Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
Epilepsy Behav Rep ; 25: 100644, 2024.
Article in English | MEDLINE | ID: mdl-38274142

ABSTRACT

For acute treatment of seizure clusters in patients with epilepsy, intranasal administration of acute seizure therapies has been shown to provide accessibility and ease of use to care partners as well as the potential for self-administration by patients. Diazepam nasal spray (Valtoco®) was approved by the US Food and Drug Administration for acute treatment of intermittent, stereotypic episodes of frequent seizure activity (ie, seizure clusters, acute repetitive seizures) in patients with epilepsy aged ≥6 years. Self-administration consistent with the prescribing information is feasible and was reported by a subgroup of patients (n = 27 of 163) in a long-term phase 3 safety study. Data regarding self-administration among these patients with seizure clusters are examined here to explore the safety profiles and measures of effectiveness, as well as the quality of life of those who self-treated. In addition, this focused look at patients who self-administered diazepam nasal spray may offer some insights into the characteristics of patients who may be appropriate for self-administration.

3.
Brain ; 146(8): 3404-3415, 2023 08 01.
Article in English | MEDLINE | ID: mdl-36852571

ABSTRACT

Focal cortical dysplasia (FCD) type II is a highly epileptogenic developmental malformation and a common cause of surgically treated drug-resistant epilepsy. While clinical observations suggest frequent occurrence in the frontal lobe, mechanisms for such propensity remain unexplored. Here, we hypothesized that cortex-wide spatial associations of FCD distribution with cortical cytoarchitecture, gene expression and organizational axes may offer complementary insights into processes that predispose given cortical regions to harbour FCD. We mapped the cortex-wide MRI distribution of FCDs in 337 patients collected from 13 sites worldwide. We then determined its associations with (i) cytoarchitectural features using histological atlases by Von Economo and Koskinas and BigBrain; (ii) whole-brain gene expression and spatiotemporal dynamics from prenatal to adulthood stages using the Allen Human Brain Atlas and PsychENCODE BrainSpan; and (iii) macroscale developmental axes of cortical organization. FCD lesions were preferentially located in the prefrontal and fronto-limbic cortices typified by low neuron density, large soma and thick grey matter. Transcriptomic associations with FCD distribution uncovered a prenatal component related to neuroglial proliferation and differentiation, likely accounting for the dysplastic makeup, and a postnatal component related to synaptogenesis and circuit organization, possibly contributing to circuit-level hyperexcitability. FCD distribution showed a strong association with the anterior region of the antero-posterior axis derived from heritability analysis of interregional structural covariance of cortical thickness, but not with structural and functional hierarchical axes. Reliability of all results was confirmed through resampling techniques. Multimodal associations with cytoarchitecture, gene expression and axes of cortical organization indicate that prenatal neurogenesis and postnatal synaptogenesis may be key points of developmental vulnerability of the frontal lobe to FCD. Concordant with a causal role of atypical neuroglial proliferation and growth, our results indicate that FCD-vulnerable cortices display properties indicative of earlier termination of neurogenesis and initiation of cell growth. They also suggest a potential contribution of aberrant postnatal synaptogenesis and circuit development to FCD epileptogenicity.


Subject(s)
Focal Cortical Dysplasia , Malformations of Cortical Development , Humans , Reproducibility of Results , Malformations of Cortical Development/diagnostic imaging , Malformations of Cortical Development/genetics , Malformations of Cortical Development/pathology , Brain/pathology , Magnetic Resonance Imaging/methods
4.
Clin Neurophysiol ; 146: 77-86, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36549264

ABSTRACT

OBJECTIVE: Central-positive complexes (CPCs) are elicited during electroconvulsive therapy (ECT) as generalized high-amplitude waveforms with maximum positive voltage over the vertex. While these complexes have been qualitatively assessed in previous literature, quantitative analyses are lacking. This study aims to characterize CPCs across temporal, spatial, and spectral domains. METHODS: High-density 64-electrode electroencephalogram (EEG) recordings during 50 seizures acquired from 11 patients undergoing right unilateral ECT allowed for evaluation of spatiotemporal characteristics of CPCs via source localization and spectral analysis. RESULTS: Peak-amplitude CPC scalp topology was consistent across seizures, showing maximal positive polarity over the midline fronto-central region and maximal negative polarity over the suborbital regions. The sources of these peak potentials were localized to the bilateral medial thalamus and cingulate cortical regions. Delta, beta, and gamma oscillations were correlated with the peak amplitude of CPCs during seizures induced during ketamine, whereas delta and gamma oscillations were associated with CPC peaks during etomidate anesthesia (excluding the dose-charge titration). CONCLUSIONS: Our findings demonstrate the consistency of CPC presence across participant, stimulus charge, time, and anesthetic agent, with peaks localized to bilateral medial thalamus and cingulate cortical regions and associated with delta, beta, and gamma band oscillations (depending on the anesthetic condition). SIGNIFICANCE: The consistency and reproducibility of CPCs offers ECT as a new avenue for studying the dynamics of generalized seizure activity and thalamocortical networks.


Subject(s)
Electroconvulsive Therapy , Ketamine , Humans , Electroconvulsive Therapy/adverse effects , Reproducibility of Results , Seizures , Electroencephalography
5.
Front Psychiatry ; 13: 996733, 2022.
Article in English | MEDLINE | ID: mdl-36405897

ABSTRACT

Introduction: Electroconvulsive therapy (ECT) is an effective intervention for patients with major depressive disorder (MDD). Despite longstanding use, the underlying mechanisms of ECT are unknown, and there are no objective prognostic biomarkers that are routinely used for ECT response. Two electroencephalographic (EEG) markers, sleep slow waves and sleep spindles, could address these needs. Both sleep microstructure EEG markers are associated with synaptic plasticity, implicated in memory consolidation, and have reduced expression in depressed individuals. We hypothesize that ECT alleviates depression through enhanced expression of sleep slow waves and sleep spindles, thereby facilitating synaptic reconfiguration in pathologic neural circuits. Methods: Correlating ECT Response to EEG Markers (CET-REM) is a single-center, prospective, observational investigation. Wireless wearable headbands with dry EEG electrodes will be utilized for at-home unattended sleep studies to allow calculation of quantitative measures of sleep slow waves (EEG SWA, 0.5-4 Hz power) and sleep spindles (density in number/minute). High-density EEG data will be acquired during ECT to quantify seizure markers. Discussion: This innovative study focuses on the longitudinal relationships of sleep microstructure and ECT seizure markers over the treatment course. We anticipate that the results from this study will improve our understanding of ECT.

6.
J Neuroimmunol ; 373: 578000, 2022 12 15.
Article in English | MEDLINE | ID: mdl-36410057

ABSTRACT

This study aimed to investigate prognostic significance and brain metabolic mechanism of hyponatremia in anti-leucine-rich glioma-inactivated protein 1 (LGI1) encephalitis. After adjusting for confounders, patients with moderate and severe hyponatremia had significantly increased risk of poor functional outcome and sequelae of seizures. In addition, serum sodium was negatively correlated with normalized ratio of the standardized uptake value of medial temporal lobe (MTL), basal ganglia (BG), and hypothalamus on positron emission tomography (PET) and which was further validated using voxel-wise analysis, suggesting an extra-hypothalamus (BG and MTL) localization for hyponatremia.


Subject(s)
Encephalitis , Glioma , Hyponatremia , Humans , Prognosis , Hyponatremia/diagnostic imaging , Leucine
7.
Clin Neurophysiol ; 142: 125-132, 2022 10.
Article in English | MEDLINE | ID: mdl-36030576

ABSTRACT

OBJECTIVE: Periods of low-amplitude electroencephalographic (EEG) signal (quiescence) are present during both anesthetic-induced burst suppression (BS) and postictal generalized electroencephalographic suppression (PGES). PGES following generalized seizures induced by electroconvulsive therapy (ECT) has been previously linked to antidepressant response. The commonality of quiescence during both BS and PGES motivated trials to recapitulate the antidepressant effects of ECT using high doses of anesthetics. However, there have been no direct electrographic comparisons of these quiescent periods to address whether these are distinct entities. METHODS: We compared periods of EEG quiescence recorded from two human studies: BS induced in 29 healthy adult volunteers by isoflurane general anesthesia and PGES in 11 patients undergoing right unilateral ECT for treatment-resistant depression. An automated algorithm allowed detection of EEG quiescence based on a 10-microvolt amplitude threshold. Spatial, spectral, and temporal analyses compared quiescent epochs during BS and PGES. RESULTS: The median (interquartile range) voltage for quiescent periods during PGES was greater than during BS (1.81 (0.22) microvolts vs 1.22 (0.33) microvolts, p < 0.001). Relative power was greater for quiescence during PGES than BS for the 1-4 Hz delta band (p < 0.001), at the expense of power in the theta (4-8 Hz, p < 0.001), beta (13-30 Hz, p = 0.04) and gamma (30-70 Hz, p = 0.006) frequency bands. Topographic analyses revealed that amplitude across the scalp was consistently higher for quiescent periods during PGES than BS, whose voltage was within the noise floor. CONCLUSIONS: Quiescent epochs during PGES and BS have distinct patterns of EEG signals across voltage, frequency, and spatial domains. SIGNIFICANCE: Quiescent epochs during PGES and BS, important neurophysiological markers for clinical outcomes, are shown to have distinct voltage and frequency characteristics.


Subject(s)
Electroconvulsive Therapy , Isoflurane , Adult , Algorithms , Electroencephalography , Humans , Seizures/diagnosis
8.
MMWR Morb Mortal Wkly Rep ; 71(21): 703-708, 2022 May 27.
Article in English | MEDLINE | ID: mdl-35617146

ABSTRACT

Seizures, transient signs or symptoms caused by abnormal surges of electrical activity in the brain, can result from epilepsy, a neurologic disorder characterized by abnormal electrical brain activity causing recurrent, unprovoked seizures, or from other inciting causes, such as high fever or substance abuse (1). Seizures generally account for approximately 1% of all emergency department (ED) visits (2,3). Persons of any age can experience seizures, and outcomes might range from no complications for those with a single seizure to increased risk for injury, comorbidity, impaired quality of life, and early mortality for those with epilepsy (4). To examine trends in weekly seizure- or epilepsy-related (seizure-related) ED visits† in the United States before and during the COVID-19 pandemic, CDC analyzed data from the National Syndromic Surveillance Program (NSSP).§ Seizure-related ED visits decreased abruptly during the early pandemic period. By the end of 2020, seizure-related ED visits returned almost to prepandemic levels for persons of all ages, except children aged 0-9 years. By mid-2021, however, this age group gradually returned to baseline as well. Reasons for the decrease in seizure-related ED visits in 2020 among all age groups and the slow return to baseline among children aged 0-9 years compared with other age groups are unclear. The decrease might have been associated with fear of exposure to COVID-19 infection in EDs deterring parents or guardians of children from seeking care, adherence to mitigation measures including avoiding public settings such as EDs, or increased access to telehealth services decreasing the need for ED visits (5). These findings reinforce the importance of understanding factors associated with ED avoidance among persons with epilepsy or seizure, the importance that all eligible persons be up to date¶ with COVID-19 vaccination, and the need to encourage persons to seek appropriate care for seizure-related emergencies** to prevent adverse outcomes.


Subject(s)
COVID-19 , Epilepsy , COVID-19/epidemiology , COVID-19 Vaccines , Child , Child, Preschool , Emergency Service, Hospital , Epilepsy/epidemiology , Humans , Infant , Infant, Newborn , Pandemics , Quality of Life , Seizures/epidemiology , United States/epidemiology
9.
Epilepsia ; 63(4): 836-843, 2022 04.
Article in English | MEDLINE | ID: mdl-35112342

ABSTRACT

OBJECTIVE: An exploratory analysis from a long-term, phase 3, open-label, repeat-dose safety study of diazepam nasal spray for acute treatment of seizure clusters assessed the use of a second dose up to 24 hours after the initial dose and effectiveness in potentially reducing the number of seizures. METHODS: Seizures and doses were recorded in diaries. RESULTS: Of 175 patients enrolled, 163 received ≥1 dose of diazepam nasal spray and were included in the safety population; those patients received a total of 4390 doses for a total of 3853 seizure clusters. Less than half of these patients used a second dose a least once during the study (79 patients [48.5%]), with a total of 485 second doses for seizure clusters (12.6% of all seizure clusters). Among these 79 patients, 33 (41.8%) used only one second dose during the study (range: 1-82). The proportion of seizure clusters treated with a second dose over time was consistently low across 24 h: 0-4 h, 152 (3.9%); 4-6 h, 72 (1.9%); 6-8 h, 39 (1.0%); 8-12 h, 55 (1.4%); 12-16 h, 42 (1.1%); 16-20 h, 42 (1.1%); 20-24 h, 83 (2.2%). Rates of treatment-emergent adverse events (TEAEs) and treatment-related TEAEs occurring within 1 day of a second dose were low (15.2% and 5.1%, respectively). SIGNIFICANCE: Patients with epilepsy may experience seizure clusters lasting up to 24 hours, and little is known about the effectiveness of rescue therapies for that duration. The current labeling of the US Food and Drug Administration (FDA)-approved outpatient treatments for seizure clusters (rectal diazepam, intranasal midazolam, and diazepam nasal spray) allows for a second dose, if needed, for control. These findings support the safety profile of second doses, and the low use supports the effectiveness of diazepam nasal spray across 24 hours.


