J Cardiovasc Magn Reson ; 22(1): 35, 2020 05 18.
Article in English | MEDLINE | ID: mdl-32418537

ABSTRACT

BACKGROUND: Cardiovascular magnetic resonance (CMR) studies in patients with implanted cardioverter/defibrillators (ICD) are increasingly required in daily clinical practice. However, the clinical experience regarding the feasibility as well as clinical value of CMR studies in patients with subcutaneous ICD (S-ICD) is still limited. Besides safety issues, image quality and analysis can be impaired primarily due the presence of image artefacts associated with the generator. METHODS: Twenty-three patients with an implanted S-ICD (EMBLEM, Boston Scientific, Marlborough, Massachusetts, USA; MR-conditional) with suspected cardiomyopathy and/or myocarditis underwent multi-parametric CMR imaging. Studies were performed on a 1.5 T CMR scanner after device interrogation and comprised standard a) balanced steady state free precession cine, b) T2 weighted-edema, c) velocity-encoded cine flow, d) myocardial perfusion, e) late-gadolinium-enhancement (LGE)-imaging and f) 3D-CMR angiography of the aorta. In case of substantial artefacts, alternative CMR techniques such as spoiled gradient-echo cine-sequences and wide-band inversion-recovery LGE (wb-LGE) sequences were applied. RESULTS: Successful CMR studies could be performed in all patients without any case of unexpected early termination or relevant technical complication other than permanent loss of the S-ICD system beeper volume in 52% of our patients. Assessment of cine-CMR images was predominantly impaired in the left ventricular (LV) anterior, lateral and inferior wall segments and a switch to spoiled gradient echo-based cine-CMR allowed an accurate assessment of cine-images in N = 17 (74%) patients with only limited artefacts. Hyperintensity artefacts in conventional LGE-images were predominantly observed in the LV anterior, lateral and inferior wall segments and image optimisation by use of the wb-LGE was helpful in 15 (65%) cases. Aortic flow measurements and 3D-CMR angiography were assessable in all patients Perfusion imaging artefacts precluded a meaningful assessment in at least one half of the patients. A benefit in clinical-decision making was documented in 17 (74%) patients in the present study. CONCLUSION: Safe 1.5 T CMR imaging was possible in all patients with an S-ICD, though the majority had permanent loss of the S-ICD beeper volume. Achieving good image quality may be challenging in some patients - particularly for perfusion imaging. Using spoiled gradient echo-based cine-sequences and wb-LGE sequences may help to reduce the extent of artefacts, thereby allowing accurate cardiac assessment. Thus, 1.5 T CMR studies should not be withhold in patients with S-ICD for safety concerns and/or fear of extensive imaging artefacts precluding successful image analysis.


Subject(s)
Cardiomyopathies/diagnostic imaging , Defibrillators, Implantable , Electric Countershock/instrumentation , Magnetic Resonance Imaging, Cine , Myocardial Perfusion Imaging/methods , Myocarditis/diagnostic imaging , Adult , Aged , Artifacts , Cardiomyopathies/physiopathology , Cardiomyopathies/therapy , Clinical Decision-Making , Coronary Circulation , Electric Countershock/adverse effects , Female , Humans , Magnetic Resonance Imaging, Cine/adverse effects , Male , Middle Aged , Myocardial Perfusion Imaging/adverse effects , Myocarditis/physiopathology , Myocarditis/therapy , Patient Safety , Predictive Value of Tests , Prognosis , Prosthesis Design , Prosthesis Failure , Reproducibility of Results , Risk Assessment , Risk Factors , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL