Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Biomedicines ; 12(4)2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38672081

ABSTRACT

BACKGROUND: Efforts to identify therapies to treat hospitalised patients with COVID-19 are being continued. Alkaline phosphatase (AP) dephosphorylates pro-inflammatory adenosine triphosphate (ATP) into anti-inflammatory adenosine. METHODS: In a randomised controlled trial, we investigated the safety and efficacy of AP in patients with SARS-CoV-2 infection admitted to the ICU. AP or a placebo was administered for four days following admission to the ICU. The primary outcome was the duration of mechanical ventilation. Mortality in 28 days, acute kidney injury, need for reintubation, safety, and inflammatory markers relevant to the described high cytokine release associated with SARS-CoV-2 infection were the secondary outcomes. RESULTS: Between December 2020 and March 2022, 97 patients (of the intended 132) were included, of which 51 were randomised to AP. The trial was terminated prematurely based on meeting the threshold for futility. Compared to the placebo, AP did not affect the duration of mechanical ventilation (9.0 days vs. 9.3 days, p = 1.0). No safety issues were observed. After 28 days, mortality was 9 (18%) in the AP group versus 6 (13%) in the placebo group (p = 0.531). Additionally, no statistically significant differences between the AP and the placebo were observed for the other secondary outcomes. CONCLUSIONS: Alkaline phosphatase (AP) therapy in COVID-19 ICU patients showed no significant benefits in this trial.

2.
Clin Chem Lab Med ; 61(8): 1436-1445, 2023 07 26.
Article in English | MEDLINE | ID: mdl-36877870

ABSTRACT

OBJECTIVES: Hormone measurements using automated immunoassays (IAs) can be affected by the sample matrix. Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is less affected by these matrix effects. In clinical laboratories, testosterone, cortisol and, free thyroxine (FT4) are often measured using IAs. Renal failure alters serum composition in blood samples from people undergoing hemodialysis (HDp) and have, therefore, a complex serum constitution compared to healthy controls (HC). The goal of this study was to investigate the accuracy of testosterone, cortisol, and FT4 measurements in samples of HDp and to get more insight in the interfering factors. METHODS: Thirty serum samples from HDp and HC were collected to measure testosterone, cortisol, and FT4 using a well standardized isotope dilution (ID)-LC-MS/MS method and 5 commercially available automated IAs (Alinity, Atellica, Cobas, Lumipulse, UniCel DXI). Method comparisons between LC-MS/MS and IAs were performed using both HDp and HC samples. RESULTS: Average bias from the LC-MS/MS was for testosterone, cortisol, and FT4 immunoassays respectively up to 92, 7-47 and 16-27% more in HDp than in HC samples and was IA dependent. FT4 IA results were falsely decreased in HDp samples, whereas cortisol and testosterone concentrations in females were predominantly falsely increased. Correlation coefficients between LC-MS/MS and IA results were lower in HDp compared to HC samples. CONCLUSIONS: Several IAs for testosterone (in women), cortisol, and FT4 are less reliable in the altered serum matrix of samples of HDp than in HC. Medical and laboratory specialists should be aware of these pitfalls in this specific population.


Subject(s)
Hydrocortisone , Testosterone , Humans , Female , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Immunoassay/methods , Renal Dialysis
3.
Eur Thyroid J ; 11(6)2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36219545

ABSTRACT

Objective: Thyroid hormone measurements are often performed in pregnant women, as hypo- and hyperthyroidism during pregnancy can severely affect the fetus. Serum free thyroxine (fT4) measurements are well known for their analytical challenges, due to low serum concentrations and the subtle equilibrium between free and bound T4 (to thyroid-binding globulin (TBG), transthyretin and albumin). Pregnant women have high TBG concentrations due to an increase in human chorionic gonadotropin (hCG) and estrogen and lower albumin concentrations which change the equilibrium and may affect the validity of fT4 measurements in their samples. As accurate serum fT4 measurements in pregnant women are important for the long-term health of the fetus, we aimed to evaluate the accuracy of several fT4 immunoassays in the serum of pregnant women. Methods: FT4 was measured in healthy controls and pregnant women using a candidate-reference method (LC-MS/MS) and five commercially available automated immunoassays (Alinity (Abbott), Atellica (Siemens), Cobas (Roche), Lumipulse (Fujirebio) and UniCel DXI (Beckman Coulter)). Method comparisons (Bland Altman plots and Passing and Bablok analyses) were performed. Results: Serum samples from both healthy controls (n = 30) and pregnant women (n = 30; mean gestational age, 24.8 weeks) were collected. The fT4 immunoassays deviated +7 to +29% more from the LC-MS/MS in serum samples of pregnant women than healthy controls (falsely high). Conclusions: Our results indicate that immunoassays overestimate fT4 in pregnant women, which might lead to an overestimation of thyroid status. Physicians and laboratory specialists should be aware of this phenomenon to avoid drawing false conclusions about thyroid function in pregnant women.

4.
Clin Chem Lab Med ; 60(10): 1661-1668, 2022 09 27.
Article in English | MEDLINE | ID: mdl-35918785

ABSTRACT

OBJECTIVES: Testosterone testing is relevant for evaluating castration adequacy and diagnosis of castration-resistant prostate cancer (PCa). However, the recommended testosterone cut-off of 1.7 nmol/L (50 ng/dL) to define adequate castration is based on consensus and not validated for the automated immunoassays (AIA) used in today's medical laboratories. Furthermore, appropriate population intervals have not been determined by a state-of-the-art assay. We investigated the analytical suitability of this cut-off and the accuracy of the present-day AIAs for testosterone analysis in castrated PCa patients. METHODS: Leftover serum from 120 PCa patients castrated with luteinizing hormone-releasing hormone agonists was analysed for testosterone by five methods: Architect i2000 (Abbott), Access (Beckman), Cobas 6000 (Roche), Atellica (Siemens), LC-MS/MS. For all assays, the castration 95th, 97.5th and 99th percentile upper limits were determined. Furthermore, Passing-Bablok regression, mean bias and Spearman's correlation coefficients were compared to the LC-MS/MS method and total error based on biological variation. RESULTS: All castration upper limits, ranging from 0.472 nmol/L (LC-MS/MS) to 1.25 nmol/L (Access) (95% percentile), were significantly lower than the current castration cut-off (1.7 nmol/L). Slopes of Passing-Bablok regressions comparing the AIA with the LC-MS/MS method ranged from 1.4 (Cobas and Atellica) to 3.8 (Access). The Architect showed the highest correlation with LC-MS/MS (ρ=0.58). All AIA failed to meet the desirable total error criterion. CONCLUSIONS: These results suggest that a lower general testosterone castration cut-off may be more appropriate in evaluating the adequacy of castration in PCa and that present-day AIA lack analytical accuracy to quantify testosterone levels in castrated PCa.


Subject(s)
Prostatic Neoplasms , Testosterone , Castration , Chromatography, Liquid , Humans , Immunoassay , Male , Tandem Mass Spectrometry
SELECTION OF CITATIONS
SEARCH DETAIL
...