Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 58
Filter
1.
CJC Open ; 6(4): 649-655, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708054

ABSTRACT

Background: Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often, leadless pacemaker (LP) implantation is a de novo procedure, but in an increasing number of patients, an LP is used after previous implantation of a conventional pacing system (CPS). Methods: A retrospective analysis was conducted of the efficacy and safety of LP implantation in the context of a previously implanted CPS, from 2 large Swiss centres. Results: A total of 257 consecutive patients undergoing LP implantation were included. They were divided into 2 groups: group 1 consisted of 233 patients who did not have a previous CPS, and group 2 consisted of 24 patients with an in situ CPS. In group 2, a total of 20 patients (83%) required transvenous lead extraction due to infection, malfunction, or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, whereas in the remaining 11 cases, a time window occurred between the 2 procedures (median: 11.5 days; range: 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the 2 groups (mean: 12.5 ± 9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 instances of femoral bleeding, and 1 instance of intra-abdominal bleeding) in the entire cohort within a 30-day period. No complications occurred in the group with a previous device. No infections were registered, even when complete extraction of an infected CPS was performed prior to LP implantation. Conclusions: Implantation of an LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.


Contexte: La stimulation cardiaque sans fil a été établie comme une solution de substitution aux dispositifs transveineux chez certains patients. L'implantation d'un stimulateur cardiaque sans fil est souvent une intervention de novo, mais chez un nombre croissant de patients, ce type de stimulateur est utilisé après l'implantation d'un stimulateur classique. Méthodologie: Une analyse rétrospective de l'efficacité et de l'innocuité de la stimulation cardiaque sans fil dans le contexte de l'implantation d'un stimulateur classique a été réalisée dans deux grands centres suisses. Résultats: Un total de 257 patients consécutifs ayant subi l'implantation d'un stimulateur cardiaque sans fil ont été inclus. Les patients étaient répartis dans deux groupes; le groupe 1 était composé de 233 patients non porteurs d'un stimulateur classique, et le groupe 2, de 24 patients porteurs d'un stimulateur classique in situ. Dans le groupe 2, 20 patients au total (83 %) ont eu besoin d'une extraction de la sonde transveineuse en raison d'une infection, d'un défaut de fonctionnement, ou pour d'autres motifs. Chez 3 patients présentant une infection liée au stimulateur, l'extraction de la sonde et l'implantation d'un stimulateur cardiaque sans fil ont été réalisées simultanément, tandis que dans les 11 autres cas, il s'est écoulé un temps médian de 11,5 jours entre les deux interventions (min.-max. : 2-186 jours). Les paramètres relatifs au dispositif électrique au moment de l'implantation et pendant le suivi n'étaient pas différents entre les deux groupes (moyenne : 12,5 ± 9,3 mois). Huit complications périopératoires importantes (3,1 %) sont survenues (4 cas d'épanchement péricardique, 3 cas d'hémorragie fémorale et 1 cas d'hémorragie intra-abdominale) dans l'ensemble de la cohorte au cours d'une période de 30 jours. Aucune complication ne s'est produite dans le groupe de patients porteurs d'un stimulateur classique. On n'a enregistré aucun cas d'infection, même lorsque l'extraction complète du stimulateur classique infecté a été effectuée avant l'implantation du stimulateur cardiaque sans fil. Conclusions: L'implantation d'un stimulateur cardiaque sans fil chez les patients porteurs d'un stimulateur classique (avec ou sans extraction de ce stimulateur) était une intervention efficace et sûre dans cette population de patients.

