Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Article in English | MEDLINE | ID: mdl-38490250

ABSTRACT

OBJECTIVES: Our goal was to evaluate early and mid-term outcomes of physician-modified endografting for pararenal and thoraco-abdominal aortic aneurysms from 10 Japanese aortic centres. METHODS: From January 2012 to March 2022, a total of 121 consecutive adult patients who underwent physician-modified endografting for pararenal and thoraco-abdominal aortic aneurysms were enrolled. We analysed early and mid-term postoperative outcomes, including postoperative complications and mortality. RESULTS: The pararenal and thoraco-abdominal aortic aneurysm groups included 62 (51.2%) and 59 (48.8%) patients, respectively. The overall in-hospital mortality rate was 5.8% (n = 7), with mortality rates of 3.2% (n = 2) and 8.5% (n = 5) in pararenal and thoraco-abdominal aortic aneurysm groups, respectively (P = 0.225). Type IIIc endoleaks occurred postoperatively in 18 patients (14.9%), with a significantly higher incidence (P = 0.033) in the thoraco-abdominal aortic aneurysm group (22.0%, n = 13) than in the other group (8.1%, n = 5). Major adverse events occurred in 7 (11.3%) and 14 (23.7%) patients in pararenal and thoraco-abdominal aortic aneurysm groups (P = 0.074), respectively. The mean follow-up period was 24.2 months. At the 3-year mark, both groups differed significantly in freedom from all-cause mortality (83.3% and 54.1%, P = 0.004), target aneurysm-related mortality (96.8% and 82.7%, P = 0.013) and any reintervention (89.3% and 65.6%, P = 0.002). Univariate and multivariate regression analyses demonstrated that ruptures, thoraco-abdominal aortic aneurysms and postoperative type IIIc endoleaks were associated with an increased risk of all-cause mortality. CONCLUSIONS: The mid-term outcomes of physician-modified endografting for pararenal and thoraco-abdominal aortic aneurysms were clinically acceptable and comparable with those in other recently published studies. Notably, pararenal and thoraco-abdominal aortic aneurysms represent distinct pathological entities with different postoperative outcomes.

2.
Vasc Endovascular Surg ; 57(8): 937-940, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37306014

ABSTRACT

Endovascular stent-graft therapy is a commonly performed procedure for aortic lesions worldwide and complications unique to stent grafts, such as postoperative endoleaks, are well known. However, as this treatment modality becomes more popular, physicians should carefully monitor for other unexpected complications, which may not always be related to the graft. This study presents a case of leiomyosarcoma of the aorta that developed during follow-up for a type II endoleak (T2EL) after thoracic endovascular aortic repair. The presence of the T2EL hindered the diagnosis of the sarcoma at an early stage. These findings suggest that an apparent aneurysm that grows suddenly during follow-up after stent grafting should raise the index of suspicion for a neoplasm as well as an endoleak.


Subject(s)
Endoleak , Endovascular Aneurysm Repair , Leiomyosarcoma , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/surgery , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Endovascular Aneurysm Repair/adverse effects , Leiomyosarcoma/diagnostic imaging , Leiomyosarcoma/surgery , Leiomyosarcoma/complications , Postoperative Complications , Retrospective Studies , Stents/adverse effects , Treatment Outcome
3.
Cardiovasc Intervent Radiol ; 45(3): 290-297, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35088138

