Circulation ; 149(17): 1328-1338, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38465592

ABSTRACT

BACKGROUND: Diabetes may be associated with differential outcomes in patients undergoing left main coronary revascularization with percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). The aim of this study was to investigate outcomes in patients with left main disease with and without diabetes randomized to PCI versus CABG. METHODS: Individual patient data were pooled from 4 trials (SYNTAX [Synergy Between PCI With Taxus and Cardiac Surgery], PRECOMBAT [Premier of Randomized Comparison of Bypass Surgery Versus Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease], NOBLE [Nordic-Baltic-British Left Main Revascularisation Study], and EXCEL [Evaluation of XIENCE Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization]) that randomized patients with left main disease to PCI or CABG. Patients were considered suitable for either approach. Patients were categorized by diabetes status. Kaplan-Meier event rates, Cox model hazard ratios, and interactions were assessed. RESULTS: Among 4393 patients, 1104 (25.1%) had diabetes. Patients with diabetes experienced higher rates of 5-year death (158/1104 [Kaplan-Meier rate, 14.7%] versus 297/3289 [9.3%]; P<0.001), spontaneous myocardial infarction (MI; 67/1104 [6.7%] versus 114/3289 [3.7%]; P<0.001), and repeat revascularization (189/1104 [18.5%] versus 410/3289 [13.2%]; P<0.001). Rates of all-cause mortality did not differ after PCI versus CABG in those with (84/563 [15.3%] versus 74/541 [14.1%]; hazard ratio, 1.11 [95% CI, 0.82-1.52]) or without (155/1634 [9.7%] versus 142/1655 [8.9%]; hazard ratio, 1.08 [95% CI, 0.86-1.36; PintHR=0.87) diabetes. Rates of stroke within 1 year were lower with PCI versus CABG in the entire population, with no heterogeneity based on diabetes status (PintHR=0.51). The 5-year rates of spontaneous MI and repeat coronary revascularization were higher after PCI regardless of diabetes status (spontaneous MI: 45/563 [8.9%] versus 22/541 [4.4%] in diabetes and 82/1634 [5.3%] versus 32/1655 [2.1%] in no diabetes, PintHR=0.47; repeat revascularization: 127/563 [24.5%] versus 62/541 [12.4%] in diabetes and 254/1634 [16.3%] versus 156/1655 [10.1%] in no diabetes, PintHR=0.18). For spontaneous MI and repeat revascularization, there were greater absolute risk differences beyond 1 year in patients with diabetes (4.9% and 9.9%) compared with those without (2.1% and 4.3%; PintARD=0.047 and 0.016). CONCLUSIONS: In patients with left main disease considered equally suitable for PCI or CABG and with largely low to intermediate SYNTAX scores, diabetes was associated with higher rates of death and cardiovascular events through 5 years. Compared with CABG, PCI resulted in no difference in the risk of death and a lower risk of early stroke regardless of diabetes status, and a higher risk of spontaneous MI and repeat coronary revascularization, with larger late absolute excess risks in patients with diabetes. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT01205776, NCT0146651, NCT00422968, and NCT00114972.

2.
Lancet ; 403(10429): 824-837, 2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38401549

ABSTRACT

BACKGROUND: Previous meta-analyses have shown reduced risks of composite adverse events with intravascular imaging-guided percutaneous coronary intervention (PCI) compared with angiography guidance alone. However, these studies have been insufficiently powered to show whether all-cause death or all myocardial infarction are reduced with intravascular imaging guidance, and most previous intravascular imaging studies were done with intravascular ultrasound rather than optical coherence tomography (OCT), a newer imaging modality. We aimed to assess the comparative performance of intravascular imaging-guided PCI and angiography-guided PCI with drug-eluting stents. METHODS: For this systematic review and updated meta-analysis, we searched the MEDLINE, Embase, and Cochrane databases from inception to Aug 30, 2023, for studies that randomly assigned patients undergoing PCI with drug-eluting stents either to intravascular ultrasound or OCT, or both, or to angiography alone to guide the intervention. The searches were done and study-level data were extracted independently by two investigators. The primary endpoint was target lesion failure, defined as the composite of cardiac death, target vessel-myocardial infarction (TV-MI), or target lesion revascularisation, assessed in patients randomly assigned to intravascular imaging guidance (intravascular ultrasound or OCT) versus angiography guidance. We did a standard frequentist meta-analysis to generate direct data, and a network meta-analysis to generate indirect data and overall treatment effects. Outcomes were expressed as relative risks (RRs) with 95% CIs at the longest reported follow-up duration. This study was registered with the international prospective register of systematic reviews (PROSPERO, number CRD42023455662). FINDINGS: 22 trials were identified in which 15 964 patients were randomised and followed for a weighted mean duration of 24·7 months (longest duration of follow-up in each study ranging from 6 to 60 months). Compared with angiography-guided PCI, intravascular imaging-guided PCI resulted in a decreased risk of target lesion failure (RR 0·71 [95% CI 0·63-0·80]; p<0·0001), driven by reductions in the risks of cardiac death (RR 0·55 [95% CI 0·41-0·75]; p=0·0001), TV-MI (RR 0·82 [95% CI 0·68-0·98]; p=0·030), and target lesion revascularisation (RR 0·72 [95% CI 0·60-0·86]; p=0·0002). Intravascular imaging guidance also reduced the risks of stent thrombosis (RR 0·52 [95% CI 0·34-0·81]; p=0·0036), all myocardial infarction (RR 0·83 [95% CI 0·71-0·99]; p=0·033), and all-cause death (RR 0·75 [95% CI 0·60-0·93]; p=0·0091). Outcomes were similar for OCT-guided and intravascular ultrasound-guided PCI. INTERPRETATION: Compared with angiography guidance, intravascular imaging guidance of coronary stent implantation with OCT or intravascular ultrasound enhances both the safety and effectiveness of PCI, reducing the risks of death, myocardial infarction, repeat revascularisation, and stent thrombosis. FUNDING: Abbott.


