Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Endourol ; 38(3): 253-261, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38185840

ABSTRACT

Background: Several centers have reported their experience with single-port robot-assisted partial nephrectomy (SP-RAPN); however, it is uncertain if utilization of this platform represents an improvement in outcomes compared to multiport robot-assisted partial nephrectomy (MP-RAPN). To evaluate this, we performed a meta-analysis to compare the perioperative, oncological, and functional outcomes between SP-RAPN and MP-RAPN. Methods: For relevant articles, three electronic databases, including PubMed, Scopus, and Web of Science, were searched from their inception until January 1, 2023. A meta-analysis has been reported in line with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 and assessing the methodological quality of systematic reviews (AMSTAR) guidelines. The odds ratio (OR) and weighted mean difference (MD) were applied for the comparison of dichotomous and continuous variables with 95% confidence intervals (CI). Results: Of the 374 retrieved abstracts, 29 underwent full-text review, and 8 studies were included in the final analysis, comprising a total cohort of 1007 cases of RAPN (453 SP-RAPN cases and 554 MP-RAPN cases). Compared to MP-RAPN, the SP-RAPN group had a significantly longer ischemia time (MD = 4.6 minutes, 95% CI 2.8 to 6.3, p < 0.001), less estimated blood loss (MD = -12.4 mL, 95% CI -24.6 to -0.3, p = 0.045), higher blood transfusion rate (OR = 2.97, 95% CI 1.33 to 6.65, p = 0.008), and higher postoperative estimated glomerular filtration rate (eGFR) at 6 months (MD = 4.9 mL/min, 95% CI 0.2 to 9.7, p = 0.04). There was no significant difference in other outcomes between the two approaches, including the intraoperative complication, overall postoperative complication, minor postoperative complication (Clavien-Dindo I - II), major postoperative complication (Clavien-Dindo III-V), conversion to radical nephrectomy, pain score on day #1, pain score on discharge, morphine milligram equivalent usage, hospital stay, positive surgical margins, and postoperative eGFR. Conclusions: SP-RAPN represents an emerging technique using a novel platform. Initial studies have demonstrated that SP-RAPN is a safe and feasible approach to performing partial nephrectomy, although with inferior outcomes for ischemia time and blood transfusion rates. Further studies will be necessary to define the best usage of SP-RAPN within the surgeon's armamentarium.


Subject(s)
Kidney Neoplasms , Robotic Surgical Procedures , Robotics , Humans , Kidney Neoplasms/surgery , Treatment Outcome , Nephrectomy/methods , Blood Transfusion , Robotic Surgical Procedures/methods , Postoperative Complications/etiology , Ischemia , Pain , Retrospective Studies
2.
Osteoporos Sarcopenia ; 9(3): 79-87, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37941533

ABSTRACT

Objectives: Osteoporotic fracture is a significant public health burden associated with increased mortality risk and substantial healthcare costs. Accurate and early identification of high-risk individuals and mitigation of their risks is a core part of the treatment and prevention of fractures. Here we introduce a digital tool called 'BONEcheck' for personalized assessment of bone health. Methods: The development of BONEcheck primarily utilized data from the prospective population-based Dubbo Osteoporosis Epidemiology Study and the Danish Nationwide Registry. BONEcheck has 3 modules: input data, risk estimates, and risk context. Input variables include age, gender, prior fracture, fall incidence, bone mineral density (BMD), comorbidities, and genetic variants associated with BMD. Results: Based on the input variables, BONEcheck estimates the probability of any fragility fracture and hip fracture within 5 years, subsequent fracture risk, skeletal age, and time to reach osteoporosis. The probability of fracture is shown in both numeric and human icon array formats. The risk is also contextualized within the framework of treatment and management options on Australian guidelines, with consideration given to the potential fracture risk reduction and survival benefits. Skeletal age was estimated as the sum of chronological age and years of life lost due to a fracture or exposure to risk factors that elevate mortality risk. Conclusions: BONEcheck is an innovative tool that empowers doctors and patients to engage in well-informed discussions and make decisions based on the patient's risk profile. Public access to BONEcheck is available via https://bonecheck.org and in Apple Store (iOS) and Google Play (Android).