2.
Article in English | MEDLINE | ID: mdl-38781502

ABSTRACT

OBJECTIVES: Barlow's disease is a specific sub-form of mitral valve (MV) disease, characterized by diffuse excessive tissue and multi segment prolapse. The anterolateral mini-thoracotomy represents the standard access for MV regurgitation in many centers. It still remains unclear which surgical technique provides the best results. Therefore, the aim of this study was to compare operative safety and mid-term outcomes after (a) isolated annuloplasty, (b) use of additional artificial chordae or (c) leaflet resection in patients suffering from Barlow's disease undergoing minimally invasive mitral valve repair. METHODS: A consecutive series of patients suffering from Barlow`s disease undergoing minimally invasive mitral valve surgery (MIMVS) between 2001-2020 were analyzed (n = 246). Patients were grouped and analyzed according to the used surgical technique. The primary outcome was a modified Mitral Valve Academic Research Consortium combined end-point of mortality, reoperation due to repair failure or reoccurrence of severe mitral regurgitation within 5 years. The secondary outcome included operative success and safety up to 30 days. RESULTS: No significant difference was found between the three surgical techniques in regard to the operative safety (p-value = 0.774). The primary outcome did not differ between groups (p-value = 0.244). Operative success was achieved in 93.5% and was lowest in the isolated annuloplasty group (77.1%). Conversion to mitral valve replacement was increased in patients undergoing isolated annuloplasty (p-value < 0.001). CONCLUSIONS: Isolated annuloplasty, use of additional artificial chordae and leaflet resection represent feasible techniques in Barlow patients undergoing MIMVS with comparable five-year results. In view of the increased conversion rate in the annuloplasty group, the pathology should not be oversimplified.

4.
CJC Open ; 6(2Part A): 96-103, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38585679

ABSTRACT

Background: Impairment of the conduction system is a common complication of transcatheter aortic valve replacement (TAVR), which is typically performed in elderly patients. A leadless pacemaker (LP) may be a suitable option in this frail population, but the available scientific data concerning the efficacy and safety of leadless pacing after TAVR are sparse. The purpose of this analysis was to evaluate the efficacy and safety of LP implantation in patients with relevant bradycardias after TAVR, compared to other indications. Methods: Consecutive patients were retrospectively enrolled. Demographics, background heart diseases, interventional parameters, and follow-up data were collected. Results: A total of 257 consecutive patients who underwent LP implantation were included. In 26 patients, the device was implanted due to bradycardias after TAVR (TAVR group), whereas the remaining 231 patients were in the population without previous TAVR (non-TAVR group). The mean implantation duration (56 ± 22 minutes in the TAVR group vs 48 ± 20 minutes in the non-TAVR group; P = not significant [NS]) and the implantation success rate (100% in the TAVR group vs 98.7% in the non-TAVR group; P = NS) were similar in the 2 cohorts. No significant differences occurred in pacing parameters (sensing, impedance, and threshold, respectively) between the 2 groups, either at implantation or during follow-up. A total of 8 major periprocedural complications (3.1% of patients in total; 3.8% in the TAVR group vs 3.0% in the non-TAVR group; P = NS) occurred within 30 days, without significant difference between the 2 groups. Conclusions: LP implantation appears to be safe and effective in patients after TAVR, and therefore, this procedure is a suitable option for this often old and frail population.


Contexte: L'atteinte du système de conduction cardiaque est une complication courante du remplacement valvulaire aortique par cathéter (RVAC), une intervention habituellement pratiquée chez les patients âgés. Un stimulateur cardiaque sans sonde peut être une option convenable pour cette population fragile, mais les données scientifiques actuelles concernant l'efficacité et l'innocuité de la stimulation sans sonde après un RVAC sont fragmentaires. Cette analyse visait à évaluer l'efficacité et l'innocuité de l'implantation d'un stimulateur cardiaque sans sonde chez des patients atteints de bradycardies pertinentes après un RVAC, comparativement à d'autres indications. Méthodologie: Des patients consécutifs ont été recrutés de manière rétrospective. Les données démographiques, les maladies cardiaques sous-jacentes, les paramètres interventionnels et les données de suivi ont été colligés. Résultats: Un total de 257 patients consécutifs qui se sont fait implanter un stimulateur cardiaque sans sonde ont été inclus. Chez 26 patients, le dispositif a été implanté en raison d'une bradycardie après un RVAC (groupe RVAC), alors que les 231 autres patients formaient la population sans RVAC antérieur (groupe sans RVAC). La durée moyenne de l'intervention d'implantation (56 ± 22 minutes dans le groupe RVAC vs 48 ± 20 minutes dans le groupe sans RVAC; p = non significatif [NS]) et le taux de réussite de l'implantation (100 % dans le groupe RVAC vs 98,7 % dans le groupe sans RVAC; p = NS) étaient similaires dans les deux cohortes. Aucune différence significative n'a été observée dans les paramètres de stimulation (sensibilité, impédance et seuil, respectivement) entre les 2 groupes, que ce soit au moment de l'implantation ou pendant le suivi. Un total de 8 complications périopératoires majeures (3,1 % de l'ensemble des patients; 3,8 % dans le groupe RVAC vs 3,0 % dans le groupe sans RVAC; p = NS) sont survenues dans les 30 jours, sans différence notable entre les 2 groupes. Conclusions: L'implantation d'un stimulateur cardiaque sans sonde semble sûre et efficace après un RVAC; par conséquent, cette intervention représente une option convenable pour cette population souvent âgée et fragile.

