Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Eur Radiol ; 34(4): 2183-2194, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37798407

ABSTRACT

OBJECTIVE: To investigate the relationship of followings for patients with moyamoya disease (MMD): arterial wall enhancement on vessel wall MRI (VW-MRI), cross-sectional area (CSA), time-of-flight MR angiography (MRA), age, locations from intracranial internal carotid artery (ICA) to proximal middle cerebral artery (MCA), disease progression, and transient ischemic attack (TIA). METHODS: Patients who underwent VW-MRI between October 2018 and December 2020 were enrolled in this retrospective study. We measured arterial wall enhancement (enhancement ratio, ER) and CSA at five sections of ICA and MCA. Also, we scored MRA findings. Multiple linear regression (MLR) analysis was performed to explore the associations between ER, age, MRA score, CSA, history of TIA, and surgical revascularization. RESULTS: We investigated 102 sides of 51 patients with MMD (35 women, 16 men, mean age 31 years ± 18 [standard deviation]). ER for MRA score 2 (signal discontinuity) was higher than ER for other scores in sections D (end of ICA) and E (proximal MCA) on MLR analysis. ER in section E was significantly higher in patients for MRA score 2 with TIA history than without. ER significantly increased as CSA increased in section E, which suggests ER becomes less in decreased CSA due to negative remodeling. CONCLUSION: Arterial wall enhancement in MMD varies by age, location, and disease progression. Arterial wall enhancement may be stronger in the progressive stage of MMD. Arterial wall enhancement increases with history of TIA at proximal MCA, which may indicate the progression of the disease. CLINICAL RELEVANCE STATEMENT: Arterial wall enhancement in moyamoya disease varies by age, location of arteries, and disease progression, and arterial wall enhancement may be used as an imaging biomarker of moyamoya disease. KEY POINTS: It has not been clarified what arterial wall enhancement in moyamoya disease represents. Arterial wall enhancement in moyamoya disease varies by age, location of arteries, and disease progression. Arterial wall enhancement in moyamoya disease increases as the disease progresses.


Subject(s)
Ischemic Attack, Transient , Moyamoya Disease , Male , Humans , Female , Adult , Moyamoya Disease/diagnostic imaging , Retrospective Studies , Ischemic Attack, Transient/diagnostic imaging , Magnetic Resonance Imaging/methods , Middle Cerebral Artery , Disease Progression
2.
Jpn J Radiol ; 41(11): 1255-1264, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37219717

ABSTRACT

PURPOSE: This study aimed to investigate the uptake characteristics of 18F-fluoromisonidazole (FMISO), in mutant-type isocitrate dehydrogenase (IDH-mutant, grade 3 and 4) and wild-type IDH (IDH-wildtype, grade 4) 2021 WHO classification adult-type diffuse gliomas. MATERIALS AND METHODS: Patients with grade 3 and 4 adult-type diffuse gliomas (n = 35) were included in this prospective study. After registering 18F-FMISO PET and MR images, standardized uptake value (SUV) and apparent diffusion coefficient (ADC) were evaluated in hyperintense areas on fluid-attenuated inversion recovery (FLAIR) imaging (HIA), and in contrast-enhanced tumors (CET) by manually placing 3D volumes of interest. Relative SUVmax (rSUVmax) and SUVmean (rSUVmean), 10th percentile of ADC (ADC10pct), mean ADC (ADCmean) were measured in HIA and CET, respectively. RESULTS: rSUVmean in HIA and rSUVmean in CET were significantly higher in IDH-wildtype than in IDH-mutant (P = 0.0496 and 0.03, respectively). The combination of FMISO rSUVmean in HIA and ADC10pct in CET, that of rSUVmax and ADC10pct in CET, that of rSUVmean in HIA and ADCmean in CET, were able to differentiate IDH-mutant from IDH-wildtype (AUC 0.80). When confined to astrocytic tumors except for oligodendroglioma, rSUVmax, rSUVmean in HIA and rSUVmean in CET were higher for IDH-wildtype than for IDH-mutant, but not significantly (P = 0.23, 0.13 and 0.14, respectively). The combination of FMISO rSUVmean in HIA and ADC10pct in CET was able to differentiate IDH-mutant (AUC 0.81). CONCLUSION: PET using 18F-FMISO and ADC might provide a valuable tool for differentiating between IDH mutation status of 2021 WHO classification grade 3 and 4 adult-type diffuse gliomas.