3.
J Healthc Eng ; 2022: 7716821, 2022.
Article in English | MEDLINE | ID: mdl-36275397

ABSTRACT

This study aims to investigate the gait stability response during incline and decline walking for various surface inclination angles in terms of the required coefficient of friction (RCOF), postural stability index (PSI), and center of pressure (COP)-center of mass (COM) distance. A customized platform with different surface inclinations (0°, 5°, 7.5°, and 10°) was designed. Twenty-three male volunteers participated by walking on an inclined platform for each inclination. The process was then repeated for declined platform as well. Qualysis motion capture system was used to capture and collect the trajectories motion of ten reflective markers that attached to the subjects before being exported to a visual three-dimensional (3D) software and executed in Matlab to obtain the RCOF, PSI, as well as dynamic PSI (DPSI) and COP-COM distance parameters. According to the result for incline walking, during initial contact, the RCOF was not affected to inclination. However, it was affected during peak ground reaction force (GRF) starting at 7.5° towards 10° for both walking conditions. The most affected PSI was found at anterior-posterior PSI (APSI) even as low as 5° inclination during both incline and decline walking. On the other hand, DPSI was not affected during both walking conditions. Furthermore, COP-COM distance was most affected during decline walking in anterior-posterior direction. The findings of this research indicate that in order to decrease the risk of falling and manage the inclination demand, a suitable walking strategy and improved safety measures should be applied during slope walking, particularly for decline and anterior-posterior orientations. This study also provides additional understanding on the best incline walking technique for secure and practical incline locomotion.


Subject(s)
Gait , Postural Balance , Male , Humans , Friction , Postural Balance/physiology , Gait/physiology , Walking/physiology , Accidental Falls/prevention & control , Biomechanical Phenomena
4.
World J Surg ; 46(10): 2377-2388, 2022 10.
Article in English | MEDLINE | ID: mdl-35802159

ABSTRACT

BACKGROUND: Emphysematous pyelonephritis (EP) is a severe necrotizing infection of the renal parenchyma which is associated with significant case mortality. We sought to identify the incidence and predictive risk factors associated with EP mortality. METHODS: Two electronic databases, PubMed and Web of Science, were searched from their inception until June 06, 2021 for relevant articles. Two independent teams reviewed abstracts and extracted data from the selected manuscripts. A meta-analysis has been reported in line with PRISMA 2020 and AMSTAR Guidelines. RESULTS: Of the 1080 retrieved abstracts, 79 underwent full-text review and 45 studies were included in the final analysis, comprising a total cohort of 1303 patients and 177 mortalities. The pooled prevalence of mortality among the patients with EP disease was 13%. Our analysis found a significantly decreasing trend in mortality rates, an increasing trend in minimally invasive intervention and decreasing trends in emergency nephrectomy in the EP studies from 1985 to 2020. Significant risk factors that were associated with a negative impact on survival of EP patients included sepsis (OR = 15.99), shock (OR = 15.57), disturbance of consciousness (OR = 12.11), thrombocytopenia (OR 7.85), acute renal failure (OR = 5.41), Wan classification I (OR = 4.57), emergency nephrectomy (OR = 3.73), Huang-Tseng classification III-IV (OR = 2.4) and medical management alone (OR = 2.04). Female sex (OR = 0.52) and minimally invasive intervention (OR = 0.47) (percutaneous nephrostomy or ureteral stent placement) were associated with decreased mortality rates. CONCLUSIONS: Our study results demonstrated several significant risk factors that could help guide treatment to reduce the mortality risk of EP patients. Clinically, early treatment with a combination of minimally invasive intervention and appropriate medical management may be protective for reducing mortality risk in EP patients.


Subject(s)
Emphysema , Pyelonephritis , Emphysema/complications , Emphysema/epidemiology , Female , Humans , Nephrectomy , Prevalence , Pyelonephritis/complications , Pyelonephritis/epidemiology , Risk Factors
5.
J Med Case Rep ; 16(1): 158, 2022 Apr 19.
Article in English | MEDLINE | ID: mdl-35440026

ABSTRACT

BACKGROUND: Penile strangulation is an uncommon urological emergency that requires prompt intervention to avoid potentially serious sequelae including loss of the distal penis secondary to ischemia and subsequent gangrene. We present a case report of a patient who presented to the hospital with penile strangulation injury of 10-hour duration secondary to the presence of a thick hexagonal steel nut. This case is presented in accordance with Consensus Surgical Case Report guidelines. CASE PRESENTATION: A 24-year-old Vietnamese man presented to the emergency room with urinary retention and decreased penile sensation following a 10-hour history of penile strangulation due to the presence of a thick hexagonal steel nut that he had placed around the shaft of the penis for the purpose of sexual enhancement during masturbation. The hexagonal nut was tightly entrapping the penile shaft, resulting in edema, congestion, and swelling of the distal 5 cm of the phallus. Given the thickness of the foreign body as well as the degree of penile swelling, we were unable to remove the hexagonal nut using traditional methods of alleviating penile strangulation injuries. Following consultation with a dental colleague, a dental diamond drill handpiece was utilized to cut the foreign body without injury to the underlying penile skin. Subsequent follow-up in clinic demonstrated no significant urinary or sexual sequalae from this episode. CONCLUSION: We report a case of penile strangulation requiring novel instrumentation and collaboration for successful treatment.


Subject(s)
Foreign Bodies , Penile Diseases , Adult , Foreign Bodies/complications , Foreign Bodies/surgery , Humans , Male , Nuts , Penile Diseases/surgery , Penis/surgery , Steel , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...