5.
Heart Rhythm ; 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38432424

ABSTRACT

BACKGROUND: Leadless pacemakers (LPs) capable of VDD pacing allow for atrioventricular synchrony through mechanical sensing of atrial contraction. However, mechanical sensing is less reliable and less predictable than electrical sensing. OBJECTIVE: The purpose of this study was to evaluate P-wave amplitude during sinus rhythm from preoperative 12-lead electrocardiograms (ECGs) as a predictor for atrial mechanical sensing in patients undergoing VDD LP implantation. METHODS: Consecutive patients undergoing VDD LP implantation were included in this 2-center prospective cohort study. ECG parameters were evaluated separately and in combination for association with the signal amplitude of atrial mechanical contraction (A4). RESULTS: Eighty patients (median age 82 years; female 55%; mean body mass index [BMI] 25.8 kg/m2) were included in the study and 61 patients in the A4 signal analysis (19 patients in VVI mode during follow-up). Absolute (aVL, aVF, V1, V2) and BMI-adjusted (I, II, aVL, aVF, aVR, V1, V2) P-wave amplitudes from baseline ECGs demonstrated a statistically significant positive correlation with A4 signal amplitude (all P <.05). A combined P-wave signal amplitude of at least 0.2 mV in V1 and aVL was predictive, with specificity of 83% (95% confidence interval 67%-100%) for A4 signal ≥1 m/s2. We found a significant correlation of A4 signal amplitude and overall atrioventricular synchrony (P = .013). CONCLUSION: P-wave amplitudes in ECG leads aVL and V1 can predict A4 signal amplitude in patients with VDD LP and therefore the probability of successful AV synchronous pacing.

6.
Front Cardiovasc Med ; 11: 1343424, 2024.
Article in English | MEDLINE | ID: mdl-38322767

ABSTRACT

Introduction: Implantable cardiac monitors (ICMs) provide long-term arrhythmia monitoring, but high rates of false detections increase the review burden. The new "SmartECG" algorithm filters false detections. Using large real-world data sets, we aimed to quantify the reduction in workload and any loss in sensitivity from this new algorithm. Methods: Patients with a BioMonitor IIIm and any device indication were included from three clinical projects. All subcutaneous ECGs (sECGs) transmitted via remote monitoring were classified by the algorithm as "true" or "false." We quantified the relative reduction in workload assuming "false" sECGs were ignored. The remote monitoring workload from five hospitals with established remote monitoring routines was evaluated. Loss in sensitivity was estimated by testing a sample of 2000 sECGs against a clinical board of three physicians. Results: Of our population of 368 patients, 42% had an indication for syncope or pre-syncope and 31% for cryptogenic stroke. Within 418.5 patient-years of follow-up, 143,096 remote monitoring transmissions contained 61,517 sECGs. SmartECG filtered 42.8% of all sECGs as "false," reducing the number per patient-year from 147 to 84. In five hospitals, nine trained reviewers inspected on average 105 sECGs per working hour. This results in an annual working time per patient of 83 min without SmartECG, and 48 min with SmartECG. The loss of sensitivity is estimated as 2.6%. In the majority of cases where true arrhythmias were rejected, SmartECG classified the same type of arrhythmia as "true" before or within 3 days of the falsely rejected sECG. Conclusion: SmartECG increases efficiency in long-term arrhythmia monitoring using ICMs. The reduction of workload by SmartECG is meaningful and the risk of missing a relevant arrhythmia due to incorrect filtering by the algorithm is limited.