Subject(s)
Brain Neoplasms , Glioma , Humans , Adult , Isocitrate Dehydrogenase/genetics , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/genetics , Brain Neoplasms/pathology , Prospective Studies , Glioma/diagnostic imaging , Glioma/genetics , Glioma/pathology , Mutation , World Health Organization , Positron-Emission Tomography , Retrospective Studies
3.
Jpn J Radiol ; 41(11): 1216-1225, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37256470

ABSTRACT

PURPOSE: Neuromelanin-sensitive MRI (NM-MRI) has proven useful for diagnosing Parkinson's disease (PD) by showing reduced signals in the substantia nigra (SN) and locus coeruleus (LC), but requires a long scan time. The aim of this study was to assess the image quality and diagnostic performance of NM-MRI with a shortened scan time using a denoising approach with deep learning-based reconstruction (dDLR). MATERIALS AND METHODS: We enrolled 22 healthy volunteers, 22 non-PD patients and 22 patients with PD who underwent NM-MRI, and performed manual ROI-based analysis. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in ten healthy volunteers were compared among images with a number of excitations (NEX) of 1 (NEX1), NEX1 images with dDLR (NEX1 + dDLR) and 5-NEX images (NEX5). Acquisition times for NEX1 and NEX5 were 3 min 12 s and 15 min 58 s, respectively. Diagnostic performances using the contrast ratio (CR) of the SN (CR_SN) and LC (CR_LC) and those by visual assessment for differentiating PD from non-PD were also compared between NEX1 and NEX1 + dDLR. RESULTS: Image quality analyses revealed that SNRs and CNRs of the SN and LC in NEX1 + dDLR were significantly higher than in NEX1, and comparable to those in NEX5. In diagnostic performance analysis, areas under the receiver operating characteristic curve (AUC) using CR_SN and CR_LC of NEX1 + dDLR were 0.87 and 0.75, respectively, which had no significant difference with those of NEX1. Visual assessment showed improvement of diagnostic performance by applying dDLR. CONCLUSION: Image quality for NEX1 + dDLR was comparable to that of NEX5. dDLR has the potential to reduce scan time of NM-MRI without degrading image quality. Both 1-NEX NM-MRI with and without dDLR showed high AUCs for diagnosing PD by CR. The results of visual assessment suggest advantages of dDLR. Further tuning of dDLR would be expected to provide clinical merits in diagnosing PD.


Subject(s)
Deep Learning , Parkinson Disease , Humans , Magnetic Resonance Imaging/methods , Substantia Nigra , Melanins , Parkinson Disease/diagnostic imaging
4.
Eur J Radiol ; 159: 110658, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36571926

ABSTRACT

PURPOSE: The telomerase reverse transcriptase promoter (TERTp) mutation is an unfavorable prognostic factor in isocitrate dehydrogenase-wildtype (IDHwt) histologically lower-grade astrocytoma (LGA), which was incorporated as a key component in the WHO 2021 classification of IDHwt LGA, replacing histologic grades in the WHO 2016 classification. The purpose of this study was to identify the imaging characteristics predictive of TERTp mutations in IDHwt LGA. METHODS: This retrospective study was approved by our institutional review board. This single-center study retrospectively included 59 patients with pathologically confirmed IDHwt LGA with known TERTp mutation status. In addition to clinical information and morphological characteristics, semi-quantitative imaging biomarkers such as the tumor-to-normal ratio (T/N ratio) on 18F-FDG-PET, normalized apparent diffusion coefficient (nADC), and histogram parameters from normalized relative cerebral blood volume (nrCBV) maps were compared between (a) TERTp-wildtype and TERTp-mutant tumors or (b) grade II and grade III astrocytoma. A p value < 0.05 was considered significant. RESULTS: There were no significant differences in the conventional imaging findings, T/N ratio on FDG-PET, nrCBV or ADC histogram metrics between IDHwt LGA with TERTp mutations and those without. Grade III IDHwt astrocytomas exhibited significantly higher nrCBV values, T/N ratio and lower ADC parameters than grade II IDHwt astrocytoma. CONCLUSIONS: In patients with IDHwt LGA, T/N ratio, nrCBV values and nADC may be surrogate markers for predicting histologic grade, but are not useful for predicting TERTp mutations.


Subject(s)
Astrocytoma , Brain Neoplasms , Glioma , Telomerase , Humans , Astrocytoma/diagnostic imaging , Astrocytoma/genetics , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/genetics , Brain Neoplasms/pathology , Fluorodeoxyglucose F18 , Glioma/diagnostic imaging , Glioma/genetics , Glioma/pathology , Isocitrate Dehydrogenase/genetics , Mutation , Perfusion , Retrospective Studies , Telomerase/genetics
5.
Ann Nucl Med ; 37(4): 209-218, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36585566

ABSTRACT

OBJECTIVE: A mobile PET scanner termed flexible PET (fxPET) has been designed to fit existing MRI systems. The purpose of this study was to assess brain imaging with fxPET combined with 3-T MRI in comparison with conventional PET (cPET)/CT. METHODS: In this prospective study, 29 subjects with no visible lesions except for mild leukoaraiosis on whole brain imaging underwent 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) cPET/CT followed by fxPET and MRI. The registration differences between fxPET and MRI and between cPET and CT were compared by measuring spatial coordinates. Three-dimensional magnetization-prepared rapid acquisition gradient-echo T1-weighted imaging (T1WI) was acquired. We applied two methods of attenuation correction to the fxPET images: MR-based attenuation correction, which yielded fxPETMRAC; and CT-based attenuation correction, which yielded fxPETCTAC. The three PET datasets were co-registered to the T1WI. Following subcortical segmentation and cortical parcellation, volumes of interest were placed in each PET image to assess physiological accumulation in the brain. SUVmean was obtained and compared between the three datasets. We also visually evaluated image distortion and clarity of fxPETMRAC. RESULTS: Mean misregistration of fxPET/MRI was < 3 mm for each margin. Mean registration differences were significantly larger for fxPET/MRI than for cPET/CT except for the superior margin. There were high correlations between the three PET datasets regarding SUVmean. On visual evaluation of image quality, the grade of distortion was comparable between fxPETMRAC and cPET, and the grade of clarity was acceptable but inferior for fxPETMRAC compared with cPET. CONCLUSIONS: fxPET could successfully determine physiological [18F]FDG uptake; however, improved image clarity is desirable. In this study, fxPET/MRI at 3-T was feasible for brain imaging.


Subject(s)
Fluorodeoxyglucose F18 , Multimodal Imaging , Humans , Prospective Studies , Multimodal Imaging/methods , Positron-Emission Tomography/methods , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Neuroimaging
6.
Eur Radiol ; 33(6): 4488-4499, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36418626

ABSTRACT

OBJECTIVES: To evaluate susceptibility values associated with iron accumulation in the deep gray matter during postnatal development and to compare magnetic susceptibility between patients with normal and delayed development. METHODS: Patients with postmenstrual age (PMA) ≤ 1000 days underwent MR scans between August 2015 and April 2020 at our hospital. Quantitative susceptibility mapping (QSM) was performed, and magnetic susceptibility was measured using three-dimensional volumes of interest (VOIs) for the caudate nucleus (CN), globus pallidus (GP), putamen (PT), and ventrolateral thalamic nucleus (VL). Cross-sectional analysis was performed for 99 patients with normal development and 39 patients with delayed development. Longitudinal analysis was also performed to interpret changes over time in 13 patients with normal development. Correlations between magnetic susceptibility in VOIs and PMA or chronological age (CA) were assessed. RESULTS: Susceptibility values for CN, GP, PT, and VL showed positive moderate correlations with both PMA (ρ = 0.45, 0.69, 0.62, and 0.33, respectively) and CA (ρ = 0.53, 0.69, 0.66, and 0.39, respectively). The slope of the correlation between susceptibility values and age was highest in the GP among the four gray matter areas. Susceptibility values for the CN, GP, PT, and VL were higher with normal development than with delayed development at early postnatal age, although a significant difference was only observed for the CN. Susceptibility values also increased with age in the longitudinal analysis. CONCLUSIONS: Magnetic susceptibility values in deep gray matter increased with age ≤ 1000 days. The normal development group showed higher susceptibility values than the delayed development group at early postnatal age (PMA ≤ 285 days). KEY POINTS: • Magnetic susceptibilities in deep gray matter nuclei increased with age (postmenstrual age ≤ 1000 days) in a large number of pediatric patients. • The normal development group showed higher susceptibility values than the delayed development group in the basal ganglia and ventrolateral thalamic nucleus at early postnatal age (PMA ≤ 285 days).


Subject(s)
Gray Matter , Magnetic Resonance Imaging , Humans , Child , Gray Matter/diagnostic imaging , Magnetic Resonance Imaging/methods , Cross-Sectional Studies , Iron , Caudate Nucleus , Brain Mapping/methods , Brain/diagnostic imaging
7.
Eur Radiol ; 33(4): 2895-2904, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36422648

ABSTRACT

OBJECTIVES: To assess the accuracy, repeatability, and reproducibility of T1 and T2 relaxation time measurements by three-dimensional magnetic resonance fingerprinting (3D MRF) using various dictionary resolutions. METHODS: The ISMRM/NIST phantom was scanned daily for 10 days in two 3 T MR scanners using a 3D MRF sequence reconstructed using four dictionaries with varying step sizes and one dictionary with wider ranges. Thirty-nine healthy volunteers were enrolled: 20 subjects underwent whole-brain MRF scans in both scanners and the rest in one scanner. ROI/VOI analyses were performed on phantom and brain MRF maps. Accuracy, repeatability, and reproducibility metrics were calculated. RESULTS: In the phantom study, all dictionaries showed high T1 linearity to the reference values (R2 > 0.99), repeatability (CV < 3%), and reproducibility (CV < 3%) with lower linearity (R2 > 0.98), repeatability (CV < 6%), and reproducibility (CV ≤ 4%) for T2 measurement. The volunteer study demonstrated high T1 reproducibility of within-subject CV (wCV) < 4% by all dictionaries with the same ranges, both in the brain parenchyma and CSF. Yet, reproducibility was moderate for T2 measurement (wCV < 8%). In CSF measurement, dictionaries with a smaller range showed a seemingly better reproducibility (T1, wCV 3%; T2, wCV 8%) than the much wider range dictionary (T1, wCV 5%; T2, wCV 13%). Truncated CSF relaxometry values were evident in smaller range dictionaries. CONCLUSIONS: The accuracy, repeatability, and reproducibility of 3D MRF across various dictionary resolutions were high for T1 and moderate for T2 measurements. A lower-resolution dictionary with a well-defined range may be adequate, thus significantly reducing the computational load. KEY POINTS: • A lower-resolution dictionary with a well-defined range may be sufficient for 3D MRF reconstruction. • CSF relaxation times might be underestimated due to truncation by the upper dictionary range. • Dictionary with a higher upper range might be advisable, especially for CSF evaluation and elderly subjects whose perivascular spaces are more prominent.


