Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Front Cardiovasc Med ; 10: 1185518, 2023.
Article in English | MEDLINE | ID: mdl-37265566

ABSTRACT

Introduction: The extent of the hemodynamic benefit from AV-synchronous pacing in patients with sinus rhythm and AV block is not completely understood. Thus, we systematically investigated the association of an array of echocardiographic and epidemiological parameters with the change in cardiac output depending on the stimulation mode (AV-synchronous or AV-asynchronous pacing). Methods: Patients in sinus rhythm after previous dual chamber pacemaker implantation underwent a thorough basic echocardiographic assessment of diastolic and systolic left ventricular function, and atrial function (26 echo parameters, including novel speckle tracking strain measurements). Then, stroke volume was measured with AV-synchronous (DDD) and AV-asynchronous (VVI) pacing. Each patient represented their own control, and the sequence of stroke volume measurements was randomized. Results: In this prospective single-center study (NCT04068233, registration August 22nd 2019), we recruited 40 individuals. The stroke volume was higher in all patients when applying AV-synchronous DDD pacing [median increase 12.8 ml (16.9%), P < 0.001]. No echo parameter under investigation was associated with the extent of stroke volume increase in a linear regression model. Of all epidemiological variables, a history of acute myocardial infarction (AMI) was associated with an attenuated stroke volume gain in a univariate and a multivariate regression model that adjusted for confounders. A- and S-wave velocities were reduced in the AMI group. Discussion: In our cohort of patients, each subject benefited from AV-synchronous DDD pacing. No single echo parameter could predict the amount of stroke volume increase. The beneficial effect of AV-synchronous pacing on stroke volume was attenuated after prior acute myocardial infarction.ClinicalTrials.gov identifier (NCT number): NCT04068233.

2.
J Clin Med ; 11(24)2022 Dec 14.
Article in English | MEDLINE | ID: mdl-36556020

ABSTRACT

NT-pro-BNP is produced in the cardiac atria and ventricles in response to increased wall stress. It may be a marker of both AF disease progression and co-morbidities that affect success after pulmonary vein isolation (PVI). This single-center retrospective study analyzed the association between pre-procedural NT-pro-BNP serum levels and the long-term outcome after a first-ever PVI in cryo-technique. Patients were followed by searching the hospital information system and conducting structured telephone interviews. Treatment failure was defined as any relapse of atrial fibrillation (AF) occurring 90 days after the index PVI at the earliest. Kaplan−Meier survival curves and Cox proportional hazards models were computed to assess the impact of NT-pro-BNP on AF recurrence. Following 374 patients over a median of 3.8 years (range: 0.25−9.4 years), baseline NT-pro-BNP was associated with the combined endpoint in univariate analysis (HR 1.04 per 100 pg/mL increase, 95% CI: 1.02−1.07, p < 0.001). Results were virtually unchanged in the multivariate model or if the data were log-transformed. Intraprocedural left atrial pressure correlated positively with log NT-pro-BNP. NT-pro-BNP was associated with AF relapse during a long-term follow-up after first-ever cryo-PVI in our cohort of patients with predominantly normal left ventricular function. This lab parameter is easy to obtain and has significant potential to guide treatment decisions.

3.
J Clin Med ; 11(5)2022 Feb 28.
Article in English | MEDLINE | ID: mdl-35268413

ABSTRACT

This multicenter European survey systematically evaluated the impact of using contact force-sensing catheters (CFSCs) on fluoroscopy and procedure time in interventional electrophysiology. Data from 25 participating centers were collected and analyzed, also considering important confounders. With the use of CFSCs, fluoroscopy time was reduced for right- and left-sided atrial ablations (median −6.4 to −9.6 min, p < 0.001 for both groups), whereas no such effect could be found for ventricular ablations. Moreover, the use of CFSCs was associated with an increase in procedure time for right-sided atrial and ventricular ablations (median +26.0 and +44.0 min, respectively, p < 0.001 for both groups), but not for left-sided atrial ablations. These findings were confirmed independent of career level and operator volume, except for very highly experienced electrophysiologists, in whom the effect was blunted. In the subset of pulmonary vein isolations (PVIs), CFSCs were shown to reduce both fluoroscopy and procedure time. In conclusion, the use of CFSCs was associated with a reduced fluoroscopy time for atrial ablations and an increased procedure time for right atrial and ventricular ablations. These effects were virtually independent of the operator experience and caseload. When considering only PVIs as an important subset, CFSCs were shown to reduce both fluoroscopy and procedure time.

4.
Am J Cardiol ; 140: 69-77, 2021 02 01.
Article in English | MEDLINE | ID: mdl-33152317

ABSTRACT

Patients with symptomatic, drug-refractory atrial fibrillation (AF) are frequently treated with catheter ablation. Cryo-ablation has been established as an alternative to radiofrequency ablation but long-term outcome data are still limited. This study aimed at elucidating the influence of the left atrial volume index (LAVI), derived from cardiac computed tomography (cCT) data, on the long-term outcome of ablation-naïve AF patients, after their first cryo-ablation. 415 patients (n = 290 [69.90%] male, 60.00 [IQR: 53.00 to 68.00] years old) who underwent a cCT and subsequent cryo-ablation index procedure were included in this single centre retrospective data analysis. A composite end point was defined (AF on electrocardiogram and/or electric cardioversion and/or re-do). Patients were closely followed for a year and then contacted for long-term follow-up after a median of 53.00 months (IQR: 34.50 to 73.00). Statistical analyses of the outcome and predictors of AF recurrence were conducted. In 224 patients (53.98%) no evidence of AF recurrence could be found. LAVI differed significantly between the positive and adverse (AF recurrence) outcome group (49.96 vs 56.07 ml/m2, p < 0.001). Cox regression analyses revealed cCT LAVI (HR: 1.022, 95% CI: 1.013 to 1.031, p < 0.001), BMI (HR: 1.044, 95% CI: 1.005 to 1.084, p < 0.05) and the type of AF (HR: 1.838 for nonparoxysmal AF, 95% CI: 1.214 to 2.781, p < 0.01) to be effective predictors of AF recurrence. A prognostic cCT LAVI cut-off value of 51.99 ml/m2 was calculated and must be validated in future prospective studies. In conclusion, LAVI is an accurate, yet underutilized predictor of AF recurrence after pulmonary vein isolation with cryo-energy and scores for calculating AF recurrence or progression risks might underemphasize the importance of CT-derived LAVI as a predictive factor.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Function, Right/physiology , Cryosurgery/methods , Electrocardiography , Heart Atria/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Cardiac Volume , Female , Follow-Up Studies , Heart Atria/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...