7.
Article in English | MEDLINE | ID: mdl-38345706

ABSTRACT

BACKGROUND: Persistent left superior vena cava (PLSVC) is a rare venous anomaly, affecting 0.3-0.5% of the general population. Cardiac resynchronization therapy (CRT) implantation in patients with PLSVC is challenging due to a complex anatomy. Moreover, data on CRT implantation in this patient population is scarce. Our aim was to report a series of patients with PLSVC and CRT implantation focusing on challenges and pitfalls. METHODS: Electronic medical databases on patients with CRT implantation at the University Heart Centers in Zurich, Switzerland, and Lübeck, Germany, were screened for individuals with a PLSVC. Clinical and demographic characteristics as well as procedural data were reported in all patients. RESULTS: This study presents six cases with a median age of 66 years. CRT implantation was successful in five patients, leading to a reduced QRS duration and improved left ventricular ejection fraction. Atrial fibrillation, ischemic cardiomyopathy, valvular heart disease, and dilated cardiomyopathy were observed in this group as underlying conditions. Specialized tools, such as active fixation left ventricular leads, were utilized. One patient experienced major complications. CONCLUSIONS: This case series shows that although challenging, conventional endovascular CRT implantation is feasible in PLSVC patients. Specialized tools for visualization and fixation may help. Our experiences highlight the importance of preprocedural evaluation of the anatomy and precise intervention planning.

9.
Heart Rhythm ; 20(10): 1429-1435, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37481220

ABSTRACT

BACKGROUND: The impact of sex in clinical and procedural outcomes in leadless pacemaker (LPM) patients has not yet been investigated. OBJECTIVE: The purpose of this study was to investigate sex-related differences in patients undergoing LPM implantation. METHODS: Consecutive patients enrolled in the i-LEAPER registry were analyzed. Comparisons between sexes were performed within the overall cohort using an adjusted analysis with 1:1 propensity matching for age and comorbidities. The primary outcome was the comparison of major complication rates. Sex-related differences regarding electrical performance and all-cause mortality during follow-up were deemed secondary outcomes. RESULTS: In the overall population (n = 1179 patients; median age 80 years), 64.3% were men. After propensity matching, 738 patients with no significant baseline differences among groups were identified. During median follow-up of 25 [interquartile range 24-39] months, female sex was not associated with LPM-related major complications (hazard ratio [HR] 2.03; 95% confidence interval [CI] 0.70-5.84; P = .190) or all-cause mortality (HR 0.98; 95% CI 0.40-2.42; P = .960). LPM electrical performance results were comparable between groups, except for a higher pacing impedance in women at implant and during follow-up (24 months: 670 [550-800] Ω vs 616 [530-770] Ω; P = .014) that remained within normal limits. CONCLUSION: In a real-world setting, we found differences in sex-related referral patterns for LPM implantation with an underrepresentation of women, although major complication rate and LPM performance were comparable between sexes. Female patients showed higher impedance values, which had no impact on overall device performance. Electrical parameters remained within normal limits in both groups during the entire follow-up.