Subject(s)
Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Humans , Aged , Image Processing, Computer-Assisted/methods , Reproducibility of Results , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Brain/diagnostic imaging , Phantoms, Imaging
8.
Eur Radiol ; 33(2): 936-946, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36006430

ABSTRACT

OBJECTIVES: To develop a generative adversarial network (GAN) model to improve image resolution of brain time-of-flight MR angiography (TOF-MRA) and to evaluate the image quality and diagnostic utility of the reconstructed images. METHODS: We included 180 patients who underwent 1-min low-resolution (LR) and 4-min high-resolution (routine) brain TOF-MRA scans. We used 50 patients' datasets for training, 12 for quantitative image quality evaluation, and the rest for diagnostic validation. We modified a pix2pix GAN to suit TOF-MRA datasets and fine-tuned GAN-related parameters, including loss functions. Maximum intensity projection images were generated and compared using multi-scale structural similarity (MS-SSIM) and information theoretic-based statistic similarity measure (ISSM) index. Two radiologists scored vessels' visibilities using a 5-point Likert scale. Finally, we evaluated sensitivities and specificities of GAN-MRA in depicting aneurysms, stenoses, and occlusions. RESULTS: The optimal model was achieved with a lambda of 1e5 and L1 + MS-SSIM loss. Image quality metrics for GAN-MRA were higher than those for LR-MRA (MS-SSIM, 0.87 vs. 0.73; ISSM, 0.60 vs. 0.35; p.adjusted < 0.001). Vessels' visibility of GAN-MRA was superior to LR-MRA (rater A, 4.18 vs. 2.53; rater B, 4.61 vs. 2.65; p.adjusted < 0.001). In depicting vascular abnormalities, GAN-MRA showed comparable sensitivities and specificities, with greater sensitivity for aneurysm detection by one rater (93% vs. 84%, p < 0.05). CONCLUSIONS: An optimized GAN could significantly improve the image quality and vessel visibility of low-resolution brain TOF-MRA with equivalent sensitivity and specificity in detecting aneurysms, stenoses, and occlusions. KEY POINTS: • GAN could significantly improve the image quality and vessel visualization of low-resolution brain MR angiography (MRA). • With optimally adjusted training parameters, the GAN model did not degrade diagnostic performance by generating substantial false positives or false negatives. • GAN could be a promising approach for obtaining higher resolution TOF-MRA from images scanned in a fraction of time.


Subject(s)
Brain , Magnetic Resonance Angiography , Humans , Magnetic Resonance Angiography/methods , Constriction, Pathologic , Brain/diagnostic imaging , Brain/blood supply , Magnetic Resonance Imaging , Cerebral Angiography/methods
9.
Magn Reson Med Sci ; 2022 Dec 13.
Article in English | MEDLINE | ID: mdl-36517008

ABSTRACT

Hemorrhage inside the mammillary bodies (MMBs) is known to be one of the findings of Wernicke encephalopathy. Brain MRI of two patients with Wernicke-Korsakoff syndrome (WKS) demonstrated high susceptibility values representing hemosiderin deposition in MMBs by using quantitative susceptibility mapping (QSM). QSM provided additional information of susceptibility values to susceptibility-weighted imaging in diagnosis of WKS.

10.
Sci Rep ; 12(1): 17689, 2022 10 21.
Article in English | MEDLINE | ID: mdl-36271294

ABSTRACT

Diffusion-weighted magnetic resonance imaging is prone to have susceptibility artifacts in an inhomogeneous magnetic field. We compared distortion and artifacts among three diffusion acquisition techniques (single-shot echo-planar imaging [SS-EPI DWI], readout-segmented EPI [RESOLVE DWI], and 2D turbo gradient- and spin-echo diffusion-weighted imaging with non-Cartesian BLADE trajectory [TGSE-BLADE DWI]) in healthy volunteers and in patients with a cerebral aneurysm clip. Seventeen healthy volunteers and 20 patients who had undergone surgical cerebral aneurysm clipping were prospectively enrolled. SS-EPI DWI, RESOLVE DWI, and TGSE-BLADE DWI of the brain were performed using 3 T scanners. Distortion was the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI near air-bone interfaces in healthy volunteers (P < 0.001). Length of clip-induced artifact and distortion near the metal clip were the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI (P < 0.01). Image quality scores for geometric distortion, susceptibility artifacts, and overall image quality in both healthy volunteers and patients were the best in TGSE-BLADE DWI, and better in RESOLVE DWI than SS-EPI DWI (P < 0.001). Among the three DWI sequences, image quality was the best in TGSE-BLADE DWI in terms of distortion and artifacts, in both healthy volunteers and patients with an aneurysm clip.


