Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
J Clin Med ; 12(14)2023 Jul 22.
Article in English | MEDLINE | ID: mdl-37510956

ABSTRACT

BACKGROUND: The impact of concomitant coronary artery bypass grafting (CABG) on aortic valve replacement (AVR) in octogenarians is still debated. We analyzed the characteristics and long-term survival of octogenarians undergoing isolated AVR and AVR + CABG. METHODS: All octogenarians who consecutively underwent AVR with or without concomitant CABG at our tertiary cardiac center between 2000 and 2022 were included. Patients with redo, emergent, or any other concomitant procedures were excluded. The primary endpoints were 30-day and long-term survival. The secondary endpoints were early postoperative outcomes and determinants of long-term survival. Univariable and multivariable logistic regression analyses were performed to identify independent predictors of 30-day mortality, and Cox regression analysis was performed for predictors of adverse long-term survival. RESULTS: A total of 1011 patients who underwent AVR (83.0 [81.0-85.0] years, 42.0% males) and 1055 with AVR + CABG (83.0 [81.2-85.4] years, 66.1% males) were included in our study. Survival at 30 days and at 1, 3, and 5 years in the AVR group was 97.9%, 91.5%, 80.5%, and 66.2%, respectively, while in the AVR + CABG group it was 96.2%, 89.6%, 77.7%, and 64.7%, respectively. There was no significant difference in median postoperative survival between the AVR and AVR + CABG groups (7.1 years [IQR: 6.7-7.5] vs. 6.6 years [IQR: 6.3-7.2], respectively, p = 0.21). Significant predictors of adverse long-term survival in the AVR group included age (hazard ratio (HR): 1.09; 95% CI: 1.06-1.12, p < 0.001), previous MI (HR: 2.08; 95% CI: 1.32-3.28, p = 0.002), and chronic kidney disease (HR 2.07; 95% CI: 1.33-3.23, p = 0.001), while in the AVR + CABG group they included age (HR: 1.06; 95% CI: 1.04-1.10, p < 0.001) and diabetes mellitus (HR: 1.48; 95% CI: 1.15-1.89, p = 0.002). Concomitant CABG was not an independent risk factor for adverse long-term survival (HR: 0.89; 95% CI: 0.77-1.02, p = 0.09). CONCLUSIONS: The long-term survival of octogenarians who underwent AVR or AVR + CABG was similar and was not affected by adding concomitant CABG. However, octogenarians who underwent concomitant CABG with AVR had significantly higher in-hospital mortality. Each decision should be discussed within the heart team.

2.
Trauma Case Rep ; 46: 100868, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37347006

ABSTRACT

Case: A 61-year-old male construction worker was admitted to our Emergency Department due to being impaled in the chest after fall onto the long pole of his cement mixer. He was promptly scanned through the CT then transferred to theatre where unique technique for intubation was utilised prior to performing a Video Assisted Thoracoscopic Surgery exploration and extraction of the foreign object. Discussion: Impalement injuries are classified into Types I or II depending on the direction of movement of the human body in relation to the foreign object. There currently is no consensus on the best management of chest wall injuries involving impalements. Our case utilised Video Assisted Thoracoscopic Surgery as the dominant method of intervention together with highly skilled anaesthetic preparation. Conclusion: The combined expert anaesthetic and surgical approach utilised collectively had a role in ensuring the best possible outcome for the patient.

4.
Asian Cardiovasc Thorac Ann ; 30(7): 788-796, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35469437

ABSTRACT

BACKGROUND: The aim of this study was to evaluate early- and mid-term results of our actual practice embedding redo aortic valve replacement and transcatheter procedures for aortic bioprosthetic failure. METHODS: Data for aortic valve reinterventions (redo surgical aortic valve replacement, isolated redo aortic valve replacement, and valve-in-valve transcatheter aortic valve implantation, transcatheter valve-in-valve procedure) were collected (2010-2019). Logistic regression analysis was performed to identify predictors favouring the choice of transcatheter against redo surgery. Cox analysis was used to study the association of preoperative variables with survival. Survival probabilities were calculated with Kaplan-Meier analysis and compared using a log-rank test. RESULTS: A total of 125 patients were included (redo surgical aortic valve replacement: 84 patients, valve-in-valve transcatheter aortic valve implantation: 41 patients). Median age was 74 [63-80] years, 58% of the patients were male and the median logistic EuroSCORE was 15 [8-26] %. There was no early mortality. Eighteen patients (redo surgical aortic valve replacement: 15, valve-in-valve transcatheter aortic valve implantation: 3) sustained at least one postoperative complication. At pre-discharge transthoracic echocardiogram, valve-in-valve transcatheter aortic valve implantation had significantly higher trans-prosthetic gradients (mean gradient: valve-in-valve transcatheter aortic valve implantation 18 mmHg vs. redo surgical aortic valve replacement 14 mmHg, p < 0.001). Overall survival probabilities were 94% and 73% at 1 year and 5 years, respectively. Previous coronary artery bypass surgery operation and age were independently associated with lower survival probabilities during the follow-up. CONCLUSIONS: Redo surgical aortic valve replacement and valve-in-valve transcatheter aortic valve implantation are both safe and effective for aortic bioprosthetic failure. Further valve-in-valve data are needed to determine the haemodynamic performance of transcatheter prostheses and its impact on long-term outcomes.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Male , Prosthesis Failure , Reoperation , Risk Factors , Treatment Outcome
5.
J Cardiothorac Surg ; 16(1): 223, 2021 Aug 06.
Article in English | MEDLINE | ID: mdl-34362403

ABSTRACT

AIMS: A review was conducted on the composition, advantages and limitations of available aortic valve prototypes to create an ideal valve for percutaneous implantation. Patients Patients with multiple comorbidities who cannot withstand the risks of open cardiac surgery. METHODOLOGY: The search was performed using online databases and textbooks. Articles were excluded based on specific criterion. RESULTS: Ten prototypes created between 2006 and 2019 were found and reviewed. The prototypes had a set of advantages and limitations with their characteristics coinciding at times. CONCLUSIONS: The ideal percutaneously implantable aortic valve should have minimum coaptation height, zero folds in the leaflets, minimum valve height, minimum leaflet flexion and three leaflets. It can be composed of biological or synthetic material, as long as it provides minimal risk of thrombosis. However, more studies are needed to ensure other ideal parameters.


Subject(s)
Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aortic Valve/surgery , Humans
SELECTION OF CITATIONS
SEARCH DETAIL