10.
Cardiology ; 148(5): 441-447, 2023.
Article in English | MEDLINE | ID: mdl-37487479

ABSTRACT

INTRODUCTION: Long-term complication rates in standard transvenous pacemakers are reported around 4-12% with a higher incidence in the elderly population. We report our experience in octogenarians undergoing leadless pacemaker implantation in two large-volume centers in Switzerland. METHODS: Consecutive patients undergoing leadless pacemaker implantation at two Swiss large volume centers (University Hospital Zurich, Zurich and Cardiocentro Ticino Institute, Lugano) between October 2015 and March 2020 were included in this retrospective analysis. Demographic information, clinical data, and procedural characteristics were recorded at the day of implantation and during follow-up. RESULTS: Two hundred and twenty patients (mean age 80.6 ± 7.7 years, male 66%) were included. The main indication for pacemaker implantation was slow ventricular rate atrial fibrillation (111 of 220 patients, 50.4%). Out of the 220 patients, 124 (56.3%) were ≥80 years. Overall successful implantation rate was 98.6%. In the octogenarian population, the median procedure time (45 ± 20.2 min vs. 40 ± 19.6 min, p = 0.03) and radiation duration (6.1 ± 8.2 min vs. 5.0 ± 7.2 min, p = 0.03) were longer compared to patients <80 years. Major complications (2.7%, n = 6) and device measurements during follow-up were similar between patients ≥80 and <80 years. CONCLUSION: Implantation of a leadless pacemaker device in octogenarians is safe and effective with a similarly low complication rate compared to non-octogenarians.


Subject(s)
Atrial Fibrillation , Pacemaker, Artificial , Aged, 80 and over , Humans , Male , Aged , Octogenarians , Retrospective Studies , Treatment Outcome , Atrial Fibrillation/therapy , Ventricular Fibrillation , Equipment Design
11.
J Clin Med ; 12(11)2023 May 26.
Article in English | MEDLINE | ID: mdl-37297892

ABSTRACT

AIMS: Association of two-(2D) and three-dimensional (3D) left atrial strain (LAS) and low-voltage area (LVA) with recurrence of atrial fibrillation (AF) after pulmonary vein isolation (PVI) was assessed. METHODS AND RESULTS: 3D LAS, 2D LAS, and LVA were obtained in 93 consecutive patients undergoing PVI and recurrence of AF was analyzed prospectively. AF recurred in 12 patients (13%). The 3D left atrial reservoir strain (LARS) and pump strain (LAPS) were lower in patients with recurrent AF than without (p = 0.008 and p = 0.009, respectively). In univariable Cox regression, 3D LARS or LAPS were associated with recurrent AF (LARS: HR = 0.89 (0.81-0.99), p = 0.025; LAPS: HR = 1.40 (1.02-1.92), p = 0.040), while other values were not. Association of 3D LARS or LAPS with recurrent AF was independent of age, body mass index, arterial hypertension, left ventricular ejection fraction, and end-diastolic volume index and left atrial volume index in multivariable models. Kaplan-Meier curves revealed that patients with 3D LAPS < -5.9% did not exhibit recurrent AF, while those >-5.9% had a significant risk of recurrent AF. CONCLUSIONS: 3D LARS and LAPS were associated with recurrent AF after PVI. Association of 3D LAS was independent of relevant clinical and echocardiographic parameters and improved their predictive value. Hence, they may be applied for outcome prediction in patients undergoing PVI.

12.
J Cardiovasc Electrophysiol ; 34(8): 1738-1743, 2023 08.
Article in English | MEDLINE | ID: mdl-37343057

ABSTRACT

INTRODUCTION: Transvenous lead extraction has become a frequent procedure in the context of device lead management and various tools are available. The aim of this study was to investigate the efficacy and safety of the novel short rotating dilator sheath TightRailTM Sub-C (Sub-C) in transvenous lead extraction. METHODS: For this retrospective single-center analysis, we included consecutive patients undergoing transvenous lead extraction using the Sub-C from January 2018 until February 2020 at the University Heart Center Zurich. RESULTS: A total of 87 leads were extracted within 45 patients using the Sub-C extraction sheath. The mean dwell time of the leads was 112 ± 9.1 months. Complete procedural success was achieved in 95.6% (43/45) and clinical procedural success in 97.8% (44/45). Two major complications (4.4%, 2/45) occurred, but neither was directly related to the Sub-C. CONCLUSION: This retrospective single-center analysis suggests that transvenous lead extraction with a routine use of the TightRailTM Sub-C extraction sheath is a safe strategy resulting in high success rates that may offer useful theoretical benefits. Future studies are needed to evaluate the incremental benefit of a routine use of short extraction sheaths including the Sub-C during TLE procedures.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Retrospective Studies , Device Removal/methods , Equipment Design , Equipment Failure , Treatment Outcome
13.
Front Cardiovasc Med ; 10: 1148052, 2023.
Article in English | MEDLINE | ID: mdl-37025684