ABSTRACT

PURPOSE: To investigate the relationships between indications for thoracic endovascular aortic repair for acute/subacute complicated Stanford type B aortic dissection and clinical outcomes, and complications specific to thoracic endovascular aortic repair. MATERIAL AND METHODS: The J-predictive study retrospectively collected data of patients treated with thoracic endovascular aortic repair for complicated Stanford type B aortic dissection at 20 institutions from January 2012 to March 2017. From the database, those treated for acute/subacute complicated Stanford type B aortic dissection were extracted (n = 118; 96 men; average age, 66.1 years; standard deviation, ± 13) and classified into groups 1, 2, and 3 according to thoracic endovascular aortic repair indications (rupture, superior mesenteric artery malperfusion, and renal or lower extremity malperfusion, respectively). Primary and secondary measures were mortality (overall and aortic-related) and complications related to thoracic endovascular aortic repair, respectively. For each outcome, the risks of being in groups 1 and 2 were statistically compared with that of being in group 3 as a control using Fisher's exact test. RESULTS: Mortality rate (odds ratio, 5.22; 95% confidence interval [CI], 1.33-20.53) and prevalence of paraparesis/paraplegia (odds ratio, 30.46; confidence interval, 1.71-541.77) were higher in group 1 than in group 3. Compared to group 3, group 2 showed no statistically significant differences in mortality or complications related to thoracic endovascular aortic repair. CONCLUSIONS: Rupture as an indication for thoracic endovascular aortic repair for type B aortic dissection was more likely to result in worse mortality and high prevalence of spinal cord ischemia. LEVEL OF EVIDENCE: Level 4, Case series.


Subject(s)
Aortic Dissection , Endovascular Procedures , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Endovascular Procedures/adverse effects , Female , Humans , Japan/epidemiology , Male , Postoperative Complications/epidemiology , Retrospective Studies , Risk Factors , Treatment Outcome
4.
Ann Vasc Surg ; 78: 152-160, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34464725

ABSTRACT

BACKGROUND: Hybrid endovascular repair for thoracoabdominal aortic aneurysm (TAAA) is a less invasive alternative treatment than conventional open repair. However, disseminated intravascular coagulation (DIC) and hemorrhagic complications can occur postoperatively. We investigated risk factors for hemorrhagic complications after hybrid endovascular TAAA repair. METHODS: Sixty-one patients who underwent elective hybrid endovascular TAAA repair between 2007 and 2020 were included. Laboratory data before and after placing stent graft were collected, and DIC was diagnosed using a scoring system established by the Japanese Association for Acute Medicine. The length of the stent graft used to cover the aorta was defined as the aortic coverage length, which was measured using the first postoperative computed tomography image. Predictors of unexpected hemorrhagic complications were evaluated. RESULTS: Postoperative thrombocytopenia was observed in 57 (93%) patients, and their platelet count decreased significantly after stent graft placement (14.3 [9.5-18.0] vs. 8.2 [5.4-10.9] × 104/µL, P < 0.001). Fifteen (25%) and 45 patients (74%) were diagnosed with DIC before and after stent graft placement, respectively. Hemorrhagic complications were observed in 21 patients (34%). Multivariate logistic regression analysis revealed that aortic coverage length was an independent risk factor for hemorrhagic complications (odds ratio 1.441/50 mm increase; 95% confidence interval, 1.041-1.994, P = 0.027). The cutoff value for aortic coverage length obtained from the receiver operating characteristic curve (area under the curve = 0.72) was 304.4 mm (sensitivity 0.76, specificity 0.70). CONCLUSION: Aortic coverage length is a risk factor for hemorrhagic complications. Patients undergoing extensive aortic coverage greater than 304 mm should be closely monitored.


Subject(s)
Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis , Disseminated Intravascular Coagulation/etiology , Endovascular Procedures/adverse effects , Postoperative Hemorrhage/etiology , Aged , Aortic Aneurysm, Thoracic , Elective Surgical Procedures , Female , Humans , Male , Middle Aged , ROC Curve , Stents , Thrombocytopenia/etiology
5.
CVIR Endovasc ; 4(1): 77, 2021 Nov 02.
Article in English | MEDLINE | ID: mdl-34727271

ABSTRACT

OBJECTIVES: To clarify characteristic angiographic features and clinical efficacy of selective transarterial embolization (TAE) of retained placenta with abnormal vaginal bleeding. METHODS: The study cohort comprised 22 patients (mean age, 33.5 years; range, 22-24 years) who underwent selective TAE for retained placenta with abnormal bleeding between January 2018 and December 2020 at our institution. Angiographic images were reviewed by two certified radiologists with consensus. Medical records were reviewed to evaluate the efficacy of TAE. Angiographic features of retained placenta, technical success (disappearance of abnormal findings on angiography), complications, clinical outcomes (hemostatic effects and recurrent bleeding) were evaluated. RESULTS: Pelvic angiography showed a dilated vascular channel mimicking arteriovenous fistulas or an aneurysm contiguous with dilated uterine arteries in the mid-arterial-capillary phase in 20 patients; it showed contrast brush in the remaining two patients. TAE technical success was achieved in all patients. No major complications were observed in any patients. Fifteen patients were followed up with expectant management after TAE; all but one patient showed no re-bleeding during the follow-up period (mean follow-up interval, 3.4 months; range, 1-17 months). One patient showed minor rebleeding, which resolved spontaneously. Seven patients underwent scheduled hysteroscopic resection within 1 week after TAE, and no excessive bleeding was observed during or after the surgical procedure in all seven patients. CONCLUSIONS: The characteristic angiographic feature of retained placenta is "dilated vascular channel that mimic low flow AVM." TAE is a safe and effective treatment to manage retained placenta with abnormal bleeding.

6.
J Vasc Interv Radiol ; 32(4): 602-609.e1, 2021 04.
Article in English | MEDLINE | ID: mdl-33676799

ABSTRACT

PURPOSE: To evaluate the safety and effectiveness of hydrogel-coated coils for vessel occlusion in the body trunk. MATERIALS AND METHODS: A total of 77 patients with various peripheral vascular lesions, treatable by embolization with coils, were randomized (hydrogel group, n = 38; nonhydrogel group, n = 39). In the hydrogel group, embolization of the target vessel was conducted using 0.018-inch hydrogel-coated coils (AZUR 18; Terumo Medical Corporation, Tokyo, Japan) with or without bare platinum coils. The nonhydrogel group received both bare platinum coils and fibered coils without the use of hydrogel-coated coils. RESULTS: Complete target vessel occlusion was accomplished in 36 patients in the hydrogel group and 37 patients in the nonhydrogel group. No major adverse events were observed in either group. The median number of coils/vessel diameter and the median total coil length/vessel diameter were significantly larger in the nonhydrogel group than in the hydrogel group (P = .005 and P = .004, respectively). The median embolization length was significantly longer in the nonhydrogel group (31.95 mm) than in the hydrogel group (23.43 mm) (P = .002). If no expansion was assumed, the median packing density in the hydrogel group was 44.9%, which was similar to that in the nonhydrogel group (46.5%) (P = .79). With full expansion assumed, the median packing density in the hydrogel group was 125.7%. CONCLUSIONS: Hydrogel-coated coils can be safely used for peripheral vascular coil embolization, and hydrogel-coated and conventional coils in combination allow for a shorter embolization segment and shorter coil length.


Subject(s)
Coated Materials, Biocompatible , Embolization, Therapeutic/instrumentation , Vascular Diseases/therapy , Adult , Aged , Aged, 80 and over , Embolization, Therapeutic/adverse effects , Equipment Design , Female , Humans , Hydrogels , Japan , Male , Middle Aged , Prospective Studies , Single-Blind Method , Time Factors , Treatment Outcome , Vascular Diseases/diagnostic imaging , Vascular Diseases/physiopathology
7.
Jpn J Radiol ; 38(10): 968-972, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32488500

ABSTRACT

OBJECTIVE: To determine the ability of multidetector computed tomography (MPR-MDCT) to identify and classify the juxtapapillary duodenal diverticulum (JPDD), with ERCP findings as the gold standard. METHODS: We retrospectively reviewed all ERCP examinations (n: 455) performed between January 2010 to December 2018 and selected 105 patients with JPDD as the inclusion criteria. Of those, 28 patients were excluded because of advanced pancreatic carcinoma, incomplete MDCT examinations and biliary catheter insertion. Finally, MDCT examinations of 77 patients with JPDD were assessed for the presence and type of JPDD. RESULTS: MPR-MDCT was able to identify 71 (92.2%) JPDD in 77 cases with 88.9% accuracy, 83.3% sensitivity, and 91.6% specificity in classifying the type of JPDD. MPR-MDCT performed best in determining type 1 JPDD, with accuracy of 95.4% compared with type 2 (83.3%) and type 3 (87.8%). There was no significant difference between age, gender, incidence of biliary stones and pancreatitis between each type of JPDD. No correlation of sizes with types of JPDD was found. CONCLUSIONS: MPR-MDCT can accurately identify and classify JPDD. This information will be useful in determining the difficulty of ERCP.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde , Diverticulum/diagnostic imaging , Duodenal Diseases/diagnostic imaging , Multidetector Computed Tomography , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Sensitivity and Specificity
9.
Radiology ; 294(2): 455-463, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31821120

ABSTRACT

Background Management of abdominal branches associated with Stanford type B aortic dissection is controversial without definite criteria for therapy after thoracic endovascular aortic repair (TEVAR). This is in part due to lack of data on natural history related to branch vessels and their relationship with the dissection flap, true lumen, and false lumen. Purpose To investigate the natural history of abdominal branches after TEVAR for type B aortic dissection and the relationship between renal artery anatomy and renal volume as a surrogate measure of perfusion. Materials and Methods This study included patients who underwent TEVAR for complicated type B dissection from January 2012 to March 2017 at 20 centers. Abdominal aortic branches were classified with following features: patency, branch vessel origin, and presence of extension of the aortic dissection into a branch (pattern 1, supplied by the true lumen without branch dissection; pattern 2, supplied by the true lumen with branch dissection, etc). The branch artery patterns before TEVAR were compared with those of the last follow-up CT (mean interval, 19.7 months) for spontaneous healing. Patients with one kidney supplied by pattern 1 and the other kidney by a different pattern were identified, and kidney volumes over the course were compared by using a simple linear regression model. Results Two hundred nine patients (mean age ± standard deviation, 66 years ± 13; 165 men and 44 women; median follow-up, 18 months) were included. Four hundred fifty-nine abdominal branches at the last follow-up were evaluable. Spontaneous healing of the dissected branch occurred in 63% (64 of 102) of pattern 2 branches. Regarding the other patterns, 6.5% (six of 93) of branches achieved spontaneous healing. In 79 patients, renal volumes decreased in kidneys with pattern 2 branches with more than 50% stenosis and branches supplied by the aortic false lumen (patterns 3 and 4) compared with contralateral kidneys supplied by pattern 1 (pattern 2 vs pattern 1: -16% ± 16 vs 0.10% ± 11, P = .002; patterns 3 and 4 vs pattern 1: -13% ± 14 vs 8.5% ± 14, P = .004). Conclusion Spontaneous healing occurs more frequently in dissected branches arising from the true lumen than in other branch patterns. Renal artery branches supplied by the aortic false lumen or a persistently dissected artery with greater than 50% stenosis are associated with significantly greater kidney volume loss. © RSNA, 2019 Online supplemental material is available for this article.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm/surgery , Aortic Dissection/surgery , Endovascular Procedures/methods , Renal Artery Obstruction/complications , Renal Artery Obstruction/diagnostic imaging , Aged , Aortic Dissection/complications , Aortic Aneurysm/complications , Female , Humans , Japan , Kidney/diagnostic imaging , Kidney/pathology , Male , Renal Artery/diagnostic imaging , Renal Artery/pathology , Renal Artery Obstruction/pathology , Retrospective Studies , Tomography, X-Ray Computed/methods , Treatment Outcome
10.
Cardiovasc Intervent Radiol ; 42(10): 1510, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31321480

ABSTRACT

On page 1852, the first sentence of the second paragraph "In all PAVMs, the mean diameter of the feeding artery was 7.24 ± 0.015 mm, and the mean maximum diameter of the sac was 19.10 ± 0.585 mm" should be corrected to read as follows.