Subject(s)
Drug-Eluting Stents , Erythema Multiforme , Myocardial Infarction , Percutaneous Coronary Intervention , Thrombosis , Humans , Angiography , Network Meta-Analysis , Randomized Controlled Trials as Topic
4.
N Engl J Med ; 389(16): 1477-1487, 2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37634149

ABSTRACT

BACKGROUND: Imaging-guided percutaneous coronary intervention (PCI) is associated with better clinical outcomes than angiography-guided PCI. Whether routine optical coherence tomography (OCT) guidance in PCI of lesions involving coronary-artery branch points (bifurcations) improves clinical outcomes as compared with angiographic guidance is uncertain. METHODS: We conducted a multicenter, randomized, open-label trial at 38 centers in Europe. Patients with a clinical indication for PCI and a complex bifurcation lesion identified by means of coronary angiography were randomly assigned in a 1:1 ratio to OCT-guided PCI or angiography-guided PCI. The primary end point was a composite of major adverse cardiac events (MACE), defined as death from a cardiac cause, target-lesion myocardial infarction, or ischemia-driven target-lesion revascularization at a median follow-up of 2 years. RESULTS: We assigned 1201 patients to OCT-guided PCI (600 patients) or angiography-guided PCI (601 patients). A total of 111 patients (18.5%) in the OCT-guided PCI group and 116 (19.3%) in the angiography-guided PCI group had a bifurcation lesion involving the left main coronary artery. At 2 years, a primary end-point event had occurred in 59 patients (10.1%) in the OCT-guided PCI group and in 83 patients (14.1%) in the angiography-guided PCI group (hazard ratio, 0.70; 95% confidence interval, 0.50 to 0.98; P = 0.035). Procedure-related complications occurred in 41 patients (6.8%) in the OCT-guided PCI group and 34 patients (5.7%) in the angiography-guided PCI group. CONCLUSIONS: Among patients with complex coronary-artery bifurcation lesions, OCT-guided PCI was associated with a lower incidence of MACE at 2 years than angiography-guided PCI. (Funded by Abbott Vascular and others; OCTOBER ClinicalTrials.gov number, NCT03171311.).


Subject(s)
Coronary Angiography , Coronary Artery Disease , Percutaneous Coronary Intervention , Tomography, Optical Coherence , Humans , Coronary Angiography/adverse effects , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Tomography, Optical Coherence/adverse effects , Tomography, Optical Coherence/methods , Treatment Outcome , Europe
5.
EuroIntervention ; 19(6): 464-481, 2023 08 21.
Article in English | MEDLINE | ID: mdl-37171503

ABSTRACT

The clinical value of fractional flow reserve and non-hyperaemic pressure ratios are well established in determining an indication for percutaneous coronary intervention (PCI) in patients with coronary artery disease (CAD). In addition, over the last 5 years we have witnessed a shift towards the use of physiology to enhance procedural planning, assess post-PCI functional results, and guide PCI optimisation. In this regard, clinical studies have reported compelling data supporting the use of longitudinal vessel analysis, obtained with pressure guidewire pullbacks, to better understand how obstructive CAD contributes to myocardial ischaemia, to establish the likelihood of functionally successful PCI, to identify the presence and location of residual flow-limiting stenoses and to predict long-term outcomes. The introduction of new functional coronary angiography tools, which merge angiographic information with fluid dynamic equations to deliver information equivalent to intracoronary pressure measurements, are now available and potentially also applicable to these endeavours. Furthermore, the ability of longitudinal vessel analysis to predict the functional results of stenting has played an integral role in the evolving field of simulated PCI. Nevertheless, it is important to have an awareness of the value and challenges of physiology-guided PCI in specific clinical and anatomical contexts. The main aim of this European Association of Percutaneous Cardiovascular Interventions clinical consensus statement is to offer up-to-date evidence and expert opinion on the use of applied coronary physiology for procedural PCI planning, disease pattern recognition and post-PCI optimisation.


