanned at 3T and 7T. Using transfer learning, a template-based brain segmentation algorithm was adapted to ultra-high field imaging data. After segmenting brain tissues, volumes were normalized into a common space, and an atlas of normative T1 values was established by modeling the T1 inter-subject variability. A method for single-subject comparisons restricted to white matter and subcortical structures was developed by computing Z-scores. The comparison was applied to eight patients scanned at both field strengths for proof of concept. RESULTS: The proposed method for morphometry delivered segmentation masks without statistically significant differences from those derived with the original pipeline at 3T and achieved accurate segmentation at 7T. The established normative atlas allowed characterizing tissue alterations in single-subject comparisons at 7T, and showed greater anatomical details compared with 3T results. CONCLUSION: A high-resolution quantitative atlas with an adapted pipeline was introduced and validated. Several case studies on different clinical conditions showed the feasibility, potential and limitations of high-resolution single-subject comparisons based on quantitative MRI atlases. This method in conjunction with 7T higher resolution broadens the range of potential applications of quantitative MRI in clinical practice.


Subject(s)
Magnetic Resonance Imaging , White Matter , Humans , Magnetic Resonance Imaging/methods , White Matter/diagnostic imaging , Algorithms , Brain/diagnostic imaging
12.
Eur Radiol ; 33(4): 2350-2357, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36396791

ABSTRACT

OBJECTIVE: To investigate the utility of an automatic deep learning (DL) method for segmentation of T2 maps in patients with idiopathic inflammatory myopathy (IIM) against healthy controls, and also the association of quantitative T2 values in patients with laboratory and pulmonary findings. METHODS: Structural MRI and T2 mapping of bilateral thigh muscles from patients with IIM and healthy volunteers were segmented using dedicated software based on a pre-trained convolutional neural network. Incremental and federated learning were implemented for continuous adaptation and improvement. Muscle T2 values derived from DL segmentation were compared between patients and healthy controls, and T2 values of patients were further analyzed with serum muscle enzymes, and interstitial lung disease (ILD) which was diagnosed and graded based on chest HRCT. RESULTS: Overall, 64 patients (27 patients with dermatomyositis, 29 with polymyositis, and 8 with antisynthetase syndrome (ASS)) and 10 healthy controls were included. By using DL-based muscle segmentation, T2 values generated from T2 maps accurately differentiated patients from those of controls (p < 0.001) with a cutoff value of 36.4 ms (sensitivity 96.9%, and specificity 100%). In patients with IIM, muscle T2 values positively correlated with all the serum muscle enzymes (all p < 0.05). ILD score of patients with ASS was markedly higher than that of those without ASS (p = 0.011), while dissociation between the severity of muscular involvement and ILD was observed (p = 0.080). CONCLUSION: Automatic DL could be used to segment thigh muscles and help quantitatively assess muscular inflammation of IIM through T2 mapping. KEY POINTS: • Muscle T2 mapping automatically segmented by deep learning can differentiate IIM from healthy controls. • T2 value, an indicator of active muscle inflammation, positively correlates with serum muscle enzymes. • T2 mapping can detect muscle disease in patients with normal muscle enzyme levels.


Subject(s)
Deep Learning , Lung Diseases, Interstitial , Myositis , Animals , Inflammation , Lung Diseases, Interstitial/diagnostic imaging , Muscle, Skeletal/diagnostic imaging , Myositis/diagnostic imaging
13.
Invest Radiol ; 58(1): 111-119, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36165990

ABSTRACT

ABSTRACT: This review summarizes the existing techniques and methods used to generate synthetic contrasts from magnetic resonance imaging data focusing on musculoskeletal magnetic resonance imaging. To that end, the different approaches were categorized into 3 different methodological groups: mathematical image transformation, physics-based, and data-driven approaches. Each group is characterized, followed by examples and a brief overview of their clinical validation, if present. Finally, we will discuss the advantages, disadvantages, and caveats of synthetic contrasts, focusing on the preservation of image information, validation, and aspects of the clinical workflow.


