Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Chem ; 50(1): 166-74, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14709644

ABSTRACT

BACKGROUND: The national programs for the harmonization of hemoglobin (Hb)A(1c) measurements in the US [National Glycohemoglobin Standardization Program (NGSP)], Japan [Japanese Diabetes Society (JDS)/Japanese Society of Clinical Chemistry (JSCC)], and Sweden are based on different designated comparison methods (DCMs). The future basis for international standardization will be the reference system developed by the IFCC Working Group on HbA(1c) Standardization. The aim of the present study was to determine the relationships between the IFCC Reference Method (RM) and the DCMs. METHODS: Four method-comparison studies were performed in 2001-2003. In each study five to eight pooled blood samples were measured by 11 reference laboratories of the IFCC Network of Reference Laboratories, 9 Secondary Reference Laboratories of the NGSP, 3 reference laboratories of the JDS/JSCC program, and a Swedish reference laboratory. Regression equations were determined for the relationship between the IFCC RM and each of the DCMs. RESULTS: Significant differences were observed between the HbA(1c) results of the IFCC RM and those of the DCMs. Significant differences were also demonstrated between the three DCMs. However, in all cases the relationship of the DCMs with the RM were linear. There were no statistically significant differences between the regression equations calculated for each of the four studies; therefore, the results could be combined. The relationship is described by the following regression equations: NGSP-HbA(1c) = 0.915(IFCC-HbA(1c)) + 2.15% (r(2) = 0.998); JDS/JSCC-HbA(1c) = 0.927(IFCC-HbA(1c)) + 1.73% (r(2) = 0.997); Swedish-HbA(1c) = 0.989(IFCC-HbA(1c)) + 0.88% (r(2) = 0.996). CONCLUSION: There is a firm and reproducible link between the IFCC RM and DCM HbA(1c) values.


Subject(s)
Glycated Hemoglobin/analysis , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Calibration , Glycated Hemoglobin/standards , Humans , Japan , National Health Programs , Reference Standards , Sweden , United States
2.
Clin Chem Lab Med ; 40(6): 631-4, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12211661

ABSTRACT

This paper is the first in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and with the certification of reference preparations. Other parts deal with: Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic fication of Four Reference Materials for the Determination of Enzymatic Activity of y-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary reference values is also in preparation.


Subject(s)
Enzymes/metabolism , Catalysis , Chemistry, Clinical/standards , Humans , Hydrogen-Ion Concentration , Kinetics , Quality Assurance, Health Care , Reference Standards , Reproducibility of Results , Temperature , Thermodynamics
3.
Clin Chem Lab Med ; 40(6): 643-8, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12211663

ABSTRACT

This paper is the third in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials tamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method (1). Differences are tabulated and commented on in Appendix 1.


Subject(s)
Body Temperature , Enzymes/metabolism , Chemistry, Clinical/standards , Humans , Hydrogen-Ion Concentration , Kinetics , Quality Control , Reference Standards , Thermodynamics
4.
Clin Chem Lab Med ; 40(6): 635-42, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12211662

ABSTRACT

This paper is the second in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary reference values is also in preparation. The pro- described 30 degrees C IFCC reference method (1). Differences are tabulated and commented on in Appendix 3.


Subject(s)
Body Temperature , Enzymes/metabolism , Chemistry, Clinical/methods , Chemistry, Clinical/standards , Humans , Hydrogen-Ion Concentration , Kinetics , Reference Standards , Thermodynamics
5.
Clin Chem Lab Med ; 40(7): 718-24, 2002 Jul.
Article in English | MEDLINE | ID: mdl-12241021

ABSTRACT

This paper is the fourth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 2.


Subject(s)
Alanine Transaminase/analysis , Alanine Transaminase/standards , Catalysis , Clinical Enzyme Tests/methods , Clinical Enzyme Tests/standards , Humans , Hydrogen-Ion Concentration , Kinetics , Reference Values , Solutions
6.
Clin Chem Lab Med ; 40(7): 725-33, 2002 Jul.
Article in English | MEDLINE | ID: mdl-12241022

ABSTRACT

This paper is the fifth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 3.


Subject(s)
Aspartate Aminotransferases/analysis , Aspartate Aminotransferases/standards , Catalysis , Clinical Enzyme Tests/methods , Clinical Enzyme Tests/standards , Humans , Hydrogen-Ion Concentration , Indicators and Reagents , Kinetics , Reference Values , Solutions
7.
Clin Chem Lab Med ; 40(7): 734-8, 2002 Jul.
Article in English | MEDLINE | ID: mdl-12241023

ABSTRACT

This paper is the sixth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 1.