Subject(s)
Cardiology , Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Humans , Treatment Outcome , Coronary Artery Disease/surgery , Coronary Angiography/methods
6.
JAMA Cardiol ; 8(7): 631-639, 2023 07 01.
Article in English | MEDLINE | ID: mdl-37256598

ABSTRACT

Importance: Patients with left main coronary artery disease presenting with an acute coronary syndrome (ACS) represent a high-risk and understudied subgroup of patients with atherosclerosis. Objective: To assess clinical outcomes after PCI vs CABG in patients with left main disease with vs without ACS. Design, Setting, and Participants: Data were pooled from 4 trials comparing PCI with drug-eluting stents vs CABG in patients with left main disease who were considered equally suitable candidates for either strategy (SYNTAX, PRECOMBAT, NOBLE, and EXCEL). Patients were categorized as presenting with or without ACS. Kaplan-Meier event rates through 5 years and Cox model hazard ratios were generated, and interactions were tested. Patients were enrolled in the individual trials from 2004 through 2015. Individual patient data from the trials were pooled and reconciled from 2020 to 2021, and the analyses pertaining to the ACS subgroup were performed from March 2022 through February 2023. Main Outcomes and Measures: The primary outcome was death through 5 years. Secondary outcomes included cardiovascular death, spontaneous myocardial infarction (MI), procedural MI, stroke, and repeat revascularization. Results: Among 4394 patients (median [IQR] age, 66 [59-73] years; 3371 [76.7%] male and 1022 [23.3%] female) randomized to receive PCI or CABG, 1466 (33%) had ACS. Patients with ACS were more likely to have diabetes, prior MI, left ventricular ejection fraction less than 50%, and higher SYNTAX scores. At 30 days, patients with ACS had higher all-cause death (hazard ratio [HR], 3.40; 95% CI, 1.81-6.37; P < .001) and cardiovascular death (HR, 3.21; 95% CI, 1.69-6.08; P < .001) compared with those without ACS. Patients with ACS also had higher rates of spontaneous MI (HR, 1.70; 95% CI, 1.25-2.31; P < .001) through 5 years. The rates of all-cause mortality through 5 years with PCI vs CABG were 10.9% vs 11.5% (HR, 0.93; 95% CI, 0.68-1.27) in patients with ACS and 11.3% vs 9.6% (HR, 1.19; 95% CI, 0.95-1.50) in patients without ACS (P = .22 for interaction). The risk of early stroke was lower with PCI vs CABG (ACS: HR, 0.39; 95% CI, 0.12-1.25; no ACS: HR, 0.35; 95% CI, 0.16-0.75), whereas the 5-year risks of spontaneous MI and repeat revascularization were higher with PCI vs CABG (spontaneous MI: ACS: HR, 1.74; 95% CI, 1.09-2.77; no ACS: HR, 3.03; 95% CI, 1.94-4.72; repeat revascularization: ACS: HR, 1.57; 95% CI, 1.19-2.09; no ACS: HR, 1.90; 95% CI, 1.54-2.33), regardless of ACS status. Conclusion and Relevance: Among largely stable patients undergoing left main revascularization and with predominantly low to intermediate coronary anatomical complexity, those with ACS had higher rates of early death. Nonetheless, rates of all-cause mortality through 5 years were similar with PCI vs CABG in this high-risk subgroup. The relative advantages and disadvantages of PCI vs CABG in terms of early stroke and long-term spontaneous MI and repeat revascularization were consistent regardless of ACS status. Trial Registration: ClinicalTrials.gov Identifiers: NCT00114972, NCT00422968, NCT01496651, NCT01205776.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Bypass , Coronary Artery Disease , Percutaneous Coronary Intervention , Humans , Male , Female , Aged , Randomized Controlled Trials as Topic , Acute Coronary Syndrome/surgery , Atherosclerosis , Middle Aged , Stroke , Coronary Artery Disease/surgery
7.
Catheter Cardiovasc Interv ; 101(4): 787-797, 2023 03.
Article in English | MEDLINE | ID: mdl-36740229

ABSTRACT

AIMS: Early healing after drug-eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin strut everolimus-eluting Synergy DES (Boston Scientific) or the biolimus-eluting Biomatix Neoflex DES (Biosensors). METHODS AND RESULTS: A total of 160 patients with the chronic or acute coronary syndrome were randomized 1:1 to Synergy or Biomatrix DES. Optical coherence tomography (OCT) was performed at baseline and at either 1- or 3-month follow-up. The primary endpoint was a coronary stent healing index (CSHI), a weighted index of strut coverage, neointimal hyperplasia, malapposition, and extrastent lumen. A total of 133 cases had OCT follow-up and 119 qualified for matched OCT analysis. The median CSHI score did neither differ significantly between the groups at 1 month: Synergy 8.0 (interquartile range [IQR]: 3.0; 14.0) versus Biomatrix 8.5 (IQR: 4.0; 15.0) (p = 0.47) nor at 3 months: Synergy 6.5 (IQR: 2.0; 13.0) versus Biomatrix 6.0 (IQR: 4.0; 11.0) (p = 0.83). Strut coverage was 84.6% (IQR: 72.0; 97.9) for Synergy versus 77.6% (IQR: 70.1; 90.3) for Biomatrix (p = 0.15) at 1 month and 90.3% (IQR 79.0; 98.8) (Synergy) versus 83.9% (IQR: 77.5; 92.6) (Biomatrix) (p = 0.068) at 3 months. Pooled 1- and 3-month coverage was 88.6% (IQR: 74.4; 98.4) for Synergy compared with 80.7% (IQR: 73.2; 90.8) for Biomatrix (p = 0.02). CONCLUSIONS: The early healing response after treatment with the Synergy or Biomatrix DES did not differ significantly as determined by a healing index. The Synergy DES showed overall better early stent strut coverage.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Everolimus , Coronary Artery Disease/therapy , Polymers , Absorbable Implants , Treatment Outcome , Prosthesis Design , Tomography, Optical Coherence
8.
EuroIntervention ; 19(10): e807-e831, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-35583108

ABSTRACT

The Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods. Considering the complexity of bifurcation lesions and their evaluation, detailed instructions and technical aspects for site and core laboratory analysis of bifurcation lesions are also reported. The recommendations included within this consensus will facilitate pooled analyses and the effective comparison of data in the future, improving the clinical relevance of trials in bifurcation lesions, and the quality of care in this subset of patients.


