Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Harmful Algae ; 117: 102273, 2022 08.
Article in English | MEDLINE | ID: mdl-35944960

ABSTRACT

Machine learning, Deep learning, and water quality data have been used in recent years to predict the outbreak of harmful algae, especially Microcystis, and analyze outbreak causes. However, for various reasons, water quality data are often High-Dimension, Low-Sample- Size (HDLSS), meaning the sample size is lower than the number of dimensions. Moreover, imbalance problems may arise due to bias in the occurrence frequency of Microcystis. These problems make predicting the occurrence of Microcystis and analyzing its causes with machine learning difficult. In this study, a machine learning model that applies Feature Engineering (FE) and Feature Selection (FS) algorithms are used to predict outbreaks of Microcystis and analyze the outbreak factors from imbalanced HDLSS water quality data. The prediction performance was verified with binary classification to determine whether Microcystis would occur in the future by applying three machine learning models to four data patterns. The cause analysis of Microcystis occurrence was performed by visualizing the results of applying FE and FS. For the test data, the predictive performance of FE and FS methods was significantly better than that of the conventional method, with an accuracy of .108 points and an F-value of .691 points higher than the conventional method. A prediction performance increase was observed with a smaller model capacity. Data-driven analysis suggested that total nitrogen, chemical oxygen demand, chlorophyll-a, dissolved oxygen saturation, and water temperature are associated with Microcystis occurrences. The results also indicated that basic statistics of the water quality distribution (especially mean, standard deviation, and skewness) over a year, not the concentrations of water components, are related to the occurrence of Microcystis. These are new findings not found in previous studies and are expected to contribute significantly to future studies of algae. This study provides a method for analyzing water quality data with high-dimensionality and small samples, imbalance problems, or both.


Subject(s)
Microcystis , Chlorophyll A , Machine Learning , Sample Size , Water Quality
2.
Springerplus ; 2: 393, 2013.
Article in English | MEDLINE | ID: mdl-24010047

ABSTRACT

OBJECTIVES: This study aim to compare image quality and radiation doses between low-dose CT and follow-up standard diagnostic CT for lung cancer screening. METHODS: In a single medical institution, 19 subjects who had been screened for lung cancer by low-dose CT before going through follow-up standard diagnostic CT were randomly selected. Both CT image sets for all subjects were independently evaluated by five specialized physicians. RESULTS: There were no significant differences between low-dose CT screening and follow-up standard diagnostic CT for lung cancer screening in all 11 criteria. The concordance rate for the diagnoses was approximately 80% (p < 0.001) for all categories. Agreement of the evaluation of all categories in the final diagnosis exceeded 94% (p < 0.001). Five physicians detecting and characterizing the pulmonary nodules did not recognized the difference between low-dose CT screening and follow-up standard diagnostic CT. With low-dose CT, the effective dose ranged between 1.3 and 3.4 mSv, whereas in the follow-up diagnostic CT, the effective dose ranged between 8.5 and 14.0 mSv. CONCLUSION: This study suggests that low-dose CT can be effectively used as a follow-up standard diagnostic CT in place of standard-dose CT in order to reduce the radiation dose.

SELECTION OF CITATIONS
SEARCH DETAIL
...