Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
BMC Res Notes ; 15(1): 151, 2022 Apr 29.
Article in English | MEDLINE | ID: mdl-35488286

ABSTRACT

OBJECTIVE: Doppler echocardiographic aortic valve peak velocity and peak pressure gradient assessment across the aortic valve (AV) is the mainstay for diagnosing aortic stenosis. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is emerging as a valuable diagnostic tool for estimating the peak pressure drop across the aortic valve, but assessment remains cumbersome. We aimed to validate a novel semi-automated pipeline 4D flow CMR method of assessing peak aortic value pressure gradient (AVPG) using the commercially available software solution, CAAS MR Solutions, against invasive angiographic methods. RESULTS: We enrolled 11 patients with severe AS on echocardiography from the EurValve programme. All patients had pre-intervention doppler echocardiography, invasive cardiac catheterisation with peak pressure drop assessment across the AV and 4D flow CMR. The peak AVPG was 51.9 ± 35.2 mmHg using the invasive pressure drop method and 52.2 ± 29.2 mmHg for the 4D flow CMR method (semi-automated pipeline), with good correlation between the two methods (r = 0.70, p = 0.017). Assessment of AVPG by 4D flow CMR using the novel semi-automated pipeline method shows excellent agreement to invasive assessment when compared to doppler-based methods and advocate for its use as complementary to echocardiography.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/pathology , Blood Flow Velocity , Echocardiography , Echocardiography, Doppler , Humans
2.
Quant Imaging Med Surg ; 11(4): 1470-1482, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33816183

ABSTRACT

BACKGROUND: Left ventricular (LV) kinetic energy (KE) assessment by four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) may offer incremental value over routine assessment in aortic stenosis (AS). The main objective of this study is to investigate the LV KE in patients with AS before and after the valve intervention. In addition, this study aimed to investigate if LV KE offers incremental value for its association to the six-minute walk test (6MWT) or LV remodelling post-intervention. METHODS: We recruited 18 patients with severe AS. All patients underwent transthoracic echocardiography for mean pressure gradient (mPG), CMR including 4D flow and 6MWT. Patients were invited for post-valve intervention follow-up CMR at 3 months and twelve patients returned for follow-up CMR. KE assessment of LV blood flow and the components (direct, delayed, retained and residual) were carried out for all cases. LV KE parameters were normalised to LV end-diastolic volume (LVEDV). RESULTS: For LV blood flow KE assessment, the metrics including time delay (TD) for peak E-wave from base to mid-ventricle (14±48 vs. 2.5±9.75 ms, P=0.04), direct (4.91±5.07 vs. 1.86±1.72 µJ, P=0.01) and delayed (2.46±3.13 vs. 1.38±1.15 µJ, P=0.03) components of LV blood flow demonstrated a significant change between pre- and post-valve intervention. Only LV KEiEDV (r=-0.53, P<0.01), diastolic KEiEDV (r=-0.53, P<0.01) and Ewave KEiEDV (r=-0.38, P=0.04) demonstrated association to the 6MWT. However, Pre-operative LV KEiEDV (r=0.67, P=0.02) demonstrated association to LV remodelling post valve intervention. CONCLUSIONS: LV blood flow KE is associated with 6MWT and LV remodelling in patients with AS. LV KE assessment provides incremental value over routine LV function and pressure gradient (PG) assessment in AS.

3.
Int J Cardiol ; 331: 316-321, 2021 05 15.
Article in English | MEDLINE | ID: mdl-33548381

ABSTRACT

BACKGROUND: There are several methods to quantify mitral regurgitation (MR) by cardiovascular magnetic resonance (CMR). The interoperability of these methods and their reproducibility remains undetermined. OBJECTIVE: To determine the agreement and reproducibility of different MR quantification methods by CMR across all aetiologies. METHODS: Thirty-five patients with MR were recruited (primary MR = 12, secondary MR = 10 and MVR = 13). Patients underwent CMR, including cines and four-dimensional flow (4D flow). Four methods were evaluated: MRStandard (left ventricular stroke volume - aortic forward flow by phase contrast), MRLVRV (left ventricular stroke volume - right ventricular stroke volume), MRJet (direct jet quantification by 4D flow) and MRMVAV (mitral forward flow by 4D flow - aortic forward flow by 4D flow). For all cases and MR types, 520 MR volumes were recorded by these 4 methods for intra-/inter-observer tests. RESULTS: In primary MR, MRMVAV and MRLVRV were comparable to MRStandard (P > 0.05). MRJet resulted in significantly higher MR volumes when compared to MRStandard (P < 0.05) In secondary MR and MVR cases, all methods were comparable. In intra-observer tests, MRMVAV demonstrated least bias with best limits of agreement (bias = -0.1 ml, -8 ml to 7.8 ml, P = 0.9) and best concordance correlation coefficient (CCC = 0.96, P < 0.01). In inter-observer tests, for primary MR and MVR, least bias and highest CCC were observed for MRMVAV. For secondary MR, bias was lowest for MRJet (-0.1 ml, PNS). CONCLUSION: CMR methods of MR quantification demonstrate agreement in secondary MR and MVR. In primary MR, this was not observed. Across all types of MR, MRMVAV quantification demonstrated the highest reproducibility and consistency.


Subject(s)
Mitral Valve Insufficiency , Humans , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Cine , Mitral Valve Insufficiency/diagnostic imaging , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Severity of Illness Index
4.
Wellcome Open Res ; 6: 253, 2021.
Article in English | MEDLINE | ID: mdl-37250619

ABSTRACT

Background: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). Methods: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MR MVAV and MR Jet) and two non-4D-flow techniques (MR Standard and MR LVRV). We conducted within-software and inter-software correlation and agreement analyses. Results: All methods demonstrated significant correlation between the two software solutions: MR Standard (r=0.92, p<0.001), MR LVRV (r=0.95, p<0.001), MR Jet (r=0.86, p<0.001), and MR MVAV (r=0.91, p<0.001). Between CAAS and MASS, MR Jet and MR MVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. Conclusions: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions.

5.
Sci Rep ; 10(1): 10569, 2020 06 29.
Article in English | MEDLINE | ID: mdl-32601326

ABSTRACT

The management of patients with aortic stenosis (AS) crucially depends on accurate diagnosis. The main aim of this study were to validate the four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR) methods for AS assessment. Eighteen patients with clinically severe AS were recruited. All patients had pre-valve intervention 6MWT, echocardiography and CMR with 4D flow. Of these, ten patients had a surgical valve replacement, and eight patients had successful transcatheter aortic valve implantation (TAVI). TAVI patients had invasive pressure gradient assessments. A repeat assessment was performed at 3-4 months to assess the remodelling response. The peak pressure gradient by 4D flow was comparable to an invasive pressure gradient (54 ± 26 mmHG vs 50 ± 34 mmHg, P = 0.67). However, Doppler yielded significantly higher pressure gradient compared to invasive assessment (61 ± 32 mmHG vs 50 ± 34 mmHg, P = 0.0002). 6MWT was associated with 4D flow CMR derived pressure gradient (r = -0.45, P = 0.01) and EOA (r = 0.54, P < 0.01) but only with Doppler EOA (r = 0.45, P = 0.01). Left ventricular mass regression was better associated with 4D flow derived pressure gradient change (r = 0.64, P = 0.04). 4D flow CMR offers an alternative method for non-invasive assessment of AS. In addition, 4D flow derived valve metrics have a superior association to prognostically relevant 6MWT and LV mass regression than echocardiography.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Cardiovascular System/physiopathology , Echocardiography/methods , Echocardiography, Doppler/methods , Female , Four-Dimensional Computed Tomography , Heart Valve Prosthesis Implantation/methods , Humans , Magnetic Resonance Imaging/methods , Male , Predictive Value of Tests , Prospective Studies , Stroke Volume/physiology , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Ventricular Function, Left/physiology
6.
NPJ Digit Med ; 3: 92, 2020.
Article in English | MEDLINE | ID: mdl-32665977

ABSTRACT

Wrist-worn devices with heart rate monitoring have become increasingly popular. Although current guidelines advise to consider clinical symptoms and exercise tolerance during decision-making in heart disease, it remains unknown to which extent wearables can help to determine such functional capacity measures. In clinical settings, the 6-minute walk test has become a standardized diagnostic and prognostic marker. We aimed to explore, whether 6-minute walk distances can be predicted by wrist-worn devices in patients with different stages of mitral and aortic valve disease. A total of n = 107 sensor datasets with 1,019,748 min of recordings were analysed. Based on heart rate recordings and literature information, activity levels were determined and compared to results from a 6-minute walk test. The percentage of time spent in moderate activity was a predictor for the achievement of gender, age and body mass index-specific 6-minute walk distances (p < 0.001; R 2 = 0.48). The uncertainty of these predictions is demonstrated.

8.
Front Cardiovasc Med ; 6: 103, 2019.
Article in English | MEDLINE | ID: mdl-31428619

ABSTRACT

Background: Four-dimensional flow cardiac magnetic resonance (4D flow CMR) is an emerging non-invasive imaging technology that can be used to quantify mitral regurgitation (MR) volume. Current methods of quantification have demonstrated limitations in accurate analysis, particularly in difficult cases such as complex congenital heart disease. 4D flow CMR methods aim to circumvent these limitations and allow accurate quantification of MR volume even in complex cases. This systematic review aims to summarize the available literature on 4D flow CMR MR quantification methods and examine their ability to accurately classify MR severity. Methods: Structured searches were carried out on Medline and EMBASE in December 2018 to identify suitable research outcome studies. The titles and abstracts were screened for relevance, with a third adjudicator utilized when study suitability was uncertain. Results: Seven studies met the eligibility criteria and were included in the systematic review. The most widely used 4D flow MRI method was retrospective valve tracking (RVT) which was examined in five papers. The key finding of these papers was that RVT is a reliable and accurate method of regurgitant volume quantification. Conclusions: MR quantification through 4D flow MRI is both feasible and accurate. The evidence gathered suggests that for MR assessment, 4D flow MRI is potentially as accurate and reliable to echocardiography and may be complementary to this technique. Further work on MR quantification 4D flow image analysis is needed to determine the most accurate analysis technique and to demonstrate 4D flow MRI as a predictor of clinical outcome. PROSPERO Registration Number: CRD42019122837, http://www.crd.york.ac.uk/PROSPERO/display_record.php?ID=CRD42019122837.

9.
Pulm Circ ; 6(2): 181-90, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27252844

ABSTRACT

Accurately identifying patients with pulmonary hypertension (PH) using noninvasive methods is challenging, and right heart catheterization (RHC) is the gold standard. Magnetic resonance imaging (MRI) has been proposed as an alternative to echocardiography and RHC in the assessment of cardiac function and pulmonary hemodynamics in patients with suspected PH. The aim of this study was to assess whether machine learning using computational modeling techniques and image-based metrics of PH can improve the diagnostic accuracy of MRI in PH. Seventy-two patients with suspected PH attending a referral center underwent RHC and MRI within 48 hours. Fifty-seven patients were diagnosed with PH, and 15 had no PH. A number of functional and structural cardiac and cardiovascular markers derived from 2 mathematical models and also solely from MRI of the main pulmonary artery and heart were integrated into a classification algorithm to investigate the diagnostic utility of the combination of the individual markers. A physiological marker based on the quantification of wave reflection in the pulmonary artery was shown to perform best individually, but optimal diagnostic performance was found by the combination of several image-based markers. Classifier results, validated using leave-one-out cross validation, demonstrated that combining computation-derived metrics reflecting hemodynamic changes in the pulmonary vasculature with measurement of right ventricular morphology and function, in a decision support algorithm, provides a method to noninvasively diagnose PH with high accuracy (92%). The high diagnostic accuracy of these MRI-based model parameters may reduce the need for RHC in patients with suspected PH.

