Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 51
Filter
1.
Heart Rhythm O2 ; 5(2): 131-136, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38545321

ABSTRACT

Background: Respiratory motion management strategies are used to minimize the effects of breathing on the precision of stereotactic ablative radiotherapy for ventricular tachycardia, but the extent of cardiac contractile motion of the human heart has not been systematically explored. Objective: We aim to assess the magnitude of cardiac contractile motion between different directions and locations in the heart. Methods: Patients with intracardiac leads or valves who underwent 4-dimensional cardiac computed tomography (CT) prior to a catheter ablation procedure for atrial or ventricular arrhythmias at 2 medical centers were studied retrospectively. The displacement of transvenous right atrial appendage, right ventricular (RV) implantable cardioverter-defibrillator, coronary sinus lead tips, and prosthetic cardiac devices across the cardiac cycle were measured in orthogonal 3-dimensional views on a maximal-intensity projection CT reconstruction. Results: A total of 31 preablation cardiac 4-dimensional cardiac CT scans were analyzed. The LV lead tip had significantly greater motion compared with the RV lead in the anterior-posterior direction (6.0 ± 2.2 mm vs 3.8 ± 1.7 mm; P = .01) and superior-inferior direction (4.4 ± 2.9 mm vs 3.5 ± 2.0 mm; P = .049). The prosthetic aortic valves had the least movement of all fiducials, specifically compared with the RV lead tip in the left-right direction (3.2 ± 1.2 mm vs 6.1 ± 3.8 mm, P = .04) and the LV lead tip in the anterior-posterior direction (3.8 ± 1.7 mm vs 6.0 ± 2.2 mm, P = .03). Conclusion: The degree of cardiac contractile motion varies significantly (1 mm to 15.2 mm) across different locations in the heart. The effect of contractile motion on the precision of radiotherapy should be assessed on a patient-specific basis.

3.
J Cardiovasc Electrophysiol ; 35(5): 916-928, 2024 May.
Article in English | MEDLINE | ID: mdl-38439119

ABSTRACT

INTRODUCTION: Artificial intelligence (AI) ECG arrhythmia mapping provides arrhythmia source localization using 12-lead ECG data; whether this information impacts procedural efficiency is unknown. We performed a retrospective, case-control study to evaluate the hypothesis that AI ECG mapping may reduce time to ablation, procedural duration, and fluoroscopy. MATERIALS AND METHODS: Cases in which system output was used were retrospectively enrolled according to IRB-approved protocols at each site. Matched control cases were enrolled in reverse chronological order beginning on the last day for which the technology was unavailable. Controls were matched based upon physician, institution, arrhythmia, and a predetermined complexity rating. Procedural metrics, fluoroscopy data, and clinical outcomes were assessed from time-stamped medical records. RESULTS: The study group consisted of 28 patients (age 65 ± 11 years, 46% female, left atrial dimension 4.1 ± 0.9 cm, LVEF 50 ± 18%) and was similar to 28 controls. The most common arrhythmia types were atrial fibrillation (n = 10), premature ventricular complexes (n = 8), and ventricular tachycardia (n = 6). Use of the system was associated with a 19.0% reduction in time to ablation (133 ± 48 vs. 165 ± 49 min, p = 0.02), a 22.6% reduction in procedure duration (233 ± 51 vs. 301 ± 83 min, p < 0.001), and a 43.7% reduction in fluoroscopy (18.7 ± 13.3 vs. 33.2 ± 18.0 min, p < 0.001) versus controls. At 6 months follow-up, arrhythmia-free survival was 73.5% in the study group and 63.3% in the control group (p = 0.56). CONCLUSION: Use of forward-solution AI ECG mapping is associated with reductions in time to first ablation, procedure duration, and fluoroscopy without an adverse impact on procedure outcomes or complications.


Subject(s)
Action Potentials , Arrhythmias, Cardiac , Artificial Intelligence , Catheter Ablation , Predictive Value of Tests , Time-to-Treatment , Aged , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Electrocardiography , Electrophysiologic Techniques, Cardiac , Fluoroscopy , Heart Rate , Operative Time , Retrospective Studies , Time Factors , Treatment Outcome , Case-Control Studies
5.
AJR Am J Roentgenol ; 222(4): e2330357, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38323782

ABSTRACT

BACKGROUND. MRI-based prognostic evaluation in patients with dilated cardiomyopathy (DCM) has historically used markers of late gadolinium enhancement (LGE) and feature tracking (FT)-derived left ventricular global longitudinal strain (LVGLS). Early data indicate that FT-derived left atrial strain (LAS) parameters, including reservoir, conduit, and booster, may also have prognostic roles in such patients. OBJECTIVE. The purpose of our study was to evaluate the prognostic utility of LAS parameters, derived from MRI FT, in patients with ischemic or nonischemic DCM, including in comparison with the traditional parameters of LGE and LVGLS. METHODS. This retrospective study included 811 patients with ischemic or nonischemic DCM (median age, 60 years; 640 men, 171 women) who underwent cardiac MRI at any of five centers. FT-derived LAS parameters and LVGLS were measured using two- and four-chamber cine images. LGE percentage was quantified. Patients were assessed for a composite outcome of all-cause mortality or heart failure hospitalization. Multivariable Cox regression analyses including demographic characteristics, cardiovascular risk factors, medications used, and a wide range of cardiac MRI parameters were performed. Kaplan-Meier analyses with log-rank tests were also performed. RESULTS. A total of 419 patients experienced the composite outcome. Patients who did, versus those who did not, experience the composite outcome had larger LVGLS (-6.7% vs -8.3%, respectively; p < .001) as well as a smaller LAS reservoir (13.3% vs 19.3%, p < .001), LAS conduit (4.7% vs 8.0%, p < .001), and LAS booster (8.1% vs 10.3%, p < .001) but no significant difference in LGE (10.1% vs 11.3%, p = .51). In multivariable Cox regression analyses, significant independent predictors of the composite outcome included LAS reservoir (HR = 0.96, p < .001) and LAS conduit (HR = 0.91, p < .001). LAS booster and LGE were not significant independent predictors in the models. LVGLS was a significant independent predictor only in a model that initially included LAS booster but not the other LAS parameters. In Kaplan-Meier analysis, all three LAS parameters were significantly associated with the composite outcome (p < .001). CONCLUSION. In this multicenter study, LAS reservoir and LAS conduit were significant independent prognostic markers in patients with ischemic or nonischemic DCM, showing greater prognostic utility than the currently applied markers of LVGLS and LGE. CLINICAL IMPACT. FT-derived LAS analysis provides incremental prognostic information in patients with DCM.


Subject(s)
Cardiomyopathy, Dilated , Magnetic Resonance Imaging, Cine , Humans , Female , Male , Cardiomyopathy, Dilated/diagnostic imaging , Middle Aged , Prognosis , Retrospective Studies , Magnetic Resonance Imaging, Cine/methods , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Aged , Myocardial Ischemia/diagnostic imaging , Contrast Media , Magnetic Resonance Imaging/methods
6.
J Cardiovasc Comput Tomogr ; 18(2): 170-178, 2024.
Article in English | MEDLINE | ID: mdl-38242778

ABSTRACT

BACKGROUND: Lead placement at the latest mechanically activated left ventricle (LV) segments is strongly correlated with response to cardiac resynchronization therapy (CRT). We demonstrate the feasibility of a cardiac 4DCT motion correction algorithm (ResyncCT) in estimating LV mechanical activation for guiding lead placement in CRT. METHODS: Subjects with full cardiac cycle 4DCT images acquired using a wide-detector CT scanner for CRT planning/upgrade were included. 4DCT images exhibited motion artifact-induced false-dyssynchrony, hindering LV mechanical activation time estimation. Motion-corrupted images were processed with ResyncCT to yield motion-corrected images. Time to onset of shortening (TOS) was estimated in each of 72 endocardial segments. A false-dyssynchrony index (FDI) was used to quantify the extent of motion artifacts in the uncorrected and the ResyncCT images. After motion correction, the change in classification of LV free-wall segments as optimal target sites for lead placement was investigated. RESULTS: Twenty subjects (70.7 â€‹± â€‹13.9 years, 6 female) were analyzed. Motion artifacts in the ResyncCT-processed images were significantly reduced (FDI: 28.9 â€‹± â€‹9.3 â€‹% vs 47.0 â€‹± â€‹6.0 â€‹%, p â€‹< â€‹0.001). In 10 (50 â€‹%) subjects, ResyncCT motion correction yielded statistically different TOS estimates (p â€‹< â€‹0.05). Additionally, 43 â€‹% of LV free-wall segments were reclassified as optimal target sites for lead placement after motion correction. CONCLUSIONS: ResyncCT significantly reduced motion artifacts in wide-detector cardiac 4DCT images, yielded statistically different time to onset of shortening estimates, and changed the location of optimal target sites for lead placement. These results highlight the potential utility of ResyncCT motion correction in CRT planning when using wide-detector 4DCT imaging.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Female , Cardiac Resynchronization Therapy/methods , Heart Failure/therapy , Predictive Value of Tests , Heart , Heart Ventricles/diagnostic imaging , Treatment Outcome
7.
J Interv Card Electrophysiol ; 67(3): 639-648, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37855992