Subject(s)
Echo-Planar Imaging , Intracranial Aneurysm , Humans , Echo-Planar Imaging/methods , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Healthy Volunteers , Reproducibility of Results , Surgical Instruments
11.
Radiol Med ; 127(9): 1032-1045, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35907157

ABSTRACT

Vessel wall MR imaging (VW-MRI) has been introduced into clinical practice and applied to a variety of diseases, and its usefulness has been reported. High-resolution VW-MRI is essential in the diagnostic workup and provides more information than other routine MR imaging protocols. VW-MRI is useful in assessing lesion location, morphology, and severity. Additional information, such as vessel wall enhancement, which is useful in the differential diagnosis of atherosclerotic disease and vasculitis could be assessed by this special imaging technique. This review describes the VW-MRI technique and its clinical applications in arterial disease, venous disease, vasculitis, and leptomeningeal disease.


Subject(s)
Magnetic Resonance Imaging , Vasculitis , Humans , Magnetic Resonance Angiography/methods , Magnetic Resonance Imaging/methods
12.
Eur J Radiol ; 151: 110294, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35427840

ABSTRACT

PURPOSE: The aim of this study was to examine the evaluation of ultra-high-resolution computed tomography angiography (UHR CTA) images in moyamoya disease (MMD) reconstructed with hybrid iterative reconstruction (Hybrid-IR), model-based iterative reconstruction (MBIR), and deep learning reconstruction (DLR). METHODS: This retrospective study with institutional review board approval included patients with clinically suspected MMD who underwent UHR CTA between January 2018 and July 2020. CTA images were reconstructed with three reconstruction methods. Qualitative visualization was evaluated in comparison with digital subtraction angiography. Quantitative evaluation included assessment of edge sharpness, full width at half maximum (FWHM), vessel contrast, and tissue signal-to-noise ratio (SNRtissue). One-way analysis of variance was used to analyze differences. In addition, reconstruction time were assessed. RESULTS: Qualitative evaluation of CTA for 33 sides did not differ significantly between reconstruction methods. In quantitative evaluation for 54 patients, edge sharpness for right and left cortical segments of the middle cerebral artery was significantly higher for Hybrid-IR than for other reconstructions. No significant difference was seen between MBIR and DLR. Edge sharpness for STA-MCA bypass was significantly higher for Hybrid-IR than for MBIR, but no significant difference was seen between Hybrid-IR and DLR. FWHM for STA-MCA showed no significant difference between the three reconstruction methods. DLR displayed the highest SNRtissue. The time required for reconstruction was 40 s for Hybrid-IR, 2580 s for MBIR, and 180 s for DLR. CONCLUSION: UHR CTA with DLR adequately visualized vessels in patients with MMD within a clinically feasible reconstruction time.


Subject(s)
Deep Learning , Moyamoya Disease , Algorithms , Computed Tomography Angiography , Humans , Moyamoya Disease/diagnostic imaging , Moyamoya Disease/surgery , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Retrospective Studies
13.
Eur Radiol ; 32(8): 5392-5401, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35298680

ABSTRACT

OBJECTIVES: To assess the feasibility of low-dose contrast-enhanced four-dimensional (4D) time-resolved angiography with stochastic trajectories (TWIST) with iterative reconstruction (hereafter IT-TWIST-MRA) covering the whole brain and to compare IT-TWIST-MRA and TWIST-MRA with reference to digital subtraction angiography (DSA) in the evaluation of arteriovenous shunts (AVS). METHODS: Institutional Review Board approval was obtained for this observational study, and the requirement for written informed consent was waived. Twenty-nine patients with known AVS underwent TWIST-MRA on a 3-T MRI scanner, using low-dose injection (0.02 mmol/kg) of gadolinium-based contrast agent (GBCA) with each of Fourier and iterative reconstruction between September 2016 and October 2019. Visual evaluation of image quality was conducted for delineation of (a) the normal cerebral arteries and veins and (b) AVS feeder, shunt, and drainer vessels. Region-of-interest evaluation was conducted to evaluate bolus sharpness and baseline signal fluctuation in the signal intensity of the cerebral vessels. We compared the detection of AVS between TWIST-MRA and IT-TWIST-MRA. The paired-samples Wilcoxon test was used to test the differences between TWIST-MRA and IT-TWIST-MRA. RESULTS: Visualization scores for normal vasculature and AVS angioarchitecture were significantly better for images produced using IT-TWIST-MRA than those using TWIST-MRA. Peak signal and the enhancement slope of the time-intensity curve were significantly higher for IT-TWIST-MRA than for TWIST-MRA, except for the superior sagittal sinus (SSS). Baseline intensity fluctuation was significantly lower for IT-TWIST-MRA than for TWIST, except for SSS. CONCLUSIONS: IT-TWIST-MRA yields clinically feasible 4D MR-DSA images and delineates AVS even with low-dose GBCA. KEY POINTS: • Iterative reconstruction significantly improves the image quality of TWIST-MRA covering the whole brain. • The short temporal footprint and denoising effect of iterative reconstruction enhances the quality of 4D-MRA. • IT-TWIST-MRA yields clinically feasible images of AVS with low-dose GBCA.


