Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Anesthesiology ; 130(1): 119-130, 2019 01.
Article in English | MEDLINE | ID: mdl-30277932

ABSTRACT

BACKGROUND: Positive end-expiratory pressure is usually considered protective against ventilation-induced lung injury by reducing atelectrauma and improving lung homogeneity. However, positive end-expiratory pressure, together with tidal volume, gas flow, and respiratory rate, contributes to the mechanical power required to ventilate the lung. This study aimed at investigating the effects of increasing mechanical power by selectively modifying its positive end-expiratory pressure component. METHODS: Thirty-six healthy piglets (23.3 ± 2.3 kg) were ventilated prone for 50 h at 30 breaths/min and with a tidal volume equal to functional residual capacity. Positive end-expiratory pressure levels (0, 4, 7, 11, 14, and 18 cm H2O) were applied to six groups of six animals. Respiratory, gas exchange, and hemodynamic variables were recorded every 6 h. Lung weight and wet-to-dry ratio were measured, and histologic samples were collected. RESULTS: Lung mechanical power was similar at 0 (8.8 ± 3.8 J/min), 4 (8.9 ± 4.4 J/min), and 7 (9.6 ± 4.3 J/min) cm H2O positive end-expiratory pressure, and it linearly increased thereafter from 15.5 ± 3.6 J/min (positive end-expiratory pressure, 11 cm H2O) to 18.7 ± 6 J/min (positive end-expiratory pressure, 14 cm H2O) and 22 ± 6.1 J/min (positive end-expiratory pressure, 18 cm H2O). Lung elastances, vascular congestion, atelectasis, inflammation, and septal rupture decreased from zero end-expiratory pressure to 4 to 7 cm H2O (P < 0.0001) and increased progressively at higher positive end-expiratory pressure. At these higher positive end-expiratory pressure levels, striking hemodynamic impairment and death manifested (mortality 0% at positive end-expiratory pressure 0 to 11 cm H2O, 33% at 14 cm H2O, and 50% at 18 cm H2O positive end-expiratory pressure). From zero end-expiratory pressure to 18 cm H2O, mean pulmonary arterial pressure (from 19.7 ± 5.3 to 32.2 ± 9.2 mmHg), fluid administration (from 537 ± 403 to 2043 ± 930 ml), and noradrenaline infusion (0.04 ± 0.09 to 0.34 ± 0.31 µg · kg(-1) · min(-1)) progressively increased (P < 0.0001). Lung weight and lung wet-to-dry ratios were not significantly different across the groups. The lung mechanical power level that best discriminated between more versus less severe damage was 13 ± 1 J/min. CONCLUSIONS: Less than 7 cm H2O positive end-expiratory pressure reduced atelectrauma encountered at zero end-expiratory pressure. Above a defined power threshold, sustained positive end-expiratory pressure contributed to potentially lethal lung damage and hemodynamic impairment.


Subject(s)
Lung/physiopathology , Positive-Pressure Respiration/adverse effects , Positive-Pressure Respiration/methods , Ventilator-Induced Lung Injury/prevention & control , Animals , Disease Models, Animal , Swine
2.
Intensive Care Med Exp ; 5(1): 46, 2017 Oct 13.
Article in English | MEDLINE | ID: mdl-29030751

ABSTRACT

BACKGROUND: Severe hypoperfusion can cause lung damage. We studied the effects of regional perfusion block in normal lungs and in the lungs that had been conditioned by lavage with 500 ml saline and high V T (20 ml kg-1) ventilation. METHODS: Nineteen pigs (61.2 ± 2.5 kg) were randomized to five groups: controls (n = 3), the right lower lobe block alone (n = 3), lavage and high V T (n = 4), lung lavage, and high V T plus perfusion block of the right (n = 5) or left (n = 4) lower lobe. Gas exchange, respiratory mechanics, and hemodynamics were measured hourly. After an 8-h observation period, CT scans were obtained at 0 and 15 cmH2O airway pressure. RESULTS: Perfusion block did not damage healthy lungs. In conditioned lungs, the left perfusion block caused more edema in the contralateral lung (777 ± 62 g right lung vs 484 ± 204 g left; p < 0.05) than the right perfusion block did (581 ± 103 g right lung vs 484 ± 204 g left; p n.s.). The gas/tissue ratio, however, was similar (0.5 ± 0.3 and 0.8 ± 0.5; p n.s.). The lobes with perfusion block were not affected (gas/tissue ratio right 1.6 ± 0.9; left 1.7 ± 0.5, respectively). Pulmonary artery pressure, PaO2/FiO2, dead space, and lung mechanics were more markedly affected in animals with left perfusion block, while the gas/tissue ratios were similar in the non-occluded lobes. CONCLUSIONS: The right and left perfusion blocks caused the same "intensity" of edema in conditioned lungs. The total amount of edema in the two lungs differed because of differences in lung size. If capillary permeability is altered, increased blood flow may induce or increase edema.

SELECTION OF CITATIONS
SEARCH DETAIL
...