Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Feline Med Surg ; 24(10): 1039-1045, 2022 10.
Article in English | MEDLINE | ID: mdl-34904481

ABSTRACT

OBJECTIVES: The aim of this study was to determine the feasibility of ultrasonographically measuring the caudal vena cava (CVC) at the subxiphoid view of healthy, lightly sedated cats in a standing position and lateral recumbency. METHODS: This was a prospective, observational, experimental single-centre study. Twenty healthy research-purposed cats were enrolled. Two trained operators scanned each cat in two positions - standing and lateral recumbency - in a randomised order. CVC diameter was measured at the narrowest diameter during inspiration and at the widest diameter during expiration, at two anatomical locations along the CVC - where the CVC crosses the diaphragm (base) and 2 mm caudal to the diaphragm. The CVC collapsibility index (CVC-CI) was calculated for each site. Normalcy was assessed with a Shapiro-Wilk test. A one-way ANOVA with post-hoc Tukey's test was used to compare inspiratory with expiratory values within and between groups. A paired t-test compared the CVC-CI between groups (P ⩽0.05 indicated statistical significance). Spearman's correlation and Bland-Altman analysis assessed inter-operator variability. RESULTS: All ultrasonographic data passed normalcy and were reported as mean ± SD. When compared with each other, inspiratory and expiratory values were statistically different for position, location and operator (all P <0.0001). There was no statistically significant difference between lateral recumbency or standing position for inspiratory, expiratory and CVC-CI values. Inter-operator variability was substantial, with operator 2 consistently obtaining smaller measurements than operator 1. The mean CVC-CI in lateral recumbency at the base was 24% for operator 1 and 37% for operator 2. For the same site in standing position, CVC-CI was 27% and 41% for operators 1 and 2, respectively. CONCLUSIONS AND RELEVANCE: This pilot study demonstrates that it is possible to ultrasonographically measure the CVC diameter in both lateral recumbency and a standing position in healthy, lightly sedated cats. However, measurements obtained are operator dependent with variability between individuals. Further studies are needed to determine if ultrasonographic CVC assessment will prove helpful in estimating intravascular volume status in cats.


Subject(s)
Standing Position , Vena Cava, Inferior , Animals , Cats , Pilot Projects , Prospective Studies , Thorax , Vena Cava, Inferior/diagnostic imaging
2.
Carcinogenesis ; 36 Suppl 1: S38-60, 2015 Jun.
Article in English | MEDLINE | ID: mdl-26106143

ABSTRACT

The aim of this work is to review current knowledge relating the established cancer hallmark, sustained cell proliferation to the existence of chemicals present as low dose mixtures in the environment. Normal cell proliferation is under tight control, i.e. cells respond to a signal to proliferate, and although most cells continue to proliferate into adult life, the multiplication ceases once the stimulatory signal disappears or if the cells are exposed to growth inhibitory signals. Under such circumstances, normal cells remain quiescent until they are stimulated to resume further proliferation. In contrast, tumour cells are unable to halt proliferation, either when subjected to growth inhibitory signals or in the absence of growth stimulatory signals. Environmental chemicals with carcinogenic potential may cause sustained cell proliferation by interfering with some cell proliferation control mechanisms committing cells to an indefinite proliferative span.


Subject(s)
Carcinogens, Environmental/adverse effects , Cell Proliferation/drug effects , Environmental Exposure/adverse effects , Hazardous Substances/adverse effects , Neoplasms/chemically induced , Neoplasms/etiology , Signal Transduction/drug effects , Animals , Humans
SELECTION OF CITATIONS
SEARCH DETAIL