11.
Abdom Radiol (NY) ; 44(9): 3139-3147, 2019 09.
Article in English | MEDLINE | ID: mdl-31168723

ABSTRACT

PURPOSE: To elucidate the relationships between mural nodules (MNs) and invasive components in patients with invasive intraductal papillary mucinous neoplasm (IPMN) on the basis of thin-section contrast-enhanced multidetector CT (CE-MDCT) and pathologic findings. METHODS: This retrospective study included 28 patients with surgically confirmed invasive IPMN. Two radiologists independently evaluated the thin-section (1-mm section thickness, no overlap) triple-phase CE-MDCT images for MNs, invasive components, and the continuity between them using a five-point scale (confidence scores of 1-3 as negative, 4 and 5 as positive). Kappa statistic was used to evaluate interobserver agreement. The CE-MDCT findings were correlated with pathologic findings. RESULTS: Interobserver agreement was good or excellent. MNs consisting of tumor cells were recognized in 12 (42.9%) of 28 patients with no discrepancy between the two radiologists. Invasive components were detected in 85.7% and 82.1% in the pancreatic parenchymal phase for radiologist 1 and 2, respectively, and recognized as hypoattenuating areas. Pathologic continuities between MNs and invasive components were confirmed in five (41.7%) of 12 patients with MNs and these were detected on CE-MDCT. When combined seven patients without continuities between MNs and invasive components and 16 patients without MNs, the invasive components pathologically derived from non-nodular low-height papillary epithelium in 23 (82.1%) of 28 patients. CONCLUSIONS: The invasive components derived more often from low-height papillary epithelium without MN appearance on CE-MDCT than from MN. Careful attention should be paid to the existence of an invasive component even in the absence of an enhancing MN.


Subject(s)
Contrast Media , Image Enhancement/methods , Multidetector Computed Tomography/methods , Pancreatic Intraductal Neoplasms/diagnostic imaging , Pancreatic Intraductal Neoplasms/pathology , Aged , Aged, 80 and over , Diagnosis, Differential , Humans , Male , Middle Aged , Neoplasm Invasiveness , Pancreas/diagnostic imaging , Pancreas/pathology , Retrospective Studies
12.
Ann Vasc Surg ; 59: 36-47, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31009715

ABSTRACT

BACKGROUND: In situ fenestration of aortic stent grafts for treatment of aortic arch aneurysms is a new option for endovascular aortic arch repair. So far, only few reports have shown perioperative and short-term results of in situ fenestrations for aortic arch diseases. We present the multicenter experience with the aortic arch in situ fenestration technique documented in the AARCHIF registry for treatment of aortic arch aneurysms or localized type A aortic dissections and analyzed perioperative outcome and midterm follow-up. METHODS: Patients with aortic arch pathologies treated by aortic arch in situ fenestration with proximal stent graft landing in aortic arch Ishimura zones 0 and 1 were included in the registry. Stent-graft in situ fenestrations were created using needles or radiofrequency or laser catheters and completed by implantation of covered connecting stent grafts. Single in situ fenestrations for the left subclavian artery (LSA) were excluded. RESULTS: Between 06/2009 and 03/2017, twenty-five patients were treated by in situ stent-graft fenestrations for aortic arch pathologies at 9 institutions in 7 different countries, 3 of them as bailout procedures for stent-graft malplacement. In situ fenestrations were performed for the brachiocephalic trunk (n = 20), the left common carotid artery (n = 21) and the LSA (n = 9). Technical success for intended in situ fenestrations was 94.0% (47/50), with additional supraaortic bypass procedures performed in 14 patients. Perioperative mortality occurred in 1 (4.0%) patient, treated as a bailout procedure and 3 (12.0%) perioperative strokes were observed. One proximal aortic stent-graft nonalignment and 4 type III endoleaks, 2 early and 2 late, required reeintervention. During follow-up (1-118 months), the diameter of aortic arch aneurysms decreased from 61.5 ± 4.1 mm to 48.4 ± 3.2 mm (P = 0.02) and, so far, 6 patients died from diseases unrelated to their aortic arch pathologies with a mean survival time of 79.5 months and 3 endovascular reinterventions for distal aortic expansion were performed. Cerebrovascular event (n = 4) was the most relevant prognostic factor for mortality during midterm follow-up (P = 0.003). CONCLUSIONS: The aortic arch in situ fenestration technique for endovascular aortic arch repair seems to be valuable treatment option for selected patients, although initial consideration of other treatment options is mandatory. Data about long-term durability are required.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Adult , Aged , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Dissection/physiopathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Prosthesis Design , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
13.
Cardiovasc Intervent Radiol ; 41(12): 1849-1856, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30135976

ABSTRACT

PURPOSE: Reperfusion via pulmonary-to-pulmonary arterial anastomoses is known as one type of recurrence of pulmonary arteriovenous malformations (PAVMs) after embolization. It is important to occlude the fistulous portion beyond the origin of the last normal branch from feeding artery of PAVMs to prevent recurrence. In this study, we evaluate the origin of the last normal branch by CT as well as its visibility on pulmonary arteriography (PAG). MATERIALS AND METHODS: We reviewed forty patients with 77 PAVMs who underwent coil embolization between October 2007 and December 2017. All patients underwent MDCT before embolization. Axial and MPR CT lung images were reviewed with special interests in the origin of the last normal branch from feeding artery of PAVMs. The origin was classified into three portions, including sac, junction (portion just proximal to the sac) and proximal feeder (more than 5 mm proximal to the sac). We also evaluated whether PAG can depict the normal branches detected by MDCT. RESULTS: MDCT showed that the last normal branch originated from sac in 30 PAVMs (39.0%), junction in 39 (50.6%), and proximal feeder in 8 (10.4%).On selective PAG, the last normal branch could be visualized in 30 PAVMs (39.0%), although it could not be visualized due to high-flow shunt in the other 47 PAVMs. CONCLUSIONS: Selective PAG frequently fails to demonstrate the last normal branch from feeding artery of PAVMs, which often originates from the sac. Pretherapeutic evaluation of CT images of the last normal branch is important to prevent reperfusion of PAVMs. LEVEL OF EVIDENCE: Level 3, local non-random sample.


Subject(s)
Arterio-Arterial Fistula/diagnostic imaging , Pulmonary Artery/abnormalities , Pulmonary Artery/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Angiography/methods , Arterio-Arterial Fistula/therapy , Embolization, Therapeutic/methods , Female , Humans , Male , Middle Aged , Multidetector Computed Tomography/methods , Recurrence , Retrospective Studies , Treatment Outcome , Young Adult
14.
Abdom Radiol (NY) ; 43(12): 3374-3380, 2018 12.
Article in English | MEDLINE | ID: mdl-29796845

ABSTRACT

PURPOSE: To reveal the prevalence of small (≤ 20 mm) pancreatic ductal carcinomas with enhanced rims on triple-phase contrast-enhanced CT and correlate the CT images with the pathologic findings. MATERIALS AND METHODS: Between April 2005 and April 2016, 45 patients underwent preoperative triple-phase contrast-enhanced CT and were pathologically diagnosed with small pancreatic ductal carcinoma. CT images were independently reviewed by two radiologists. The attenuation values of the enhanced rims, internal areas of the tumors, and surrounding pancreatic parenchyma were compared using Mann-Whitney U test. These areas were also correlated with the pathologic findings. Tumor invasiveness was compared between the tumors with and without enhanced rims using Fisher's exact test. RESULTS: Enhanced rims were identified in 18 tumors (40%) by consensus between the two reviewers. The enhanced rims showed significantly higher mean attenuation values compared with the internal areas of the tumors (p < 0.001) and surrounding pancreatic parenchyma (p < 0.0086), and were most clearly visualized on equilibrium phase. The enhanced rims pathologically reflected the abundant fibrotic stroma with cancer cells in all tumors. There was no statistically significant difference in tumor invasiveness between the tumors with and without enhanced rims (anterior peripancreatic invasion, p = 0.137; posterior peripancreatic invasion, p = 0.758; portal vein invasion, p = 0.639; and lymph node metastases, p = 0.359). CONCLUSIONS: Enhanced rims were detected at a rate of 40% in small pancreatic ductal carcinomas and could be an important finding for diagnosis on CT images, but did not suggest a less aggressive nature.


Subject(s)
Carcinoma, Pancreatic Ductal/diagnostic imaging , Carcinoma, Pancreatic Ductal/pathology , Contrast Media , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Pancreas/diagnostic imaging , Pancreas/pathology , Retrospective Studies
15.
Interact Cardiovasc Thorac Surg ; 26(6): 951-956, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29415193

ABSTRACT

OBJECTIVES: The treatment of thoraco-abdominal aortic aneurysm continues to have a high mortality and paraplegia rate. In superaging societies, the methods of performing less invasive operations remain a major issue. We reviewed our 10-year experience in the treatment of thoraco-abdominal aortic aneurysm using a hybrid procedure of combined visceral reconstruction and thoracic endovascular aortic repair. METHODS: Sixty patients underwent a hybrid repair for the treatment of the thoraco-abdominal aortic aneurysm between 2007 and 2016. The mean age was 72.7 years. A true aneurysm was found in 43 (72%) patients and a chronic dissection in 17 (28%) patients. The standard operative procedure involved replacing the abdominal aorta with an artificial graft, and the visceral arteries were reconstructed using a quadrifurcated graft. Renovisceral debranching and stent grafting were performed as a 2-stage procedure. RESULTS: The hospital mortality rate was 5%. Two (3%) patients died due to an aneurysmal rupture in the hospital just after renovisceral debranching. The other 2 patients died due to an aneurysmal rupture in the long-term period after preventive renovisceral debranching. Two (3%) patients experienced spinal cord ischaemia after the stenting procedure. Four (7%) patients required additional treatment during the follow-up period. The overall survival was 75.9% at 2 years, 65.2% at 5 years and 43.5% at 8 years. The rates of freedom from aorta-related events were 92.9% at 2 years, 80.5% at 5 years and 72.5% at 8 years. CONCLUSIONS: The hybrid repair is considered to be a good option for elderly and high-risk patients. Further long-term follow-up is necessary to extend the indication in younger patients.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Age Factors , Aged , Aged, 80 and over , Aortic Aneurysm, Thoracic/mortality , Female , Hospital Mortality , Humans , Male , Middle Aged , Retrospective Studies , Stents , Time Factors , Treatment Outcome
17.
Abdom Radiol (NY) ; 42(10): 2410-2419, 2017 10.
Article in English | MEDLINE | ID: mdl-28444420

ABSTRACT

PURPOSE: We sought to evaluate visualization of periportal lymphatics and lymph nodes (lymphatic system) on Gd-EOB-DTPA-enhanced magnetic resonance (MR) images using a fat-suppressed T2-weighted sequence with 3-dimensional (3D) volume isotropic turbo spin echo acquisition (VISTA) at 3.0 T in normal subjects and patients with chronic hepatitis C. METHODS: MR imaging was performed in 254 subjects between June 2013 and May 2016. After applying inclusion and exclusion criteria, the final population was 31 normal subjects and 34 patients with chronic hepatitis C. Images were acquired after the hepatobiliary phase following intravenous administration of Gd-EOB-DTPA, which causes signal loss in the bile ducts, to facilitate the visualization of the periportal lymphatic system. Two radiologists assessed the visualization of the periportal lymphatic system in 31 normal subjects. The axial dimensions of the main periportal lymphatic system in normal subjects were measured and compared with those of 34 patients with chronic hepatitis C using the Mann-Whitney U-test, and their correlation with a hepatic fibrosis marker, the Fibrosis-4 (FIB-4), was assessed using Spearman's rank correlation test. RESULTS: The periportal lymphatic system was detected as high signal intensity areas surrounding the portal vein up to the third branches by each reader in all normal subjects. The axial dimensions of the main periportal lymphatic system in patients with chronic hepatitis C were significantly larger than those in normal subjects (p < 0.0001), and showed a significantly positive correlation with the FIB-4 score (ρ = 0.73, p < 0.001). CONCLUSIONS: Fat-suppressed T2-weighted MR imaging with 3D-VISTA acquired after the hepatobiliary phase on Gd-EOB-DTPA-enhanced imaging may be a useful noninvasive method for evaluating the periportal lymphatic system and the degree of hepatic fibrosis.


Subject(s)
Gadolinium DTPA , Hepatitis C, Chronic/parasitology , Lymphatic System/diagnostic imaging , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Artifacts , Contrast Media , Female , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional , Male , Middle Aged , Retrospective Studies
18.
Kyobu Geka ; 69(13): 1106-1109, 2016 Dec.
Article in Japanese | MEDLINE | ID: mdl-27909281

ABSTRACT

An 81-year-old man presented with ruptured thoracic aortic aneurysm under stable condition. He had been suffering from chronic obstructive pulmonary disease, chronic renal failure and rheumatoid arthritis. We performed hybrid thoracic endovascular aortic repair via right anterior mini-thoracotomy inserting a device through a conduit on the ascending aorta. The patient was discharged without aorta-related complications.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Rupture/surgery , Stents , Aged, 80 and over , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Rupture/diagnostic imaging , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Male , Thoracotomy , Tomography, X-Ray Computed
19.
Abdom Radiol (NY) ; 41(9): 1722-7, 2016 09.
Article in English | MEDLINE | ID: mdl-27392744

ABSTRACT

PURPOSE: The aim of this study was to investigate the multidetector computed tomography (MDCT) features of strangulated ileus caused by epiploic appendix of the sigmoid colon. METHODS: We retrospectively evaluated MDCT images of four patients who underwent surgery in our hospital between 2011 and 2014. Patients were aged from 66 to 79 years, and two were female. RESULTS: Closed loop obstruction of the small bowel was confirmed in all patients. A fatty peritoneal band around the orifice of the ileus was detected in two patients, but was equivocal in the other two patients. Traction of the sigmoid colon toward the hilum of the closed loop of the small bowel was obvious in three patients. CONCLUSION: When traction of the sigmoid colon is detected in MDCT in a case of closed loop obstruction of the small bowel, strangulated ileus caused by an epiploic appendix should be considered in the differential diagnosis.


Subject(s)
Ileus , Aged , Appendix , Colon, Sigmoid , Female , Humans , Intestinal Obstruction , Male , Retrospective Studies
20.
Jpn J Radiol ; 34(8): 564-71, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27262856

ABSTRACT

PURPOSE: To investigate the current status of interventional radiology (IR) procedures for a type II endoleak (T2EL) in Japan, and to identify the technical aspects that affect treatment results. MATERIALS AND METHODS: A retrospective survey was conducted by distributing questionnaires to 25 institutions. The eligibility criteria were endovascular aortic repair (EVAR) performed using commercial stent grafts and IR performed for T2EL between January 2007 and December 2013. Technical success was defined as disappearance of the EL on digital subtraction angiography immediately after embolization, and imaging success was defined as no EL on contrast-enhanced computed tomography within 6 months. Statistical comparisons of the number of involved branches, embolization level, embolic material, and changes in aneurysm size were made between the imaging success and imaging failure groups. The technical and imaging success rates were also compared between the initial therapy and repeat groups. RESULTS: A total of 166 cases were investigated. Initial therapy was performed in 147 cases (88.6 %), with repeat therapy in 19 cases (11.4 %). Transcatheter arterial embolization (TAE) was used most frequently, in 161 cases (97 %), with direct puncture (DP) used in 5 cases (3 %). Both coil embolization for the branches and NBCA embolization for the sac were frequently chosen. The technical success rate was 83.2 % (TAE group), and the imaging success rate was 46.5 % (TAE + DP groups). Branch + sac embolization was performed more frequently in the imaging success group. There was no significant difference in the number of involved branches or embolic material between the imaging success and imaging failure groups. Enlargement of the aneurysm was more frequently seen in the imaging failure group. There were no significant differences in the technical success and imaging success rates between the initial therapy and repeat groups. CONCLUSION: This is the first report of a multi-institutional questionnaire survey of IR procedures for T2EL after EVAR in Japan that was conducted to determine the current status. Enlargement of aneurysm size after embolization was more frequently seen in the imaging failure group. It is important to embolize both branch and sac to achieve imaging success, regardless of embolic material. Long-term outcomes need to be investigated.


Subject(s)
Aortic Aneurysm, Abdominal/therapy , Embolization, Therapeutic/methods , Endoleak/diagnostic imaging , Radiology, Interventional/methods , Surveys and Questionnaires , Aged , Aged, 80 and over , Angiography, Digital Subtraction , Aortography , Contrast Media , Endovascular Procedures/methods , Female , Humans , Japan , Male , Middle Aged , Radiographic Image Enhancement , Retrospective Studies , Societies, Medical , Stents , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS