Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Publication year range
1.
Appl Opt ; 60(28): 8716-8727, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34613097

ABSTRACT

Particle image velocimetry (PIV) measurements in reactive flows are disturbed by inhomogeneous refractive index fields, which cause measurement deviations in particle positions due to light refraction. The resulting measurement errors are known for standard PIV, but the measurement errors for stereoscopic PIV are still unknown. Therefore, for comparison, the velocity errors for standard and stereoscopic PIV are analyzed in premixed propane flames with different Reynolds numbers. For this purpose, ray-tracing simulations based on the time-averaged inhomogeneous refractive index fields of the studied non-swirled flame flows measured by the background-oriented Schlieren technique are performed to quantify the resulting position errors of the particles. In addition, the performance of the volumetric self-calibration relevant to tomographic PIV is analyzed with respect to the remaining position errors of the particles within the flames. The position errors cause significant standard PIV errors of 2% for the velocity component radial to the burner symmetry axis. Stereoscopic PIV measurements result in measurement errors of up to 3% radial to the burner axis and 13% for the velocity component perpendicular to the measurement plane. Due to the lower refractive index gradients in the axial direction, no significant velocity errors are observed for the axial velocity component. For the investigated flame configurations, the position errors and velocity errors increase with the Reynolds numbers. However, this dependence needs to be verified for other flame configurations such as swirled flame flows.

3.
Fortschr Ophthalmol ; 88(2): 196-200, 1991.
Article in German | MEDLINE | ID: mdl-1855746

ABSTRACT

Twenty patients had retrobulbar anesthesia with 5 ml mepivacaine (Scandicain) without or with addition of 150 units of hyaluronidase (Kinetin). Before and 15 min after injection, we determined--by means of oculo-oscillo-dynamography--the systolic retinal and ciliary perfusion pressures, the respective ocular blood pressures (intramural pressures) and the ocular pulsation volume (PVoc) as well as the intraocular pressure (Pio; hand-applanation tonometer). Without hyaluronidase, the ocular perfusion and blood pressures were lowered by 11.8 and 3.9 mmHg, respectively, and PVoc was reduced by 0,40 microliters, whereas Pio was increased by 7.9 mmHg With hyaluronidase, the ocular perfusion and blood pressures were decreased by averages of 12.7 and 6.8 mmHg, respectively, PVoc was reduced by 0.42 microliters, and Pio was increased by 6.0 mmHg. Within each group, all changes were significant. There were, however, no significant differences between the two groups, i.e., the "spreading factor" hyaluronidase does not influence the inhibitory effects of retrobulbar anesthesia on ocular circulation.


Subject(s)
Anesthesia, Local , Eye/blood supply , Hyaluronoglucosaminidase/administration & dosage , Lenses, Intraocular , Mepivacaine , Aged , Humans , Middle Aged , Orbit/drug effects , Regional Blood Flow/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL