Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
EJNMMI Radiopharm Chem ; 9(1): 2, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38165504

ABSTRACT

BACKGROUND: Nuclear medicine has made enormous progress in the past decades. However, there are still significant inequalities in patient access among different countries, which could be mitigated by improving access to and availability of radiopharmaceuticals. MAIN BODY: This paper summarises major considerations for a suitable pharmaceutical regulatory framework to facilitate patient access to radiopharmaceuticals. These include the distinct characteristics of radiopharmaceuticals which require dedicated regulations, considering the impact of the variable complexity of radiopharmaceutical preparation, personnel requirements, manufacturing practices and quality assurance, regulatory authority interfaces, communication and training, as well as marketing authorisation procedures to ensure availability of radiopharmaceuticals. Finally, domestic and regional supply to ensure patient access via alternative regulatory pathways, including in-house production of radiopharmaceuticals, is described, and an outlook on regulatory challenges faced by new developments, such as the use of alpha emitters, is provided. CONCLUSIONS: All these considerations are an outcome of a dedicated Technical Meeting organised by the IAEA in 2023 and represent the views and opinions of experts in the field, not those of any regulatory authorities.

2.
Front Chem ; 10: 878835, 2022.
Article in English | MEDLINE | ID: mdl-35433631

ABSTRACT

Mitochondrial complex I (MC-I) is an essential component of brain bioenergetics and can be quantified and studied using positron emission tomography (PET). A specific high affinity 18F radiotracer for MC-I enables monitoring of neurodegenerative disease progression and pathology via PET imaging. To facilitate clinical research studies tracking MC-I activity in Parkinson's disease and other neurodegenerative diseases, a fully automated synthesis of the recently described 2-tert-butyl-4-chloro-5-{6-[2-(2[18F]fluoroethoxy)-ethoxy]-pyridin-3-ylmethoxy}-2H-pyridazin-3-one ([18F] BCPP-EF, [ 18 F]1) was developed. We report the first automated synthesis [18F]BCPP-EF using a green radiochemistry approach. The radiotracer was synthesized with good radiochemical yield, excellent radiochemical purity, and high molar activity.

3.
Nat Protoc ; 17(4): 980-1003, 2022 04.
Article in English | MEDLINE | ID: mdl-35246649

ABSTRACT

[68Ga]Ga-PSMA-11, a urea-based peptidomimetic, is a diagnostic radiopharmaceutical for positron emission tomography (PET) imaging that targets the prostate-specific membrane antigen (PSMA). The recent Food and Drug Administration approval of [68Ga]Ga-PSMA-11 for PET imaging of patients with prostate cancer, expected follow-up approval of companion radiotherapeutics (e.g., [177Lu]Lu-PSMA-617, [225Ac]Ac-PSMA-617) and large prostate cancer patient volumes requiring access are poised to create an unprecedented demand for [68Ga]Ga-PSMA-11 in nuclear medicine clinics around the world. Meeting this global demand is going to require a variety of synthesis methods compatible with 68Ga eluted from a generator or produced on a cyclotron. To address this urgent need in the PET radiochemistry community, herein we report detailed protocols for the synthesis of [68Ga]Ga-PSMA-11, (also known as HBED-CC, Glu-urea-Lys(Ahx)-HBED-CC and PSMA-HBED-CC) using both generator-eluted and cyclotron-produced 68Ga and contrast the pros and cons of each method. The radiosyntheses are automated and have been validated for human use at two sites (University of Michigan (UM), United States; Royal Prince Alfred Hospital (RPA), Australia) and used to produce [68Ga]Ga-PSMA-11 for patient use in good activity yields (single generator, 0.52 GBq (14 mCi); dual generators, 1.04-1.57 GBq (28-42 mCi); cyclotron method (single target), 1.47-1.89 GBq (40-51 mCi); cyclotron method (dual target), 3.63 GBq (98 mCi)) and high radiochemical purity (99%) (UM, n = 645; RPA, n > 600). Both methods are appropriate for clinical production but, in the long term, the method employing cyclotron-produced 68Ga is the most promising for meeting high patient volumes. Quality control testing (visual inspection, pH, radiochemical purity and identity, radionuclidic purity and identity, sterile filter integrity, bacterial endotoxin content, sterility, stability) confirmed doses are suitable for clinical use, and there is no difference in clinical prostate cancer PET imaging using [68Ga]Ga-PSMA-11 prepared using the two production methods.