Subject(s)
Coronary Artery Disease , Heart Valve Prosthesis Implantation , Humans , United States , Heart , Heart Valve Prosthesis Implantation/methods , Europe , Asia , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Treatment Outcome , Coronary Angiography
9.
J Am Coll Cardiol ; 80(1): 63-88, 2022 07 05.
Article in English | MEDLINE | ID: mdl-35597684

ABSTRACT

The Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods. Considering the complexity of bifurcation lesions and their evaluation, detailed instructions and technical aspects for site and core laboratory analysis of bifurcation lesions are also reported. The recommendations included within this consensus will facilitate pooled analyses and the effective comparison of data in the future, improving the clinical relevance of trials in bifurcation lesions, and the quality of care in this subset of patients.


Subject(s)
Coronary Artery Disease , Heart Valve Prosthesis Implantation , Asia , Cardiac Catheterization/methods , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Artery Disease/therapy , Europe , Heart , Heart Valve Prosthesis Implantation/methods , Humans , Treatment Outcome , United States/epidemiology
10.
BMC Cardiovasc Disord ; 22(1): 68, 2022 02 23.
Article in English | MEDLINE | ID: mdl-35196986

ABSTRACT

BACKGROUND: Complications related to femoral artery access for coronary angiography (CAG) is a safety concern. Vascular closure devices (VCDs) have been developed to reduce the rate of complications after femoral artery access. We compared the safety and efficacy of the MynxGrip VCD versus manual compression (MC) after femoral access CAG in a randomized controlled trial. METHODS: The study was a randomized, single center, non-blinded, two-arm non-inferiority trial. The study was stopped prematurely because of low inclusion rate. RESULTS: We randomized 869 patients to closure with the MynxGrip VCD or MC and 865 entered analyses. The incidence of the primary endpoint of major adverse vascular events (MAVE) after 30 days was 1.2% in the MynxGrip group and 0% in the MC group (p = 0.06). The median time to hemostasis was 4 [3:5] minutes and 10 [7:11] minutes in the MynxGrip group and MC group, respectively (p < 0.0001). The corresponding median times to mobilization was 73 [65:87] minutes and 76 [70:88] minutes (p = 0.01). CONCLUSIONS: MAVE was rare after closure of femoral arterial access by both the MynxGrip VCD and MC. We found a numerical difference in favour of MC but this did not reach statistical significance. Time to hemostasis was shorter in the MynxGrip group when compared to the MC group. TRIAL REGISTRATION: The study was approved by the local medical ethics committee and registered at clinicaltrials.org (ClinicalTrials identifier: NCT02237430 11/09/2014).


Subject(s)
Vascular Closure Devices , Coronary Angiography/adverse effects , Femoral Artery/diagnostic imaging , Hemostatic Techniques/adverse effects , Humans , Punctures , Time Factors , Treatment Outcome , Vascular Closure Devices/adverse effects
11.
Catheter Cardiovasc Interv ; 99(1): 68-73, 2022 01 01.
Article in English | MEDLINE | ID: mdl-33533535

ABSTRACT

OBJECTIVES: This study aims to evaluate the diagnostic performance of quantitative flow ratio (QFR) pre transcatheter aortic valve implantation (TAVI) in patients with aortic valve stenosis (AS) and coronary artery disease (CAD). Post-TAVI fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) was used as reference. BACKGROUND: CAD is prevalent in patients with AS, but the hemodynamics of AS confounds evaluation using pressure wire-based assessments. QFR might be less sensitive to the presence of AS thereby allowing for CAD evaluation before aortic valve replacement. Further, QFR does not require the use of pressure wire and therefore has the potential for reducing costs and complications related to insertion of a coronary pressure wire. METHODS: The diagnostic performance of QFR in coronary angiograms from 28 patients undergoing TAVI was evaluated. In all patients, both FFR and iFR were measured pre- and immediately post-TAVI while QFR was measured pre-TAVI. RESULTS: Using post-TAVI FFR and iFR as reference the diagnostic accuracy of pre-TAVI QFR were 83% (95%CI; 68-97) and 52% (95%CI; 30-74) p = .008, respectively. CONCLUSIONS: Pre-TAVI QFR showed a good diagnostic performance using post-TAVI FFR as reference. QFR could become a wire-free, safe, and quick way of evaluating CAD in patients with severe AS undergoing TAVI.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Vessels , Humans , Predictive Value of Tests , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
Catheter Cardiovasc Interv ; 99(4): 1075-1083, 2022 03.
Article in English | MEDLINE | ID: mdl-34967094