10.
IEEE J Biomed Health Inform ; 19(4): 1209-15, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26218867

ABSTRACT

The idea that the purely phenomenological knowledge that we can extract by analyzing large amounts of data can be useful in healthcare seems to contradict the desire of VPH researchers to build detailed mechanistic models for individual patients. But in practice no model is ever entirely phenomenological or entirely mechanistic. We propose in this position paper that big data analytics can be successfully combined with VPH technologies to produce robust and effective in silico medicine solutions. In order to do this, big data technologies must be further developed to cope with some specific requirements that emerge from this application. Such requirements are: working with sensitive data; analytics of complex and heterogeneous data spaces, including nontextual information; distributed data management under security and performance constraints; specialized analytics to integrate bioinformatics and systems biology information with clinical observations at tissue, organ and organisms scales; and specialized analytics to define the "physiological envelope" during the daily life of each patient. These domain-specific requirements suggest a need for targeted funding, in which big data technologies for in silico medicine becomes the research priority.


Subject(s)
Databases, Factual , Medical Informatics , Precision Medicine , Humans
11.
Biomed Eng Online ; 12: 65, 2013 Jul 06.
Article in English | MEDLINE | ID: mdl-23829346

ABSTRACT

BACKGROUND: Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. METHODS: In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. RESULTS: Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. CONCLUSIONS: The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.


Subject(s)
Aortic Diseases/physiopathology , Hemodynamics , Models, Biological , Aortic Diseases/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Precision Medicine , Pressure , Shear Strength , Stress, Mechanical , Tomography, X-Ray Computed
12.
Med Biol Eng Comput ; 51(11): 1181-90, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23436208

ABSTRACT

Sharing data between scientists and with clinicians in cardiac research has been facilitated significantly by the use of web technologies. The potential of this technology has meant that information sharing has been routinely promoted through databases that have encouraged stakeholder participation in communities around these services. In this paper we discuss the Anatomical Model Database (AMDB) (Gianni et al. Functional imaging and modeling of the heart. Springer, Heidelberg, 2009; Gianni et al. Phil Trans Ser A Math Phys Eng Sci 368:3039-3056, 2010) which both facilitate a database-centric approach to collaboration, and also extends this framework with new capabilities for creating new mesh data. AMDB currently stores cardiac geometric models described in Gianni et al. (Functional imaging and modelling of the heart. Springer, Heidelberg, 2009), a number of additional cardiac models describing geometry and functional properties, and most recently models generated using a web service. The functional models represent data from simulations in geometric form, such as electrophysiology or mechanics, many of which are present in AMDB as part of a benchmark study. Finally, the heartgen service has been added for producing left or bi-ventricle models derived from binary image data using the methods described in Lamata et al. (Med Image Anal 15:801-813, 2011). The results can optionally be hosted on AMDB alongside other community-provided anatomical models. AMDB is, therefore, a unique database storing geometric data (rather than abstract models or image data) combined with a powerful web service for generating new geometric models.


Subject(s)
Databases, Factual , Internet , Models, Anatomic , Models, Cardiovascular , Animals , Humans , Information Dissemination , Software , Swine , User-Computer Interface
13.
Interface Focus ; 3(2): 20130004, 2013 Apr 06.
Article in English | MEDLINE | ID: mdl-24427536

ABSTRACT

European funding under Framework 7 (FP7) for the virtual physiological human (VPH) project has been in place now for 5 years. The VPH Network of Excellence (NoE) has been set up to help develop common standards, open source software, freely accessible data and model repositories, and various training and dissemination activities for the project. It is also working to coordinate the many clinically targeted projects that have been funded under the FP7 calls. An initial vision for the VPH was defined by the FP6 STEP project in 2006. In 2010, we wrote an assessment of the accomplishments of the first two years of the VPH in which we considered the biomedical science, healthcare and information and communications technology challenges facing the project (Hunter et al. 2010 Phil. Trans. R. Soc. A 368, 2595-2614 (doi:10.1098/rsta.2010.0048)). We proposed that a not-for-profit professional umbrella organization, the VPH Institute, should be established as a means of sustaining the VPH vision beyond the time-frame of the NoE. Here, we update and extend this assessment and in particular address the following issues raised in response to Hunter et al.: (i) a vision for the VPH updated in the light of progress made so far, (ii) biomedical science and healthcare challenges that the VPH initiative can address while also providing innovation opportunities for the European industry, and (iii) external changes needed in regulatory policy and business models to realize the full potential that the VPH has to offer to industry, clinics and society generally.

14.
Interface Focus ; 1(3): 349-64, 2011 Jun 06.
Article in English | MEDLINE | ID: mdl-22670205

ABSTRACT

The loss of cardiac pump function accounts for a significant increase in both mortality and morbidity in Western society, where there is currently a one in four lifetime risk, and costs associated with acute and long-term hospital treatments are accelerating. The significance of cardiac disease has motivated the application of state-of-the-art clinical imaging techniques and functional signal analysis to aid diagnosis and clinical planning. Measurements of cardiac function currently provide high-resolution datasets for characterizing cardiac patients. However, the clinical practice of using population-based metrics derived from separate image or signal-based datasets often indicates contradictory treatments plans owing to inter-individual variability in pathophysiology. To address this issue, the goal of our work, demonstrated in this study through four specific clinical applications, is to integrate multiple types of functional data into a consistent framework using multi-scale computational modelling.

15.
Article in English | MEDLINE | ID: mdl-20879338

ABSTRACT

Cubic Hermite meshes provide an efficient representation of anatomy, and are useful for simulating soft tissue mechanics. However, their personalization can be a complex, time consuming and labour-intensive process. This paper presents a method based on image registration and using an existing template for deriving a patient-specific cubic Hermite mesh. Its key contribution is a solution to customise a Hermite continuous description of a shape with the use of a discrete warping field. Fitting accuracy is first tested and quantified against an analytical ground truth solution. To then demonstrate its clinical utility, a generic cubic Hermite heart ventricular model is personalized to the anatomy of a patient, and its mechanical stability is successfully tested. The method achieves an easy, fast and accurate personalization of cubic Hermite meshes, constituting a crucial step for the clinical adoption of physiological simulations.


Subject(s)
Algorithms , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Models, Anatomic , Models, Biological , Computer Simulation , Finite Element Analysis , Reproducibility of Results , Sensitivity and Specificity
16.
IEEE Trans Inf Technol Biomed ; 14(6): 1365-77, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20435543

ABSTRACT

The increasing volume of data describing human disease processes and the growing complexity of understanding, managing, and sharing such data presents a huge challenge for clinicians and medical researchers. This paper presents the @neurIST system, which provides an infrastructure for biomedical research while aiding clinical care, by bringing together heterogeneous data and complex processing and computing services. Although @neurIST targets the investigation and treatment of cerebral aneurysms, the system's architecture is generic enough that it could be adapted to the treatment of other diseases. Innovations in @neurIST include confining the patient data pertaining to aneurysms inside a single environment that offers clinicians the tools to analyze and interpret patient data and make use of knowledge-based guidance in planning their treatment. Medical researchers gain access to a critical mass of aneurysm related data due to the system's ability to federate distributed information sources. A semantically mediated grid infrastructure ensures that both clinicians and researchers are able to seamlessly access and work on data that is distributed across multiple sites in a secure way in addition to providing computing resources on demand for performing computationally intensive simulations for treatment planning and research.


Subject(s)
Computer Communication Networks , Database Management Systems , Disease Management , Information Dissemination/methods , Medical Informatics/methods , Aneurysm/therapy , Biomedical Research , Computer Security , Europe , Humans
17.
Philos Trans A Math Phys Eng Sci ; 368(1920): 2595-614, 2010 Jun 13.
Article in English | MEDLINE | ID: mdl-20439264

ABSTRACT

European funding under framework 7 (FP7) for the virtual physiological human (VPH) project has been in place now for nearly 2 years. The VPH network of excellence (NoE) is helping in the development of common standards, open-source software, freely accessible data and model repositories, and various training and dissemination activities for the project. It is also helping to coordinate the many clinically targeted projects that have been funded under the FP7 calls. An initial vision for the VPH was defined by framework 6 strategy for a European physiome (STEP) project in 2006. It is now time to assess the accomplishments of the last 2 years and update the STEP vision for the VPH. We consider the biomedical science, healthcare and information and communications technology challenges facing the project and we propose the VPH Institute as a means of sustaining the vision of VPH beyond the time frame of the NoE.


Subject(s)
Computer Simulation/trends , Forecasting , Models, Biological , Physiological Phenomena/physiology , Physiology/trends , Systems Biology/trends , User-Computer Interface , Humans , Systems Integration
18.
Ultrasound Med Biol ; 35(12): 2069-83, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19828230

ABSTRACT

A system for acquisition of 3-D arterial ultrasound geometries and integration with computational fluid dynamics (CFD) is described. The 3-D ultrasound is based on freehand B-mode imaging with positional information obtained using an optical tracking system. A processing chain was established, allowing acquisition of cardiac-gated 3-D data and segmentation of arterial geometries using a manual method and a semi-automated method, 3D meshing and CFD. The use of CFD allowed visualization of flow streamlines, 2-D velocity contours and 3-D wall shear stress. Three-dimensional positional accuracy was 0.17-1.8mm, precision was 0.06-0.47mm and volume accuracy was 4.4-15%. Patients with disease and volunteers were scanned, with data collection from one or more of the carotid bifurcation, femoral bifurcation and abdominal aorta. An initial comparison between a manual segmentation method and a semi-automated method suggested some advantages to the semi-automated method, including reduced operator time and the production of smooth surfaces suitable for CFD, but at the expense of over-smoothing in the diseased region. There were considerable difficulties with artefacts and poor image quality, resulting in 3-D geometry data that was unsuitable for CFD. These artefacts were exacerbated in disease, which may mean that future effort, in the integration of 3-D arterial geometry and CFD for clinical use, may best be served using alternative 3-D imaging modalities such as magnetic resonance imaging and computed tomography.


Subject(s)
Algorithms , Arteries/physiology , Blood Flow Velocity/physiology , Imaging, Three-Dimensional/methods , Models, Cardiovascular , Rheology/methods , Ultrasonography/methods , Computer Simulation , Humans , Systems Integration
19.
Biomed Eng Online ; 8: 23, 2009 Oct 02.
Article in English | MEDLINE | ID: mdl-19799782

ABSTRACT

BACKGROUND: Systolic blood flow has been simulated in the abdominal aorta and the superior mesenteric artery. The simulations were carried out using two different computational hemodynamic methods: the finite element method to solve the Navier Stokes equations and the lattice Boltzmann method. RESULTS: We have validated the lattice Boltzmann method for systolic flows by comparing the velocity and pressure profiles of simulated blood flow between methods. We have also analyzed flow-specific characteristics such as the formation of a vortex at curvatures and traces of flow. CONCLUSION: The lattice Boltzmann Method is as accurate as a Navier Stokes solver for computing complex blood flows. As such it is a good alternative for computational hemodynamics, certainly in situation where coupling to other models is required.


Subject(s)
Mesenteric Arteries/anatomy & histology , Models, Cardiovascular , Algorithms , Aorta, Abdominal/anatomy & histology , Aorta, Abdominal/physiology , Biomedical Engineering , Blood Flow Velocity/physiology , Computer Simulation , Finite Element Analysis , Hemodynamics , Humans , Mesenteric Arteries/physiology , Models, Statistical , Software , Systole , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...