Subject(s)
Image Enhancement , Magnetic Resonance Angiography , Angiography, Digital Subtraction , Brain , Contrast Media/pharmacology , Humans , Image Enhancement/methods , Magnetic Resonance Angiography/methods , Tomography, X-Ray Computed
14.
Magn Reson Med Sci ; 21(4): 633-647, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-34602534

ABSTRACT

PURPOSE: To compare reliability and elucidate clinical application of magnetization-prepared rapid gradient-echo (MPRAGE) with 9-fold acceleration by using wave-controlled aliasing in parallel imaging (Wave-CAIPI 3 × 3) in comparison to conventional MPRAGE accelerated by using generalized autocalibrating partially parallel acquisition (GRAPPA) 2 × 1. METHODS: A total of 26 healthy volunteers and 33 patients were included in this study. Subjects were scanned with two MPRAGEs, GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 acquired in 5 min 21 s and 1 min 42 s, respectively, on a 3T MR scanner. Healthy volunteers underwent additional two MPRAGEs (CAIPI 3 × 3 and GRAPPA 3 × 3). The image quality of the four MPRAGEs was visually evaluated with a 5-point scale in healthy volunteers, and the SNR of four MPRAGEs was also calculated by measuring the phantom 10 times with each MPRAGE. Based on the results of the visual evaluation, voxel-based morphometry (VBM) analyses, including subfield analysis, were performed only for GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. Correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was assessed. RESULTS: In visual evaluations, scores for MPRAGE GRAPPA 2 × 1 (mean rank: 4.00) were significantly better than those for Wave-CAIPI 3 × 3 (mean rank: 3.00), CAIPI 3 × 3 (mean rank: 1.83), and GRAPPA 3 × 3 (mean rank: 1.17), and scores for Wave-CAIPI 3×3 were significantly better than those for CAIPI 3 × 3 and GRAPPA 3 × 3. Image noise was evident at the center for additional MPRAGE CAIPI 3 × 3 and GRAPPA 3 × 3. The correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was higher than 0.85 in all VOIs except globus pallidus. Subfield analysis of hippocampus also showed a high correlation between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. CONCLUSION: MPRAGE Wave-CAIPI 3 × 3 shows relatively better contrast, despite of its short scan time of 1 min 42 s. The volumes derived from automated segmentation of MPRAGE Wave-CAIPI are considered to be reliable measures.


Subject(s)
Artifacts , Image Enhancement , Algorithms , Humans , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Reproducibility of Results
15.
Magn Reson Med Sci ; 21(4): 583-591, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-34334585

ABSTRACT

PURPOSE: Diffusion-weighted MRI (DWI) is an essential sequence for evaluating pediatric patients with moyamoya disease (MMD); however, acoustic noise associated with DWI may lead to motion artifact. Compared with conventional DWI (cDWI), quiet DWI (qDWI) is considered less noisy and able to keep children more relaxed and stable. This study aimed to evaluate the suitability of qDWI compared with cDWI for pediatric patients with MMD. METHODS: In this observational study, MR examinations of the brain were performed either with or without sedation in pediatric patients with MMD between September 2017 and August 2018. Three neuroradiologists independently evaluated the images for artifacts and restricted diffusion in the brain. The differences between qDWI and cDWI were compared statistically using a chi-square test. RESULTS: One-hundred and six MR scans of 56 patients with MMD (38 scans of 15 sedated patients: 6 boys and 9 girls; mean age, 5.2 years; range, 1-9 years; and 68 scans of 42 unsedated patients: 19 boys and 23 girls; mean age, 10.7 years; range, 7-16 years) were evaluated. MR examinations were performed either with or without sedation (except in one patient). In sedated patients, no artifact other than susceptibility was observed on qDWI, whereas four artifacts were observed on cDWI (P = .04). One patient awoke from sedation during cDWI scanning, while no patient awoke from sedation during qDWI acquisition. For unsedated patients, three scans showed artifacts on qDWI, whereas two scans showed artifacts on cDWI (P = .65). Regarding restricted diffusion, qDWI revealed three cases, while two cases were found on cDWI (P = .66). CONCLUSION: qDWI induced fewer artifacts compared with cDWI in sedated patients, and similar frequencies of artifacts were induced by qDWI and by cDWI in unsedated patients. qDWI showed restricted diffusion comparable to cDWI.


Subject(s)
Image Interpretation, Computer-Assisted , Moyamoya Disease , Artifacts , Brain/diagnostic imaging , Child , Child, Preschool , Diffusion Magnetic Resonance Imaging/methods , Female , Humans , Image Interpretation, Computer-Assisted/methods , Male , Moyamoya Disease/diagnostic imaging
16.
Jpn J Radiol ; 39(7): 669-680, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33641056