Subject(s)
Magnetic Resonance Imaging , Musculoskeletal System , Magnetic Resonance Imaging/methods , Workflow , Musculoskeletal System/diagnostic imaging
14.
medRxiv ; 2023 Dec 28.
Article in English | MEDLINE | ID: mdl-38234845

ABSTRACT

Measurement error limits the statistical power to detect group differences and longitudinal change in structural MRI morphometric measures (e.g., hippocampal volume, prefrontal thickness). Recent advances in scan acceleration enable extremely fast T1-weighted scans (~1 minute) to achieve morphometric errors that are close to the errors in longer traditional scans. As acceleration allows multiple scans to be acquired in rapid succession, it becomes possible to pool estimates to increase measurement precision, a strategy known as "cluster scanning." Here we explored brain morphometry using cluster scanning in a test-retest study of 40 individuals (12 younger adults, 18 cognitively unimpaired older adults, and 10 adults diagnosed with mild cognitive impairment or Alzheimer's Dementia). Morphometric errors from a single compressed sensing (CS) 1.0mm scan with 6x acceleration (CSx6) were, on average, 12% larger than a traditional scan using the Alzheimer's Disease Neuroimaging Initiative (ADNI) protocol. Pooled estimates from four clustered CSx6 acquisitions led to errors that were 34% smaller than ADNI despite having a shorter total acquisition time. Given a fixed amount of time, a gain in measurement precision can thus be achieved by acquiring multiple rapid scans instead of a single traditional scan. Errors were further reduced when estimates were pooled from eight CSx6 scans (51% smaller than ADNI). Neither pooling across a break nor pooling across multiple scan resolutions boosted this benefit. We discuss the potential of cluster scanning to improve morphometric precision, boost statistical power, and produce more sensitive disease progression biomarkers.

15.
Phys Med ; 103: 166-174, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36368208

ABSTRACT

PURPOSE: T1 Magnetization Prepared Two Rapid Acquisition Gradient Echo (MP2RAGE) with compress sensing (CS) has been proposed as an improvement of the standard MPRAGE sequence with multiple advantages including reduced acquisition time needed to provide a quantitative 3D anatomical image coupled with T1-map. Here we investigated the agreement between FreeSurfer-derived volume measurements obtained from MPRAGE and CS MP2RAGE acquisitions. METHODS: MPRAGE and CS MP2RAGE images of 37 subjects (14 patients with neurodegenerative disorders and 23 healthy controls) were acquired on a 3 T MR scanner and grey matter volumes were extracted using standard FreeSurfer parcellation. Lin's concordance correlation coefficient (Lin's CCC), Bland-Altman analysis, Passing-Bablok regression and DICE similarity coefficient were calculated to assess the agreement between the two. RESULTS: We found a good correspondence for most of the regions examined, with 93.5 % of them showing a mean DICE index >0.70. Poorer results were found with Lin's CCC especially for subcortical labels across patients. The Bland-Altman analysis showed CS MP2RAGE tended to measure lower cortical volumes compared to MPRAGE but in most cases the difference wasn't statistically relevant. The Passing-Bablock regression indicated overall an absence of systematic constant and proportional bias when CS MP2RAGE was used instead of MPRAGE. CONCLUSIONS: We found a good concordance for volumes obtained from MPRAGE and CS MP2RAGE images using FreeSurfer, suggesting a possible role of CS MP2RAGE for structural analysis with significant advantages like shorter acquisition time and the possibility to simultaneously obtain quantitative T1-maps of the brain enriching the diagnostic power of this technique.


Subject(s)
Breast Neoplasms , Magnetic Resonance Imaging , Humans , Female , Magnetic Resonance Imaging/methods , Gray Matter/diagnostic imaging , Brain/diagnostic imaging , Imaging, Three-Dimensional/methods
16.
Neuroimage ; 258: 119356, 2022 09.
Article in English | MEDLINE | ID: mdl-35659995

ABSTRACT

Tractography enables identifying and evaluating the healthy and diseased brain's white matter pathways from diffusion-weighted magnetic resonance imaging data. As previous evaluation studies have reported significant false-positive estimation biases, recent microstructure-informed tractography algorithms have been introduced to improve the trade-off between specificity and sensitivity. However, a major limitation for characterizing the performance of these techniques is the lack of ground truth brain data. In this study, we compared the performance of two relevant microstructure-informed tractography methods, SIFT2 and COMMIT, by assessing the subject specificity and reproducibility of their derived white matter pathways. Specifically, twenty healthy young subjects were scanned at eight different time points at two different sites. Subject specificity and reproducibility were evaluated using the whole-brain connectomes and a subset of 29 white matter bundles. Our results indicate that although the raw tractograms are more vulnerable to the presence of false-positive connections, they are highly reproducible, suggesting that the estimation bias is subject-specific. This high reproducibility was preserved when microstructure-informed tractography algorithms were used to filter the raw tractograms. Moreover, the resulting track-density images depicted a more uniform coverage of streamlines throughout the white matter, suggesting that these techniques could increase the biological meaning of the estimated fascicles. Notably, we observed an increased subject specificity by employing connectivity pre-processing techniques to reduce the underlaying noise and the data dimensionality (using principal component analysis), highlighting the importance of these tools for future studies. Finally, no strong bias from the scanner site or time between measurements was found. The largest intraindividual variance originated from the sole repetition of data measurements (inter-run).


Subject(s)
Connectome , White Matter , Adult , Diffusion Tensor Imaging , False Positive Reactions , Female , Humans , Male , Reproducibility of Results , White Matter/anatomy & histology , White Matter/diagnostic imaging , White Matter/physiology , Young Adult
17.
Neuroimage Clin ; 34: 103009, 2022.
Article in English | MEDLINE | ID: mdl-35561554

ABSTRACT

OBJECTIVE: Pathology in multiple sclerosis is not homogenously distributed. Recently, it has been shown that structures adjacent to CSF are more severely affected. A gradient of brain tissue involvement was shown with more severe pathology in periventricular areas and in proximity to brain surfaces such as the subarachnoid spaces and ependyma, and hence termed the "surface-in" gradient. Here, we study whether (i) the surface-in gradient of periventricular tissue alteration measured by T1 relaxometry is already present in early multiple sclerosis patients, (ii) how it differs between early and progressive multiple sclerosis patients, and (iii) whether the gradient-derived metrics in normal-appearing white matter and lesions correlate better with physical disability than conventional MRI-based metrics. METHODS: Forty-seven patients with early multiple sclerosis, 52 with progressive multiple sclerosis, and 92 healthy controls were included in the study. Isotropic 3D T1 relaxometry maps were obtained using the Magnetization-Prepared 2 Rapid Acquisition Gradient Echoes sequence at 3 T. After spatially normalizing the T1 maps into a study-specific common space, T1 inter-subject variability within the healthy cohort was modelled voxel-wise, yielding a normative T1 atlas. Individual comparisons of each multiple sclerosis patient against the atlas were performed by computing z-scores. Equidistant bands of voxels were defined around the ventricles in the supratentorial white matter; the z-scores in these bands were analysed and compared between the early and progressive multiple sclerosis cohorts. Correlations between both conventional and z-score-gradient-derived MRI metrics and the Expanded Disability Status Scale were assessed. RESULTS: Patients with early and progressive multiple sclerosis demonstrated a periventricular gradient of T1 relaxation time z-scores. In progressive multiple sclerosis, z-score-derived metrics reflecting the gradient of tissue abnormality in normal-appearing white matter were more strongly correlated with disability (maximal rho = 0.374) than the conventional lesion volume and count (maximal rho = 0.189 and 0.21 respectively). In early multiple sclerosis, the gradient of normal-appearing white matter volume with z-scores > 2 at baseline correlated with clinical disability assessed at two years follow-up. CONCLUSION: Our results suggest that the surface-in white matter gradient of tissue alteration is detectable with T1 relaxometry and is already present at clinical disease onset. The periventricular gradients correlate with clinical disability. The periventricular gradient in normal-appearing white matter may thus qualify as a promising biomarker for monitoring of disease activity from an early stage in all phenotypes of multiple sclerosis.


Subject(s)
Multiple Sclerosis , White Matter , Brain/diagnostic imaging , Brain/pathology , Humans , Magnetic Resonance Imaging/methods , Multiple Sclerosis/diagnostic imaging , Multiple Sclerosis/pathology , Multiple Sclerosis, Chronic Progressive/pathology , White Matter/diagnostic imaging , White Matter/pathology
18.
Sci Rep ; 12(1): 8682, 2022 05 23.
Article in English | MEDLINE | ID: mdl-35606398

ABSTRACT

Accurate characterization of in utero human brain maturation is critical as it involves complex and interconnected structural and functional processes that may influence health later in life. Magnetic resonance imaging is a powerful tool to investigate equivocal neurological patterns during fetal development. However, the number of acquisitions of satisfactory quality available in this cohort of sensitive subjects remains scarce, thus hindering the validation of advanced image processing techniques. Numerical phantoms can mitigate these limitations by providing a controlled environment with a known ground truth. In this work, we present FaBiAN, an open-source Fetal Brain magnetic resonance Acquisition Numerical phantom that simulates clinical T2-weighted fast spin echo sequences of the fetal brain. This unique tool is based on a general, flexible and realistic setup that includes stochastic fetal movements, thus providing images of the fetal brain throughout maturation comparable to clinical acquisitions. We demonstrate its value to evaluate the robustness and optimize the accuracy of an algorithm for super-resolution fetal brain magnetic resonance imaging from simulated motion-corrupted 2D low-resolution series compared to a synthetic high-resolution reference volume. We also show that the images generated can complement clinical datasets to support data-intensive deep learning methods for fetal brain tissue segmentation.