ABSTRACT

OBJECTIVES: To evaluate the feasibility, safety, and healing response of a magnesium-based bioresorbable scaffold (BRS) in the treatment of simple bifurcation lesions using the single stent provisional technique. BACKGROUND: BRS may hold potential advantages in the treatment of coronary bifurcation lesions, however low radial strength and expansion capacity has been an issue with polymer-based scaffolds. The magnesium BRS may prove suitable for bifurcation treatment as its mechanical properties are closer to those of permanent metallic drug-eluting stents. METHODS: The study was a proof-of-concept study with planned inclusion of 20 patients with stable angina pectoris and a bifurcation lesion involving a large side branch (SB) > 2.5 mm with less than 50% diameter stenosis. Procedure and healing response were evaluated by optical coherence tomography (OCT). The main endpoints were a composite clinical safety endpoint and an OCT healing index at 1 month (range: 0-98). RESULTS: Eleven patients were included in the study. The study was prematurely terminated due to scaffold fractures and embolization of scaffold fragments in three cases requiring bailout stenting with drug-eluting stents. One patient underwent bypass surgery at 3 months due to stenosis proximal to the study segment. All SB were patent for 1 month. One-month OCT evaluation showed strut coverage of 96.9% and no malapposition. Scaffold fractures and uncovered jailing struts resulted in a less favorable mean OCT healing index score of 10.4 ± 9.0. CONCLUSIONS: Implanting a magnesium scaffold by the provisional technique in nontrue bifurcation lesions was associated with scaffold fracture, embolization of scaffold fragments, and a high need for bailout stenting.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Absorbable Implants , Constriction, Pathologic , Coronary Angiography/methods , Coronary Artery Disease/surgery , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Humans , Magnesium , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Tissue Scaffolds , Tomography, Optical Coherence/methods , Treatment Outcome
13.
Lancet ; 398(10318): 2247-2257, 2021 12 18.
Article in English | MEDLINE | ID: mdl-34793745

ABSTRACT

BACKGROUND: The optimal revascularisation strategy for patients with left main coronary artery disease is uncertain. We therefore aimed to evaluate long-term outcomes for patients treated with percutaneous coronary intervention (PCI) with drug-eluting stents versus coronary artery bypass grafting (CABG). METHODS: In this individual patient data meta-analysis, we searched MEDLINE, Embase, and the Cochrane database using the search terms "left main", "percutaneous coronary intervention" or "stent", and "coronary artery bypass graft*" to identify randomised controlled trials (RCTs) published in English between database inception and Aug 31, 2021, comparing PCI with drug-eluting stents with CABG in patients with left main coronary artery disease that had at least 5 years of patient follow-up for all-cause mortality. Two authors (MSS and BAB) identified studies meeting the criteria. The primary endpoint was 5-year all-cause mortality. Secondary endpoints were cardiovascular death, spontaneous myocardial infarction, procedural myocardial infarction, stroke, and repeat revascularisation. We used a one-stage approach; event rates were calculated by use of the Kaplan-Meier method and treatment group comparisons were made by use of a Cox frailty model, with trial as a random effect. In Bayesian analyses, the probabilities of absolute risk differences in the primary endpoint between PCI and CABG being more than 0·0%, and at least 1·0%, 2·5%, or 5·0%, were calculated. FINDINGS: Our literature search yielded 1599 results, of which four RCTs-SYNTAX, PRECOMBAT, NOBLE, and EXCEL-meeting our inclusion criteria were included in our meta-analysis. 4394 patients, with a median SYNTAX score of 25·0 (IQR 18·0-31·0), were randomly assigned to PCI (n=2197) or CABG (n=2197). The Kaplan-Meier estimate of 5-year all-cause death was 11·2% (95% CI 9·9-12·6) with PCI and 10·2% (9·0-11·6) with CABG (hazard ratio 1·10, 95% CI 0·91-1·32; p=0·33), resulting in a non-statistically significant absolute risk difference of 0·9% (95% CI -0·9 to 2·8). In Bayesian analyses, there was an 85·7% probability that death at 5 years was greater with PCI than with CABG; this difference was more likely than not less than 1·0% (<0·2% per year). The numerical difference in mortality was comprised more of non-cardiovascular than cardiovascular death. Spontaneous myocardial infarction (6·2%, 95% CI 5·2-7·3 vs 2·6%, 2·0-3·4; hazard ratio [HR] 2·35, 95% CI 1·71-3·23; p<0·0001) and repeat revascularisation (18·3%, 16·7-20·0 vs 10·7%, 9·4-12·1; HR 1·78, 1·51-2·10; p<0·0001) were more common with PCI than with CABG. Differences in procedural myocardial infarction between strategies depended on the definition used. Overall, there was no difference in the risk of stroke between PCI (2·7%, 2·0-3·5) and CABG (3·1%, 2·4-3·9; HR 0·84, 0·59-1·21; p=0·36), but the risk was lower with PCI in the first year after randomisation (HR 0·37, 0·19-0·69). INTERPRETATION: Among patients with left main coronary artery disease and, largely, low or intermediate coronary anatomical complexity, there was no statistically significant difference in 5-year all-cause death between PCI and CABG, although a Bayesian approach suggested a difference probably exists (more likely than not <0·2% per year) favouring CABG. There were trade-offs in terms of the risk of myocardial infarction, stroke, and revascularisation. A heart team approach to communicate expected outcome differences might be useful to assist patients in reaching a treatment decision. FUNDING: No external funding.


