Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Polymers (Basel) ; 15(17)2023 Aug 27.
Article in English | MEDLINE | ID: mdl-37688185

ABSTRACT

Recent developments in urological implants have focused on preventive strategies to mitigate encrustation and biofilm formation. Parylene, a conformal, pinhole-free polymer coating, has gained attention due to its high biocompatibility and chemical resistance, excellent barrier properties, and low friction coefficient. This study aims to evaluate the effectiveness of parylene C in comparison to a parylene VT4 grade coating in preventing encrustation on a urinary bladder pressure MEMS sensor system. Additionally, silicon oxide (SiOx) applied as a finish coating was investigated for further improvements. An in vitro encrustation system mimicking natural urine flow was used to quantify the formation of urinary stones. These stones were subsequently analyzed using Fourier transform infrared spectrometry (FTIR). Encrustation results were then discussed in relation to coating surface chemical properties. Parylene C and VT4 grades demonstrated a very low encrustation mass, making them attractive options for encrustation prevention. The best performance was achieved after the addition of a hydrophilic SiOx finish coating on parylene VT4 grade. Parylene-based encapsulation proved to be an outstanding solution to prevent encrustation for urological implants.

2.
Arch Microbiol ; 205(7): 272, 2023 Jun 30.
Article in English | MEDLINE | ID: mdl-37391548

ABSTRACT

In the COVID-19 pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), face masks have become a very important safety measure against the main route of transmission of the virus: droplets and aerosols. Concerns that masks contaminated with SARS-CoV-2 infectious particles could be a risk for self-contamination have emerged early in the pandemic as well as solutions to mitigate this risk. The coating of masks with sodium chloride, an antiviral and non-hazardous to health chemical, could be an option for reusable masks. To assess the antiviral properties of salt coatings deposited onto common fabrics by spraying and dipping, the present study established an in vitro bioassay using three-dimensional airway epithelial cell cultures and SARS-CoV-2 virus. Virus particles were given directly on salt-coated material, collected, and added to the cell cultures. Infectious virus particles were measured by plaque forming unit assay and in parallel viral genome copies were quantified over time. Relative to noncoated material, the sodium chloride coating significantly reduced virus replication, confirming the effectiveness of the method to prevent fomite contamination with SARS-CoV-2. In addition, the lung epithelia bioassay proved to be suitable for future evaluation of novel antiviral coatings.


Subject(s)
COVID-19 , Sodium Chloride , Humans , Sodium Chloride/pharmacology , SARS-CoV-2 , Pandemics , COVID-19/prevention & control , Antiviral Agents/pharmacology
3.
Polymers (Basel) ; 15(11)2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37299355

ABSTRACT

While water vapor transmission rate (WVTR) measurement is standardly used to assess material permeability, a system able to quantify liquid water transmission rate (WTR) measurement is highly desirable for implantable thin film barrier coatings. Indeed, since implantable devices are in contact or immersed in body fluids, liquid WTR was carried out to obtain a more realistic measurement of the barrier performance. Parylene is a well-established polymer which is often the material of choice for biomedical encapsulation applications due to its flexibility, biocompatibility, and attractive barrier properties. Four grades of parylene coatings were tested with a newly developed permeation measurement system based on a quadrupole mass spectrometer (QMS) detection method. Successful measurements of gas and water vapor and the water transmission rates of thin parylene films were performed and validated, comparing the results with a standardized method. In addition, the WTR results allowed for the extraction of an acceleration transmission rate factor from the vapor-to-liquid water measurement mode, which varies from 4 to 4.8 between WVTR and WTR. With a WTR of 72.5 µm g m-2 day-1, parylene C displayed the most effective barrier performance.

4.
Sci Rep ; 12(1): 17041, 2022 10 11.
Article in English | MEDLINE | ID: mdl-36220878

ABSTRACT

During the coronavirus disease (COVID-19) pandemic, wearing face masks in public spaces became mandatory in most countries. The risk of self-contamination when handling face masks, which was one of the earliest concerns, can be mitigated by adding antiviral coatings to the masks. In the present study, we evaluated the antiviral effectiveness of sodium chloride deposited on a fabric suitable for the manufacturing of reusable cloth masks using techniques adapted to the home environment. We tested eight coating conditions, involving both spraying and dipping methods and three salt dilutions. Influenza A H3N2 virus particles were incubated directly on the salt-coated materials, collected, and added to human 3D airway epithelial cultures. Live virus replication in the epithelia was quantified over time in collected apical washes. Relative to the non-coated material, salt deposits at or above 4.3 mg/cm2 markedly reduced viral replication. However, even for larger quantities of salt, the effectiveness of the coating remained dependent on the crystal size and distribution, which in turn depended on the coating technique. These findings confirm the suitability of salt coating as antiviral protection on cloth masks, but also emphasize that particular attention should be paid to the coating protocol when developing consumer solutions.


Subject(s)
COVID-19 , SARS-CoV-2 , Antiviral Agents/pharmacology , COVID-19/prevention & control , Humans , In Vitro Techniques , Influenza A Virus, H3N2 Subtype , Masks , Sodium Chloride/pharmacology
5.
Polymers (Basel) ; 14(17)2022 Sep 04.
Article in English | MEDLINE | ID: mdl-36080750

ABSTRACT

Biocompatible polymer films demonstrating excellent thermal stability are highly desirable for high-temperature (>250 °C) applications, especially in the bioelectronic encapsulation domain. Parylene, as an organic thin film, is a well-established polymer material exhibiting excellent barrier properties and is often the material of choice for biomedical applications. This work investigated the thermal impact on the bulk properties of four types of parylene films: parylene N, C, VT4, and AF4. The films, deposited using the standard Gorham process, were analyzed at varying annealing temperatures from room temperature up to 450 °C. Thermal properties were identified by differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) methods, while X-ray diffraction (XRD) analysis showed the effect of high-temperature exposure on the structural properties. In addition to thermal and structural analysis, the barrier properties were measured through the helium transmission rate (HTR) and the water vapor transmission rate (WVTR). Fluorinated parylene films were confirmed to be exceptional materials for high-temperature applications. Parylene AF4 film, 25um thick, demonstrated excellent barrier performance after 300 °C exposure, with an HTR and a WVTR of 12.18 × 103 cm3 (STP) m−2 day−1 atm−1 and 6.6 g m−2 day−1, respectively.

6.
Biomed Microdevices ; 12(4): 607-18, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20229178

ABSTRACT

An implantable transducer for monitoring the flow of Cerebrospinal fluid (CSF) for the treatment of hydrocephalus has been developed which is based on measuring the heat dissipation of a local thermal source. The transducer uses passive telemetry at 13.56 MHz for power supply and read out of the measured flow rate. The in vitro performance of the transducer has been characterized using artificial Cerebrospinal Fluid (CSF) with increased protein concentration and artificial CSF with 10% fresh blood. After fresh blood was added to the artificial CSF a reduction of flow rate has been observed in case that the sensitive surface of the flow sensor is close to the sedimented erythrocytes. An increase of flow rate has been observed in case that the sensitive surface is in contact with the remaining plasma/artificial CSF mix above the sediment which can be explained by an asymmetric flow profile caused by the sedimentation of erythrocytes having increased viscosity compared to artificial CSF. After removal of blood from artificial CSF, no drift could be observed in the transducer measurement which could be associated to a deposition of proteins at the sensitive surface walls of the packaged flow transducer. The flow sensor specification requirement of +-10% for a flow range between 2 ml/h and 40 ml/h. could be confirmed at test conditions of 37 degrees C.


Subject(s)
Hydrocephalus/cerebrospinal fluid , Prostheses and Implants , Transducers , Calibration , Calorimetry , Cerebrospinal Fluid Proteins/metabolism , Cerebrospinal Fluid Shunts , Humans , Hydrocephalus/metabolism , Hydrocephalus/physiopathology , Hydrocephalus/surgery , Kinetics , Telemetry
SELECTION OF CITATIONS
SEARCH DETAIL
...