Subject(s)
Prostatic Neoplasms , Radiopharmaceuticals , Cyclotrons , Edetic Acid , Gallium Radioisotopes/chemistry , Humans , Male , Positron-Emission Tomography/methods , Prostatic Neoplasms/diagnostic imaging , Urea
4.
J Labelled Comp Radiopharm ; 64(4): 187-193, 2021 04.
Article in English | MEDLINE | ID: mdl-33274468

ABSTRACT

A new method for the synthesis of the highly selective delta opioid receptor (DOR) antagonist radiotracer N1 '-([11 C]methyl)naltrindole ([11 C]MeNTI) is described. The original synthesis required hydrogenation of a benzyl protecting group after 11 C-labeling, which is challenging in modern radiochemistry laboratories that tend to be heavily automated and operate according to current good manufacturing practice. To address this challenge, we describe development of a novel MeNTI precursor bearing a methoxymethyl acetal (MOM) protecting group, which is easily removed with HCl, and employ it in an updated synthesis of [11 C]MeNTI. The new synthesis is fully automated and validated for clinical use. The total synthesis time is 45 min and provides [11 C]MeNTI in good activity yield (49 ± 8 mCi), molar activity (3,926 ± 326 Ci/mmol) and radiochemical purity (97% ± 2%).


Subject(s)
Indoles/chemistry , Morphinans/chemistry , Positron-Emission Tomography/methods , Radiopharmaceuticals/chemical synthesis , Receptors, Opioid, delta/metabolism , Carbon Radioisotopes/chemistry
5.
EJNMMI Radiopharm Chem ; 5(1): 25, 2020 Nov 12.
Article in English | MEDLINE | ID: mdl-33180205

ABSTRACT

PURPOSE: To optimize the direct production of 68Ga on a cyclotron, via the 68Zn(p,n)68Ga reaction using a liquid cyclotron target. We Investigated the yield of cyclotron-produced 68Ga, extraction of [68Ga]GaCl3 and subsequent [68Ga]Ga-PSMA-11 labeling using an automated synthesis module. METHODS: Irradiations of a 1.0 M solution of [68Zn]Zn(NO3)2 in dilute (0.2-0.3 M) HNO3 were conducted using GE PETtrace cyclotrons and GE 68Ga liquid targets. The proton beam energy was degraded to a nominal 14.3 MeV to minimize the co-production of 67Ga through the 68Zn(p,2n)67Ga reaction without unduly compromising 68Ga yields. We also evaluated the effects of varying beam times (50-75 min) and beam currents (27-40 µA). Crude 68Ga production was measured. The extraction of [68Ga]GaCl3 was performed using a 2 column solid phase method on the GE FASTlab Developer platform. Extracted [68Ga]GaCl3 was used to label [68Ga]Ga-PSMA-11 that was intended for clinical use. RESULTS: The decay corrected yield of 68Ga at EOB was typically > 3.7 GBq (100 mCi) for a 60 min beam, with irradiations of [68Zn]Zn(NO3)2 at 0.3 M HNO3. Target/chemistry performance was more consistent when compared with 0.2 M HNO3. Radionuclidic purity of 68Ga was typically > 99.8% at EOB and met the requirements specified in the European Pharmacopoeia (< 2% combined 66/67Ga) for a practical clinical product shelf-life. The activity yield of [68Ga]GaCl3 was typically > 50% (~ 1.85 GBq, 50 mCi); yields improved as processes were optimized. Labeling yields for [68Ga]Ga-PSMA-11 were near quantitative (~ 1.67 GBq, 45 mCi) at EOS. Cyclotron produced [68Ga]Ga-PSMA-11 underwent full quality control, stability and sterility testing, and was implemented for human use at the University of Michigan as an Investigational New Drug through the US FDA and also at the Royal Prince Alfred Hospital (RPA). CONCLUSION: Direct cyclotron irradiation of a liquid target provides clinically relevant quantities of [68Ga]Ga-PSMA-11 and is a viable alternative to traditional 68Ge/68Ga generators.