Subject(s)
Coronary Artery Bypass/methods , Coronary Artery Disease/mortality , Coronary Artery Disease/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , Humans , Randomized Controlled Trials as Topic
14.
Catheter Cardiovasc Interv ; 96(1): 31-39, 2020 07.
Article in English | MEDLINE | ID: mdl-32087046

ABSTRACT

OBJECTIVES: In a coronary bifurcation bench model, to determine the effects of side branch (SB) wire crossing position and balloon position on the stent scaffolding after the final proximal optimization technique (POT). BACKGROUND: POT performed as a final step after SB dilatation or kissing balloon inflation (KBI) has been widely advocated despite limited evidence. METHODS: Thirty-one stent implantations in bifurcation phantoms were performed using a one-stent provisional technique with (KBI) (n = 13), with POT-side-POT technique (n = 12) or with the two-stent culotte technique (n = 6). SB wiring was performed through either a proximal or a distal stent cell and confirmed by optical coherence tomography. Final POT was performed with the balloon positioned either across or proximal to the SB takeoff. The area of the opened stent cell in front of the SB was assessed by 3D reconstructed microcomputation tomography scans performed before and after Final POT. RESULTS: In cases with metallic carina, final POT across the SB takeoff caused SB rejailing. Regardless of stent technique and wire position, a Final POT across the SB takeoff reduced the SB cell opening area by 43% [32%;58%] (n = 15). The largest reduction (54-70%) was found after the POT-side-POT technique in procedures with a proximal wiring. Final POT performed proximal to the SB takeoff caused limited or no SB cell opening area reduction (4% [0.6%;6%] [n = 16]). CONCLUSION: Final POT with balloon positioned across the SB takeoff in a narrow angle bifurcation reduces largest stent cell area in front of the SB ostium and may cause SB rejailing in cases with metallic carina.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Vessels , Drug-Eluting Stents , Angioplasty, Balloon, Coronary/adverse effects , Coronary Vessels/diagnostic imaging , Humans , Materials Testing , Models, Anatomic , Models, Cardiovascular , Prosthesis Design
15.
JACC Cardiovasc Imaging ; 13(4): 994-1004, 2020 04.
Article in English | MEDLINE | ID: mdl-31422146

ABSTRACT

OBJECTIVES: This study was designed to compare head-to-head fractional flow reserve (FFR) derived from coronary computed tomography angiography (CTA) (FFRCT) and cardiac magnetic resonance (CMR) stress perfusion imaging for prediction of standard-of-care-guided coronary revascularization in patients with stable chest pain and obstructive coronary artery disease by coronary CTA. BACKGROUND: FFRCT is a novel modality for noninvasive functional testing. The clinical utility of FFRCT compared to CMR stress perfusion imaging in symptomatic patients with coronary artery disease is unknown. METHODS: Prospective study of patients (n = 110) with stable angina pectoris and 1 or more coronary stenosis ≥50% by coronary CTA. All patients underwent invasive coronary angiography. Revascularization was FFR-guided in stenoses ranging from 30% to 90%. FFRCT ≤0.80 in 1 or more coronary artery or a reversible perfusion defect (≥2 segments) by CMR categorized patients with ischemia. FFRCT and CMR were analyzed by core laboratories blinded for patient management. RESULTS: A total of 38 patients (35%) underwent revascularization. Per-patient diagnostic performance for identifying standard-of-care-guided revascularization, (95% confidence interval) yielded a sensitivity of 97% (86% to 100%) for FFRCT versus 47% (31% to 64%) for CMR, p < 0.001; corresponding specificity was 42% (30% to 54%) versus 88% (78% to 94%), p < 0.001; negative predictive value of 97% (91% to 100%) versus 76% (67% to 85%), p < 0.05; positive predictive value of 47% (36% to 58%) versus 67% (49% to 84%), p < 0.05; and accuracy of 61% (51% to 70%) versus 74% (64% to 82%), p > 0.05, respectively. CONCLUSIONS: In patients with stable chest pain referred to invasive coronary angiography based on coronary CTA, FFRCT and CMR yielded similar overall diagnostic accuracy. Sensitivity for prediction of revascularization was highest for FFRCT, whereas specificity was highest for CMR.


Subject(s)
Angina, Stable/diagnostic imaging , Computed Tomography Angiography , Coronary Angiography , Coronary Stenosis/diagnostic imaging , Fractional Flow Reserve, Myocardial , Magnetic Resonance Imaging , Multidetector Computed Tomography , Myocardial Perfusion Imaging , Aged , Angina, Stable/physiopathology , Angina, Stable/therapy , Coronary Artery Bypass , Coronary Stenosis/physiopathology , Coronary Stenosis/therapy , Denmark , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention , Predictive Value of Tests , Prospective Studies , Randomized Controlled Trials as Topic , Treatment Outcome
16.
Int J Cardiovasc Imaging ; 36(2): 241-249, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31667662