ABSTRACT

BACKGROUND: Pulsed field ablation (PFA) induces cell death through electroporation using ultrarapid electrical pulses. We sought to compare the procedural efficiency characteristics, safety, and efficacy of ablation of atrial fibrillation (AF) using PFA compared with thermal energy ablation. METHODS: We performed an extensive literature search and systematic review of studies that compared ablation of AF with PFA versus thermal energy sources. Risk ratio (RR) 95% confidence intervals (CI) were measured for dichotomous variables and mean difference (MD) 95% CI were measured for continuous variables, where RR < 1 and MD < 0 favor the PFA group. RESULTS: We included 6 comparative studies for a total of 1012 patients who underwent ablation of AF: 43.6% with PFA (n = 441) and 56.4% (n = 571) with thermal energy sources. There were significantly shorter procedures times with PFA despite a protocolized 20-min dwell time (MD - 21.95, 95% CI - 33.77, - 10.14, p = 0.0003), but with significantly longer fluroscopy time (MD 5.71, 95% CI 1.13, 10.30, p = 0.01). There were no statistically significant differences in periprocedural complications (RR 1.20, 95% CI 0.59-2.44) or recurrence of atrial tachyarrhythmias (RR 0.64, 95% CI 0.31, 1.34) between the PFA and thermal ablation cohorts. CONCLUSIONS: Based on the results of this meta-analysis, PFA was associated with shorter procedural times and longer fluoroscopy times, but no difference in periprocedural complications or rates of recurrent AF when compared to ablation with thermal energy sources. However, larger randomized control trials are needed.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria/surgery , Treatment Outcome , Pulmonary Veins/surgery
8.
Heart Rhythm O2 ; 4(10): 599-608, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37936671

ABSTRACT

Background: Pulsed field ablation (PFA) has emerged as a novel energy source for the ablation of atrial fibrillation (AF) using ultrarapid electrical pulses to induce cell death via electroporation. Objective: The purpose of this study was to compare the safety and acute efficacy of ablation for AF with PFA vs thermal energy sources. Methods: We performed an extensive literature search and systematic review of studies that evaluated the safety and efficacy of ablation for AF with PFA and compared them to landmark clinical trials for ablation of AF with thermal energy sources. Freeman-Tukey double arcsine transformation was used to establish variance of raw proportions followed by the inverse with the random-effects model to combine the transformed proportions and generate the pooled prevalence and 95% confidence interval (CI). Results: We included 24 studies for a total of 5203 patients who underwent AF ablation. Among these patients, 54.6% (n = 2842) underwent PFA and 45.4% (n = 2361) underwent thermal ablation. There were significantly fewer periprocedural complications in the PFA group (2.05%; 95% CI 0.94-3.46) compared to the thermal ablation group (7.75%; 95% CI 5.40-10.47) (P = .001). When comparing AF recurrence up to 1 year, there was a statistically insignificant trend toward a lower prevalence of recurrence in the PFA group (14.24%; 95% CI 6.97-23.35) compared to the thermal ablation group (25.98%; 95% CI 15.75-37.68) (P = .132). Conclusion: Based on the results of this meta-analysis, PFA was associated with lower rates of periprocedural complications and similar rates of acute procedural success and recurrent AF with up to 1 year of follow-up compared to ablation with thermal energy sources.