6.
EJNMMI Radiopharm Chem ; 5(1): 24, 2020 Nov 11.
Article in English | MEDLINE | ID: mdl-33175263

ABSTRACT

BACKGROUND: In the US, EU and elsewhere, basic clinical research studies with positron emission tomography (PET) radiotracers that are generally recognized as safe and effective (GRASE) can often be conducted under institutional approval. For example, in the United States, such research is conducted under the oversight of a Radioactive Drug Research Committee (RDRC) as long as certain requirements are met. Firstly, the research must be for basic science and cannot be intended for immediate therapeutic or diagnostic purposes, or to determine the safety and effectiveness of the PET radiotracer. Secondly, the PET radiotracer must be generally recognized as safe and effective. Specifically, the mass dose to be administered must not cause any clinically detectable pharmacological effect in humans, and the radiation dose to be administered must be the smallest dose practical to perform the study and not exceed regulatory dose limits within a 1-year period. In our experience, the main barrier to using a PET radiotracer under RDRC approval is accessing the required information about mass and radioactive dosing. RESULTS: The University of Michigan (UM) has a long history of using PET radiotracers in clinical research studies. Herein we provide dosing information for 55 radiotracers that will enable other PET Centers to use them under the approval of their own RDRC committees. CONCLUSIONS: The data provided herein will streamline future RDRC approval, and facilitate further basic science investigation of 55 PET radiotracers that target functionally relevant biomarkers in high impact disease states.

7.
EJNMMI Radiopharm Chem ; 4(1): 24, 2019 Sep 18.
Article in English | MEDLINE | ID: mdl-31659546

ABSTRACT

BACKGROUND: PET radiopharmaceutical development and the implementation of a production method on a synthesis module is a complex and time-intensive task since new synthesis methods must be adapted to the confines of the synthesis platform in use. Commonly utilized single fluid bus architectures put multiple constraints on synthesis planning and execution, while conventional microfluidic solutions are limited by compatibility at the macro-to-micro interface. In this work we introduce the ISAR synthesis platform and custom-tailored fluid paths leveraging up to 70 individually addressable valves on a chip-based consumable. The ISAR synthesis platform replaces traditional stopcock valve manifolds with a fluidic chip that integrates all fluid paths (tubing) and valves into one consumable and enables channel routing without the single fluid bus constraint. ISAR can scale between the macro- (10 mL), meso- (0.5 mL) and micro- (≤0.05 mL) domain seamlessly, addressing the macro-to-micro interface challenge and enabling custom tailored fluid circuits for a given application. In this paper we demonstrate proof-of-concept by validating a single chip design to address the challenge of synthesizing multiple batches of [13N]NH3 for clinical use throughout the workday. RESULTS: ISAR was installed at an academic PET Center and used to manufacture [13N]NH3 in > 96% radiochemical yield. Up to 9 batches were manufactured with a single consumable chip having parallel paths without the need to open the hot-cell. Quality control testing confirmed the ISAR-based [13N]NH3 met existing clinical release specifications, and utility was demonstrated by imaging a rodent with [13N]NH3 produced on ISAR. CONCLUSIONS: ISAR represents a new paradigm in radiopharmaceutical production. Through a new system architecture, ISAR integrates the principles of microfluidics with the standard volumes and consumables established in PET Centers all over the world. Proof-of-concept has been demonstrated through validation of a chip design for the synthesis of [13N]NH3 suitable for clinical use.

8.
EJNMMI Radiopharm Chem ; 3: 12, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30363401

ABSTRACT

BACKGROUND: We recently upgraded our [18F]fludeoxyglucose (FDG) production capabilities with the goal of futureproofing our FDG clinical supply, expanding the number of batches of FDG we can manufacture each day, and improving patient throughput in our nuclear medicine clinic. In this paper we report upgrade of the synthesis modules to the GE FASTLab 2 platform (Phase 1) and cyclotron updates (Phase 2) from both practical and regulatory perspectives. We summarize our experience manufacturing FDG on the FASTLab 2 module with a high-yielding self-shielded niobium (Nb) fluorine-18 target. RESULTS: Following installation of Nb targets for production of fluorine-18, a 55 µA beam for 22 min generated 1330 ± 153 mCi of [18F]fluoride. Using these cyclotron beam parameters in combination with the FASTLab 2, activity yields (AY) of FDG were 957 ± 102 mCi at EOS, corresponding to 72% non-corrected AY (n = 235). Our workflow, inventory management and regulatory compliance have been greatly simplified following the synthesis module and cyclotron upgrades, and patient wait times for FDG PET have been cut in half at our nuclear medicine clinic. CONCLUSIONS: The combination of FASTlab 2 and self-shielded Nb fluorine-18 targets have improved our yield of FDG, and enabled reliable and repeatable manufacture of the radiotracer for clinical use.

