Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Nephrol ; 20(1): 197, 2019 05 31.
Article in English | MEDLINE | ID: mdl-31151432

ABSTRACT

BACKGROUND: Successful vascular access (VA) cannulation is integral to the delivery of adequate dialysis, highlighting the importance of ensuring the viability of arteriovenous access in hemodialysis (HD) patients. Missed VA cannulation can lead to infection, infiltration, hematoma or aneurysm formation resulting in the need for access revision, central venous catheter (CVC) placement, or permanent loss of VA. Cannulation-related complications can also negatively impact on a patient's dialysis experience and quality of life. This study aimed to identify patient, VA and nurse factors associated with unsuccessful VA cannulations. METHODS: A prospective cohort study was conducted in HD patients with a permanent VA from three HD units. Data on patient, VA and nurse characteristics, plus, cannulation technique were collected for each episode of cannulation. General Estimating Equation was used to fit a repeated measures logistic regression to determine the odds of cannulation success. RESULTS: We collected data on 1946 episodes of cannulation (83.9% fistula) in 149 patients by 63 nurses. Cannulation included use of tourniquet (62.9%), ultrasound (4.1%) and was by rope ladder (73.8%) or area (24.7%) technique. The miscannulation rate was 4.4% (n = 85) with a third of patients (n = 47) having at least one episode of miscannulation. Extravasation (n = 17, 0.9%) and use of an existing CVC (n = 6, 0.6%) were rare. Multivariable characteristics of successful cannulation included fistula compared with graft [OR 4.38; 95%CI, 1.89-10.1]; older access [OR 1.68; 95%CI, 1.32-2.14]; absence of stent [OR 3.37; 95%CI, 1.39-8.19]; no ultrasound [OR 13.7; 95%CI, 6.52-28.6]; no tourniquet [OR 2.32; 95%CI, 1.15-4.66]; and lack of post graduate certificate in renal nursing [OR 2.27; 95%CI, 1.31-3.93]. CONCLUSION: This study demonstrated a low rate of miscannulation. Further research is required on ultrasound-guided cannulation. Identifying variables associated with successful cannulation may be used to develop a VA cannulation complexity instrument that could be utilised to match to the cannulation skill of a competency-assessed nurse, thereby minimising the risk of missed cannulation and trauma.


Subject(s)
Catheterization/trends , Catheters, Indwelling/trends , Kidney Failure, Chronic/therapy , Renal Dialysis/trends , Vascular Access Devices/trends , Adult , Aged , Aged, 80 and over , Catheterization/adverse effects , Catheterization/instrumentation , Catheters, Indwelling/adverse effects , Cohort Studies , Female , Humans , Kidney Failure, Chronic/blood , Kidney Failure, Chronic/physiopathology , Male , Middle Aged , Prospective Studies , Renal Dialysis/adverse effects , Renal Dialysis/instrumentation , Vascular Access Devices/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...