Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1687: 463694, 2023 Jan 04.
Article in English | MEDLINE | ID: mdl-36502642

ABSTRACT

A simple and fast low-flow capillary electrophoresis-mass spectrometry (low-flow CE-MS) method has been developed to analyze oxidized 1-palmitoyl-2-arachidonoyl-sn-glycero-3-phosphocholine (ox-PAPC) products in human very low-density lipoproteins (VLDLs). Native PAPC standard was analyzed to optimize the low-flow CE-MS method. The optimal CE conditions included separation buffer (60% (v/v) acetonitrile, 40% (v/v) methanol, 0.1% (v/v) water, 0.5% (v/v) formic acid, 20 mM ammonium acetate), sheath liquid (60% (v/v) acetonitrile, 40% (v/v) methanol, 0.1% (v/v) water, 20 mM ammonium acetate), separation voltage (20 kV), separation capillary internal diameter (i.d.) (75 µm), separation capillary temperature (23˚C) and sample injection time (6 s). The selected MS conditions included heated capillary temperature (250°C), capillary voltage (10 V), and injection time (1 s). Sheath gas was not used in this study. The total ion chromatograms (TICs), extracted ion chromatograms (EICs) and MS spectra of native PAPC standard and its in vitro oxidation products showed good repeatability and sensitivity. To determine the ox-PAPC products in human VLDLs, the EICs and MS spectra of VLDLs were compared with the in vitro oxidation products of native PAPC standard. For native PAPC standard, the measured linear range was 2.5 - 100.0 µg/mL, and the coefficients of determination (R2) was 0.9994. The concentration limit of detection (LOD) was 0.44 µg/mL, and the concentration limit of quantitation (LOQ) was 1.34 µg/mL. A total of 21 ox-PAPC products were analyzed for the VLDLs of healthy and uremic subjects. The levels of 7 short-chain and 5 long-chain ox-PAPC products on uremic VLDLs were significantly higher than healthy VLDLs. This simple low-flow CE-MS method might be a good alternative for LC-MS for the analysis of ox-PAPC products. Furthermore, it might also help scientists to expedite the search for uremic biomarkers.


Subject(s)
Lipoproteins, VLDL , Methanol , Humans , Mass Spectrometry , Lipoproteins, LDL , Electrophoresis, Capillary
2.
Electrophoresis ; 41(15): 1333-1343, 2020 08.
Article in English | MEDLINE | ID: mdl-32390137

ABSTRACT

The apolipoproteins (APOs) of human very low-density lipoprotein (VLDL) were investigated by an optimized cyclodextrin-micellar electrokinetic chromatography (CD-MEKC) method. The separation buffer consisted of 20 mM sodium phosphate, 40 mM bile salts (50% sodium cholate and 50% sodium deoxycholate), 25 mM carboxymethyl-ß-cyclodextrin (CM-ß-CD) (pH 7.0). For CD-MEKC separation, a sample injection time of 12 s, a separation voltage of 15 KV, and a capillary temperature of 15°C were chosen. The optimal CD-MEKC method showed good resolution and repeatability for VLDL APOs. Identification and quantitation of VLDL APOs CI, CIII, and E were based on comparison with human APO standards. Good linear relationships with correlation coefficient (R2 ) 0.99 were obtained for APOs CI, CIII, and E standards. For these three APOs, the linear ranges were within 0.01-0.54 mg/mL, and the concentration limits of detection (LODs) were lower than 0.02 mg/mL. Moreover, VLDL APOs from four uremic patients and four healthy subjects were compared. The uremic and healthy CD-MEKC profiles showed dramatic difference. The levels of APO CIII were significantly higher for two patients, and the level of APO E was significantly higher for one patient. This study might be helpful for following the disease development of uremia and cardiovascular disease (CVD) in the future.


Subject(s)
Apolipoproteins , Chromatography, Micellar Electrokinetic Capillary/methods , Cyclodextrins/chemistry , Lipoproteins, VLDL , Apolipoproteins/blood , Apolipoproteins/chemistry , Humans , Limit of Detection , Linear Models , Lipoproteins, VLDL/blood , Lipoproteins, VLDL/chemistry , Uremia
SELECTION OF CITATIONS
SEARCH DETAIL
...