Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Infect Dis ; 22(1): 960, 2022 Dec 26.
Article in English | MEDLINE | ID: mdl-36572861

ABSTRACT

BACKGROUND: In fall 2020 when schools in the Netherlands operated under a limited set of COVID-19 measures, we conducted outbreaks studies in four secondary schools to gain insight in the level of school transmission and the role of SARS-CoV-2 transmission via air and surfaces. METHODS: Outbreak studies were performed between 11 November and 15 December 2020 when the wild-type variant of SARS-CoV-2 was dominant. Clusters of SARS-CoV-2 infections within schools were identified through a prospective school surveillance study. All school contacts of cluster cases, irrespective of symptoms, were invited for PCR testing twice within 48 h and 4-7 days later. Combined NTS and saliva samples were collected at each time point along with data on recent exposure and symptoms. Surface and active air samples were collected in the school environment. All samples were PCR-tested and sequenced when possible. RESULTS: Out of 263 sampled school contacts, 24 tested SARS-CoV-2 positive (secondary attack rate 9.1%), of which 62% remained asymptomatic and 42% had a weakly positive test result. Phylogenetic analysis on 12 subjects from 2 schools indicated a cluster of 8 and 2 secondary cases, respectively, but also other distinct strains within outbreaks. Of 51 collected air and 53 surface samples, none were SARS-CoV-2 positive. CONCLUSION: Our study confirmed within school SARS-CoV-2 transmission and substantial silent circulation, but also multiple introductions in some cases. Absence of air or surface contamination suggests environmental contamination is not widespread during school outbreaks.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/epidemiology , Prospective Studies , Netherlands/epidemiology , Phylogeny , Disease Outbreaks , Schools
2.
BMJ ; 374: n1676, 2021 Jul 27.
Article in English | MEDLINE | ID: mdl-34315770

ABSTRACT

OBJECTIVE: To assess the diagnostic test accuracy of two rapid antigen tests in asymptomatic and presymptomatic close contacts of people with SARS-CoV-2 infection on day 5 after exposure. DESIGN: Prospective cross sectional study. SETTING: Four public health service covid-19 test sites in the Netherlands. PARTICIPANTS: 4274 consecutively included close contacts (identified through test-and-trace programme or contact tracing app) aged 16 years or older and asymptomatic for covid-19 when requesting a test. MAIN OUTCOME MEASURES: Sensitivity, specificity, and positive and negative predictive values of Veritor System (Beckton Dickinson) and Biosensor (Roche Diagnostics) rapid antigen tests, with reverse-transcriptase polymerase chain reaction (RT-PCR) testing as reference standard. The viral load cut-off above which 95% of people with a positive RT-PCR test result were virus culture positive was used as a proxy of infectiousness. RESULTS: Of 2678 participants tested with Veritor, 233 (8.7%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 149 were also detected by the rapid antigen test (sensitivity 63.9%, 95% confidence interval 57.4% to 70.1%). Of 1596 participants tested with Biosensor, 132 (8.3%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 83 were detected by the rapid antigen test (sensitivity 62.9%, 54.0% to 71.1%). In those who were still asymptomatic at the time of sampling, sensitivity was 58.7% (51.1% to 66.0%) for Veritor (n=2317) and 59.4% (49.2% to 69.1%) for Biosensor (n=1414), and in those who developed symptoms were 84.2% (68.7% to 94.0%; n=219) for Veritor and 73.3% (54.1% to 87.7%; n=158) for Biosensor. When a viral load cut-off was applied for infectiouness (≥5.2 log10 SARS-CoV-2 E gene copies/mL), the overall sensitivity was 90.1% (84.2% to 94.4%) for Veritor and 86.8% (78.1% to 93.0%) for Biosensor, and 88.1% (80.5% to 93.5%) for Veritor and 85.1% (74.3% to 92.6%) for Biosensor, among those who remained asymptomatic throughout. Specificities were >99%, and positive and negative predictive values were >90% and >95%, for both rapid antigen tests in all analyses. CONCLUSIONS: The sensitivities of both rapid antigen tests in asymptomatic and presymptomatic close contacts tested on day 5 onwards after close contact with an index case were more than 60%, increasing to more than 85% after a viral load cut-off was applied as a proxy for infectiousness.

3.
Microbiol Resour Announc ; 8(15)2019 Apr 11.
Article in English | MEDLINE | ID: mdl-30975805

ABSTRACT

We report the complete genome sequences of eight human parainfluenza viruses (HPIV) belonging to Human respirovirus 1 (HPIV-1), Human respirovirus 3 (HPIV-3), Human rubulavirus 2 (HPIV-2), and Human rubulavirus 4 (HPIV-4). The genome sequences were generated using random-primed next-generation sequencing and represent the first HPIV full-genome sequences from the Netherlands.

4.
Stud Health Technol Inform ; 224: 61-6, 2016.
Article in English | MEDLINE | ID: mdl-27225554

ABSTRACT

Global healthcare systems are struggling with the enormous burden associated with infectious diseases, as well as the incessant rise of antimicrobial resistance. In order to adequately address these issues, there is an urgent need for rapid and accurate infectious disease diagnostics. The H2020 project DIAGORAS aims at diagnosing oral and respiratory tract infections using a fully integrated, automated and user-friendly platform for physicians' offices, schools, elderly care units, community settings, etc. Oral diseases (periodontitis, dental caries) will be detected via multiplexed, quantitative analysis of salivary markers (bacterial DNA and host response proteins) for early prevention and personalised monitoring. Respiratory Tract Infections will be diagnosed by means of DNA/RNA differentiation so as to identify their bacterial or viral nature. Together with antibiotic resistance screening on the same platform, a more efficient treatment management is expected at the point-of-care. At the heart of DIAGORAS lies a centrifugal microfluidic platform (LabDisk and associated processing device) integrating all components and assays for a fully automated analysis. The project involves an interface with a clinical algorithm for the comprehensive presentation of results to end-users, thereby increasing the platform's clinical utility. DIAGORAS' performance will be validated at clinical settings and compared with gold standards.


Subject(s)
Dental Caries/diagnosis , Drug Resistance, Bacterial , Periodontitis/diagnosis , Respiratory Tract Infections/diagnosis , Automation, Laboratory , Centrifugation/methods , DNA, Bacterial/analysis , Humans , Microfluidic Analytical Techniques , Periodontitis/microbiology , Precision Medicine/methods , RNA, Viral/analysis , Respiratory Tract Infections/microbiology , Respiratory Tract Infections/virology , Saliva/immunology , Saliva/microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...