Subject(s)
Diazepam , Epilepsy, Generalized , Seizures , Administration, Intranasal , Anticonvulsants/administration & dosage , Anticonvulsants/adverse effects , Diazepam/administration & dosage , Diazepam/adverse effects , Epilepsy, Generalized/drug therapy , Hospitals , Humans , Nasal Sprays , Seizures/drug therapy
10.
Neurology ; 97(16): e1571-e1582, 2021 10 19.
Article in English | MEDLINE | ID: mdl-34521691

ABSTRACT

BACKGROUND AND OBJECTIVE: To test the hypothesis that a multicenter-validated computer deep learning algorithm detects MRI-negative focal cortical dysplasia (FCD). METHODS: We used clinically acquired 3-dimensional (3D) T1-weighted and 3D fluid-attenuated inversion recovery MRI of 148 patients (median age 23 years [range 2-55 years]; 47% female) with histologically verified FCD at 9 centers to train a deep convolutional neural network (CNN) classifier. Images were initially deemed MRI-negative in 51% of patients, in whom intracranial EEG determined the focus. For risk stratification, the CNN incorporated bayesian uncertainty estimation as a measure of confidence. To evaluate performance, detection maps were compared to expert FCD manual labels. Sensitivity was tested in an independent cohort of 23 cases with FCD (13 ± 10 years). Applying the algorithm to 42 healthy controls and 89 controls with temporal lobe epilepsy disease tested specificity. RESULTS: Overall sensitivity was 93% (137 of 148 FCD detected) using a leave-one-site-out cross-validation, with an average of 6 false positives per patient. Sensitivity in MRI-negative FCD was 85%. In 73% of patients, the FCD was among the clusters with the highest confidence; in half, it ranked the highest. Sensitivity in the independent cohort was 83% (19 of 23; average of 5 false positives per patient). Specificity was 89% in healthy and disease controls. DISCUSSION: This first multicenter-validated deep learning detection algorithm yields the highest sensitivity to date in MRI-negative FCD. By pairing predictions with risk stratification, this classifier may assist clinicians in adjusting hypotheses relative to other tests, increasing diagnostic confidence. Moreover, generalizability across age and MRI hardware makes this approach ideal for presurgical evaluation of MRI-negative epilepsy. CLASSIFICATION OF EVIDENCE: This study provides Class III evidence that deep learning on multimodal MRI accurately identifies FCD in patients with epilepsy initially diagnosed as MRI negative.


Subject(s)
Deep Learning , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Malformations of Cortical Development/diagnostic imaging , Neuroimaging/methods , Adolescent , Adult , Child , Child, Preschool , Female , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Young Adult
11.
Epilepsia ; 62(10): 2485-2495, 2021 10.
Article in English | MEDLINE | ID: mdl-34418086

ABSTRACT

OBJECTIVE: A Phase 3 open-label safety study (NCT02721069) evaluated long-term safety of diazepam nasal spray (Valtoco) in patients with epilepsy and frequent seizure clusters. METHODS: Patients were 6-65 years old with diagnosed epilepsy and seizure clusters despite stable antiseizure medications. The treatment period was 12 months, with study visits at Day 30 and every 60 days thereafter, after which patients could elect to continue. Doses were based on age and weight. Seizure and treatment information was recorded in diaries. Treatment-emergent adverse events (TEAEs), nasal irritation, and olfactory changes were recorded. RESULTS: Of 163 patients in the safety population, 117 (71.8%) completed the study. Duration of exposure was ≥12 months for 81.6% of patients. There was one death (sudden unexpected death in epilepsy) and one withdrawal owing to a TEAE (major depression), both considered unlikely to be related to treatment. Diazepam nasal spray was administered 4390 times for 3853 seizure clusters, with 485 clusters treated with a second dose within 24 h; 53.4% of patients had monthly average usage of one to two doses, 41.7% two to five doses, and 4.9% more than five doses. No serious TEAEs were considered to be treatment related. TEAEs possibly or probably related to treatment (n = 30) were most commonly nasal discomfort (6.1%); headache (2.5%); and dysgeusia, epistaxis, and somnolence (1.8% each). Only 13 patients (7.9%) showed nasal irritation, and there were no relevant olfactory changes. The safety profile of diazepam nasal spray was generally similar across subgroups based on age, monthly usage, concomitant benzodiazepine therapy, or seasonal allergy/rhinitis. SIGNIFICANCE: In this large open-label safety study, the safety profile of diazepam nasal spray was consistent with the established profile of rectal diazepam, and the high retention rate supports effectiveness in this population. A second dose was used in only 12.6% of seizure clusters.


Subject(s)
Epilepsy, Generalized , Epilepsy , Olfaction Disorders , Administration, Intranasal , Adolescent , Adult , Aged , Anticonvulsants/adverse effects , Brain Damage, Chronic , Child , Death, Sudden , Diazepam/adverse effects , Epilepsy/chemically induced , Epilepsy/drug therapy , Epilepsy, Generalized/drug therapy , Humans , Middle Aged , Nasal Sprays , Seizures/chemically induced , Seizures/drug therapy , Treatment Outcome , Young Adult
12.
Epilepsy Curr ; 21(1): 27-29, 2021.
Article in English | MEDLINE | ID: mdl-34025269
13.
Epilepsy Curr ; : 15357597211018219, 2021 May 16.
Article in English | MEDLINE | ID: mdl-33998298

ABSTRACT

Due to COVID-19 a live, in-person meeting was not possible for the American Epilepsy Society in 2020. An alternative, virtual event, the AES2020, was held instead. AES2020 was a great success with 4679 attendees from 70 countries. The educational content was outstanding and spanned the causes, treatments, and outcomes from epileptic encephalopathy to the iatrogenicity of epilepsy interventions to neurocognitive disabilities to the approach to neocortical epilepsies. New gene therapy approaches such as antisense oligonucleotide treatment for Dravet syndrome were introduced and neuromodulation devices were discussed. There were many other topics discussed in special interest groups and investigators' workshops. A highlight was having a Nobel prize winner speak about memory processing. Human intracranial electrophysiology contributes insights into memory processing and complements animal work. In a special COVID symposium, the impact of COVID on patients with epilepsy was reviewed. Telehealth has been expanded rapidly and may be well suited for some parts of epilepsy care. In summary, the epilepsy community was alive and engaged despite being limited to a virtual platform.

14.
Epilepsy Behav ; 120: 107983, 2021 07.
Article in English | MEDLINE | ID: mdl-33957437

ABSTRACT

OBJECTIVE: Tolerance is a known consideration for maintenance use of benzodiazepines and other antiseizure drugs; however, clinical experience suggests that tolerance may not be anticipated with long-term intermittent use of benzodiazepines as rescue therapy. Diazepam nasal spray (Valtoco®) is a proprietary intranasal formulation approved for the acute treatment of intermittent, stereotypic episodes of frequent seizure activity (ie, seizure clusters, acute repetitive seizures) in patients with epilepsy aged ≥6 years. Reported here are exploratory analyses investigating whether there was evidence of development of tolerance in an interim analysis of a long-term, phase 3, open-label safety study of diazepam nasal spray. METHODS: Patients and care partners were trained to administer 5, 10, 15, or 20 mg of diazepam nasal spray (age- and weight-based dosing), with a second dose administered 4-12 hours later if needed. A series of analyses were performed to assess evidence of tolerance using 2 equal, adjacent time periods and data for each patient to compare the proportion of events for which second doses of diazepam nasal spray (as a proxy for effectiveness) were administered in period 1 compared with period 2. RESULTS: A total of 175 patients were enrolled at interim cutoff, and 158 were treated with diazepam nasal spray for 3370 seizure-cluster events. For 73.4% of patients, duration of exposure to diazepam nasal spray was ≥12 months. A total of 191 analyses were conducted; the proportion of analyses in which second doses in period 2 were lower than in period 1 was 72.8%. Only 5 analyses showed nominally statistically significant changes (P < 0.05); this is fewer than expected by chance, and these differences were not directionally consistent. There was no safety signal with continued use. CONCLUSIONS: These analyses found no statistical evidence of tolerance with the use of diazepam nasal spray over time based on use of a second dose in an initial period of the study compared with a subsequent period for each patient. These results are in agreement with prior studies of benzodiazepine rescue therapy.