ABSTRACT

Background: Fat layers in obese patients can impair R-wave detection and diagnostic performance of a subcutaneous insertable cardiac monitor (ICM). We compared safety and ICM sensing quality between obese patients [body mass index (BMI) ≥ 30 kg/m2] and normal-weight controls (BMI <30 kg/m2) in terms of R-wave amplitude and time in noise mode (noise burden) detected by a long-sensing-vector ICM. Materials and methods: Patients from two multicentre, non-randomized clinical registries are included in the present analysis on January 31, 2022 (data freeze), if the follow-up period was at least 90 days after ICM insertion, including daily remote monitoring. The R-wave amplitudes and daily noise burden averaged intraindividually for days 61-90 and days 1-90, respectively, were compared between obese patients (n = 104) and unmatched (n = 268) and a nearest-neighbour propensity score (PS) matched (n = 69) normal-weight controls. Results: The average R-wave amplitude was significantly lower in obese (median 0.46 mV) than in normal-weight unmatched (0.70 mV, P < 0.0001) or PS-matched (0.60 mV, P = 0.003) patients. The median noise burden was 1.0% in obese patients, which was not significantly higher than in unmatched (0.7%; P = 0.056) or PS-matched (0.8%; P = 0.133) controls. The rate of adverse device effects during the first 90 days did not differ significantly between groups. Conclusion: Although increased BMI was associated with reduced signal amplitude, also in obese patients the median R-wave amplitude was >0.3 mV, a value which is generally accepted as the minimum level for adequate R-wave detection. The noise burden and adverse event rates did not differ significantly between obese and normal-weight patients.Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04075084 and NCT04198220.

14.
Heart Rhythm O2 ; 4(2): 97-102, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36873314

ABSTRACT

Background: Insertable cardiac monitors (ICMs) are increasingly used for cardiac rhythm diagnosis with expanding indications. Little has been reported about their use and efficacy. Objective: The study sought to evaluate the clinical utility of a novel ICM (Biotronik BIOMONITOR III) including the time to diagnosis in unselected patients with different ICM indications. Methods: Patients from 2 prospective clinical studies were included to determine the diagnostic yield of the ICM. The primary endpoint was time to clinical diagnosis per implant indication or to the first change in atrial fibrillation (AF) therapy. Results: A total of 632 patients were included with a mean follow-up of 233 ± 168 days. Of 384 patients with (pre)syncope, 34.2% had a diagnosis at 1 year. The most frequent therapy was permanent pacemaker implantation. Of 133 patients with cryptogenic stroke, 16.6% had an AF diagnosis at 1 year, resulting in oral anticoagulation. Of 49 patients with an indication for AF monitoring, 41.0% had a relevant change in AF therapy based on ICM data at 1 year. Of 66 patients with other indications, 35.4% received a rhythm diagnosis at 1 year. Moreover, 6.5% of the cohort had additional diagnoses: 26 of 384 patients with syncope, 8 of 133 patients with cryptogenic stroke, and 7 of 49 patients with AF monitoring. Conclusion: In a large unselected patient population with heterogeneous ICM indications, the primary endpoint of rhythm diagnosis was achieved in ∼1 in 4, and additional clinically relevant findings was achieved in 6.5% of patients at short-term follow-up.