9.
J Labelled Comp Radiopharm ; 60(8): 375-380, 2017 06 30.
Article in English | MEDLINE | ID: mdl-28419528

ABSTRACT

[11 C]Carfentanil ([11 C]CFN) is a selective radiotracer for in vivo positron emission tomography imaging studies of the µ-opioid system that, in our laboratories, is synthesized by methylation of the corresponding carboxylate precursor with [11 C]MeOTf, and purified using a C2 solid-phase extraction cartridge. Changes in the commercial availability of common C2 cartridges have necessitated future proofing the synthesis of [11 C]CFN to maintain reliable delivery of the radiotracer for clinical imaging studies. An updated synthesis of [11 C]CFN is reported that replaces a now obsolete purification cartridge with a new commercially available version and also substitutes the organic solvents used in traditional production methods with ethanol.


Subject(s)
Carbon Radioisotopes , Fentanyl/analogs & derivatives , Positron-Emission Tomography/methods , Receptors, Opioid, mu/metabolism , Chemistry Techniques, Synthetic , Fentanyl/chemical synthesis , Fentanyl/chemistry , Radiochemistry
10.
J Nucl Med ; 58(8): 1216-1223, 2017 08.
Article in English | MEDLINE | ID: mdl-28302759

ABSTRACT

Sarcosine is a known substrate of proton-coupled amino acid transporters (PATs), which are overexpressed in selected tissues and solid tumors. Sarcosine, an N-methyl derivative of the amino acid glycine and a metabolic product of choline, plays an important role for prostate cancer aggressiveness and progression. Methods:11C-radiolabeled sarcosine was tested as a new PET imaging probe in comparison with 11C-choline in 2 prostate cancer tumor xenograft models (DU-145 and PC-3). We characterized 11C-sarcosine transport in PC-3 and LNCaP tumor cells and performed 11C-sarcosine PET with CT in the first human subject with localized Gleason 4 + 3 prostate cancer. Target metabolite analyses of sarcosine and its natural precursors, glycine and choline, were performed from independent human prostate tissues. Results: In vitro assays indicated blockage of 11C-sarcosine uptake into PC-3 and LNCaP tumor cells by excess unlabeled (cold) sarcosine. 5-hydroxy-l-tryptophan, but not 2-aminobicyclo-(2,2,1)-heptane-2-carboxylic acid, competitively inhibited 11C-sarcosine tumor cell uptake, confirming PAT-mediated transport. In vivo tumor-to-background ratios (TBRs) obtained from 11C-sarcosine PET were significantly elevated compared with 11C-choline in DU-145 (TBR: 1.92 ± 0.11 for 11C-sarcosine vs. 1.41 ± 0.13 for 11C-choline [n = 10; P < 0.002]) and PC-3 tumors (TBR: 1.89 ± 0.2 for 11C-sarcosine vs. 1.34 ± 0.16 for 11C-choline [n = 7; P < 0.002]). 11C-sarcosine produced high-contrast images in 1 case of localized clinically significant prostate cancer. Target metabolite analyses revealed significant stepwise increases of sarcosine, glycine, and choline tissue levels from benign prostate tissue to localized prostate cancer and subsequently metastatic disease. 11C-sarcosine showed a favorable radiation dosimetry with an effective dose estimate of 0.0045 mSv/MBq, resulting in 2.68 mSv for a human subject (600-MBq dose). Conclusion:11C-sarcosine is a novel radiotracer for PATs and shows initial utility for prostate cancer imaging, with potential benefit over commonly used 11C-choline.


Subject(s)
Amino Acid Transport Systems/metabolism , Carbon Radioisotopes , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/metabolism , Protons , Sarcosine/metabolism , Cell Line, Tumor , Humans , Male , Positron Emission Tomography Computed Tomography , Radiometry , Sarcosine/pharmacokinetics , Tissue Distribution
11.
EJNMMI Radiopharm Chem ; 2(1): 7, 2017.
Article in English | MEDLINE | ID: mdl-29503848

ABSTRACT

BACKGROUND: [18F]AV1451 is a commonly used radiotracer for imaging tau deposits in Alzheimer's disease (AD) and related non-AD tauopathies. Existing radiosyntheses of [18F]AV1451 require complex purifications to provide doses suitable for use in clinical imaging studies. To address this issue, we have modified the synthesis of [18F]AV1451 to use only 0.5 mg precursor, optimized the Boc-deprotection step and developed a simplified method for HPLC purification of the radiotracer. RESULTS: An optimized [18F]AV1451 synthesis using a TRACERLab FXFN module led to high radiochemical yield (202 ± 57 mCi per synthesis) and doses with excellent radiochemical purity (98 ± 1%) and good specific activity (2521 ± 623 Ci/mmol). CONCLUSION: An updated and operationally simple synthesis of [18F]AV1451 has been developed that is fully automated and prepares radiotracer doses suitable for use in clinical tau PET studies.

12.
ACS Med Chem Lett ; 7(8): 746-50, 2016 Aug 11.
Article in English | MEDLINE | ID: mdl-27563397

ABSTRACT

Clarithromycin is a potential treatment for hypersomnia acting through proposed negative allosteric modulation of GABAA receptors. We were interested whether this therapeutic benefit might extend to Parkinson's disease (PD) patients because GABAergic neurotransmission is implicated in postural control. Prior to initiating clinical studies in PD patients, we wished to better understand clarithromycin's mechanism of action. In this work we investigated whether the proposed activity of clarithromycin at the GABAA receptor is associated with the benzodiazepine binding site using in vivo [(11)C]flumazenil positron emission tomography (PET) in primates and ex vivo [(3)H]flumazenil autoradiography in rat brain. While the studies demonstrate that clarithromycin does not change the K d of FMZ, nor does it competitively displace FMZ, there is preliminary evidence from the primate PET imaging studies that clarithromycin delays dissociation and washout of flumazenil from the primate brain in a dose-dependent fashion. These findings would be consistent with the proposed GABAA allosteric modulator function of clarithromycin. While the results are only preliminary, further investigation of the interaction of clarithromycin with GABA receptors and/or GABAergic medications is warranted, and therapeutic applications of clarithromycin alone or in combination with flumazenil, to treat hyper-GABAergic status in PD at minimally effective doses, should also be pursued.

13.
Liver Int ; 36(4): 522-9, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26537012

ABSTRACT

BACKGROUND & AIMS: Cirrhosis is a complex acquired disorder of coagulation and frequent indication for transfusion of blood components. We characterised blood component use in patients with cirrhosis and compared this to transfusion guidelines. METHODS: All National Health Service trusts with representation on the British Society of Gastroenterology membership list were invited to take part. Data were collected prospectively on consecutive, unselected, hospitalised admissions with cirrhosis over 28 days. Detailed information was recorded for patients receiving blood components including indication (for bleeding or prophylaxis), type of component, laboratory indices triggering transfusion, complications, thromboembolic events and clinical outcome to day 28. RESULTS: Data on 1313 consecutive patients with cirrhosis were collected from 85 hospitals. A total of 391/1313 (30%) were transfused a blood component; in 238/391 (61%), this was for treatment of bleeding and in 153/391 (39%) for prophylaxis of bleeding. In 48/185 (26%) cases with bleeding, the haemoglobin threshold was >80 g/L prior to red blood cell transfusion. In the prophylaxis group, 238/391 (61%) received transfusion in response to an abnormal haematological value in the absence of any planned procedure. In patients transfused for procedural prophylaxis, 10/34 (29%) received fresh frozen plasma at an International Normalised Ratio lower than the threshold where a benefit would be anticipated. An in-patient thromboembolic event was recorded in 3% (35/1313) and 10% (138/1313) died by day 28. CONCLUSIONS: One-third of hospitalised patients with cirrhosis were transfused. Strategies for Patient Blood Management should include ensuring transfusion practice is consistent with guidelines and greater emphasis on alternatives to transfusion.


Subject(s)
Blood Component Transfusion/trends , Gastrointestinal Hemorrhage/therapy , Liver Cirrhosis/therapy , Practice Patterns, Physicians'/trends , Aged , Biomarkers/blood , Blood Component Transfusion/adverse effects , Blood Component Transfusion/standards , Female , Gastrointestinal Hemorrhage/blood , Gastrointestinal Hemorrhage/diagnosis , Gastrointestinal Hemorrhage/etiology , Guideline Adherence/trends , Health Care Surveys , Hemoglobins/metabolism , Humans , International Normalized Ratio , Liver Cirrhosis/blood , Liver Cirrhosis/complications , Liver Cirrhosis/diagnosis , Male , Middle Aged , Patient Admission/trends , Practice Guidelines as Topic , Practice Patterns, Physicians'/standards , Predictive Value of Tests , Risk Factors , State Medicine , Thromboembolism/etiology , Time Factors , Treatment Outcome , United Kingdom
14.
Chem Commun (Camb) ; 51(79): 14805-8, 2015 Oct 11.
Article in English | MEDLINE | ID: mdl-26300287

ABSTRACT

Green strategies for late-stage fluorination with (18)F, in which ethanol and water are the only solvents used throughout the entire radiolabeling process (azeotropic drying, nucleophilic fluorination, purification and formulation), have been developed and applied to the radiosyntheses of a range of radiopharmaceuticals commonly employed in clinical PET imaging.


Subject(s)
Ethanol/chemistry , Fluorine Radioisotopes/chemistry , Radiopharmaceuticals/chemistry , Water/chemistry
15.
ACS Chem Neurosci ; 5(8): 718-30, 2014 Aug 20.
Article in English | MEDLINE | ID: mdl-24896980

ABSTRACT

Abnormally aggregated tau is the hallmark pathology of tauopathy neurodegenerative disorders and is a target for development of both diagnostic tools and therapeutic strategies across the tauopathy disease spectrum. Development of carbon-11- or fluorine-18-labeled radiotracers with appropriate affinity and specificity for tau would allow noninvasive quantification of tau burden using positron emission tomography (PET) imaging. We have synthesized [(18)F]lansoprazole, [(11)C]N-methyl lansoprazole, and [(18)F]N-methyl lansoprazole and identified them as high affinity radiotracers for tau with low to subnanomolar binding affinities. Herein, we report radiosyntheses and extensive preclinical evaluation with the aim of selecting a lead radiotracer for translation into human PET imaging trials. We demonstrate that [(18)F]N-methyl lansoprazole, on account of the favorable half-life of fluorine-18 and its rapid brain entry in nonhuman primates, favorable kinetics, low white matter binding, and selectivity for binding to tau over amyloid, is the lead compound for progression into clinical trials.


Subject(s)
Alzheimer Disease/diagnostic imaging , Lansoprazole , Positron-Emission Tomography , Radiopharmaceuticals , Supranuclear Palsy, Progressive/diagnostic imaging , Alzheimer Disease/metabolism , Amyloid beta-Peptides/metabolism , Animals , Autoradiography , Brain/diagnostic imaging , Brain/metabolism , Carbon Radioisotopes/chemistry , Carbon Radioisotopes/pharmacokinetics , Drug Evaluation, Preclinical , Fluorine Radioisotopes/chemistry , Fluorine Radioisotopes/pharmacokinetics , Humans , Lansoprazole/chemistry , Lansoprazole/pharmacokinetics , Mice , Peptide Fragments/metabolism , Positron-Emission Tomography/methods , Primates , Radiopharmaceuticals/chemical synthesis , Radiopharmaceuticals/chemistry , Radiopharmaceuticals/pharmacokinetics , Rats , Supranuclear Palsy, Progressive/metabolism , tau Proteins/metabolism
16.
J Labelled Comp Radiopharm ; 56(12): 595-9, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24285235

ABSTRACT

(-)-[(18) F]Flubatine was selected for clinical imaging of α4 ß2 nicotinic acetylcholine receptors because of its high affinity and appropriate kinetic profile. A fully automated synthesis of (-)-[(18) F]flubatine as a sterile isotonic solution suitable for clinical use is reported, as well as the first evaluation in nonhuman primates (rhesus macaques). (-)-[(18) F]Flubatine was prepared by fluorination of the Boc-protected trimethylammonium iodide precursor with [(18) F]fluoride in an automated synthesis module. Subsequent deprotection of the Boc group with 1-M HCl yielded (-)-[(18) F]flubatine, which was purified by semi-preparative HPLC. (-)-[(18) F]Flubatine was prepared in 25% radiochemical yield (formulated for clinical use at end of synthesis, n = 3), >95% radiochemical purity, and specific activity = 4647 Ci/mmol (171.9 GBq/µmol). Doses met all quality control criteria confirming their suitability for clinical use. Evaluation of (-)-[(18) F]flubatine in rhesus macaques was performed with a Concorde MicroPET P4 scanner (Concorde MicroSystems, Knoxville, TN). The brain was imaged for 90 min, and data were reconstructed using the 3-D maximum a posteriori algorithm. Image analysis revealed higher uptake and slower washout in the thalamus than those in other areas of the brain and peak uptake at 45 min. Injection of 2.5 µg/kg of nifene at 60 min initiated a slow washout of [(18) F]flubatine, with about 25% clearance from the thalamus by the end of imaging at 90 min.


Subject(s)
Benzamides/pharmacokinetics , Bridged Bicyclo Compounds, Heterocyclic/pharmacokinetics , Fluorine Radioisotopes/pharmacokinetics , Isotope Labeling/methods , Radiopharmaceuticals/pharmacokinetics , Animals , Automation, Laboratory , Benzamides/adverse effects , Benzamides/chemical synthesis , Brain/diagnostic imaging , Bridged Bicyclo Compounds, Heterocyclic/adverse effects , Bridged Bicyclo Compounds, Heterocyclic/chemical synthesis , Drug Evaluation, Preclinical , Female , Fluorine Radioisotopes/adverse effects , Fluorine Radioisotopes/chemistry , Macaca mulatta , Positron-Emission Tomography/methods , Radiopharmaceuticals/adverse effects , Radiopharmaceuticals/chemical synthesis
17.
Nucl Med Biol ; 40(7): 901-5, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23890694

ABSTRACT

INTRODUCTION: Two 7-fluoroimidazobenzodiazepines (AH114726 and GEH120348), analogs of flumazenil, were labeled with fluorine-18 and evaluated as alternative radioligands for in vivo imaging of the GABAA/benzodiazepine receptor by comparing them to [(11)C]flumazenil in rhesus monkey. METHODS: Radiotracers were prepared from the corresponding nitro-precursors in an automated synthesis module, and primate imaging studies were conducted on a Concorde MicroPET P4 scanner. The brain was imaged for 60 (12 × 5 min frames) or 90 min (18 × 5 min frames), and data was reconstructed using the 3D MAP algorithm. Specificity of [(18)F]AH114726 and [(18)F]GEH120348 was confirmed by displacement studies using unlabeled flumazenil. RESULTS: [(18)F]GEH120348 and [(18)F]AH114726 were obtained in 13-24% yields (end of synthesis) with high chemical (>95%) and radiochemical (>99%) purities, and high specific activities (2061 ± 985 Ci/mmol). The in vivo pharmacokinetics of [(18)F]AH114726 and [(18)F]GEH120348 were determined in a non-human primate and directly compared with [(11)C]flumazenil. Both fluorine-18 radioligands showed time-dependent regional brain distributions that correlated with the distribution of [(11)C]flumazenil and the known concentrations of GABAA/benzodiazepine receptors in the monkey brain. [(18)F]AH114726 exhibited maximal brain uptake and tissue time-radioactivity curves that were most similar to [(11)C]flumazenil. In contrast, [(18)F]GEH120348 showed higher initial brain uptake but very different pharmacokinetics with continued accumulation of radioactivity into the cortical regions of high GABA/benzodiazepine receptor concentrations and very little clearance from the regions of low receptor densities. Rapid washout of both radiotracers occurred upon treatment with unlabeled flumazenil. CONCLUSION: The ease of the radiochemical synthesis, together with in vivo brain pharmacokinetics most similar to [(11)C]flumazenil, support that [(18)F]AH114726 is a suitable option for imaging the GABAA receptor.