Subject(s)
Diazepam , Epilepsy , Nasal Sprays , Administration, Intranasal , Diazepam/therapeutic use , Epilepsy/drug therapy , Humans , Seizures/drug therapy , Treatment Outcome
15.
Epilepsy Behav ; 121(Pt A): 108013, 2021 08.
Article in English | MEDLINE | ID: mdl-34022621

ABSTRACT

BACKGROUND: Ideal rescue treatments for acute treatment of seizure clusters should be easy to administer, so it is important to assess user perceptions of these treatments. Diazepam nasal spray is designed to have a rapid, noninvasive, and socially acceptable route of administration. Patient and caregiver (including care partner) responses to surveys from a phase 3 safety study of diazepam nasal spray are reported. METHODS: The study enrolled patients aged 6-65 years with seizure clusters. Surveys distributed to patients and caregivers at study end, completion, or discontinuation collected data on comfort using diazepam nasal spray outside the home, timing of administration and return to their usual selves, and comfort of use compared with rectal diazepam. Safety was assessed. RESULTS: Of 175 patients enrolled at the October 31, 2019, interim cutoff, 158 received diazepam nasal spray. Sixty-seven (42.4%) patients and 84 (53.2%) caregivers responded to the surveys (including 35 matched pairs). Most patients (78.8%, 52/66) responded that they were very comfortable doing activities outside the home with diazepam nasal spray available; 59.4% of patients returned to their usual selves within an hour of administration. Twenty-seven (40.3%) of these patients reported self-administration, 48% doing so at the first sign of a seizure. Administration of diazepam nasal spray was rated extremely or very easy by 93.8% of caregivers. Safety profile was consistent with diazepam rectal gel; no patient discontinued owing to treatment-emergent adverse events. Nasal discomfort was typically mild and transient. Among patients who had used diazepam rectal gel, most were not at all comfortable using it outside the home (86.7%) or at home (64.5%) compared with diazepam nasal spray, whereas caregivers reported that diazepam rectal gel was not at all easy to use compared with diazepam nasal spray. CONCLUSIONS: This survey from the phase 3 safety study of diazepam nasal spray shows that patients and caregivers were satisfied with, and more comfortable using, diazepam nasal spray than rectal diazepam in public. NCT02721069.


Subject(s)
Caregivers , Nasal Sprays , Administration, Intranasal , Diazepam/therapeutic use , Humans , Seizures/drug therapy
16.
Epilepsia ; 62(6): 1442-1450, 2021 06.
Article in English | MEDLINE | ID: mdl-33942315

ABSTRACT

OBJECTIVE: Diazepam nasal spray (Valtoco), indicated for acute treatment of frequent seizure activity (seizure clusters) in patients with epilepsy ≥6 years of age, is designed to be a rapid, noninvasive, socially acceptable route of administration. This interim analysis evaluated the safety profile of diazepam nasal spray in patients with and without concomitant use of benzodiazepines, with use of a second dose for a seizure cluster as a proxy for effectiveness. METHODS: A long-term, phase 3, open-label safety study enrolled patients with epilepsy who had seizures despite a stable antiseizure medication regimen. RESULTS: Among 175 patients enrolled by October 31, 2019, a total of 158 were treated with diazepam nasal spray (aged 6-65 years; 53.8% female). Of those, 119 (75.3%) received concomitant benzodiazepines (60, chronic; 59, intermittent); 39 (24.7%) did not. Use of a second dose was similar in patients using chronic concomitant benzodiazepines (second dose in 11.1% [144/1299]) and those with no concomitant benzodiazepines (second dose in 10.3% [41/398]). Treatment emergent adverse events (TEAEs) occurred for 80.0% with chronic use of concomitant benzodiazepines and 61.5% without. Cardiorespiratory depression was not reported, and no serious TEAEs were treatment related. Study retention was high: 83.3% in the chronic benzodiazepine group and 76.9% in the no-benzodiazepine group. Findings were similar in a sub-analysis of patients who were (n = 44) or were not (n = 75) taking clobazam. SIGNIFICANCE: This analysis of patients from a long-term study shows a similar safety profile of diazepam nasal spray in patients with and without concomitant benzodiazepines, and consistent with the established profile for diazepam. Use of a single dose of diazepam nasal spray and high study retention rates suggest the effectiveness of diazepam nasal spray in patients irrespective of chronic daily benzodiazepine use. Results were similar in the clobazam sub-analysis. These results support the safety and effectiveness of diazepam nasal spray in patients with concomitant benzodiazepine use.


Subject(s)
Anticonvulsants/administration & dosage , Anticonvulsants/therapeutic use , Benzodiazepines/therapeutic use , Diazepam/administration & dosage , Diazepam/therapeutic use , Epilepsy/drug therapy , Adolescent , Adult , Aged , Anticonvulsants/adverse effects , Benzodiazepines/adverse effects , Child, Preschool , Clobazam/therapeutic use , Diazepam/adverse effects , Drug Therapy, Combination , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Nasal Sprays , Seizures/drug therapy , Treatment Outcome , Young Adult
17.
Clin Neurophysiol ; 132(4): 977-983, 2021 04.
Article in English | MEDLINE | ID: mdl-33652270

ABSTRACT

OBJECTIVE: Postictal generalized electroencephalographic suppression (PGES) has been defined as electroencephalographic (EEG) activity of less than 10 microvolts following a generalized seizure. PGES is associated with an increased risk of sudden unexplained death in epilepsy, as well as treatment efficacy of electroconvulsive therapy (ECT). We investigated the impact of anesthetic on PGES expression and temporal characteristics. METHODS: We recorded postictal EEG in 50 ECT sessions in 11 patients with treatment resistant depression (ClinicalTrials.gov NCT02761330). For each participant, repeated sessions included either ketamine or etomidate general anesthesia during ECT. An automated algorithm was employed to detect PGES within 5 minutes after seizure termination. RESULTS: PGES was detected in 31/50 recordings, with intermittent epochs recurring up to five minutes after seizure termination. PGES total duration was greater following ketamine than etomidate anesthesia (p = 0.04). PGES expression declined loglinearly as a function of time (r = -0.89, p < 10-4). EEG amplitude during PGES did not vary linearly with time. CONCLUSIONS: PGES can occur intermittently for several minutes following seizure termination. Anesthetic effects should be considered when correlating PGES duration to clinical outcomes. SIGNIFICANCE: Prolonged EEG monitoring several minutes following seizure termination may be necessary to fully evaluate the presence and total duration of PGES.


Subject(s)
Anesthesia/methods , Bipolar Disorder/therapy , Brain/physiopathology , Depressive Disorder, Treatment-Resistant/therapy , Electroconvulsive Therapy , Seizures/physiopathology , Adult , Bipolar Disorder/physiopathology , Depressive Disorder, Treatment-Resistant/physiopathology , Electroencephalography , Humans
18.
AJR Am J Roentgenol ; 216(3): 759-768, 2021 03.
Article in English | MEDLINE | ID: mdl-33474983

ABSTRACT

OBJECTIVE. The purpose of this article is to summarize the role of molecular imaging of the brain by use of SPECT, FDG PET, and non-FDG PET radiotracers in epilepsy. CONCLUSION. Quantitative image analysis with PET and SPECT has increased the diagnostic utility of these modalities in localizing epileptogenic onset zones. A multi-modal platform approach integrating the functional imaging of PET and SPECT with the morphologic information from MRI in presurgical evaluation of epilepsy can greatly improve outcomes.