ABSTRACT

PURPOSE: To evaluate the clinical feasibility of a newly developed mobile PET system with MR-compatibility (flexible PET; fxPET), compared with conventional PET (cPET)/CT for brain imaging. METHODS: Twenty-one patients underwent cPET/CT with subsequent fxPET/MRI using 18F-FDG. As qualitative evaluation, we visually rated image quality of MR and PET images using a four-point scoring system. We evaluated overall image quality for MR, while we evaluated overall image quality, sharpness and lesion contrast. As quantitative evaluation, we compared registration accuracy between two modalities [(fxPET and MRI) and (cPET and CT)] measuring spatial coordinates. We also examined the accuracy of regional 18F-FDG uptake. RESULTS: All acquired images were of diagnostic quality and the number of detected lesions did not differ significantly between fxPET/MR and cPET/CT. Mean misregistration was significantly larger with fxPET/MRI than with cPET/CT. SUVmax and SUVmean for fxPET and cPET showed high correlations in the lesions (R = 0.84, 0.79; P < 0.001, P = 0.002, respectively). In normal structures, we also showed high correlations of SUVmax (R = 0.85, 0.87; P < 0.001, P < 0.001, respectively) and SUVmean (R = 0.83, 0.87; P < 0.001, P < 0.001, respectively) in bilateral caudate nuclei and a moderate correlation of SUVmax (R = 0.65) and SUVmean (R = 0.63) in vermis. CONCLUSIONS: The fxPET/MRI system showed image quality within the diagnostic range, registration accuracy below 3 mm and regional 18F-FDG uptake highly correlated with that of cPET/CT.


Subject(s)
Brain Diseases/diagnosis , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Multimodal Imaging/methods , Positron-Emission Tomography/instrumentation , Tomography, X-Ray Computed/methods , Whole Body Imaging/methods , Adult , Aged , Feasibility Studies , Female , Humans , Male , Middle Aged , Neuroimaging/methods , Young Adult
17.
J Magn Reson Imaging ; 53(4): 1151-1161, 2021 04.
Article in English | MEDLINE | ID: mdl-33067897

ABSTRACT

BACKGROUND: Hypothalamic-pituitary-thyroid (HPT) maturation has not been extensively evaluated using neonatal MRI, even though both structures are visualized on MRI. HYPOTHESIS: That signal intensity and volume of pituitary and thyroid (T) glands on MRI in neonates may be interrelated. STUDY TYPE: Retrospective. SUBJECTS: In all, 102 participants. FIELD STRENGTH/SEQUENCE: 3.0T, T1 -weighted pointwise encoding time reduction with radial acquisition (PETRA). ASSESSMENT: The volume of interest of the anterior pituitary (AP), posterior pituitary (PP), and T on MRI were defined on T1 -PETRA by two radiologists, and volumes of AP (AP_vol) and thyroid (T_vol) were calculated. Gestational age (GA), chronological age (CA), GA+CA, birth weight (BW), and thyroid function were recorded. Mean and maximum signal intensities of AP, PP, and T were normalized using signals from the pons and spinal cord as follows: signal ratio of anterior pituitary/pons (AP/pons), signal ratio of posterior pituitary/pons (PP/pons), and signal ratio of thyroid/cord (T/cord) T/cord, respectively. STATISTICAL TESTS: Correlations between signal intensity and volume measures and GA, CA, GA+CA, and BW were assessed using Pearson's correlation coefficient or Spearman's rank correlation coefficient. Thyroid function analysis and Tmean /cord, Tmax /cord, and T_vol were evaluated using the Steel-Dwass test. RESULTS: APmean /pons correlated positively with GA (ρ = 0.62, P < 0.001) and BW (ρ = 0.74, P < 0.001), and negatively with CA (ρ = -0.86, P < 0.001) and GA+CA (ρ = -0.46, P < 0.001). PPmean /pons correlated positively with GA (ρ = 0.49, P < 0.001) and BW (ρ = 0.63, P < 0.001), and negatively with CA (ρ = -0.70, P < 0.001) and GA+CA (r = -0.38, P < 0.001). Tmean /cord correlated positively with GA (ρ = 0.48, P < 0.001) and BW (ρ = 0.55, P < 0.001), and negatively with CA (ρ = -0.59, P < 0.001) and GA+CA (ρ = -0.22, P = 0.03). AP_vol correlated positively with GA (ρ = 0.68, P < 0.001) and BW (ρ = 0.73, P < 0.001), and negatively with CA (ρ = -0.72, P < 0.001). T_vol correlated positively with GA (ρ = 0.50, P < 0.001) and BW (ρ = 0.61, P < 0.001), and negatively with CA (ρ = -0.54, P < 0.001). APmean /pons correlated positively with Tmean /cord (ρ = 0.61, P < 0.001). DATA CONCLUSION: Signal and volume of pituitary and thyroid glands correlated positively with GA and BW, and negatively with CA in neonates. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY STAGE: 5.