ABSTRACT

Heterogeneous neointimal response has been observed after implantation of all generations of coronary stents. Our aim was assessing local factors of shear stress (SS) and plaque characteristics in neointimal response after implantation of bioresorbable scaffolds (BRS) in bifurcations. Ten patients from the BIFSORB pilot study were analysed. Follow-up optical frequency domain imaging (OFDI) was performed at 1 month and 2 years. Coronary lumen and BRS structure were reconstructed by fusion of OFDI and angiography and were used for subsequent flow simulation. Plaque arc degree and SS were quantified using post-procedural OFDI data and were matched with follow-up OFDI using anatomical landmarks. Strut-level and segment-level analysis were performed for 1-month and 2-year follow-up respectively. A total of 444 struts (54 jailing struts) were included at 1-month follow-up. Time-average SS (TASS) was significantly lower for covered struts than for uncovered struts in non-bifurcation segments (TASS: 1.81 ± 1.87 vs. 3.88 ± 3.72 Pa, p < 0.001). The trend remained the same for jailing struts, although statistically insignificant (TASS: 10.85 ± 13.12 vs. 13.64 ± 14.48 Pa, p = 0.328). For 2-year follow-up, a total of 66 sub-regions were analysed. Neointimal hyperplasia area (NTA) was negatively correlated with TASS in core-segments (ρ = - 0.389, p = 0.037) and positively correlated with plaque arc degree in non-core segments (ρ = 0.387, p = 0.018). Slightly stronger correlations with NTA were observed when combining TASS and plaque arc degree in both core segments (ρ = - 0.412, p = 0.026) and non-core segments (ρ = - 0.395, p = 0.015). Hemodynamic microenvironment and baseline plaque characteristics may regulate neointimal response after BRS implantation in bifurcation. These findings underline the combined role of plaque characteristics and local hemodynamics in vessel healing after stent implantation.


Subject(s)
Absorbable Implants , Carotid Arteries/physiopathology , Coronary Artery Disease/therapy , Coronary Circulation , Hemodynamics , Neointima , Percutaneous Coronary Intervention/instrumentation , Plaque, Atherosclerotic , Aged , Carotid Arteries/diagnostic imaging , Carotid Arteries/pathology , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Coronary Artery Disease/physiopathology , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Pilot Projects , Prosthesis Design , Time Factors , Tomography, Optical Coherence
17.
Catheter Cardiovasc Interv ; 96(7): E674-E682, 2020 12.
Article in English | MEDLINE | ID: mdl-31710149

ABSTRACT

OBJECTIVES: To compare on the bench the physical and mechanical properties of Magmaris, a magnesium bioresorbable scaffold (BRS), with Absorb and DESolve polymeric BRS and a permanent metallic stent. BACKGROUND: Understanding the mechanical and physical properties of BRS is crucial for appropriate implantation and postdilatation. METHODS: Testing was performed in fluid at 37°C and in silicone bifurcation phantoms with a 30° angle between main branch (MB) and side branch. RESULTS: The 3.0-mm Magmaris BRS did not fracture after MB postdilatation up to 4.4 mm in contrast to the Absorb where the safe postdilatation diameter was 3.7 mm. For dilatation through stent cells, there were no Magmaris fractures with 3.0-mm noncompliant (NC) balloons inflated to nominal pressure. Mini-kissing balloon postdilatation with two 3.0-mm NC balloons up to 17 atm was without fracture except for an outlier. Longitudinal and radial strengths were similar for Magmaris and Absorb BRS. The crossing profile for the Magmaris was larger than other devices. Recoil 120 min after deployment was the greatest for Magmaris but 120 min after 3.5 mm postdilatation all devices had similar diameters. CONCLUSIONS: The Magmaris BRS was more resistant to strut fracture than Absorb. It had a larger crossing profile than other devices and similar radial and longitudinal strengths to Absorb. While recoil after deployment was greater with Magmaris, 120 min after 3.5 mm postdilatation all devices had similar diameters.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Drug-Eluting Stents , Magnesium , Angioplasty, Balloon, Coronary/adverse effects , Equipment Failure Analysis , Materials Testing , Prosthesis Design , Prosthesis Failure , Stress, Mechanical
18.
Lancet ; 395(10219): 191-199, 2020 01 18.
Article in English | MEDLINE | ID: mdl-31879028

ABSTRACT

BACKGROUND: Percutaneous coronary intervention (PCI) is increasingly used in revascularisation of patients with left main coronary artery disease in place of the standard treatment, coronary artery bypass grafting (CABG). The NOBLE trial aimed to evaluate whether PCI was non-inferior to CABG in the treatment of left main coronary artery disease and reported outcomes after a median follow-up of 3·1 years. We now report updated 5-year outcomes of the trial. METHODS: The prospective, randomised, open-label, non-inferiority NOBLE trial was done at 36 hospitals in nine northern European countries. Patients with left main coronary artery disease requiring revascularisation were enrolled and randomly assigned (1:1) to receive PCI or CABG. The primary endpoint was major adverse cardiac or cerebrovascular events (MACCE), a composite of all-cause mortality, non-procedural myocardial infarction, repeat revascularisation, and stroke. Non-inferiority of PCI to CABG was defined as the upper limit of the 95% CI of the hazard ratio (HR) not exceeding 1·35 after 275 MACCE had occurred. Secondary endpoints included all-cause mortality, non-procedural myocardial infarction, and repeat revascularisation. Outcomes were analysed in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, NCT01496651. FINDINGS: Between Dec 9, 2008, and Jan 21, 2015, 1201 patients were enrolled and allocated to PCI (n=598) or CABG (n=603), with 17 subsequently lost to early follow-up. 592 patients in each group were included in this analysis. At a median of 4·9 years of follow-up, the predefined number of events was reached for adequate power to assess the primary endpoint. Kaplan-Meier 5-year estimates of MACCE were 28% (165 events) for PCI and 19% (110 events) for CABG (HR 1·58 [95% CI 1·24-2·01]); the HR exceeded the limit for non-inferiority of PCI compared to CABG. CABG was found to be superior to PCI for the primary composite endpoint (p=0·0002). All-cause mortality was estimated in 9% after PCI versus 9% after CABG (HR 1·08 [95% CI 0·74-1·59]; p=0·68); non-procedural myocardial infarction was estimated in 8% after PCI versus 3% after CABG (HR 2·99 [95% CI 1·66-5·39]; p=0·0002); and repeat revascularisation was estimated in 17% after PCI versus 10% after CABG (HR 1·73 [95% CI 1·25-2·40]; p=0·0009). INTERPRETATION: In revascularisation of left main coronary artery disease, PCI was associated with an inferior clinical outcome at 5 years compared with CABG. Mortality was similar after the two procedures but patients treated with PCI had higher rates of non-procedural myocardial infarction and repeat revascularisation. FUNDING: Biosensors.