15.
Heart ; 109(15): 1146-1152, 2023 07 12.
Article in English | MEDLINE | ID: mdl-36889907

ABSTRACT

INTRODUCTION: Implantable cardioverter-defibrillators (ICDs) can prevent sudden cardiac death due to ventricular arrhythmias in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). The aim of our study was to assess the cumulative burden, evolution and potential triggers of appropriate ICD shocks during long-term follow-up, which may help to reduce and further refine individual arrhythmic risk in this challenging disease. METHODS: This retrospective cohort study included 53 patients with definite ARVC according to the 2010 Task Force Criteria from the multicentre Swiss ARVC Registry with an implanted ICD for primary or secondary prevention. Follow-up was conducted by assessing all available patient records from patient visits, hospitalisations, blood samples, genetic analysis, as well as device interrogation and tracings. RESULTS: Fifty-three patients (male 71.7%, mean age 43±2.2 years, genotype positive 58.5%) were analysed during a median follow-up of 7.9 (IQR 10) years. In 29 (54.7%) patients, 177 appropriate ICD shocks associated with 71 shock episodes occurred. Median time to first appropriate ICD shock was 2.8 (IQR 3.6) years. Long-term risk of shocks remained high throughout long-term follow-up. Shock episodes occurred mainly during daytime (91.5%, n=65) and without seasonal preference. We identified potentially reversible triggers in 56 of 71 (78.9%) appropriate shock episodes, the main triggers representing physical activity, inflammation and hypokalaemia. CONCLUSION: The long-term risk of appropriate ICD shocks in patients with ARVC remains high during long-term follow-up. Ventricular arrhythmias occur more often during daytime, without seasonal preference. Reversible triggers are frequent with the most common triggers for appropriate ICD shocks being physical activity, inflammation and hypokalaemia in this patient population.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Defibrillators, Implantable , Hypokalemia , Tachycardia, Ventricular , Humans , Male , Adult , Middle Aged , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Arrhythmogenic Right Ventricular Dysplasia/therapy , Retrospective Studies , Hypokalemia/complications , Follow-Up Studies , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/complications , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/epidemiology , Defibrillators, Implantable/adverse effects , Inflammation , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/complications
16.
Article in English | MEDLINE | ID: mdl-36866493

ABSTRACT

OBJECTIVES: Minimally invasive mitral valve surgery (MIMVS) has evolved over the last 2 decades. The aim of the study was to identify the impact of era and technical improvements on perioperative outcome after MIMVS. METHODS: A tota of 1000 patients (mean age: 60.8 ± 12.7 years, 60.3% male) underwent video-assisted or totally endoscopic MIMVS between 2001 and 2020 in a single institution. Three technical modalities were introduced during the observed period: (i) 3D visualization, (ii) use of premeasured artificial chordae (PTFE loops) and (iii) preoperative CT scans. Comparisons were made before and after the introduction of technical improvements. RESULTS: A total of 741 patients underwent isolated mitral valve (MV) procedure, whereas 259 received concomitant procedures. These consisted of tricuspid valve repair (208), left atrium ablation (145) and persistent foramen ovale or atrial septum defect (ASD) closure (172). The aetiology was degenerative in 738 (73.8%) patients and functional in 101 patients (10.1%). A total of 900 patients received MV repair (90%), and 100 patients (10%) underwent MV replacement. Perioperative survival was 99.1%, and periprocedural success 93.5% with a periprocedural safety of 96.3%. Improvement in periprocedural safety attributed to the lower rates of postoperative low output (P = 0.025) and less reoperations for bleeding (P < 0.001). 3D visualization improved cross-clamp (P = 0.001) but not cardiopulmonary bypass times. The use of loops and preoperative CT scan both had no impact on periprocedural success or safety but improved cardiopulmonary bypass and cross-clamp times (both P < 0.001). CONCLUSIONS: Increased surgical experience improves safety in MIMVS. Technical improvements are related to increased operative success and decreased operative times in patients undergoing MIMVS.