Subject(s)
Brain/diagnostic imaging , Epilepsy/diagnostic imaging , Positron-Emission Tomography , Tomography, Emission-Computed, Single-Photon , Adolescent , Adult , Child , Child, Preschool , Cysteine/analogs & derivatives , Cysteine/pharmacokinetics , Female , Fluorodeoxyglucose F18/pharmacokinetics , Humans , Male , Middle Aged , Organotechnetium Compounds/pharmacokinetics , Oximes/pharmacokinetics , Radiopharmaceuticals/pharmacokinetics
19.
Clin Neurophysiol ; 131(12): 2817-2825, 2020 12.
Article in English | MEDLINE | ID: mdl-33137572

ABSTRACT

OBJECTIVE: Postictal generalized electroencephalographic suppression (PGES) is a pattern of low-voltage scalp electroencephalographic (EEG) activity following termination of generalized seizures. PGES has been associated with both sudden unexplained death in patients with epilepsy and therapeutic efficacy of electroconvulsive therapy (ECT). Automated detection of PGES epochs may aid in reliable quantification of this phenomenon. METHODS: We developed a voltage-based algorithm for detecting PGES. This algorithm applies existing criteria to simulate expert epileptologist readings. Validation relied on postictal EEG recording from patients undergoing ECT (NCT02761330), assessing concordance among the algorithm and four clinical epileptologists. RESULTS: We observed low-to-moderate concordance among epileptologist ratings of PGES. Despite this, the algorithm displayed high discriminability in comparison to individual epileptologists (C-statistic range: 0.86-0.92). The algorithm displayed high discrimination (C-statistic: 0.91) and substantial peak agreement (Cohen's Kappa: 0.65) in comparison to a consensus of clinical ratings. Interrater agreement between the algorithm and individual epileptologists was on par with that among expert epileptologists. CONCLUSIONS: An automated voltage-based algorithm can be used to detect PGES following ECT, with discriminability nearing that of experts. SIGNIFICANCE: Algorithmic detection may support clinical readings of PGES and improve precision when correlating this marker with clinical outcomes following generalized seizures.


Subject(s)
Algorithms , Electroencephalography/standards , Epilepsy/epidemiology , Epilepsy/physiopathology , Sudden Unexpected Death in Epilepsy/epidemiology , Electroencephalography/methods , Epilepsy/diagnosis , Humans , Reproducibility of Results , Sudden Unexpected Death in Epilepsy/prevention & control
20.
Epilepsia ; 61(3): 455-464, 2020 03.
Article in English | MEDLINE | ID: mdl-32065672

ABSTRACT

OBJECTIVE: The study assesses the bioavailability of diazepam after intranasal administration (diazepam nasal spray) in healthy volunteers. Comparative agents were diazepam rectal gel, which served as the regulatory reference product; and oral diazepam, a product with decades of clinical use. Tolerability of diazepam nasal spray was also assessed. METHODS: This was a phase 1, open-label, randomized, single-dose, three-treatment, three-period, six-sequence crossover study in 48 healthy adult subjects that consisted of a screening period, a baseline period, and an open-label treatment period. Interperiod intervals were at least 28 days. RESULTS: Forty-eight healthy volunteer subjects were enrolled, two of whom discontinued before receiving study medication. For all routes of administration, the onset of diazepam absorption was rapid, with measurable concentrations of drug present by the first sample time point. The tmax (time to reach maximum plasma concentration) was similar for diazepam nasal spray and diazepam rectal gel, both of which were slower than oral diazepam in fasted individuals. Variability (as defined by % coefficient of variation of geometric mean) in peak plasma concentration and area under the curve0-∞ was lowest with oral diazepam, followed by diazepam nasal spray, with diazepam rectal gel showing the greatest variability. Overall, 131 treatment-emergent adverse events (TEAEs) were considered mild (42 subjects, 91.3%), four TEAEs were considered moderate (four subjects, 8.3%), and no TEAEs were considered severe. The most commonly reported TEAE was somnolence at 56.5% (26/46) during diazepam nasal spray treatment, 89.1% (41/46) with the rectal diazepam gel treatment, and 82.6% (38/46) with oral diazepam treatment. No nasal irritation was observed for the majority of the subjects at any time point after administration, with no score higher than 2 ("minor bleeding that stops within 1 minute"). SIGNIFICANCE: Diazepam nasal spray shows predicable pharmacokinetics and represents a potential novel therapeutic approach to control bouts of increased seizure activity (cluster seizures, acute repetitive seizures).


Subject(s)
Diazepam/administration & dosage , Diazepam/pharmacokinetics , Administration, Intranasal , Administration, Oral , Administration, Rectal , Adolescent , Adult , Biological Availability , Female , Gels , Healthy Volunteers , Humans , Male , Middle Aged , Nasal Sprays , Sleepiness , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...