1.
Front Bioeng Biotechnol ; 12: 1352794, 2024.
Article in English | MEDLINE | ID: mdl-38686117

ABSTRACT

As a solution to restore knee function and reduce pain, the demand for Total Knee Arthroplasty (TKA) has dramatically increased in recent decades. The high rates of dissatisfaction and revision makes it crucially important to understand the relationships between surgical factors and post-surgery knee performance. Tibial implant alignment in the sagittal plane (i.e., posterior tibia slope, PTS) is thought to play a key role in quadriceps muscle forces and contact conditions of the joint, but the underlying mechanisms and potential consequences are poorly understood. To address this biomechanical challenge, we developed a subject-specific musculoskeletal model based on the bone anatomy and precise implantation data provided within the CAMS-Knee datasets. Using the novel COMAK algorithm that concurrently optimizes joint kinematics, together with contact mechanics, and muscle and ligament forces, enabled highly accurate estimations of the knee joint biomechanics (RMSE <0.16 BW of joint contact force) throughout level walking and squatting. Once confirmed for accuracy, this baseline modelling framework was then used to systematically explore the influence of PTS on knee joint biomechanics. Our results indicate that PTS can greatly influence tibio-femoral translations (mainly in the anterior-posterior direction), while also suggesting an elevated risk of patellar mal-tracking and instability. Importantly, however, an increased PTS was found to reduce the maximum tibio-femoral contact force and improve efficiency of the quadriceps muscles, while also reducing the patellofemoral contact force (by approximately 1.5% for each additional degree of PTS during walking). This study presents valuable findings regarding the impact of PTS variations on the biomechanics of the TKA joint and thereby provides potential guidance for surgically optimizing implant alignment in the sagittal plane, tailored to the implant design and the individual deficits of each patient.

2.
Article in English | MEDLINE | ID: mdl-37128680

ABSTRACT

Despite availability of in vivo knee loads and kinematics data, conventional load- and displacement-controlled configurations still can't accurately predict tibiofemoral loads from kinematics or vice versa. We propose a combined load- and displacement-control method for joint-level simulations of the knee to reliably reproduce in vivo contact mechanics. Prediction errors of the new approach were compared to those of conventional purely load- or displacement-controlled models using in vivo implant loads and kinematics for multiple subjects and activities (CAMS-Knee dataset). Our method reproduced both loads and kinematics more closely than conventional models and thus demonstrates clear advantages for investigating tibiofemoral contact or wear.

3.
J Hand Surg Eur Vol ; 48(5): 435-444, 2023 05.
Article in English | MEDLINE | ID: mdl-36814409

ABSTRACT

Assessment of scaphoid fracture union on computed tomography scans is not currently standardized. We investigated the extent of scaphoid waist fracture union required to withstand physiological loads in a finite element model, based on a high-resolution CT scan of a cadaveric forearm. For simulations, the scaphoid waist was partially fused at the radial and ulnar sides. A physiological load of 100 N was transmitted to the scaphoid and the minimal amount of union to maintain biomechanical stability was recorded. The orientation of the fracture plane was varied to analyse the effect on biomechanical stability. The results indicate that the scaphoid is more prone to re-fracture when healing occurs on the ulnar side, where at least 60% union is required. Union occurring from the radial side can withstand loads with as little as 25% union. In fractures more parallel to the radial axis, the scaphoid seems less resistant on the radial side, as at least 50% union is required. A quantitative CT scan analysis with the proposed cut-off values and a consistently applied clinical examination will guide the clinician as to whether mid-waist scaphoid fractures can be considered as truly united.


Subject(s)
Fractures, Bone , Hand Injuries , Scaphoid Bone , Wrist Injuries , Humans , Fractures, Bone/diagnostic imaging , Finite Element Analysis , Scaphoid Bone/diagnostic imaging , Scaphoid Bone/injuries , Tomography, X-Ray Computed , Fracture Fixation, Internal/methods
4.
J Biomech ; 141: 111171, 2022 08.
Article in English | MEDLINE | ID: mdl-35803037

ABSTRACT

Knowledge of both tibio-femoral kinematics and kinetics is necessary for fully understanding knee joint biomechanics, guiding implant design and testing, and driving and validating computational models. In 2017, the CAMS-Knee datasets were presented, containing synchronized in vivo implant kinematics measured using a moving fluoroscope and tibio-femoral contact loads measured using instrumented implants from six subjects. However, to date, no representative summary of kinematics and kinetics obtained from measurements at the joint level of the same cohort of subjects exists. In this study, we present the CAMS-Knee standardized subject "Stan", whose reference data include tibio-femoral kinematics and loading scenarios from all six subjects for level and downhill walking, stair descent, squat and sit-to-stand-to-sit. Using the peak-preserving averaging method by Bergmann and co-workers, we derived scenarios for generally high (CAMS-HIGH100), peak, and extreme loading. The CAMS-HIGH100 axial forces reached peaks between 3022 and 3856 N (3.08-3.93 body weight) for the five investigated activities. Anterior-posterior forces were about a factor of ten lower. The axial moment around the tibia was highest for level walking and squatting with peaks of 9.4 Nm and 10.5 Nm acting externally. Internal tibial rotations of up to 8.4° were observed during squat and sitting, while the walking activities showed approximately half the internal rotation. The CAMS-HIGH100 loads were comparable to Bergmann and co-workers', but have the additional benefit of synchronized kinematics. Stan's loads are +11 to +56% higher than the ISO 14243 wear testing standard loads, while the kinematics exhibit markedly different curve shapes. Along with the original CAMS-Knee datasets, Stan's data can be requested at cams-knee.orthoload.com.


Subject(s)
Awards and Prizes , Knee Prosthesis , Biomechanical Phenomena , Femur , Humans , Knee Joint , Tibia
5.
Front Bioeng Biotechnol ; 10: 808027, 2022.
Article in English | MEDLINE | ID: mdl-35721846

ABSTRACT

Understanding the sources of error is critical before models of the musculoskeletal system can be usefully translated. Using in vivo measured tibiofemoral forces, the impact of uncertainty in muscle-tendon parameters on the accuracy of knee contact force estimates of a generic musculoskeletal model was investigated following a probabilistic approach. Population variability was introduced to the routine musculoskeletal modeling framework by perturbing input parameters of the lower limb muscles around their baseline values. Using ground reaction force and skin marker trajectory data collected from six subjects performing body-weight squat, the knee contact force was calculated for the perturbed models. The combined impact of input uncertainties resulted in a considerable variation in the knee contact force estimates (up to 2.1 BW change in the predicted force), especially at larger knee flexion angles, hence explaining up to 70% of the simulation error. Although individual muscle groups exhibited different contributions to the overall error, variation in the maximum isometric force and pathway of the muscles showed the highest impacts on the model outcomes. Importantly, this study highlights parameters that should be personalized in order to achieve the best possible predictions when using generic musculoskeletal models for activities involving deep knee flexion.

6.
J Clin Med ; 9(7)2020 Jul 02.
Article in English | MEDLINE | ID: mdl-32630654

ABSTRACT

This study aimed to understand the ability of fixed-bearing posterior cruciate ligament (PCL)-retaining implants to maintain functionality of the PCL in vivo. To achieve this, elongation of the PCL was examined in six subjects with good clinical and functional outcomes using 3D kinematics reconstructed from video-fluoroscopy, together with multibody modelling of the knee. Here, length-change patterns of the ligament bundles were tracked throughout complete cycles of level walking and stair descent. Throughout both activities, elongation of the anterolateral bundle exhibited a flexion-dependent pattern with more stretching during swing than stance phase (e.g., at 40° flexion, anterolateral bundle experienced 3.9% strain during stance and 9.1% during swing phase of stair descent). The posteromedial bundle remained shorter than its reference length (defined at heel strike of the level gait cycle) during both activities. Compared with loading patterns of the healthy ligament, postoperative elongation patterns indicate a slackening of the ligament at early flexion followed by peak ligament lengths at considerably smaller flexion angles. The reported data provide a novel insight into in vivo PCL function during activities of daily living that has not been captured previously. The findings support previous investigations reporting difficulties in achieving a balanced tension in the retained PCL.

7.
Ann Biomed Eng ; 48(4): 1442, 2020 04.
Article in English | MEDLINE | ID: mdl-32125572

ABSTRACT

The article The Capacity of Generic Musculoskeletal Simulations to Predict Knee Joint Loading Using the CAMS-Knee Datasets, written by Zohreh Imani Nejad et al., was originally published electronically on the publisher's internet portal on January 30, 2020 without open access. With the author(s)' decision to opt for Open Choice the copyright of the article changed on February 18, 2020 to © The Author(s) 2020 and the article is forthwith distributed under a Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

8.
Ann Biomed Eng ; 48(4): 1430-1440, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32002734

ABSTRACT

Musculoskeletal models enable non-invasive estimation of knee contact forces (KCFs) during functional movements. However, the redundant nature of the musculoskeletal system and uncertainty in model parameters necessitates that model predictions are critically evaluated. This study compared KCF and muscle activation patterns predicted using a scaled generic model and OpenSim static optimization tool against in vivo measurements from six patients in the CAMS-knee datasets during level walking and squatting. Generally, the total KCFs were under-predicted (RMS: 47.55%BW, R2: 0.92) throughout the gait cycle, but substiantially over-predicted (RMS: 105.7%BW, R2: 0.81) during squatting. To understand the underlying etiology of the errors, muscle activations were compared to electromyography (EMG) signals, and showed good agreement during level walking. For squatting, however, the muscle activations showed large descrepancies especially for the biceps femoris long head. Errors in the predicted KCF and muscle activation patterns were greatest during deep squat. Hence suggesting that the errors mainly originate from muscle represented at the hip and an associated muscle co-contraction at the knee. Furthermore, there were substaintial differences in the ranking of subjects and activities based on peak KCFs in the simulations versus measurements. Thus, future simulation study designs must account for subject-specific uncertainties in musculoskeletal predictions.


Subject(s)
Knee Joint/physiology , Models, Biological , Muscle, Skeletal/physiology , Aged , Biomechanical Phenomena , Computer Simulation , Female , Humans , Male , Middle Aged , Movement/physiology
9.
Am J Sports Med ; 48(3): 754-766, 2020 03.
Article in English | MEDLINE | ID: mdl-31091114

ABSTRACT

BACKGROUND: As the main passive structure preventing patellar lateral subluxation, accurate knowledge of the anatomy, material properties, and functional behavior of the medial patellofemoral ligament (MPFL) is critical for improving its reconstruction. PURPOSE: To provide a state-of-the-art understanding of the properties and function of the MPFL by undertaking a systematic review and statistical analysis of the literature. STUDY DESIGN: Systematic review. METHODS: On June 26, 2018, data for this systematic review were obtained by searching PubMed and Scopus. Articles containing numerical information regarding the anatomy, mechanical properties, and/or functional behavior of the MPFL that met the inclusion criteria were reviewed, recorded, and statistically evaluated. RESULTS: A total of 55 articles met the inclusion criteria for this review. The MPFL presented as a fanlike structure spanning from the medial femoral epicondyle to the medial border of the patella. The reported data indicated ultimate failure loads from 72 N to 208 N, ultimate failure elongation from 8.4 mm to 26 mm, and stiffness values from 8.0 N/mm to 42.5 N/mm. In both cadaveric and in vivo studies, the average elongation pattern demonstrated close to isometric behavior of the ligament in the first 50° to 60° of knee flexion, followed by progressive shortening into deep flexion. Kinematic data suggested clear lateralization of the patella in the MPFL-deficient knee during early knee flexion under simulated muscle forces. CONCLUSION: A lack of knowledge regarding the morphology and attachment sites of the MPFL remains. The reported mechanical properties also lack consistency, thus requiring further investigations. However, the results regarding patellar tracking confirm that the lack of an MPFL leads to lateralization of the patella, followed by delayed engagement of the trochlear groove, plausibly leading to an increased risk of patellar dislocations. The observed isometric behavior up to 60° of knee flexion plausibly suggests that reconstruction of the ligament can occur at flexion angles below 60°, including the 30° and 60° range as recommended in previous studies.


Subject(s)
Knee Joint/surgery , Ligaments, Articular/surgery , Patellofemoral Joint/surgery , Biomechanical Phenomena , Femur/surgery , Humans , Joint Dislocations/physiopathology , Patellar Dislocation/surgery , Range of Motion, Articular/physiology
10.
Article in English | MEDLINE | ID: mdl-31799245

ABSTRACT

The primary aim of this study was to assess the effects of total knee arthroplasty (TKA) implant design on collateral ligament elongation patterns that occur during level walking, downhill walking, and stair descent. Using a moving fluoroscope, tibiofemoral kinematics were captured in three groups of patients with different TKA implant designs, including posterior stabilized, medial stabilized, and ultra-congruent. The 3D in vivo joint kinematics were then fed into multibody models of the replaced knees and elongation patterns of virtual bundles connecting origin and insertion points of the medial and lateral collateral ligaments (MCL and LCL) were determined throughout complete cycles of all activities. Regardless of the implant design and activity type, non-isometric behavior of the collateral ligaments was observed. The LCL shortened with increasing knee flexion, while the MCL elongation demonstrated regional variability, ranging from lengthening of the anterior bundle to slackening of the posterior bundle. The implant component design did not demonstrate statistically significant effects on the collateral elongation patterns and this was consistent between the studied activities. This study revealed that post-TKA collateral ligament elongation is primarily determined by the knee flexion angle. The different anterior translation and internal rotation that were induced by three distinctive implant designs had minimal impact on the length change patterns of the collateral ligaments.

11.
PLoS One ; 14(5): e0217460, 2019.
Article in English | MEDLINE | ID: mdl-31150452

ABSTRACT

A stable walking pattern is presumably essential to avoid falls. Stability of walking is most accurately determined by the short-term local dynamic stability (maximum Lyapunov exponent) of the body centre of mass. In many studies related to fall risk, however, variability of step width is considered to be indicative of the stability of the centre of mass during walking. However, other footfall parameters, in particular variability of stride time, have also been associated with increased risk for falling. Therefore, the aim of this study was to investigate the association between short-term local dynamic stability of the body centre of mass and different measures of footfall variability. Twenty subjects performed unperturbed walking trials on a treadmill and under increased (addition of 40% body weight) and decreased (harness system) demands to stabilise the body centre of mass. Association between stability of the centre of mass and footfall parameters was established using a structural equation model. Walking with additional body weight lead to greater instability of the centre of mass and increased stride time variability, however had no effect on step width variability. Supported walking in the harness system did not increase centre of mass stability further, however, led to a significant decrease of step width and increase in stride time variability. A structural equation model could only predict 8% of the variance of the centre of mass stability after variability of step width, stride time and stride length were included. A model which included only step width variability as exogenous variable, failed to predict centre of mass stability. Because of the failure to predict centre of mass stability in this study, it appears, that the stability of the centre of mass is controlled by more complex interaction of sagittal and frontal plane temporal and spatial footfall parameters, than those observed by standard variability measures. Anyway, this study does not support the application of step width variability as indicator for medio-lateral stability of the centre of mass during walking.


Subject(s)
Gait/physiology , Postural Balance/physiology , Adult , Biomechanical Phenomena , Female , Foot/physiology , Healthy Volunteers , Humans , Male , Models, Biological , Spatio-Temporal Analysis , Young Adult
12.
J Biomech ; 65: 32-39, 2017 Dec 08.
Article in English | MEDLINE | ID: mdl-29037443

ABSTRACT

Combined knowledge of the functional kinematics and kinetics of the human body is critical for understanding a wide range of biomechanical processes including musculoskeletal adaptation, injury mechanics, and orthopaedic treatment outcome, but also for validation of musculoskeletal models. Until now, however, no datasets that include internal loading conditions (kinetics), synchronized with advanced kinematic analyses in multiple subjects have been available. Our goal was to provide such datasets and thereby foster a new understanding of how in vivo knee joint movement and contact forces are interlinked - and thereby impact biomechanical interpretation of any new knee replacement design. In this collaborative study, we have created unique kinematic and kinetic datasets of the lower limb musculoskeletal system for worldwide dissemination by assessing a unique cohort of 6 subjects with instrumented knee implants (Charité - Universitätsmedizin Berlin) synchronized with a moving fluoroscope (ETH Zürich) and other measurement techniques (including whole body kinematics, ground reaction forces, video data, and electromyography data) for multiple complete cycles of 5 activities of daily living. Maximal tibio-femoral joint contact forces during walking (mean peak 2.74 BW), sit-to-stand (2.73 BW), stand-to-sit (2.57 BW), squats (2.64 BW), stair descent (3.38 BW), and ramp descent (3.39 BW) were observed. Internal rotation of the tibia ranged from 3° external to 9.3° internal. The greatest range of anterio-posterior translation was measured during stair descent (medial 9.3 ±â€¯1.0 mm, lateral 7.5 ±â€¯1.6 mm), and the lowest during stand-to-sit (medial 4.5 ±â€¯1.1 mm, lateral 3.7 ±â€¯1.4 mm). The complete and comprehensive datasets will soon be made available online for public use in biomechanical and orthopaedic research and development.


Subject(s)
Knee Joint/physiology , Muscle, Skeletal/physiology , Activities of Daily Living , Aged , Biomechanical Phenomena , Electromyography , Female , Femur/physiology , Humans , Kinetics , Knee Prosthesis , Lower Extremity/physiology , Male , Middle Aged , Rotation , Tibia/physiology , Walking/physiology