17.
J Clin Med ; 12(6)2023 Mar 14.
Article in English | MEDLINE | ID: mdl-36983262

ABSTRACT

INTRODUCTION: Transvenous lead extractions are increasingly performed for malfunction or infection of cardiac implantable electronic devices, but they harvest a potential for complications and suboptimal success. Apart from multicenter registries and reports from highly experienced single centers, the outcome in individual newly developing high-volume centers starting a lead extraction program is less well established. We aimed to evaluate the clinical and radiological success and complication rate at our center, having started a lead extraction program less than a decade ago. METHODS: We retrospectively analyzed patients who underwent transvenous lead extraction at the University Hospital Zurich from 2013 to 2021 regarding success as well as complications and compared our results to previously reported outcome rates. RESULTS: A total of 346 patients underwent 350 transvenous lead extractions from January 2013 to December 2021. Combined radiological success was achieved in 97.7% and clinical success in 96.0% of interventions. Procedure-related major complications occurred in 13 patients (3.7%). Death within 30 days after transvenous lead extractions occurred in 13 patients (3.7%), with a procedure-related mortality of 1.4% (five patients). SUMMARY: Transvenous lead extractions in newly developing high-volume centers can be performed with high clinical and radiological success rates, but procedure-related major complications may affect a relevant number of patients. Compared to large single or multicenter registries of experienced centers, the success rate may be lower and the complication rate higher in centers newly starting with lead extraction, which may have important implications for patient selection, procedural planning, proctoring, and safety measures.

19.
J Cardiovasc Dev Dis ; 10(1)2023 Jan 11.
Article in English | MEDLINE | ID: mdl-36661923

ABSTRACT

BACKGROUND: For mitral valve surgery (MVS) in elderly, frail patients with increasing life expectancy, finding the least harmful means of access is a challenge. In the complexity of MVS approach evolution, using three different approaches (mini-thoracotomy (MT), partial upper-sternotomy (PS), full-sternotomy (FS), we developed a personalized, minimized-invasiveness algorithm for MVS. METHODS: In this retrospective analysis, 517 elderly patients (≥70 years) were identified who had undergone MVS ± TV repair. MVS was performed via MT (n = 274), FS (n = 128) and PS (n = 115). The appropriate access type was defined according to several clinical patient conditions. Using uni- and multivariate regression models, we analyzed combined operative success (residual MV regurgitation, conversion to MV replacement or larger thoracic incisions); perioperative success (30-days mortality, thoracotomy, ECMO, pacemaker implantation, dialysis, longer ventilation); and reoperation-free long-term survival. An additional EuroSCORE2 adjustment was performed to reduce the bias of clinical conditions between all access types. RESULTS: The EuroSCORE2-adjusted Cox regression analysis showed significantly increased reoperation-free survival in the MT cohort compared to FS (HR 0.640; 95% CI 0.442-0.926; p = 0.018). Mortality was additionally reduced after the implementation of PS (p = 0.023). Combined operative success was comparable between the three access types. The perioperative success was higher in the MT cohort compared to FS (OR 2.19, 95% CI 1.32-3.63; p = 0.002). CONCLUSION: Less-invasive approaches in elderly patients improve perioperative success and reoperation-free survival in those undergoing MVS procedures.

20.
J Cardiovasc Electrophysiol ; 34(6): 1350-1359, 2023 06.
Article in English | MEDLINE | ID: mdl-36598422

ABSTRACT

INTRODUCTION: The Heliostar™ ablation system is a novel RF balloon ablation technology with an integrated three-dimensional mapping system. Here, we describe our early experience and procedural outcomes using this technology for atrial fibrillation catheter ablation. METHODS: We sought to comprehensively assess the first 60 consecutive patients undergoing pulmonary vein isolation using the novel HELISOTAR™ RF balloon technology including procedural outcomes. A comparison of the workflow between two different anaesthetic modalities (conscious sedation [CS] vs. general anaesthesia [GA]) was made. Procedural data were collected prospectively from two high-volume centers (Barts Heart Centre, UK and University Hospital of Zurich, Zurich). A standardized approach for catheter ablation was employed. RESULTS: A total of 35 patients had the procedure under CS and the remaining under GA. Mean procedural and fluoroscopy times were 84 ± 33 min and 1.1 min. The median duration of RF energy application was 7 (5-9.8) mins per patient. All veins were successfully isolated, and the median isolation time was 10 (7-15) seconds. Our cohort's rate of procedural complications was low, with no mortality within 30 days postprocedure. CONCLUSION: Our early experience shows that catheter ablation using the Heliostar™ technology can be performed efficiently and safely; however, long-term data is yet to be established. Low fluoroscopy requirements, short learning curves and use of this technology with CS is possible, including the use of an oesophageal temperature probe.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Treatment Outcome , Europe , Electrodes , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods
SELECTION OF CITATIONS