Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Ther Clin Risk Manag ; 20: 39-45, 2024.
Article in English | MEDLINE | ID: mdl-38344195

ABSTRACT

Background: Sharp esophageal foreign body (SEFB) impaction can cause varying degrees of damage to the esophagus. There are few studies analyzing the postoperative fasting time in SEFB patients. Methods: We retrospectively collected 835 SEFB patients. According to the fasting time after the endoscopic removal (ER) of SEFBs, the patients were divided into two groups: short fasting time (SFT, fasted ≤24 h) and long fasting time (LFT, fasted >24 h). Results: There were 216 and 619 patients in the SFT and LFT group, respectively. The average age of the SFT group (52.97 years) was younger than that of the LFT group (55.96 years) (p = 0.025). The LFT group had lower proportion of duration of impaction (DOI) within 12 hours (14.2% vs 22.2%, p = 0.006) and erosion rates (89.0% vs 94.0%, p = 0.034) as well as higher proportion of esophageal perforation (19.5 vs 6.5%, p = 0.010) and patients who got intravenous anesthesia (63.78% vs 31.9%, p = 0.000) than the SFT group. The longest diameter of the foreign body (Lmax) in the LFT group (2.60 ± 1.01 cm) was greater than that in the SFT group (2.41 ± 0.83 cm; p = 0.01). Multivariate regression analysis found that age (OR = 1.726[1.208-2.465], p = 0.003), DOI (OR = 1.793[1.175-2.737], p = 0.007), Lmax (OR = 1.477[1.033-2.111], p = 0.032), perforation (OR = 3.698[2.038-6.710]; p < 0.01) and intravenous anesthesia (OR = 3.734[2.642-5.278]; p < 0.01) were the independent factors that prolonged fasting time in patients with SEFBs, while esophageal mucosal erosion (OR = 0.433[0.229-0.820]; p = 0.01) was the influencing factor leading to shortened fasting time. Conclusion: For the first time, we analyzed factors influencing the fasting time after ER in SEFB patients. Age, DOI, Lmax, perforation and intravenous anesthesia were risk factors for a prolonged postoperative fasting time.

2.
Biomed Res Int ; 2021: 6752141, 2021.
Article in English | MEDLINE | ID: mdl-33521130

ABSTRACT

BACKGROUND: Thyroid cancer is the most common endocrine malignancy, with a recent global increase of 20% in age-related incidence. Ultrasonography and ultrasonography-guided fine-needle aspiration biopsy (FNAB) are the most widely used diagnostic tests for thyroid nodules; however, it is estimated that up to 25% of thyroid biopsies are cytologically inconclusive. Molecular markers can help guide patient-oriented and targeted treatment of thyroid nodules and thyroid cancer. METHODS: Datasets related to papillary thyroid cancer (PTC) or thyroid carcinoma (GSE129562, GSE3678, GSE54958, GSE138042, and GSE124653) were downloaded from the GEO database and analysed using the Limma package of R software. For functional enrichment analysis, the Kyoto Encyclopedia of Genes and Genomes pathway analysis and Gene Ontology were applied to differentially expressed genes (DEGs) using the Metascape website. A protein-protein interaction (PPI) network was built from the STRING database. Gene expression, protein expression, immunohistochemistry, and potential functional gene survival were analysed using the GEPIA website, the Human Protein Atlas website, and the UALCAN website. Potential target miRNAs were predicted using the miRDB and Starbase datasets. RESULTS: We found 219 upregulated and 310 downregulated DEGs, with a cut-off of p < 0.01 and ∣log FC | >1.5. The DEGs in papillary thyroid cancer were mainly enriched in extracellular structural organisation. At the intersection of the PPI network and Metascape MCODEs, the hub genes in common were identified as FN1, APOE, CLU, and SDC2. In the targeted regulation network of miRNA-mRNA, the hsa-miR-424-5p was found to synchronously modulate two hub genes. Survival analysis showed that patients with high expression of CLU and APOE had better prognosis. CONCLUSIONS: CLU and APOE are involved in the molecular mechanism of papillary thyroid cancer. The hsa-miR-424-5p might have the potential to reverse the processes of papillary thyroid cancer by modulating the hub genes. These are potential targets for the treatment of patients with papillary thyroid cancer.


Subject(s)
Gene Regulatory Networks , MicroRNAs/metabolism , RNA, Messenger/metabolism , Thyroid Cancer, Papillary/genetics , Thyroid Neoplasms/genetics , Thyroid Nodule/genetics , Apolipoproteins E/genetics , Biopsy , Biopsy, Fine-Needle , Cluster Analysis , Clusterin/genetics , Gene Expression Profiling , Gene Expression Regulation, Neoplastic , Humans , MicroRNAs/genetics , Oligonucleotide Array Sequence Analysis , Protein Interaction Mapping , Thyroid Cancer, Papillary/pathology , Thyroid Gland/pathology , Thyroid Neoplasms/pathology , Thyroid Nodule/pathology , Ultrasonography
3.
Interact Cardiovasc Thorac Surg ; 19(6): 938-45, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25183742

ABSTRACT

OBJECTIVES: The aim of the study was to detect whether the systolic dyssynchrony index (SDI) assessed by real-time 3D echocardiography (RT3DE) could predict clinical outcomes of patients with ventricular aneurysm in response to surgical ventricular reconstruction (SVR). METHODS: In total, 120 individuals underwent RT3DE, including 30 healthy volunteers and 90 patients with ventricular aneurysm. All patients underwent clinical and echocardiographic assessments at baseline and at 12 months after SVR. The SDI was defined as the SD of time to minimum systolic volume of the 16 left ventricular (LV) segments, expressed in percent RR duration. SVR responder was defined as a >15% decrease in LV end-systolic volume, reduction in NYHA functional class or 20% relative increase in the LV ejection fraction (LVEF). RESULTS: The SDI was significantly higher in patients with aneurysm, at 14.3% compared with 2.0% in healthy volunteers (P <0.047). The SDI was negatively correlated with the LVEF. After SVR, 86 patients were responders. In this patient subgroup, the SDI exhibited an immediate significant decrease (to 7.7%; P <0.034) and a progressive decrease during 12 months of follow-up (to 4.9%; P <0.044). The SDI can discriminate SVR responders. Receiver-operating characteristic curve analysis yielded cut-off values of SDI 14.3% best associated with SVR response; area under the curve was 0.79 with reduction in NYHA class, 0.86 with increase in EF and 0.66 with decrease in the end-systolic volume. CONCLUSIONS: RT3DE can be used to assess LV mechanical dyssynchrony in patients with aneurysm. SVR produces a mechanical intraventricular resynchronization and SDI can predict improvement following SVR.


Subject(s)
Cardiac Surgical Procedures , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Heart Aneurysm/surgery , Heart Ventricles/surgery , Plastic Surgery Procedures , Ventricular Dysfunction, Left/surgery , Ventricular Function, Left , Aged , Case-Control Studies , Female , Heart Aneurysm/diagnostic imaging , Heart Aneurysm/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Observer Variation , Pilot Projects , Predictive Value of Tests , Prospective Studies , Recovery of Function , Reproducibility of Results , Stroke Volume , Systole , Time Factors , Treatment Outcome , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology
4.
Sheng Li Xue Bao ; 66(2): 151-7, 2014 Apr 25.
Article in Chinese | MEDLINE | ID: mdl-24777405

ABSTRACT

The aim of the present study was to investigate the effect of precursor brain-derived neurotrophic factor (proBDNF) on survival and neurite outgrowth of cultured rat spiral ganglion neurons (SGNs). Spiral ganglions (SG) were collected from postnatal day 5 Sprague Dawley (SD) rats, then enzymatically digested and suspended. Dissociated SGNs were plated on poly-D-lysine/laminin coated eight-well chamber plates and maintained at 37 °C for 4 h to promote the attachment of the neurons. Cultured SGNs were randomly divided into five groups: control group, BDNF group (BDNF 10 ng/mL), C10 group (proBDNF 10 ng/mL), C50 group (proBDNF 50 ng/mL), and C100 group (proBDNF 100 ng/mL). All groups were incubated in a serum-free medium. 48 h after incubation, SGNs were fixed and stained for ßIII tubulin. Immunostaining of the cultured SGNs showed that, compared with the control group, the cellular survival of C50 group and C100 group were significantly reduced (P < 0.001). Furthermore, surviving numbers of the three proBDNF-treated groups were all lower than the BDNF group. In order to assess the effect of proBDNF on cell morphology, SGNs were divided into two categories: SGNs with or without neurites. The results demonstrated that proBDNF significantly increased the proportions of SGNs without neurites in C10, C50 and C100 groups compared with that in control group (P < 0.001). In addition, c-Jun N-terminal kinase (JNK) inhibitor, SP600125 (20 µmol/L) significantly increased the surviving number of SGNs in C50 group. These results suggest that proBDNF reduces the survival rate of cultured SGNs and inhibits the sprouting of neurites. Furthermore, the inhibition of JNK signaling attenuates the effect of proBDNF on SGNs survival.


Subject(s)
Brain-Derived Neurotrophic Factor/pharmacology , Neurons/cytology , Protein Precursors/pharmacology , Spiral Ganglion/cytology , Animals , Axons/physiology , Cell Survival , Cells, Cultured , JNK Mitogen-Activated Protein Kinases/antagonists & inhibitors , MAP Kinase Signaling System , Neurites/physiology , Rats , Rats, Sprague-Dawley
6.
Interact Cardiovasc Thorac Surg ; 17(6): 938-43, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24000314

ABSTRACT

OBJECTIVES: Intraoperative transit time flow measurement (TTFM) is widely used to assess anastomotic quality in coronary artery bypass grafting (CABG). However, in sequential vein grafting, the flow characteristics collected by the conventional TTFM method are usually associated with total graft flow and might not accurately indicate the quality of every distal anastomosis in a sequential graft. The purpose of our study was to examine a new TTFM method that could assess the quality of each distal anastomosis in a sequential graft more reliably than the conventional TTFM approach. METHODS: Two TTFM methods were tested in 84 patients who underwent sequential saphenous off-pump CABG in Beijing An Zhen Hospital between April and August 2012. In the conventional TTFM method, normal blood flow in the sequential graft was maintained during the measurement, and the flow probe was placed a few centimetres above the anastomosis to be evaluated. In the new method, blood flow in the sequential graft was temporarily reduced during the measurement by placing an atraumatic bulldog clamp at the graft a few centimetres distal to the anastomosis to be evaluated, while the position of the flow probe remained the same as in the conventional method. This new TTFM method was named the flow reduction TTFM. Graft flow parameters measured by both methods were compared. RESULTS: Compared with the conventional TTFM, the flow reduction TTFM resulted in significantly lower mean graft blood flow (P < 0.05); in contrast, yielded significantly higher pulsatility index (P < 0.05). Diastolic filling was not significantly different between the two methods and was >50% in both cases. Interestingly, the flow reduction TTFM identified two defective middle distal anastomoses that the conventional TTFM failed to detect. Graft flows near the defective distal anastomoses were improved substantially after revision. CONCLUSIONS: In this study, we found that temporary reduction of graft flow during TTFM seemed to enhance the sensitivity of TTFM to less-than-critical anastomotic defects in a sequential graft and to improve the overall accuracy of the intraoperative assessment of anastomotic quality in sequential vein grafting.


Subject(s)
Coronary Artery Bypass, Off-Pump , Rheology/methods , Saphenous Vein/transplantation , Aged , Anastomosis, Surgical , Blood Flow Velocity , China , Coronary Artery Bypass, Off-Pump/adverse effects , Female , Humans , Intraoperative Care , Male , Middle Aged , Predictive Value of Tests , Pulsatile Flow , Regional Blood Flow , Saphenous Vein/physiopathology , Time Factors , Treatment Outcome
7.
Can J Surg ; 56(2): 119-27, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23351499

ABSTRACT

BACKGROUND: In patients with coronary disease and aneurysm, ventricular reconstruction with revascularization is a surgical option. Details of patient selection and optimal surgical technique are still debated. We report our results with off-pump aneurysm plication after ventricular aneurysm with relative wall thinning. METHODS: We retrospectively reviewed the records of 248 patients who had an operation for postinfarction left ventricular aneurysm. Reconstruction was accomplished by off-pump anteroapical aneurysm plication. The following variables were recorded: preoperative clinical, angiographic and echocardiographic findings and operative procedures. Outcomes were early mortality, long-term survival and poor 5-year result, defined as the need for transplantation or repeated hospitalization for congestive heart failure. Risk factors were pinpointed using the t test and survival curves. Independent risk factors were identified using Cox regression methods. RESULTS: Hospital mortality was low (2.0%). Mean follow-up was 5.8 (standard deviation [SD] 3.8) years. Actuarial survival at 1 and 5 years was 94% and 84%. Among the 232 survivors, 200 were in functional class I or II, and the average increase in ejection fraction was 14.0% (SD 3.1%). As determined by multivariable analysis, factors predicting poor outcome were advanced age, ejection fraction less than 0.35, conicity index less than 1, end-systolic volume index greater than 80 mL/m2, advanced New York Heart Association functional class and congestive heart failure. CONCLUSION: Using wall thinning as a criterion for patient selection, the technique of off-pump anteroapical aneurysm plication can be performed with low operative mortality and provides good symptomatic relief and long-term survival.


Subject(s)
Heart Aneurysm/surgery , Aged , Cardiac Surgical Procedures , Coronary Artery Bypass, Off-Pump , Female , Heart Aneurysm/etiology , Heart Aneurysm/pathology , Heart Ventricles , Hospital Mortality , Hospitalization , Humans , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/complications , Retrospective Studies , Risk Factors , Stroke Volume , Treatment Outcome
8.
Chin Med J (Engl) ; 125(21): 3844-50, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23106886

ABSTRACT

BACKGROUND: Transcatheter closure of patent ductus arteriosus (PDA) is a well established procedure and an accepted treatment modality for small to moderate-sized PDA. This study aimed to evaluate the immediate and follow-up results of transcatheter closure of large PDAs with severe pulmonary arterial hypertension (PAH) in adults. METHODS: After a complete hemodynamic evaluation differentiating from the reversibility of severe PAH, transcatheter closure of PDA was performed. Patients were followed up clinically and echocardiographically at 24 hours, 1 month, 3 months, 6 months, 12 months and 24 months after occlusion. RESULTS: Twenty-nine patients had successful occlusion, pulmonary artery pressure (PAP), left ventricular ejection fraction (LVEF) and fractional shortening (FS) significantly decreased immediately after occlusion ((106 ± 25) mmHg vs. (50 ± 14) mmHg, P < 0.01; (63.7 ± 7.2)% vs. (51.4 ± 10.1)%, P < 0.01 and (36.9 ± 8.2)% vs. (28.9 ± 8.6)%, P < 0.05, respectively). At 1 month after PDA closure, the signs and symptoms improved markedly in all 29 patients, and PDAs were completely closed and remained closed during the follow-up. Eighteen patients having different degrees of dyspnea were treated with angiotensin converting enzyme inhibitor (ACEI) and/or digoxin after occlusion. Nine patients whose pulmonary vascular resistence (PVR) > 6 Wood units accepted targeted PAH therapy. After 1 to 3 months of peroral drug therapy, their exercise tolerance improved from New York Heart Association (NYHA) class III-IV to NYHA class I. During follow-up, no latent arrhythmias were found, the left atrial diameter (LAD), left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), left ventricular mass index (LVMI) and pulmonary artery systolic pressure (PASP) decreased significantly (P < 0.05), and FS and LVEF recovered compared to the immediate postclosure state. However, FS and LVEF remained low compared to the preclosure state. CONCLUSIONS: Transcatheter closure of large PDA with severe PAH is feasible, effective, and safe in adults. Significant left ventricular systolic changes may occur after closure of large PDA, and left ventricular function usually recovers within a few months.


Subject(s)
Ductus Arteriosus, Patent/surgery , Hypertension, Pulmonary/physiopathology , Adolescent , Adult , Ductus Arteriosus, Patent/physiopathology , Familial Primary Pulmonary Hypertension , Female , Follow-Up Studies , Humans , Male , Middle Aged , Vascular Resistance , Ventricular Function, Left , Ventricular Remodeling
9.
Chin Med J (Engl) ; 125(18): 3228-35, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22964314

ABSTRACT

BACKGROUND: The temporal response to off-pump anteroapical aneurysm plication has not been well defined. We have evaluated the long-term clinical and functional results of this technique and compared the efficacy with the patch modeling repair. METHODS: From March 2005 to May 2010, 163 (115 men and 48 women) consecutive patients were operated on for post-infarction left ventricular aneurysm (LVA), 54 patients underwent patch remodeling (group A) and 109 patients underwent off-pump anteroapical aneurysm plication repair (group B). All patients had simultaneous coronary revascularization, other operative procedures included septoplasty in eight and ablation of ventricular tachycardia in six. Follow-up ranged from 1 to 5 years, short-term and mid-term outcomes, including complications, cardiac function, and mortality, were assessed. RESULTS: Early mortality was 1.8% for all patients (group A 1 death vs. group B 2 deaths, not significant (NS)). Peri-operative support included intraaortic balloon pumping in 16 (9.8%), (group A 6 patients vs. group B 10 patients, NS) and inotropic drugs in 84 (51.5%), (group A 34 vs. group B 50, NS). During a mean follow-up of (3.7±0.8) years, eight patients died, with four due to cardiac-related causes. No patient required transplantation, and two required use of an implantable cardioverter-defibrillator for ventricular tachycardia. Survival at 1 and 5 years was 95% and 86%, respectively. It did not differ significantly between group A and group B. Functional class improved from 2.90 ± 0.59 to 1.65 ± 0.54 among the mid-term survivors (P < 0.001), with no significant difference between the two groups. Pre-operative risk factors for mortality or poor function were ejection fraction (EF) < 0.35 (OR = 7.9, 95%CI 1.6 - 40.0); congestive heart failure (CHF) (OR = 4.4, 95%CI 1.0 - 19.0); end-systolic volume index (ESVI) > 80 ml/m(2) (OR = 3.7, 95%CI 1.0 - 14.0); and advanced age > 70 years (OR = 2.4, 95%CI 1.0 - 12.0). CONCLUSIONS: The technique of off-pump anteroapical aneurysm plication associated with coronary grafting can be performed with low operative mortality, providing good symptomatic relief and long-term survival, and similar results can be achieved with patch modeling repair.


Subject(s)
Cardiac Surgical Procedures/methods , Heart Aneurysm/surgery , Myocardial Infarction/surgery , Aged , Coronary Artery Bypass , Echocardiography , Female , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors
10.
Chin Med J (Engl) ; 125(7): 1242-8, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22613595

ABSTRACT

BACKGROUND: Left ventricular (LV) dyssynchrony has been described to occur in patients with myocardial infarction. Dyssynchrony of left ventricular mechanical contraction produces adverse hemodynamic consequences. This study aimed to test the capacity of geometric rebuilding by aneurysm plication to restore a more synchronous contractile pattern after a mechanical, rather than electrical, intervention. METHODS: A total of sixty patients with anterior myocardial infarction, QRS duration < 120 ms, electively undergoing operation between January 2008 and January 2010 were included for analysis. Real-time 3-dimensional echocardiography was performed to assess LV function, LV systolic and diastolic dyssynchrony by measuring ejection fraction (EF), peak ejection rate (PER), peak filling rate (PFR) and LV dyssynchrony. LV dyssynchrony was defined as the systolic dyssynchrony of the time to reach the minimum systolic volume for 16 LV segments, expressed in percent cardiac cycle, systolic dyssynchrony index (SDI). We compared changes of LV dyssynchrony at different interval times. RESULTS: LV contraction was significantly asynchronous because preoperative SDI was higher, EF, PER and PFR were lowered. Compared with function after operation, LV mechanical intraventricular resynchronization was improved with decreased SDI ((8.7 ± 0.5)% vs. (14.3 ± 1.6)%, P = 0.01); LV function was improved with EF increasing ((43 ± 9)% vs. (37 ± 7)%, P = 0.001), and LV systolic and diastolic dyssynchrony was improved with more rapid PFR (199.4 ± 15.6 vs. 148.4 ± 21.2, P = 0.002) and PER (212.4 ± 14.5 vs. 156.3 ± 26.2, P = 0.001). CONCLUSIONS: Systolic and diastolic dyssynchrony was highly prevalent in patients with aneurysm, irrespective of QRS duration. Aneurysm plication produces a mechanical intraventricular resynchronization.