Subject(s)
Magnetic Resonance Imaging , Thyroid Gland , Birth Weight , Gestational Age , Humans , Infant , Infant, Newborn , Retrospective Studies , Thyroid Gland/diagnostic imaging
18.
Neuroradiology ; 63(6): 879-887, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33063222

ABSTRACT

PURPOSE: Time-of-flight (TOF)-MR angiography (MRA) is an important imaging sequence for the surveillance and analysis of cerebral arteriovenous shunt (AVS), including arteriovenous malformation (AVM) and arteriovenous fistula (AVF). However, this technique has the disadvantage of a relatively long scan time. The aim of this study was to compare diagnostic accuracy between compressed sensing (CS)-TOF and conventional parallel imaging (PI)-TOF-MRA for detecting and characterizing AVS. METHODS: This study was approved by the institutional review board for human studies. Participants comprised 56 patients who underwent both CS-TOF-MRA and PI-TOF-MRA on a 3-T MR unit with or without cerebral AVS between June 2016 and September 2018. Imaging parameters for both sequences were almost identical, except the acceleration factor of 3× for PI-TOF-MRA and 6.5× for CS-TOF-MRA, and the scan time of 5 min 19 s for PI-TOF-MRA and 2 min 26 s for CS-TOF-MRA. Two neuroradiologists assessed the accuracy of AVS detection on each sequence and analyzed AVS angioarchitecture. Concordance between CS-TOF, PI-TOF, and digital subtraction angiography was calculated using unweighted and weighted kappa statistics. RESULTS: Both CS-TOF-MRA and PI-TOF-MRA yielded excellent sensitivity and specificity for detecting intracranial AVS (reviewer 1, 97.3%, 94.7%; reviewer 2, 100%, 100%, respectively). Interrater agreement on the angioarchitectural features of intracranial AVS on CS-MRA and PI-MRA was moderate to good. CONCLUSION: The diagnostic performance of CS-TOF-MRA is comparable to that of PI-TOF-MRA in detecting and classifying AVS with a reduced scan time under 2.5 min.


Subject(s)
Arteriovenous Fistula , Magnetic Resonance Angiography , Angiography, Digital Subtraction , Humans , Prostheses and Implants , Sensitivity and Specificity
19.
Neurol Sci ; 42(2): 689-696, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32656715

ABSTRACT

BACKGROUND: Diffusion-weighted imaging (DWI) on magnetic resonance imaging (MRI) shows limited sensitivity in the acute-phase brainstem infarctions, including lateral medullary infarction (LMI), and the detailed characteristics of acute LMI patients with initially negative DWI-MRI findings have not been reported previously. Therefore, we aimed to investigate the differences in the backgrounds or symptoms of acute LMI patients with initially negative findings in standard axial DWI-MRI and those with positive findings. METHODS: In this retrospective cohort study, we collected the data for 35 consecutive acute LMI patients who were hospitalized in our hospital from January 2011 to December 2018. Initial standard axial DWI-MRI was assessed, and the patients were divided into positive and negative groups. The characteristics of the two groups were compared, and the usefulness of additional thin-slice coronal DWI-MRI was also investigated. RESULTS: Nine (26%) acute LMI patients were initially negative on standard axial DWI-MRI. The patients were independently associated with smoking history (78% vs. 23%, p = 0.021) and headache (78% vs. 31%, p = 0.046). Thin-slice coronal DWI-MRI showed positive findings in 50% of the patients with negative findings in standard axial DWI-MRI. All four patients with negative findings in both standard axial and thin-slice coronal DWI-MRI had smoking history and headache. CONCLUSION: Smoking history and headache were associated with initial negative results in standard axial DWI-MRI in acute LMI. Additional thin-slice coronal DWI-MRI was sometimes useful in detecting acute LMI. Follow-up MRI is important for patients showing negative findings in initial DWI-MRI.


Subject(s)
Brain Stem Infarctions , Diffusion Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging , Medulla Oblongata/diagnostic imaging , Retrospective Studies
20.
J Stroke Cerebrovasc Dis ; 29(6): 104798, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32249205

ABSTRACT

This is an extremely rare reported case of intravascular large B-cell lymphoma (IVLBCL) presenting with acute hemorrhages and numerous microbleeds. An 80-year-old man presented with consciousness disturbances after convulsion. Computed tomography revealed multiple hemorrhages, and susceptibility-weighted imaging (SWI) demonstrated numerous microbleeds. Brain biopsy showed CD20-positive cells in small vessels; accordingly, IVLBCL was diagnosed. IVLBCL should be considered as a differential diagnosis in multiple cerebral hemorrhages and microbleeds.


Subject(s)
Cerebral Hemorrhage/etiology , Hematoma/etiology , Lymphoma, B-Cell/complications , Vascular Neoplasms/complications , Aged, 80 and over , Antigens, CD20/analysis , Antineoplastic Combined Chemotherapy Protocols/administration & dosage , Biomarkers, Tumor/analysis , Biopsy , Cerebral Hemorrhage/diagnostic imaging , Cerebral Hemorrhage/pathology , Cyclophosphamide/administration & dosage , Diffusion Magnetic Resonance Imaging , Doxorubicin/administration & dosage , Hematoma/diagnostic imaging , Hematoma/pathology , Humans , Immunohistochemistry , Lymphoma, B-Cell/diagnostic imaging , Lymphoma, B-Cell/drug therapy , Lymphoma, B-Cell/pathology , Male , Prednisone/administration & dosage , Rituximab/administration & dosage , Tomography, X-Ray Computed , Treatment Outcome , Vascular Neoplasms/diagnostic imaging , Vascular Neoplasms/drug therapy , Vascular Neoplasms/pathology , Vincristine/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...