Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Exp Orthop ; 10(1): 98, 2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37768379

ABSTRACT

PURPOSE: Does the cylindrical shaped bone block allow a stable construct for the arthrodesis of the pubic symphysis compared to a rectangular shaped bone block. The cylindrical shaped bone block stabilized by a 3.5 symphyseal plate is inferior to the stabilization with an internal fixator. METHODS: This study analyzed the arthrodesis of the pubic symphysis on 24 synthetic pelvises, using a rectangular shaped bone block (control group) or a cylindrical shaped bone block, stabilized with a symphysis locking plate (n = 8) as the standard clinical procedure. Additionally we analyzed the stability using an internal fixator. RESULTS: This study showed that utilizing a cylindrical shaped synthetic bone graft results in a significant higher contact area and compression force compared to the classical rectangular shaped graft. Furthermore, the stabilization with an internal fixator had the tendency for increases of compression force and contact area, yet without a statistical significance, when compared to the plate fixation. CONCLUSION: The novel method of cylindrical symphysis resection and cylindrical bone block implantation allowed an increased biomechanical stability compared to using a classical rectangular bone graft, also resulting in higher contact area. Moreover, this technique would also allow a minimally invasive approach for this purpose, which in turn could preserve perisymphyseal ligaments, thereby improving healing in a clinical context.

2.
J Exp Orthop ; 7(1): 67, 2020 Sep 17.
Article in English | MEDLINE | ID: mdl-32940814

ABSTRACT

OBJECTIVE: Instability of the pubic symphysis often results in a poor outcome and reduced mobility of the patient. In some cases, an arthrodesis of the pubic symphysis is required. Until today, there is no data published how many of these procedures are performed annually and there is also no data about the outcome after this extensive surgery. METHODS: We developed a novel surgical technique to address the arthrodesis of the pubic symphysis in a minimally invasive approach. Therefore, we used for this purpose modified instruments and performed the transplantation of a cylindrical bone substitute into the pubic symphysis, without an extensive approach or dissecting the anterior or posterior symphyseal ligaments. RESULTS: Using this novel technique, a minimally invasive symphysiodesis was achieved in radiological findings, after the procedure. CONCLUSION: Thus, this actually minimally invasive surgical technique seems to be a promising advancement for the arthrodesis of the pubic symphysis.

3.
Clin Biomech (Bristol, Avon) ; 77: 105009, 2020 07.
Article in English | MEDLINE | ID: mdl-32454345

ABSTRACT

BACKGROUND: Pelvic fractures in adults are common injuries and account for up to 3.64% of all fractures. Usually, the treatment of open book injuries (Types B1.1 and B1.2 AO-Classification) is open reduction and plate stabilization using dynamic compression plates, with or without interlocking screws. These implants seem to enhance the outcome of such injuries, but also variety of complications occurs. To reduce complications and achieve appropriate reduction and stabilization, this study compared established stabilization techniques to a novel minimally invasive internal fixation method using an internal fixator system that is already being utilized for spinal fractures. METHODS: This study was performed on 32 composite pelvises in a bilateral stance biomechanical model. The pelvises were variously stabilized with an internal fixator, a 4.5 mm dynamic compression plate and a 3.5 mm symphyseal locking dynamic compression plate. The contact area and loading forces were assessed by a sensor film inside the symphyseal gap. FINDINGS: This study showed significantly greater reduction and loading capabilities of the internal fixator compared to the other implants (p < 0.05). There was also significantly greater contact area with the use of an internal fixator compared to the other implants (p < 0.05). The 3.5 mm interlocking plate showed significantly greater contact area compared to the 4.5 mm plate (p < 0.05). INTERPRETATION: The internal fixator that is already proven in spinal surgery is biomechanically superior to conventional implants used in pelvic surgery. The contact area analysis furthermore showed a more physiological loading pattern, which can improve ligamentous healing in a clinical context.


Subject(s)
Fracture Fixation, Internal/methods , Mechanical Phenomena , Pubic Symphysis/injuries , Pubic Symphysis/surgery , Adult , Biomechanical Phenomena , Bone Plates , Bone Screws , Female , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Humans , Male
4.
JBJS Case Connect ; 9(3): e0075, 2019.
Article in English | MEDLINE | ID: mdl-31469666

ABSTRACT

CASE: In this case report, we present a novel stabilization technique of the pubic symphysis using an internal spinal fixator in a 78-year-old morbidly obese woman having a pelvic disruption type B1.1 (AO classification). We treated the disruption using an internal fixator to reduce the extent of the incision and soft-tissue damage. CONCLUSIONS: The use of an internal fixator, known from percutaneous spinal fixation, for the stabilization of the pubic symphysis in cases of disruption ("open book" injuries) may be an alternative to the standard plate fixation as a novel minimally invasive stabilization technique.


Subject(s)
Fracture Fixation, Internal/methods , Obesity, Morbid/complications , Pubic Bone/injuries , Aged , Female , Humans , Internal Fixators , Minimally Invasive Surgical Procedures
SELECTION OF CITATIONS
SEARCH DETAIL
...