Subject(s)
Aneurysm/surgery , Myocardial Infarction/surgery , Aged , Echocardiography, Three-Dimensional , Female , Humans , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Radiography
11.
Circ J ; 75(8): 1867-71, 2011.
Article in English | MEDLINE | ID: mdl-21617325

ABSTRACT

BACKGROUND: The aim of the present study was to assess immediate and long-term clinical outcome of Chinese patent foramen ovale (PFO) patients with paradoxical embolism who underwent transcatheter PFO closure. METHODS AND RESULTS: One hundred and ninety-two patients underwent transcatheter PFO closure for secondary prevention of thromboembolic events (TE). During the procedure, 7 patients had frequent atrial premature beats or transient atrial tachycardia in implantation and 1 patient had a transitory ST-elevation in leads II, III and aV(F). These complications converted spontaneously after a few minutes. No cases of procedure-related death or TE were observed during hospitalization. Minor adverse events, including chest discomfort (11%), palpitations (25%) and dyspnea (1%) were reported within 1 month of the procedure. These symptoms had disappeared in most patients by 6-month follow-up. One patient had a new occurrence of migraine at 27 months after the implantation. Within a median follow-up of 49 ± 8 months, no residual shunt of the atrial level was identified and correct positioning of the device was confirmed on transthoracic echocardiography in all patients. No death related to any cause or recurrent TE were recorded. CONCLUSIONS: Transcatheter PFO closure is a minimally invasive procedure with a high success rate, low complication rate and an excellent long-term outcome, and appears to be a wise approach for secondary prevention of recurrent embolic events in symptomatic patients.


Subject(s)
Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Embolism, Paradoxical/therapy , Foramen Ovale, Patent/therapy , Foramen Ovale , Adult , Cardiac Catheterization/adverse effects , Female , Follow-Up Studies , Humans , Male , Middle Aged
12.
Chin Med J (Engl) ; 124(4): 618-21, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21362292

ABSTRACT

We report a case of acute left ventricular failure at one hour after transcatheter closure of a secundum atrial septal defect (ASD) in a 28-year-old man with hypertrophic cardiomyopathy. Afforded noninvasive mechanical ventilation and the administration of intravenous morphine and high doses of furosemide, the patient exhibited improvement of his clinical condition, reduction of pulmonary congestion at chest X-ray, and satisfactory blood gas analyses in twelve hours. Twenty-four hours later, the patient received oral administration of furosemide and metoprolol. After 7 days the patient was discharged in good clinical condition. At follow-up at 12 months, the patient had remained symptomatically improved from NYHA Class III symptoms before the procedure to Class II symptoms. There was no latent arrhythmia at the follow-up examination. Follow-up transthoracic echocardiography estimated an improvement of the left ventricular function. So, transcatheter closure of a secundum ASD in a patient with hypertrophic cardiomyopathy is feasible, and a thorough understanding of the hemodynamic condition of ASD and hypertrophic cardiomyopathy will reduce the complication of ASD closure.


Subject(s)
Cardiac Catheterization , Cardiomyopathy, Hypertrophic/therapy , Heart Failure/diagnosis , Heart Septal Defects, Atrial/therapy , Adult , Cardiomyopathy, Hypertrophic/physiopathology , Echocardiography , Heart Failure/pathology , Heart Septal Defects, Atrial/physiopathology , Humans , Male , Ventricular Function, Left
13.
Zhonghua Xin Xue Guan Bing Za Zhi ; 39(1): 65-8, 2011 Jan.
Article in Chinese | MEDLINE | ID: mdl-21418801

ABSTRACT

OBJECTIVE: To investigate the immediately effects of inhaled aerosolized iloprost in adult patients with severe pulmonary arterial hypertension (PAH) secondary to congenital heart diseases (CHD). METHODS: Adult patients with severe PAH secondary to CHD (n = 165) were included in this study. Right heart catheterization was performed, Pulmonary and systemic blood flow, the oxygen consumption VO(2) (ml/min) were calculated using Fick's principle. Pulmonary vascular resistances (PVR) were calculated with standard formulas and indexed to body surface area. Hemodynamic parameters were measured before and after iloprost inhalation (20 µg). RESULTS: Post iloprost inhalation, heart rate, mean aortic pressure, pulmonary systolic pressure to aortic systolic pressure ratio all remained un changed (P > 0.05), while pulmonary artery pressure (PAP) were significantly reduced and Qp significantly increased from (7.2 ± 4.8) L/min to (9.9 ± 7.2) L/min (P < 0.01), PVR was also significantly reduced from (13.4 ± 8.7) Wood units to (9.5 ± 6.6) Wood units (P < 0.01), and left-to-right shunt volume increased from (3.2 ± 4.4) L/min to (5.5 ± 7.0) L/min (P < 0.01) and right-to-left shunt volume decreased from (1.0 ± 1.0) L/min to (0.7 ± 0.7) L/min (P < 0.01). Subgroup analysis showed that adult patients with patent ductus arteriosus and/or ventricular septal defects are more likely to develop severe pulmonary arterial hypertension or Eisenmenger syndrome than patients with atrial septal defects. CONCLUSIONS: Inhaled Aerosolised iloprost use is effective and safe for adult patients with severe pulmonary arterial hypertension secondary to congenital heart diseases.


Subject(s)
Heart Defects, Congenital/drug therapy , Hypertension, Pulmonary/drug therapy , Iloprost/therapeutic use , Administration, Inhalation , Adolescent , Adult , Female , Heart Defects, Congenital/complications , Humans , Hypertension, Pulmonary/complications , Iloprost/pharmacology , Male , Vascular Resistance , Young Adult
14.
Nan Fang Yi Ke Da Xue Xue Bao ; 30(5): 1163-4, 2010 May.
Article in Chinese | MEDLINE | ID: mdl-20501422

ABSTRACT

OBJECTIVE: To explore the possibility and reliability of echocardiography in quantitative evaluation of pulmonary blood flow in patients with congenital heart disease (CHD). METHODS: Sixty-four patients with left to right shunt congenital atrial septal defect (ASD) underwent echocardiographic examinations of the right upper and lower pulmonary vein blood flow spectrum in the four-chamber face, and the right upper pulmonary vein flow velocity time integral (VTIrupv) and right inferior pulmonary venous flow velocity time integral (VTIrlpv) were calculated according to the heart rate. The VTIrupv and VTIrlpv were compared with the pulmonary blood flow (Qp) calculated by Fick method with right heart catheterization. RESULTS: There was a high correlation between the right lung vein flow velocity time integral measured by the catheter of transthoracic echocardiography and Qp. CONCLUSION: The pulmonary venous flow spectrum measured by echocardiography can be informative of the pulmonary blood flow in patients with CHD. Echocardiography may serve as a potential noninvasive technique to evaluate pulmonary blood flow in these patients.


Subject(s)
Echocardiography, Doppler, Color , Heart Defects, Congenital/physiopathology , Lung/blood supply , Adolescent , Adult , Aged , Female , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnostic imaging , Humans , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/physiopathology , Male , Middle Aged , Regional Blood Flow , Young Adult
15.
Chin Med J (Engl) ; 123(7): 834-7, 2010 Apr 05.
Article in English | MEDLINE | ID: mdl-20497673

ABSTRACT

BACKGROUND: Transcatheter closure of patent foramen ovale (PFO) is a promising alternative to surgical closure or anticoagulation therapy to prevent paradoxical embolic events in patients with PFO. Several different devices have been used for transcatheter PFO closure. The aim of the present study was to evaluate the safety and feasibility for closure of PFO with a new PFO occluder, the Spider PFO occluder. METHODS: The device was implanted in the PFO patients under fluoroscopy and transthoracic echocardiography (TTE) using a 10 French delivery sheath employing a femoral vein approach. Aspirin was administered at 100 mg/d for six months after occlusion. The clinical and echocardiographic follow-up of patients were performed at the 24th hour, 1st month, 3rd month, 6th month, and 12th month after occlusion, and yearly thereafter. RESULTS: The device was implanted successfully in all 55 patients. No major complications occurred during the perioperative period, such as thromboembolism, occluder dislodgement, infection or myocardial infarction. No residual shunt of the atrial level was shown by transesophageal echocardiography, and no latent arrhythmia or cerebral vessel events occurred in any cases during follow-up ((35 +/- 9) months, range 6 - 51 months). CONCLUSION: Transcatheter closure of a PFO with the Spider PFO occluder is a safe and effective therapeutic option for the secondary prevention of presumed paradoxical embolism. However, randomized trials comparing this device with other devices and therapies have to be performed.


Subject(s)
Cardiac Catheterization/methods , Foramen Ovale, Patent/therapy , Adolescent , Adult , Aged , Aspirin/therapeutic use , Echocardiography , Female , Humans , Male , Middle Aged , Young Adult
16.
Nan Fang Yi Ke Da Xue Xue Bao ; 29(11): 2269-72, 2009 Nov.
Article in Chinese | MEDLINE | ID: mdl-19923085

ABSTRACT

OBJECTIVE: To summarize the echocardiographic features of a wide spectrum of congenital mitral valve anomalies. METHODS: The medical records, echocardiograms, cardiac catheterization studies, and surgical reports were reviewed. The mitral valve anomalies evaluated in the study included parachute mitral valve, double orifice mitral valve, congenital mitral stenosis with 2 papillary muscles, anomalous papillary muscle rotation, and 3 commissures and papillary muscles in 15 cases. Surgeries were performed in 11 patients, and 1 patient underwent transcatheter closure of the patent ductus arteriosus. RESULTS: The echocardiograms of 6 cases of parachute mitral valve were characterized by a hypoplastic mitral valve with short chordal attachments to a single posterior medial papillary muscle. The mitral valve demonstrated restricted motion. The double orifice mitral valve were featured by two separate mitral valve orifice, with each suborifice supported by its own tension apparatus in 4 patients. Asymmetric hypoplastic mitral valve stenosis with two papillary muscles was found in 1 patient with short and unbalanced chordal attachments to the anterior lateral major papillary muscle. Anomalous papillary muscle rotation was found in 1 patient. Mirtal anomaly with 3 major commissures and 3 papillary muscles was found in 3 patients. CONCLUSIONS: Echocardiography offers clear demonstration of the mitral valve thickness and chordal attachments, and allows visualization of the position and the number of the papillary muscles and interpapillary spaces for evaluation of the mobility of the valve leaflets, therefore can be a valuable diagnostic modality for congenital mitral valve anomalies, especially congenital mitral stenosis.


Subject(s)
Mitral Valve Stenosis/diagnostic imaging , Mitral Valve/abnormalities , Mitral Valve/diagnostic imaging , Adolescent , Adult , Child , Child, Preschool , Echocardiography, Doppler, Color , Female , Humans , Infant , Middle Aged , Mitral Valve Stenosis/congenital , Papillary Muscles/abnormalities , Papillary Muscles/diagnostic imaging , Young Adult
17.
Zhonghua Wai Ke Za Zhi ; 47(16): 1236-8, 2009 Aug 15.
Article in Chinese | MEDLINE | ID: mdl-19781171

ABSTRACT

OBJECTIVE: To study the clinical results of mitral valve repair in patients of primary infective endocarditis with mitral insufficiency. METHODS: From January 2004 to July 2007, 40 patients who had undergone valve repair procedure for infective endocarditis with mitral insufficiency were analyzed retrospectively. There were 26 male and 14 female patients, with an average age of (34.0 +/- 3.5) years old, including 6 patients of underlying heart disease, 34 patients of no previously underlying heart disease. There were 12 patients in NYHA functional class II, 19 patients in class III, 9 patients in class IV preoperatively. Preoperative echocardiography showed moderate to severe MR in all patients. The surgery was performed under extracorporeal circulation and moderate hypothermia. The distribution of anatomical lesion according to surgical findings were vegetation in 32 patients, leaflet prolapsed in 34 patients, leaflet perforation in 16 patients, chordal rupture in 32 patients, and annular abscess in 2 patients. The vegetations and infected tissues were debrided. The surgery consisted of complex methods to repair mitral valve, including direction leaflet closure in 5 patients, pericardial patch closure of leaflet perforation in 18 patients, chords reimplantation in 4 patients and chords transference in 6 patients, quadrangular resection in 12 patients, double orifice method in 17, closure of the commissure in 8, rings annuloplasty in 28 cases, and so on. There were 28 selective surgeries and 12 emergent ones. Patients were evaluated for early and long-term clinic and echocardiographic outcome before and after operation. RESULTS: There were no early postoperative death. Mitral valve repair was feasible in 39 patients, one patient was transformed to mitral valve replacement during the operation. Postoperative echocardiography demonstrated no (n = 24) or mild (n = 15) mitral regurgitation at the discharge examination and observed significant reductions in left ventricular end diastolic [from (62 +/- 7) mm to (51 +/- 6) mm, P < 0.05] and end systolic dimensions [from (45 +/- 3) mm to (40 +/- 4) mm, P < 0.05] and left atrial dimensions [from (49 +/- 4) mm to (42 +/- 6) mm, P < 0.05]. Mean follow-up (25.6 +/- 3.2) months, freedom from recurrent moderate to severe MR, freedom from repeat operation or infective endocarditis, revealed patients were 36 cases in NYHY class I, 3 cases in class II. CONCLUSION: Mitral valve repair for mitral valve endocarditis is feasible with a satisfied clinical outcome, maintains valve competency with significant reductions in left atrial and left ventricular dimensions after surgery.


Subject(s)
Endocarditis/complications , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Adolescent , Adult , Child , Female , Follow-Up Studies , Heart Valve Prosthesis Implantation , Humans , Male , Middle Aged , Mitral Valve Insufficiency/etiology , Retrospective Studies , Treatment Outcome , Young Adult
18.
Nan Fang Yi Ke Da Xue Xue Bao ; 29(2): 323-5, 2009 Feb.
Article in Chinese | MEDLINE | ID: mdl-19246313

ABSTRACT

OBJECTIVE: To determine the anatomical variation and classification of ventricular septal defect (VSD) using echocardiography for percutaneous catheter closure in eligible cases. METHOD: The isolated ventricular septal defect was diagnosed with echocardiography in 240 patients , and 167 patients screened by transthoracic echocardiography were suitable for percutaneous catheter closure, but only 62 with isolated perimembranous VSD voluntarily received the procedure. RESULTS: The procedure was successful in 58 patients, with a success rate of 93.5% with Amplatzer device. The diameter of VSD ranged from 2.4 to 13.9 (mean 5.3-/+2.0) mm with echocardiography, and the size of Amplatzer device ranged from 4-18 (mean 8.3-/+2.9) mm. Perimembranous ventricular septal defect was complicated by aneurysm formation in 22 patients. Residual trivial or mild shunt was seen in seven (12%) patients at 24 h and one (1.7%) patient at 3 months. Seven (12.1%) patients developed heart block, 3 (5.2%) had intermittence and transient complete heart block, and one had transient second degree atrioventricular block disappearing in 3 to 10 days, and 3 (5.2%) patients had complete right bundle branch block lasting for one month. None of the patients developed significant aortic regurgitation (P>0.05), although 22 showed a superior margin of the defect less than 3 mm from the aortic valve. The mean distance from the aortic valve was 3.7-/+2.7 (1.0 to 10.5) mm. No significant mitral and tricuspid regurgitation occurred in these patients. Four patients had unsuccessful procedures. CONCLUSIONS: Percutaneous closure with Amplatzer device can be carried out successfully in a majority of suitable defects screened using transthoracic echocardiography. Echocardiography can exactly demonstrate the anatomical variation and classification of ventricular septal defect in adults. Attention should be given to the misdiagnosis by echocardiography of a doubly committed defect as a perimembranous outflow defect. Heart block can be an important complication of the procedure.


Subject(s)
Balloon Occlusion/methods , Cardiac Catheterization/methods , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/therapy , Septal Occluder Device , Adolescent , Adult , Aged , Balloon Occlusion/instrumentation , Child , Child, Preschool , Echocardiography/methods , Female , Heart Septal Defects, Ventricular/classification , Humans , Male , Middle Aged , Prosthesis Implantation/methods , Young Adult
19.
Zhonghua Xin Xue Guan Bing Za Zhi ; 37(10): 936-8, 2009 Oct.
Article in Chinese | MEDLINE | ID: mdl-20137548

ABSTRACT

OBJECTIVE: To evaluate the efficacy and safety of domestic left-disk-coated atrial septal occluder on treating patent foramen ovale in a miniswine model. METHODS: Foramen ovale was punctured in 12 Guangxi BA-MA miniswine and occluded by domestic left-disk-coated atrial septal occluder (Spider(TM) PFO closure system) under the guidance of fluoroscopy. After occlusion, miniswine were executed after transthoracic echocardiography examination with color Doppler at month 1, 2, 3 and 6 respectively for gross inspection and microscopic examinations. RESULTS: There were no vegetation, thrombosis, broken stent, or erosion on the surface of all devices. The PFOs were completed occluded as evidenced by transthoracic echocardiography at 1 to 6 months after operation. The surface of the device was fully covered by collagen tissue and endothelial tissue at 1 month after operation and the thickened gradually thereafter. CONCLUSIONS: The domestic left-disk-coated atrial septal occluder can efficiently occlude patent foramen ovale. Satisfactory biocompatibility, rapid and complete endothelium covering and low incidence of complication are also evidenced for this closure system in our experiment.


Subject(s)
Cardiac Catheterization/instrumentation , Foramen Ovale, Patent/therapy , Animals , Swine , Swine, Miniature
20.
Zhonghua Xin Xue Guan Bing Za Zhi ; 37(12): 1132-5, 2009 Dec.
Article in Chinese | MEDLINE | ID: mdl-20193187

ABSTRACT

OBJECTIVE: To investigate the safety and efficacy of patent foramen ovale (PFO) closure with Left-disk-coated PFO occluder. METHODS: The device was implanted in patients with PFO under the guidance of fluoroscopy and transthoracal echocardiography using a 10-12 French delivery sheath via femoral vein approach. Aspirin (100 mg/d for 6 months) was administered post procedure. Patients were followed clinically and echocardiographically at 24 hours, 1 month, 3 months, 6 months, and 12 months after device implantation and yearly thereafter. RESULTS: Permanent device implantation failed in one patient (4%) and succeed in the remaining 24 patients (96%). There were no major in-hospital-adverse events or complications (thromboembolism, occluder dislodgement, infection or myocardial infarction). Seven patients developed transient atrial premature beats or atrial tachycardia during implantation and stopped without medication post procedure. Follow-up [(25 + or - 12) months] results showed that all occluders were in position and there were no residual shunt, arrhythmia and cerebral vessel events post procedure. CONCLUSION: Left-disk-coated PFO occluder is safe and effective for PFO closure.


Subject(s)
Cardiac Catheterization/methods , Foramen Ovale, Patent/therapy , Adolescent , Adult , Female , Follow-Up Studies , Humans , Male , Middle Aged , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...