9.
Front Cardiovasc Med ; 10: 1267800, 2023.
Article in English | MEDLINE | ID: mdl-37799779

ABSTRACT

Background: Stereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR. Methods: Delineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient. Results: Ten electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02-0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52-1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51-1.55 cm, Dice-coefficient mean: 0.31 ± 0.21). Conclusions: Interobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation.

10.
Clin Cardiol ; 46(12): 1488-1494, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37626475

ABSTRACT

BACKGROUND: Catheter ablation improves outcomes in symptomatic atrial fibrillation (AF) patients. However, its safety and efficacy in the very elderly (≥80 years old) is not well described. HYPOTHESIS: Ablation of AF in the very elderly is safe and effective. METHODS: We performed a retrospective study of all patients who underwent catheter ablation enrolled in the University of California, San Diego AF Ablation Registry. The primary outcome was freedom from atrial arrhythmias on or off antiarrhythmic drugs (AADs). RESULTS: Of 847 patients, 42 (5.0%) were 80 years of age or greater with a median age of 81.5 (80-82.3) and 805 (95.0%) were less than 80 years of age with a median age of 64.4 (57.6-70.2). Among those who were ≥80 years old, 29 were undergoing de novo ablation (69.0%), whereas in the younger cohort, 518 (64.5%) were undergoing de novo ablation (p = .548). There were no statistically significant differences in fluoroscopy (p = .406) or total procedure times (p = .076), AAD use (p = .611), or procedural complications (p = .500) between groups. After multivariable adjustment, there were no statistically significant differences in recurrence of any atrial arrhythmias on or off AAD (adjusted hazard ratio [AHR]: 0.75; 95% confidence interval [CI]: 0.45-1.23; p = .252), all-cause hospitalizations (AHR: 0.86; 95% CI: 0.46-1.60; p = .626), or all-cause mortality (AHR: 4.48; 95% CI: 0.59-34.07; p = .147) between the very elderly and the younger cohort. CONCLUSION: In this registry analysis, catheter ablation of AF appears similarly effective and safe in patients 80 years or older when compared to a younger cohort.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Aged , Aged, 80 and over , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Retrospective Studies , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Registries , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
11.
JACC Case Rep ; 15: 101870, 2023 Jun 07.
Article in English | MEDLINE | ID: mdl-37283824

ABSTRACT

In patients presenting with refractory ventricular tachycardia (VT) and aortic and mitral mechanical prosthetic valves, traditional catheter ablation is challenging. We describe a case in which a novel noninvasive computational electrocardiogram mapping algorithm localized VT sources originating from substrate near the mechanical valves, in which stereotactic ablative radiotherapy eliminated VT in 1.5-year follow-up. (Level of Difficulty: Advanced.).

12.
J Interv Card Electrophysiol ; 66(5): 1243-1252, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36508065

ABSTRACT

BACKGROUND: High-dose isoproterenol infusion is a useful provocative maneuver to elicit triggers of atrial fibrillation (AF) during ablation. We evaluated whether the use of isoproterenol infusion to elicit triggers of AF after ablation is associated with differential outcomes. METHODS: We performed a retrospective study of all patients who underwent de novo radiofrequency catheter ablation of AF enrolled in the University of California, San Diego AF Ablation Registry. The primary outcome was freedom from atrial arrhythmias on or off antiarrhythmic drugs (AAD). RESULTS: Of 314 patients undergoing AF ablation, 235 (74.8%) received isoproterenol while 79 (25.2%) did not. Among those who received isoproterenol, 11 (4.7%) had additional triggers identified. There were no statistically significant differences in procedure time (p = 0.432), antiarrhythmic drug use (p = 0.289), procedural complications (p = 0.279), recurrences of atrial arrhythmias on or off AAD [adjusted hazard ratio (AHR) 0.92 (95% CI 0.58-1.46); p = 0.714], all-cause hospitalizations [AHR 1.00 (95% CI 0.60-1.67); p = 0.986], or all-cause mortality [AHR 0.14 (95% CI 0.01-3.52); p = 0.229] between groups. CONCLUSIONS: In this registry analysis, use of isoproterenol is safe but was not associated with a reduction in recurrence of atrial arrhythmias.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Isoproterenol , Treatment Outcome , Retrospective Studies , Anti-Arrhythmia Agents/therapeutic use , Registries , Catheter Ablation/methods , Recurrence
15.
Circ Arrhythm Electrophysiol ; 15(9): e010857, 2022 09.
Article in English | MEDLINE | ID: mdl-36069189

ABSTRACT

BACKGROUND: The accuracy of noninvasive arrhythmia source localization using a forward-solution computational mapping system has not yet been evaluated in blinded, multicenter analysis. This study tested the hypothesis that a computational mapping system incorporating a comprehensive arrhythmia simulation library would provide accurate localization of the site-of-origin for atrial and ventricular arrhythmias and pacing using 12-lead ECG data when compared with the gold standard of invasive electrophysiology study and ablation. METHODS: The VMAP study (Vectorcardiographic Mapping of Arrhythmogenic Probability) was a blinded, multicenter evaluation with final data analysis performed by an independent core laboratory. Eligible episodes included atrial and ventricular: tachycardia, fibrillation, pacing, premature atrial and ventricular complexes, and orthodromic atrioventricular reentrant tachycardia. Mapping system results were compared with the gold standard site of successful ablation or pacing during electrophysiology study and ablation. Mapping time was assessed from time-stamped logs. Prespecified performance goals were used for statistical comparisons. RESULTS: A total of 255 episodes from 225 patients were enrolled from 4 centers. Regional accuracy for ventricular tachycardia and premature ventricular complexes in patients without significant structural heart disease (n=75, primary end point) was 98.7% (95% CI, 96.0%-100%; P<0.001 to reject predefined H0 <0.80). Regional accuracy for all episodes (secondary end point 1) was 96.9% (95% CI, 94.7%-99.0%; P<0.001 to reject predefined H0 <0.75). Accuracy for the exact or neighboring segment for all episodes (secondary end point 2) was 97.3% (95% CI, 95.2%-99.3%; P<0.001 to reject predefined H0 <0.70). Median spatial accuracy was 15 mm (n=255, interquartile range, 7-25 mm). The mapping process was completed in a median of 0.8 minutes (interquartile range, 0.4-1.4 minutes). CONCLUSIONS: Computational ECG mapping using a forward-solution approach exceeded prespecified accuracy goals for arrhythmia and pacing localization. Spatial accuracy analysis demonstrated clinically actionable results. This rapid, noninvasive mapping technology may facilitate catheter-based and noninvasive targeted arrhythmia therapies. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04559061.


Subject(s)
Catheter Ablation , Tachycardia, Supraventricular , Tachycardia, Ventricular , Ventricular Premature Complexes , Catheter Ablation/methods , Electrocardiography/methods , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery
16.
Pacing Clin Electrophysiol ; 45(7): 853-860, 2022 07.
Article in English | MEDLINE | ID: mdl-35587876

ABSTRACT

BACKGROUND: Limited data exists for outcomes in patients undergoing cardiovascular implantable electronic device (CIED) transvenous lead extraction (TLE) without clear indications for device reimplantation. The implantable loop recorder (ILR) may be an effective strategy for continuous monitoring in select individuals. OBJECTIVE: This retrospective analysis aims to investigate patients who have undergone ILR implant following TLE without CIED reimplantation. METHODS: Clinical data from consecutive patients who have undergone TLE with ILR implant and without CIED reimplantation from October 2016 to May 2020 at a single center were collected. RESULTS: Among 380 patients undergoing TLE, 28 (7.7%) underwent ILR placement without CIED reimplantation. TLE indications were systemic infection (n = 13, 46.4%), pain at the site (n = 8, 28.6%), device/lead malfunction (n = 4, 14.2%), and other. Devices extracted included: dual-chamber and single-chamber pacemaker (n = 14, 50%; n = 4, 14.2%), dual-chamber implantable cardiac defibrillator (n = 10; 35.7%), and cardiac-resynchronization therapy with defibrillator (n = 1, 3.5%). Reasons for no reimplantation included no longer meeting CIED criteria (n = 14, 50%), patient preference (n = 9, 32.1%), and no clear or inappropriate indication for initial CIED implantation (n = 5, 18%). During an average of 12.3 ± 13.1 months of follow-up, there were no lethal arrhythmias, and four (13.3%) patients underwent permanent pacemaker reimplantation due to symptomatic sinus bradycardia and atrioventricular block with syncope as discovered on ILR. Three patients died due to unknown causes (n = 1), noncardiac (n = 1), and acute coronary syndrome (n = 1). CONCLUSIONS: In patients undergoing TLE without reimplantation, an ILR may be an effective monitoring strategy in patients at low risk for cardiac arrhythmia.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/adverse effects , Electronics , Humans , Pacemaker, Artificial/adverse effects , Retrospective Studies
17.
J Interv Card Electrophysiol ; 64(3): 715-722, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35169965

ABSTRACT

BACKGROUND: The mechanisms for atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) catheter ablation are unclear. Non-PV organized atrial arrhythmias (PAC, AT, macro-reentrant AFL) are possible contributors; however the prevalence and effect of their ablation on recurrent AF are unknown. We hypothesize that the identification and ablation of non-PV organized atrial arrhythmias were associated with less AF recurrence. METHODS: Patients who underwent repeat ablation for recurrent AF after prior PVI were retrospectively enrolled. The prevalence and characteristics of PV reconnections and non-PV organized atrial arrhythmias were identified. The outcomes of time to clinical AF recurrence, heart failure (HF) hospitalization, and mortality were analyzed in patients using multivariable adjusted Cox regression. RESULTS: In 74 patients with recurrent AF (age 66 ± 9 years, left atrial volume index 38 ± 10 ml/m2, 59% persistent AF), PV reconnections were found in 46 patients (61%), macro-reentrant atrial flutter in 27 patients (36%), and focal tachycardia in 12 patients (16%). Mapping and ablation of non-PV organized atrial arrhythmias were associated with a reduced recurrence of late clinical AF (adjusted HR 0.26, CI 0.08-0.85, p = 0.03) and the composite outcome of recurrence of late AF, HF hospitalization, and mortality (adjusted HR 0.38, CI 0.17-0.85, p = 0.02), with median follow-up of 1.6 (IQR 0.7-6.3) years. The presence of PV reconnections or empiric linear ablation was not associated with reduction in clinical AF or composite endpoints. CONCLUSION: The ablation of non-PV organized atrial arrhythmias resulted in a reduction of late clinical AF recurrence and composite outcome. In this challenging population, alternate mechanisms beyond PV reconnections need to be considered. Prospective studies are needed.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Atrial Fibrillation/epidemiology , Catheter Ablation/methods , Humans , Middle Aged , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
18.
J Interv Card Electrophysiol ; 64(2): 323-331, 2022 Aug.
Article in English | MEDLINE | ID: mdl-33826085

ABSTRACT

PURPOSE: Early recurrence of atrial tachyarrhythmia (ER) is predictive of late recurrence of atrial tachyarrhythmia (LR) after first-time atrial fibrillation (AF) ablation, but the association in patients undergoing repeat AF ablation is unknown. We aim to determine the incidence and prognostic significance of ER after repeat ablation. METHODS: A total of 259 consecutive patients (mean age 64 years, 75.3% male) undergoing repeat AF ablation with complete follow-up data were included at a single institution from 2010 to 2015. ER and LR were defined as atrial tachyarrhythmia (AF, atrial flutter or atrial tachycardia) > 30 s within the 3-month blanking period (BP) and after the 3-month BP, respectively. RESULTS: ER occurred in 79/259 (30.5%), and LR occurred in 138/259 (53%) at a median follow-up of 1221 (IQR: 523-1712) days. Four-year freedom from LR was 22% and 56% in patients with and without ER, respectively (p < 0.001). After multivariate adjustment, ER was strongly associated with LR, cardioversion post BP, and repeat ablation, but not associated with hospitalization. Compared to those with no ER, there was a higher risk of LR when ER occurred within the first month of the BP [month 1: hazard ratio (HR) 2.32, confidence interval (CI) 1.57-3.74, p < 0.001; month 2: HR 2.01, CI 1.13-3.83, p = 0.02; month 3: HR 1.46, CI 0.5-3.36, p = 0.37], however the prediction of LR based on timing within the BP was poor (area under curve 0.64). CONCLUSION: Following repeat AF ablation, ER is strongly associated with LR, cardioversion post BP, and repeat ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/epidemiology , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Recurrence , Tachycardia/surgery , Treatment Outcome
19.
J Interv Card Electrophysiol ; 63(1): 87-95, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33538952