Subject(s)
Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Brain/diagnostic imaging , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Phantoms, Imaging
19.
World J Urol ; 40(6): 1455-1461, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35357510

ABSTRACT

PURPOSE: Purpose of this study is to evaluate the diagnostic accuracy of quantitative T2/ADC values in differentiating between PCa and lesions showing non-specific inflammatory infiltrates and atrophy, features of chronic prostatitis, as the most common histologically proven differential diagnosis. METHODS: In this retrospective, single-center cohort study, we analyzed 55 patients suspected of PCa, who underwent mpMRI (3T) including quantitative T2 maps before robot-assisted mpMRI-TRUS fusion prostate biopsy. All prostate lesions were scored according to PI-RADS v2.1. Regions of interest (ROIs) were annotated in focal lesions and normal prostate tissue. Quantitative mpMRI values from T2 mapping and ADC were compared using two-tailed t tests. Receiver operating characteristic curves (ROCs) and cutoff were calculated to differentiate between PCa and chronic prostatitis. RESULTS: Focal lesions showed significantly lower ADC and T2 mapping values than normal prostate tissue (p < 0.001). PCa showed significantly lower ADC and T2 values than chronic prostatitis (p < 0.001). ROC analysis revealed areas under the receiver operating characteristic curves (AUCs) of 0.85 (95% CI 0.74-0.97) for quantitative ADC values and 0.84 (95% CI 0.73-0.96) for T2 mapping. A significant correlation between ADC and T2 values was observed (r = 0.70; p < 0.001). CONCLUSION: T2 mapping showed high diagnostic accuracy for differentiating between PCa and chronic prostatitis, comparable to the performance of ADC values.


Subject(s)
Prostatic Neoplasms , Prostatitis , Cohort Studies , Diffusion Magnetic Resonance Imaging , Humans , Image-Guided Biopsy , Magnetic Resonance Imaging , Male , Prostate/diagnostic imaging , Prostate/pathology , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Prostatitis/diagnostic imaging , Prostatitis/pathology , Retrospective Studies
20.
J Magn Reson Imaging ; 56(2): 413-422, 2022 08.
Article in English | MEDLINE | ID: mdl-35038203

ABSTRACT

BACKGROUND: Currently, multi-parametric prostate MRI (mpMRI) consists of a qualitative T2 , diffusion weighted, and dynamic contrast enhanced imaging. Quantification of T2 imaging might further standardize PCa detection and support artificial intelligence solutions. PURPOSE: To evaluate the value of T2 mapping to detect prostate cancer (PCa) and to differentiate PCa aggressiveness. STUDY TYPE: Retrospective single center cohort study. POPULATION: Forty-four consecutive patients (mean age 67 years; median PSA 7.9 ng/mL) with mpMRI and verified PCa by subsequent targeted plus systematic MR/ultrasound (US)-fusion biopsy from February 2019 to December 2019. FIELD STRENGTH/SEQUENCE: Standardized mpMRI at 3 T with an additionally acquired T2 mapping sequence. ASSESSMENT: Primary endpoint was the analysis of quantitative T2 values and contrast differences/ratios (CD/CR) between PCa and benign tissue. Secondary objectives were the correlation between T2 values, ISUP grade, apparent diffusion coefficient (ADC) value, and PI-RADS, and the evaluation of thresholds for differentiating PCa and clinically significant PCa (csPCa). STATISTICAL TESTS: Mann-Whitney test, Spearman's rank (rs ) correlation, receiver operating curves, Youden's index (J), and AUC were performed. Statistical significance was defined as P < 0.05. RESULTS: Median quantitative T2 values were significantly lower for PCa in PZ (85 msec) and PCa in TZ (75 msec) compared to benign PZ (141 msec) or TZ (97 msec) (P < 0.001). CD/CR between PCa and benign PZ (51.2/1.77), respectively TZ (19.8/1.29), differed significantly (P < 0.001). The best T2 -mapping threshold for PCa/csPCa detection was for TZ 81/86 msec (J = 0.929/1.0), and for PZ 110 msec (J = 0.834/0.905). Quantitative T2 values of PCa did not correlate significantly with the ISUP grade (rs  = 0.186; P = 0.226), ADC value (rs  = 0.138; P = 0.372), or PI-RADS (rs  = 0.132; P = 0.392). DATA CONCLUSION: Quantitative T2 values could differentiate PCa in TZ and PZ and might support standardization of mpMRI of the prostate. Different thresholds seem to apply for PZ and TZ lesions. However, in the present study quantitative T2 values were not able to indicate PCa aggressiveness. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.


Subject(s)
Prostate , Prostatic Neoplasms , Aged , Artificial Intelligence , Cohort Studies , Diffusion Magnetic Resonance Imaging/methods , Humans , Magnetic Resonance Imaging/methods , Male , Prostate/pathology , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...