Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
Radiol Imaging Cancer ; 6(4): e230186, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38847615

ABSTRACT

Purpose To develop a molecular breast imaging (MBI)-guided biopsy system using dual-detector MBI and to perform initial testing in participants. Materials and Methods The Stereo Navigator MBI Accessory biopsy system comprises a lower detector, upper fenestrated compression paddle, and upper detector. The upper detector retracts, allowing craniocaudal, oblique, or medial or lateral biopsy approaches. The compression paddle allows insertion of a needle guide and needle. Lesion depth is calculated by triangulation of lesion location on the upper detector at 0° and 15° and relative lesion activity on upper and lower detectors. In a prospective study (July 2022-June 2023), participants with Breast Imaging Reporting and Data System category 2, 3, 4, or 5 breast lesions underwent MBI-guided biopsy. After injection of 740 MBq technetium 99m sestamibi, craniocaudal and mediolateral oblique MBI (2-minute acquisition per view) confirmed lesion visualization. A region of interest over the lesion permitted depth calculation in the system software. Upper detector retraction allowed biopsy device placement. Specimen images were obtained on the retracted upper detector, confirming sampling of the target. Results Of 21 participants enrolled (mean age, 50.6 years ± 10.1 [SD]; 21 [100%] women), 17 underwent MBI-guided biopsy with concordant pathology. No lesion was observed at the time of biopsy in four participants. Average lesion size was 17 mm (range, 6-38 mm). Average procedure time, including preprocedure imaging, was 55 minutes ± 13 (range, 38-90 minutes). Pathology results included invasive ductal carcinoma (n = 1), fibroadenoma (n = 4), pseudoangiomatous stromal hyperplasia (n = 6), and fibrocystic changes (n = 6). Conclusion MBI-guided biopsy using a dual-head system with retractable upper detector head was feasible, well tolerated, and efficient. Keywords: Breast Biopsy, Molecular Breast Imaging, Image-guided Biopsy, Molecular Breast Imaging-guided Biopsy, Breast Cancer Clinical trial registration no. NCT06058650 © RSNA, 2024.


Subject(s)
Breast Neoplasms , Image-Guided Biopsy , Molecular Imaging , Technetium Tc 99m Sestamibi , Humans , Female , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Middle Aged , Prospective Studies , Image-Guided Biopsy/methods , Image-Guided Biopsy/instrumentation , Adult , Molecular Imaging/methods , Molecular Imaging/instrumentation , Aged , Radiopharmaceuticals , Breast/diagnostic imaging
2.
J Nucl Med Technol ; 52(2): 107-114, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38839120

ABSTRACT

Molecular breast imaging (MBI) is one of several options available to patients seeking supplemental screening due to mammographically dense breasts. Patient experience during MBI may influence willingness to undergo the test but has yet to be formally assessed. We aimed to assess patient comfort level during MBI, to compare MBI comfort with mammography comfort, to identify factors associated with MBI discomfort, and to evaluate patients' willingness to return for future MBI. Methods: A 10-question survey was sent by e-mail to patients undergoing MBI between August and December 2022 to obtain quantitative assessments and qualitative opinions about MBI. Results: Of 561 invited patients, 209 (37%) completed the survey and provided study consent. Their average age was 60.1 y (range, 40-81 y). Of the 209 responders, 202 (97%) were presenting for screening MBI, 195 (94%) had dense breasts, and 46 (22%) had a personal history of breast cancer. The average rating of MBI comfort was 2.9 (SD, 1.5; median, 3.0) on a 7-point scale (1 indicating extremely comfortable and 7 indicating extremely uncomfortable). The rating distribution was as follows: 140 (67%) comfortable (rating, 1-3); 24 (12%) neither comfortable nor uncomfortable (rating, 4); and 45 (22%) uncomfortable (rating, 5 or 6). No responders gave a 7 rating. The most frequently mentioned sources of discomfort included breast compression (n = 16), back or neck discomfort (n = 14), and maintaining position during the examination (n = 14). MBI comfort was associated with responder age (74% ≥55 y old were comfortable, versus 53% <55 y old [P = 0.003]) and history of MBI (71% with prior MBI were comfortable, versus 61% having a first MBI [P = 0.006]). Of 208 responders with a prior mammogram, 148 (71%) said MBI is more comfortable than mammography (a significant majority [P < 0.001]). Of 202 responders to the question of whether they were willing to return for a future MBI, 196 (97%) were willing. A notable factor in positive patient experience was interaction with the MBI nuclear medicine technologist. Conclusion: Most responders thought MBI to be a comfortable examination and more comfortable than mammography. Patient experience during MBI may be improved by ensuring back support and soliciting patient feedback at the time of positioning and throughout the examination. Methods under study to reduce imaging time may be most important for improving patient experience.


Subject(s)
Molecular Imaging , Humans , Middle Aged , Aged , Adult , Female , Surveys and Questionnaires , Aged, 80 and over , Molecular Imaging/methods , Breast Neoplasms/diagnostic imaging , Mammography
3.
AJR Am J Roentgenol ; 220(1): 40-48, 2023 01.
Article in English | MEDLINE | ID: mdl-35856455

ABSTRACT

BACKGROUND. Molecular breast imaging (MBI) is used for various breast imaging indications. An MBI lexicon has been developed, although the likelihood of malignancy of the lexicon descriptors has not been assessed to our knowledge. OBJECTIVE. The purpose of this article was to evaluate the PPV for malignancy of the MBI lexicon imaging descriptors. METHODS. This retrospective study included MBI examinations performed from August 1, 2005, through August 31, 2017, that were positive (BI-RADS analogous categories 0, 3, 4, 5, or 6) according to the clinical report and had an available reference standard. Examinations were performed using dual-detector cadmium zinc telluride MBI systems after injection of 99mTc sestamibi. Category 3 lesions had pathologic correlation, at least 2 years of imaging follow-up, or final resolution on follow-up imaging as category 1 or 2; category 4 and 5 lesions had pathologic correlation. MBI examinations were reviewed by one of two radiologists to assess lesions on the basis of the published MBI lexicon for type (mass vs nonmass uptake), distribution (if nonmass uptake), uptake intensity, and number of MBI views on which the lesion was seen. PPV for malignancy was summarized. RESULTS. The analysis included 643 lesions (479 benign, 164 malignant; 83 mass, 560 nonmass uptake) in 509 patients (median age, 56 years). PPV was 73.5% (61/83) for masses and 18.4% (103/560) for nonmass uptake. Among the nonmass uptake lesions, PPV was 36.2% (17/47) for segmental, 20.1% (77/384) for focal, 30.8% (4/13) for diffuse, and 4.3% (5/116) for regional or multiple regional distribution. PPV was 5.3% (5/94) for one view, 15.2% (32/210) for two views, 14.6% (13/89) for three views, and 45.4% (113/249) for four views showing the lesion. PPV was 14.0% (43/307) for mild, 22.4% (51/228) for moderate, and 64.8% (70/108) for marked uptake intensity. CONCLUSION. The MBI lexicon lesion descriptors are associated with likelihood of malignancy. PPV was higher for masses, lesions seen on multiple MBI views, and lesions with marked uptake intensity. Among nonmass uptake lesions, PPV was highest for those with segmental distribution. CLINICAL IMPACT. Insight into the likelihood of malignancy associated with the MBI lexicon descriptors can inform radiologists' interpretations and guide potential future incorporation of the MBI lexicon into the ACR BI-RADS Atlas.


Subject(s)
Breast Neoplasms , Mammography , Humans , Middle Aged , Female , Retrospective Studies , Mammography/methods , Probability , Radionuclide Imaging , Physical Examination , Breast Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods
4.
J Breast Imaging ; 5(3): 240-247, 2023 May 22.
Article in English | MEDLINE | ID: mdl-38416886

ABSTRACT

Early detection of breast cancer through screening mammography saves lives. However, the sensitivity of mammography for breast cancer detection is reduced in women with dense breast tissue. Imaging modalities for supplemental breast cancer screening include MRI, whole breast US, contrast-enhanced mammography, and molecular breast imaging (MBI). Molecular breast imaging with 99mTc-sestamibi is a functional imaging test to identify metabolically active areas in the breast with positioning analogous to mammography. Since 2011, there have been six large, published studies of screening MBI as a supplement to mammography involving over 6000 women from four different institutions. A multicenter, prospective clinical trial of 3000 women comparing breast cancer detection using screening digital breast tomosynthesis alone or in combination with MBI recently completed enrollment. This review focuses on the current evidence of MBI use for supplemental breast cancer screening, the strengths and limitations of MBI, and recent technological advances.


Subject(s)
Breast Neoplasms , Female , Humans , Breast Neoplasms/diagnosis , Mammography/methods , Breast Density , Prospective Studies , Early Detection of Cancer/methods , Multicenter Studies as Topic
6.
J Breast Imaging ; 4(1): 61-69, 2022 Jan 27.
Article in English | MEDLINE | ID: mdl-38422417

ABSTRACT

To facilitate the delivery of accurate and timely care to patients in complex environments, process improvement methodologies such as Lean can be very effective. Lean is a quality improvement methodology that seeks to add value for patients and employees by continuously improving processes and eliminating waste. At our institution, Lean principles were applied to improve efficiency and minimize waste in the diagnostic breast imaging reading room. This paper describes how we applied Lean principles, including plan-do-study-act testing, level-loading (heijunka), and visual management, to level the workload of the diagnostic radiologists in our practice. Implementation of these principles to improve the diagnostic workflow in breast imaging is described along with examples from our practice, including challenges and future opportunities.

7.
Clin Cancer Res ; 27(17): 4696-4699, 2021 09 01.
Article in English | MEDLINE | ID: mdl-34078650

ABSTRACT

PURPOSE: Patient-derived xenografts (PDX) are a research tool for studying cancer biology and drug response phenotypes. While engraftment rates are higher for tumors with more aggressive characteristics, it is uncertain whether engraftment is prognostic for cancer recurrence. PATIENTS AND METHODS: In a prospective study of patients with breast cancer treated with neoadjuvant chemotherapy (NAC) with taxane ± trastuzumab followed by anthracycline-based chemotherapy, we report the association between breast cancer events and PDX engraftment using tumors derived from treatment naïve (pre-NAC biopsies from 113 patients) and treatment resistant (post-NAC at surgery from 34 patients). Gray test was used to assess whether the cumulative incidence of a breast cancer event differs with respect to either pre-NAC PDX engraftment or post-NAC PDX engraftment. RESULTS: With a median follow-up of 5.7 years, the cumulative incidence of breast cancer relapse did not differ significantly according to pre-NAC PDX engraftment (5-year rate: 13.6% vs. 13.4%; P = 0.89). However, the incidence of a breast event was greater for patients with post-NAC PDX engraftment (5-year rate: 50.0% vs. 19.6%), but this did not achieve significance (P = 0.11). CONCLUSIONS: In treatment-naïve breast cancer receiving standard NAC, PDX engraftment was not prognostic for breast cancer recurrence. Further study is needed to establish whether PDX engraftment in the treatment-resistant setting is prognostic for cancer recurrence.


Subject(s)
Breast Neoplasms/drug therapy , Neoadjuvant Therapy , Transplantation, Heterologous , Xenograft Model Antitumor Assays , Animals , Breast Neoplasms/surgery , Female , Humans , Mice , Prospective Studies , Treatment Outcome
9.
Clin Imaging ; 76: 26-29, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33548889

ABSTRACT

OBJECTIVE: Document occurrence of breast cancer in females after liver, kidney, or pancreas transplantation seen at a tertiary medical center. METHODS: Medical records of adult female patients with liver, kidney, or pancreas transplants from 1/1/1995 to 4/4/2014 were retrospectively reviewed. Patients with a history of breast cancer, no mammogram post-transplant, or no research authorization were excluded. Mammogram findings and pathology results were reviewed and recorded. Cancer rates could not be measured in patients followed up outside the institution. Descriptive statistics summarized the cohort. Occurrence rates were estimated using Poisson regression. RESULTS: 1095 women were included and 33 were diagnosed with breast cancer post-transplant. Median age at diagnosis was 58 years. Average interval from transplant to cancer diagnosis was 82.6 months. Observed occurrence of invasive and in-situ breast cancer (reported as per 100,000 person-years [95% confidence interval]) was 353 [243-496]. Liver transplant patients showed the lowest rate (181 [95% CI 73-372]), vs. kidney (476 [305-708]) or pancreas (467 [57-1688]). Patients with the highest breast density showed increased occurrence despite younger age (1001 [367-2178]) compared to those with lower breast density (range 239 [109-454] to 372 [186-666]). CONCLUSIONS: Female patients after organ transplant experienced increased breast cancer occurrence in this observational study. Those who developed breast cancer also had increased breast density. The findings underscore the importance of breast cancer screening in this population.


Subject(s)
Breast Neoplasms , Breast Density , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/epidemiology , Early Detection of Cancer , Female , Humans , Mammography , Middle Aged , Retrospective Studies
10.
Acad Radiol ; 28(5): 726-732, 2021 05.
Article in English | MEDLINE | ID: mdl-32773330

ABSTRACT

RATIONALE AND OBJECTIVES: We analyzed multi-institutional data to determine if Step 3 performance tiers can identify radiology residents with increased risk of Core examination failure and submean performance. MATERIALS AND METHODS: We collected Step 3 scores (USMLE Step 3 or COMLEX Level 3) and American Board of Radiology (ABR) Core examination outcomes and scores for anonymized residents from 13 different Diagnostic Radiology residency programs taking the ABR Core examination between 2013 and 2019. Step 3 scores were converted to percentiles based on Z-score, with Core outcome and performance analyzed for Step 3 groups based on 50th percentile and based on quintiles. Core outcome was scored as fail when conditionally passed or failed. Core performance was measured by the percent of residents with scores below the mean. Differences between Step 3 groups for Core outcome and Core performance were statistically evaluated. RESULTS: Data were available for 342 residents. The Core examination failure rate for 121 residents with Step 3 scores <50th percentile was 19.8% (fail relative risk = 2.26), significantly higher than the 2.7% failure rate for the 221 other residents. Of 42 residents with Step 3 scores in the lowest quintile, the Core failure rate increased to 31.0% (fail relative risk = 3.52). Core performance improved with higher Step 3 quintiles. CONCLUSION: Step 3 licensing scores have value in predicting radiology resident performance on the ABR Core examination, enabling residency programs to target higher risk residents for early assessment and intervention.


Subject(s)
Internship and Residency , Radiology , Educational Measurement , Humans , Radiography , Radiology/education , Retrospective Studies , United States
11.
J Breast Imaging ; 3(4): 416-426, 2021 Aug 12.
Article in English | MEDLINE | ID: mdl-38424795

ABSTRACT

Molecular breast imaging (MBI) is a nuclear medicine technique that has evolved considerably over the past two decades. Technical advances have allowed reductions in administered doses to the point that they are now acceptable for screening. The most common radiotracer used in MBI, 99mTc-sestamibi, has a long history of safe use. Biopsy capability has become available in recent years, with early clinical experience demonstrating technically successful biopsies of MBI-detected lesions. MBI has been shown to be an effective supplemental screening tool in women with dense breasts and is also utilized for breast cancer staging, assessment of response to neoadjuvant chemotherapy, problem solving, and as an alternative to breast MRI in women who have a contraindication to MRI. The degree of background parenchymal uptake on MBI shows promise as a tool for breast cancer risk stratification. Radiologist interpretation is guided by a validated MBI lexicon that mirrors the BI-RADS lexicon. With short interpretation times, a fast learning curve for radiologists, and a substantially lower cost than breast MRI, MBI provides many benefits in the practices in which it is utilized. This review will discuss the current state of MBI technology, clinical applications of MBI, MBI interpretation, radiation dose associated with MBI, and the future of MBI.

12.
J Breast Imaging ; 3(1): 113-123, 2021 Jan 26.
Article in English | MEDLINE | ID: mdl-38424840

ABSTRACT

Clinically, acute mastitis presents as a red, swollen, and painful breast. Targeted ultrasound can be performed to evaluate the extent of infection and for an underlying abscess. Noncomplicated mastitis or a small fluid collection may respond to oral antibiotics without further intervention, but a larger or more complex abscess may require single or serial percutaneous aspiration. Breast infections, particularly those complicated by an abscess, can have a prolonged clinical course, and close follow-up is required. Since the clinical presentation and imaging features of acute infectious mastitis can overlap with other etiologies, such as inflammatory breast cancer and idiopathic granulomatous mastitis, a percutaneous biopsy may be indicated to accurately diagnose patients.

13.
J Am Coll Radiol ; 17(12): 1663-1669, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32479797

ABSTRACT

PURPOSE: We analyzed multi-institutional data to understand the relationship of ACR Diagnostic Radiology In-Training Examination (DXIT) scores to ABR Core examination performance. METHODS: We collected DXIT rank scores and ABR Core examination outcomes and scores for anonymized residents from 12 different diagnostic radiology residency programs taking the ABR Core examination between 2013 and 2019. DXIT scores were grouped into quintiles based on rank score for residency year 1 (R1), residency year 2 (R2), and residency year 3 (R3) residents. Core outcome was scored as fail when conditionally passed or failed. Core performance was grouped using SD from the mean and measured by the percent of residents with scores below the mean. Differences between DXIT score quintiles for Core outcome and Core performance were statistically evaluated. RESULTS: DXIT and Core outcome data were available for 446 residents. The Core examination failure rate for the lowest quintile R1, R2, and R3 DXIT scores was 20.3%, 34.2%, and 38.0%, respectively. Core performance improved with higher R3 DXIT quintiles. Only 2 of 229 residents with R3 DXIT score ≥ 50th percentile failed the Core examination, with both failing residents having R2 DXIT scores in the lowest quintile. CONCLUSIONS: DXIT scores are useful evaluation metrics to identify a subgroup of residents at significantly higher risk for Core examination failure and another subgroup of residents at significantly lower risk for Core examination failure, with increasing predictive power with advancing residency year. These scores enable identification of approximately one-half of R3 residents whose risk of Core examination failure is negligible.


Subject(s)
Internship and Residency , Radiology , Benchmarking , Educational Measurement , Radiography , Radiology/education , United States
14.
AJR Am J Roentgenol ; 215(2): 277-284, 2020 08.
Article in English | MEDLINE | ID: mdl-32551908

ABSTRACT

OBJECTIVE. The purpose of this article is to review clinical uses and image interpretation of molecular breast imaging (MBI) and clarify radiation risks. CONCLUSION. MBI detects additional cancers compared with conventional imaging in women with dense breasts and those with elevated risk of breast cancer. Its role as an imaging biomarker of cancer risk and in assessing neoadjuvant chemotherapy response is growing. Radiation risk is minimal; benefit-to-risk ratio is similar to that of mammography. MBI is low cost, well tolerated, and easily adapted into clinical practice.


Subject(s)
Breast Density , Breast Neoplasms/diagnostic imaging , Molecular Imaging , Female , Humans , Radiation Injuries/epidemiology , Risk Assessment
16.
AJR Am J Roentgenol ; 214(1): 185-193, 2020 01.
Article in English | MEDLINE | ID: mdl-31593516