ABSTRACT

PURPOSE: Mitral annular flutter (MAF) is a common arrhythmia after atrial fibrillation ablation. We sought to compare the efficacy and safety of catheter ablation utilizing either a left atrial anterior wall (LAAW) line or a lateral mitral isthmus (LMI) line. METHODS: We performed a systematic review for all studies that compared LAAW versus LMI lines. Risk ratio (RR) and mean difference (MD) 95% confidence intervals were measured for dichotomous and continuous variables, respectively. RESULTS: Four studies with a total of 594 patients were included, one of which was a randomized control trial. In the LMI ablation group, 40% of patients required CS ablation. There were no significant differences in bidirectional block (RR 1.26; 95% CI, 0.94-1.69) or ablation time (MD -1.5; 95% CI, -6.11-3.11), but LAAW ablation was associated with longer ablation line length (MD 11.42; 95% CI, 10.69-12.14) and longer LAA activation delay (MD 67.68; 95% CI, 33.47-101.89.14) when compared to LMI. There was no significant difference in pericardial effusions (RR 0.36; 95% CI, 0.39-20.75) between groups and more patients were maintained sinus rhythm (RR 1.19; 95% CI, 1.03-1.37, p = 0.02) who underwent LAAW compared to LMI. CONCLUSION: Ablation of mitral annular flutter with a LAAW line compared to a LMI line showed no difference in rates of acute bidirectional block, ablation time, or pericardial effusion. However, LAAW ablation required a longer ablation line length, resulted in greater LAA activation delayed and was associated with more sinus rhythm maintenance, with the added advantage of avoiding ablation in the CS.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Flutter/diagnostic imaging , Atrial Flutter/surgery , Heart Atria/surgery , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Randomized Controlled Trials as Topic , Treatment Outcome
20.
Heart Rhythm O2 ; 2(5): 511-520, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34667967

ABSTRACT

BACKGROUND: Stereotactic ablative radiotherapy (SAbR) is an emerging therapy for refractory ventricular tachycardia (VT). However, the current workflow is complicated, and the precision and safety in patients with significant cardiorespiratory motion and VT targets near the stomach may be suboptimal. OBJECTIVE: We hypothesized that automated 12-lead electrocardiogram (ECG) mapping and respiratory-gated therapy may improve the ease and precision of SAbR planning and facilitate safe radiation delivery in patients with refractory VT. METHODS: Consecutive patients with refractory VT were studied at 2 hospitals. VT exit sites were localized using a 3-D computational ECG algorithm noninvasively and compared to available prior invasive mapping. Radiotherapy (25 Gy) was delivered at end-expiration when cardiac respiratory motion was ≥0.6 cm or targets were ≤2 cm from the stomach. RESULTS: In 6 patients (ejection fraction 29% ± 13%), 4.2 ± 2.3 VT morphologies per patient were mapped. Overall, 7 out of 7 computational ECG mappings (100%) colocalized to the identical cardiac segment when prior invasive electrophysiology study was available. Respiratory gating was associated with smaller planning target volumes compared to nongated volumes (71 ± 7 vs 153 ± 35 cc, P < .01). In 2 patients with inferior wall VT targets close to the stomach (6 mm proximity) or significant respiratory motion (22 mm excursion), no GI complications were observed at 9- and 12-month follow-up. Implantable cardioverter-defibrillator shocks decreased from 23 ± 12 shocks/patient to 0.67 ± 1.0 (P < .001) post-SAbR at 6.0 ± 4.9 months follow-up. CONCLUSIONS: A workflow including computational ECG mapping and protocol-guided respiratory gating is feasible, is safe, and may improve the ease of SAbR planning. Studies to validate this workflow in larger populations are required.

SELECTION OF CITATIONS
SEARCH DETAIL
...