Subject(s)
gamma-Glutamyltransferase/analysis , Catalysis , Clinical Enzyme Tests/methods , Clinical Enzyme Tests/standards , Humans , Hydrogen-Ion Concentration , Indicators and Reagents , Kinetics , Reference Values , Solutions , gamma-Glutamyltransferase/standards
8.
Clin Chem Lab Med ; 40(7): 739-45, 2002 Jul.
Article in English | MEDLINE | ID: mdl-12241024

ABSTRACT

This paper is the seventh in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase. A document describing the determination of preliminary reference values is also in preparation. The certification of the catalytic activity concentrations as determined by the recently elaborated IFCC primary reference methods at 37 degrees C of four enzyme preparations, namely IRMM/IFCC 452 (gamma-glutamyltransferase), IRMM/IFCC 453 (lactate dehydrogenase 1), IRMM/IFCC 454 (alanine aminotransferase) and IRMM/IFCC 455 (creatine kinase) is described. Homogeneity data were derived from previous results. Stability was assessed using recently obtained data as well as data from previous stability studies. The collaborative study for value assignment was performed under a strict quality control scheme to ensure traceability to the primary reference method. Uncertainty of the materials was assessed in compliance with the Guide to the Expression of Uncertainty in Measurement. The certified values obtained at 37 degrees C are 1.90 microkat/l +/- 0.04 microkat/l (114.1 U/l +/- 2.4 U/l), for gamma-glutamyltransferase, 8.37 microkat/l +/- 0.12 microkat/l (502 U/l +/- 7 U/l), for lactate dehydrogenase 1, 3.09 microkat/l +/- 0.07 microkat/l (186 U/l +/- 4 U/l), for alanine aminotransferase and 1.68 microkat/l +/- 0.07 microkat/l (101 U/l +/- 4 U/l), for creatine kinase. The materials are intended for internal quality control as well as for the evaluation of test systems as required by recent European Union legislation. Furthermore, the materials can be used to transfer accuracy from a reference method to a routine procedure provided the procedures exhibit the same analytical specificity and the certified materials are commutable.


Subject(s)
Enzymes/standards , Guidelines as Topic , Alanine Transaminase/analysis , Alanine Transaminase/standards , Clinical Enzyme Tests/methods , Clinical Enzyme Tests/standards , Creatine Kinase/analysis , Creatine Kinase/standards , Enzymes/analysis , Humans , L-Lactate Dehydrogenase/analysis , L-Lactate Dehydrogenase/standards , Quality Control , Reference Standards , Reproducibility of Results , gamma-Glutamyltransferase/analysis , gamma-Glutamyltransferase/standards
9.
Clin Chem Lab Med ; 40(1): 78-89, 2002 Jan.
Article in English | MEDLINE | ID: mdl-11916276

ABSTRACT

HbA1C is the stable glucose adduct to the N-terminal group of the beta-chain of HbA0. The measurement of HbA1c in human blood is most important for the long-term control of the glycaemic state in diabetic patients. Because there was no internationally agreed reference method the IFCC Working Group on HbA1c Standardization developed a reference method which is here described. In a first step haemoglobin is cleaved into peptides by the enzyme endoproteinase Glu-C, and in a second step the glycated and non-glycated N-terminal hexapeptides of the beta-chain obtained are separated and quantified by HPLC and electrospray ionisation mass spectrometry or in a two-dimensional approach using HPLC and capillary electrophoresis with UV-detection. Both principles give identical results. HbA1c is measured as ratio between the glycated and non-glycated hexapeptides. Calibrators consisting of mixtures of highly purified HbA1c and HbA0 are used. The analytical performance of the reference method has been evaluated by an international network of reference laboratories comprising laboratories from Europe, Japan and the USA. The intercomparison studies of the network showed excellent results with intra-laboratory CVs of 0.5 to 2% and inter-laboratory CVs of 1.4 to 2.3%. Possible interferences have been carefully investigated. Due to the higher specificity of the reference method the results are lower than those generated with most of the present commercial methods which currently are calibrated with unspecific designated comparison methods. The new reference method has been approved by the member societies of the International Federation of Clinical Chemistry and Laboratory Medicine and will be the basis for the future uniform standardization of HbA1c routine assays worldwide.


Subject(s)
Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Glycated Hemoglobin/analysis , Buffers , Calibration , Chromatography, High Pressure Liquid/instrumentation , Electrophoresis, Capillary , Europe , Glycosylation , Humans , Japan , Reference Values , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, Mass, Electrospray Ionization , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...