ABSTRACT

OBJECTIVE. The purpose of this study was to determine whether application of a proprietary image-processing algorithm would allow a reduction in the necessary administered activity for molecular breast imaging (MBI) examinations. MATERIALS AND METHODS. Images from standard-dose MBI examinations (300 MBq 99mTc-sestamibi) of 50 subjects were analyzed. The images were acquired in dynamic mode and showed at least one breast lesion. Half-dose MBI examinations were simulated by summing one-half of the dynamic frames and were processed with the algorithm under study in both a default and a preferred filter mode. Two breast radiologists independently completed a set of two-alternative forced-choice tasks to compare lesion conspicuity on standard-dose images, half-dose images, and the algorithm-processed half-dose images in both modes. RESULTS. Relative to the standard-dose images, the half-dose images were preferred in 4, the default-filtered half-dose images in 50, and preferred-filtered half-dose images in 76 of 100 readings. Compared with standard-dose images, in terms of lesion conspicuity, the half-dose images were rated better in 2, equivalent in 6, and poorer in 92 of 100 readings. The default-filtered half-dose images were rated better, equivalent, or poorer in 13, 73, and 14 of 100 readings. The preferred-filtered half-dose images were rated as better, equivalent, or poorer in 55, 34, and 11 of 100 readings. CONCLUSION. Compared with that on standard-dose images, lesion conspicuity on images obtained with the algorithm and acquired at one-half the standard dose was equivalent or better without compromise of image quality. The algorithm can also be used to decrease imaging time with a resulting increase in patient comfort and throughput.


Subject(s)
Algorithms , Breast Diseases/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Image Processing, Computer-Assisted , Molecular Imaging/methods , Radiation Dosage , Aged , Female , Humans , Middle Aged , Radionuclide Imaging
18.
AJR Am J Roentgenol ; 213(4): 932-943, 2019 10.
Article in English | MEDLINE | ID: mdl-31166752

ABSTRACT

OBJECTIVE. The purpose of this study is to prospectively compare the size of invasive breast cancer before and after neoadjuvant chemotherapy (NAC) at breast MRI and molecular breast imaging (MBI) and to assess the accuracy of post-NAC MBI and MRI relative to pathologic analysis. SUBJECTS AND METHODS. Women with invasive breast cancer greater than or equal to 1.5 cm were enrolled to compare the longest dimension before and after NAC at MRI and MBI. MBI was performed on a dual-detector cadmium zinc telluride system after administration of 6.5 mCi (240 MBq) 99mTc-sestamibi. The accuracy of MRI and MBI in assessing residual disease (invasive disease or ductal carcinoma in situ) was determined relative to pathologic examination. RESULTS. The longest dimension at MRI was within 1.0 cm of that at MBI in 72.3% of cases before NAC and 70.1% of cases after NAC. The difference between the longest dimension at imaging after NAC and pathologic tumor size was within 1 cm for 58.7% of breast MRI cases and 59.6% of MBI cases. Ninety patients underwent both MRI and MBI after NAC. In the 56 patients with invasive residual disease, 10 (17.9%) cases were negative at MRI and 23 (41.1%) cases were negative at MBI. In the 34 patients with breast pathologic complete response, there was enhancement in 10 cases (29.4%) at MRI and uptake in six cases (17.6%) at MBI. Sensitivity, specificity, positive predictive value, and negative predictive value after NAC were 82.8%, 69.4%, 81.4%, and 71.4%, respectively, for MRI and 58.9%, 82.4%, 84.6%, and 54.9%, respectively, for MBI. CONCLUSION. Breast MRI and MBI showed similar disease extent before NAC. MBI may be an alternative to breast MRI in patients with a contraindication to breast MRI. Neither modality showed sufficient accuracy after NAC in predicting breast pathologic complete response to obviate tissue diagnosis to assess for residual invasive disease. Defining the extent of residual disease compared with pathologic evaluation was also limited after NAC for both breast MRI and MBI.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/drug therapy , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Ductal, Breast/drug therapy , Magnetic Resonance Imaging/methods , Molecular Imaging/methods , Neoplasm Invasiveness/diagnostic imaging , Adult , Aged , Chemotherapy, Adjuvant , Female , Humans , Middle Aged , Neoadjuvant Therapy , Prospective Studies , Radiopharmaceuticals , Technetium Tc 99m Sestamibi
20.
Clin Case Rep ; 7(3): 442-444, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30899468

ABSTRACT

This case highlights the role of molecular breast imaging (MBI) in evaluating persistent clinical concerns after a negative diagnostic mammogram and ultrasound. MBI is especially useful in the diagnosis of invasive lobular carcinoma due to its occult nature on conventional imaging modalities.

SELECTION OF CITATIONS
SEARCH DETAIL
...