Subject(s)
Brain/diagnostic imaging , Brain/metabolism , Flumazenil , Fluorine Radioisotopes , Positron-Emission Tomography/methods , Receptors, GABA-A/metabolism , Animals , Female , Flumazenil/chemistry , Flumazenil/pharmacokinetics , Macaca mulatta , Radiochemistry
18.
Appl Radiat Isot ; 78: 26-32, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23665261

ABSTRACT

INTRODUCTION: A novel one-pot method for preparing [(18)F]fluoromethylcholine ([(18)F]FCH) via in situ generation of [(18)F]fluoromethyl tosylate ([(18)F]FCH2OTs), and subsequent [(18)F]fluoromethylation of dimethylaminoethanol (DMAE), has been developed. METHODS: [(18)F]FCH was prepared using a GE TRACERlab FXFN, although the method should be readily adaptable to any other fluorine-(18) synthesis module. Initially ditosylmethane was fluorinated to generate [(18)F]FCH2OTs. DMAE was then added and the reaction was heated at 120 °C for 10 min to generate [(18)F]FCH. After this time, reaction solvent was evaporated, and the crude reaction mixture was purified by solid-phase extraction using C(18)-Plus and CM-Light Sep-Pak cartridges to provide [(18)F]FCH formulated in USP saline. The formulated product was passed through a 0.22 µm filter into a sterile dose vial, and submitted for quality control testing. Total synthesis time was 1.25 h from end-of-bombardment. RESULTS: Typical non-decay-corrected yields of [(18)F]FCH prepared using this method were 91 mCi (7% non-decay corrected based upon ~1.3 Ci [(18)F]fluoride), and doses passed all other quality control (QC) tests. CONCLUSION: A one-pot liquid-phase synthesis of [(18)F]FCH has been developed. Doses contain extremely low levels of residual DMAE (31.6 µg/10 mL dose or ~3 ppm) and passed all other requisite QC testing, confirming their suitability for use in clinical imaging studies.


Subject(s)
Choline/analogs & derivatives , Deanol/chemistry , Deanol/isolation & purification , Drug Contamination/prevention & control , Isotope Labeling/instrumentation , Robotics/instrumentation , Choline/chemical synthesis , Choline/isolation & purification , Equipment Design , Equipment Failure Analysis , Isotope Labeling/methods , Robotics/methods
19.
J Labelled Comp Radiopharm ; 54(6): 292-307, 2011 May 30.
Article in English | MEDLINE | ID: mdl-21769163

ABSTRACT

The field of radiochemistry is moving towards exclusive use of automated synthesis modules for production of clinical radiopharmaceutical doses. Such a move comes with many advantages, but also presents radiochemists with the challenge of re-configuring synthesis modules for production of radiopharmaceuticals that require non-conventional radiochemistry whilst maintaining full automation. This review showcases the versatility of the Tracerlab FX(FN) synthesis module by presenting simple, fully automated methods for producing [(18)F]FLT, [(18)F]FAZA, [(18)F]MPPF, [(18)F]FEOBV, [(18)F]sodium fluoride, [(18)F]fluorocholine and [(18)F]SFB.

20.
Appl Radiat Isot ; 69(4): 691-8, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21256039

ABSTRACT

As researchers explore new applications for positron emission tomography radiopharmaceuticals, the demand for effective and readily available radiopharmaceuticals continues to increase. The syntheses of two such radiopharmaceuticals, [(11)C]acetate and [(11)C]palmitate, can be automated on the GE Tracerlab FX(C-Pro) by utilizing Grignard reactions. Radiochemical purities of the [(11)C]acetate and the [(11)C]palmitate products were high (>98% and >99.9%, respectively) with average non-corrected yields of 18% (n = 3) and 10% (n = 5), respectively. These data comprise the validation trials for site qualification of clinical production of both radiopharmaceuticals.


Subject(s)
Acetic Acid/chemical synthesis , Automation , Carbon Radioisotopes/chemistry , Palmitic Acid/chemical synthesis , Positron-Emission Tomography
SELECTION OF CITATIONS
SEARCH DETAIL
...