Subject(s)
Coronary Artery Bypass , Coronary Stenosis/surgery , Percutaneous Coronary Intervention , Aged , Cause of Death , Coronary Artery Bypass/adverse effects , Coronary Restenosis/surgery , Drug-Eluting Stents , Equivalence Trials as Topic , Graft Occlusion, Vascular , Humans , Middle Aged , Myocardial Infarction , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Postoperative Complications , Prospective Studies , Stroke , Treatment Outcome
19.
Cardiovasc Diagn Ther ; 9(5): 481-491, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31737519

ABSTRACT

BACKGROUND: Three-dimensional quantitative coronary angiography (3D-QCA) enables reconstruction of a coronary artery in 3D from two angiographic image projections. This study compared the diagnostic accuracy of 3D-QCA vs. 2-dimensional (2D) QCA in predicting physiologically significant coronary stenosis, using fractional flow reserve (FFR) as the reference standard. METHODS: All interrogated vessels in the FAVOR II China study and the FAVOR II Europe-Japan study were assessed by 2D-QCA and 3D-QCA according to standard operating procedures in core laboratories. QCA analysts were blinded to the corresponding FFR values. RESULTS: A total of 645 vessels from 576 patients with 3D-QCA, 2D-QCA, and FFR were analyzed. Using the conventional cut-off value of 50% for percent diameter stenosis (DS%), 3D-QCA was more accurate in predicting FFR ≤0.80 than 2D-QCA [accuracy 74.0% (95% CI: 69.9-77.7%) vs. 64.9% (95% CI: 61.3-68.7%), difference: 9.1%, P<0.001]. Sensitivity was higher by 3D-QCA compared with 2D-QCA [69.1% (95% CI: 63.0-75.1%) vs. 47.1% (95% CI: 40.5-53.6%), difference: 22.0%, P<0.001] and specificity was similar [76.5% (95% CI: 72.5-80.6%) vs. 74.4% (95% CI: 70.2-78.6%), difference: 2.1%, P=0.40]. Area under the receiver operating characteristic curve was significantly higher for 3D-QCA than for 2D-QCA [0.81 (95% CI: 0.77-0.84) vs. 0.66 (95% CI: 0.62-0.71), P<0.001]. CONCLUSIONS: 3D-QCA demonstrated better diagnostic performance in predicting physiologically significant coronary stenosis compared with 2D-QCA, when FFR was used as the reference standard.

20.
Eur Heart J ; 39(35): 3314-3321, 2018 09 14.
Article in English | MEDLINE | ID: mdl-30137305

ABSTRACT

Aims: Pressure-wire assessment of coronary stenosis is considered the invasive reference standard for detection of ischaemia-generating lesions. Recently, methods to estimate the fractional flow reserve (FFR) from conventional angiography without the use of a pressure wire have been developed, and were shown to have an excellent diagnostic accuracy. The present systematic review and meta-analysis aimed at determining the diagnostic performance of angiography-derived FFR for the diagnosis of haemodynamically significant coronary artery disease. Methods and results: A systematic review and meta-analysis of studies assessing the diagnostic performance of angiography-derived FFR systems were performed. The primary outcome of interest was pooled sensitivity and specificity. Thirteen studies comprising 1842 vessels were included in the final analysis. A Bayesian bivariate meta-analysis yielded a pooled sensitivity of 89% (95% credible interval 83-94%), specificity of 90% (95% credible interval 88-92%), positive likelihood ratio (+LR) of 9.3 (95% credible interval 7.3-11.7) and negative likelihood ratio (-LR) of 0.13 (95% credible interval 0.07-0.2). The summary area under the receiver-operating curve was 0.84 (95% credible interval 0.66-0.94). Meta-regression analysis did not find differences between the methods for pressure-drop calculation (computational fluid dynamics vs. mathematical formula), type of analysis (on-line vs. off-line) or software packages. Conclusion: The accuracy of angiography-derived FFR was good to detect haemodynamically significant lesions with pressure-wire measured FFR as a reference. Computational approaches and software packages did not influence the diagnostic accuracy of angiography-derived FFR. A diagnostic strategy trial with angiography-derived FFR evaluating clinical endpoints is warranted.


Subject(s)
Coronary Angiography/methods , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/physiopathology , Fractional Flow Reserve, Myocardial , Bayes Theorem , Humans , Sensitivity and Specificity
SELECTION OF CITATIONS