1.
NMR Biomed ; 37(3): e5073, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37990800

ABSTRACT

The goal of this study was to investigate the origin of brain lactate (Lac) signal in the healthy anesthetized rat after injection of hyperpolarized (HP) [1-13 C]pyruvate (Pyr). Dynamic two-dimensional spiral chemical shift imaging with flow-sensitizing gradients revealed reduction in both vascular and brain Pyr, while no significant dependence on the level of flow suppression was detected for Lac. These results support the hypothesis that the HP metabolites predominantly reside in different compartments in the brain (i.e., Pyr in the blood and Lac in the parenchyma). Data from high-resolution metabolic imaging of [1-13 C]Pyr further demonstrated that Lac detected in the brain was not from contributions of vascular signal attributable to partial volume effects. Additionally, metabolite distributions and kinetics measured with dynamic imaging after injection of HP [1-13 C]Lac were similar to Pyr data when Pyr was used as the substrate. These data do not support the hypothesis that Lac observed in the brain after Pyr injection was generated in other organs and then transported across the blood-brain barrier (BBB). Together, the presented results provide further evidence that even in healthy anesthetized rats, the transport of HP Pyr across the BBB is sufficiently fast to permit detection of its metabolic conversion to Lac within the brain.


Subject(s)
Lactic Acid , Pyruvic Acid , Rats , Animals , Pyruvic Acid/metabolism , Lactic Acid/metabolism , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Brain/metabolism , Blood-Brain Barrier/diagnostic imaging , Carbon Isotopes/metabolism
2.
Magn Reson Med ; 91(1): 39-50, 2024 01.
Article in English | MEDLINE | ID: mdl-37796151

ABSTRACT

PURPOSE: To explore the potential of 3T deuterium metabolic imaging (DMI) using a birdcage 2 H radiofrequency (RF) coil in both healthy volunteers and patients with central nervous system (CNS) lesions. METHODS: A modified gradient filter, home-built 2 H volume RF coil, and spherical k-space sampling were employed in a three-dimensional chemical shift imaging acquisition to obtain high-quality whole-brain metabolic images of 2 H-labeled water and glucose metabolic products. These images were acquired in a healthy volunteer and three subjects with CNS lesions of varying pathologies. Hardware and pulse sequence experiments were also conducted to improve the signal-to-noise ratio of DMI at 3T. RESULTS: The ability to quantify local glucose metabolism in correspondence to anatomical landmarks across patients with varying CNS lesions is demonstrated, and increased lactate is observed in one patient with the most active disease. CONCLUSION: DMI offers the potential to examine metabolic activity in human subjects with CNS lesions with DMI at 3T, promising for the potential of the future clinical translation of this metabolic imaging technique.


Subject(s)
Brain , Magnetic Resonance Imaging , Humans , Deuterium , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Signal-To-Noise Ratio , Glucose
3.
NMR Biomed ; 35(9): e4752, 2022 09.
Article in English | MEDLINE | ID: mdl-35483967

ABSTRACT

Here, we report on the development and performance of a robust 3-T single-voxel proton magnetic resonance spectroscopy (1 H MRS) experimental protocol and data analysis pipeline for quantifying brain metabolism during cardiopulmonary bypass (CPB) surgery in a neonatal porcine model, with the overall goal of elucidating primary mechanisms of brain injury associated with these procedures. The specific aims were to assess which metabolic processes can be reliably interrogated by 1 H MRS on a 3-T clinical scanner and to provide an initial assessment of brain metabolism during deep hypothermia cardiac arrest (DHCA) surgery and recovery. Fourteen neonatal pigs underwent CPB surgery while placed in a 3-T MRI scanner for 18, 28, and 37°C DHCA studies under hyperglycemic, euglycemic, and hypoglycemic conditions. Total imaging times, including baseline measurements, circulatory arrest (CA), and recovery averaged 3 h/animal, during which 30-40 single-voxel 1 H MRS spectra (sLASER pulse sequence, TR/TE = 2000/30 ms, 64 or 128 averages) were acquired from a 2.2-cc right midbrain voxel. 1 H MRS at 3 T was able to reliably quantify (1) anaerobic metabolism via depletion of brain glucose and the associated build-up of lactate during CA, (2) phosphocreatine (PCr) to creatine (Cr) conversion during CA and subsequent recovery upon reperfusion, (3) a robust increase in the glutamine-to-glutamate (Gln/Glu) ratio during the post-CA recovery period, and (4) a broadening of the water peak during CA. In vivo 1 H MRS at 3 T can reliably quantify subtle metabolic brain changes previously deemed challenging to interrogate, including brain glucose concentrations even under hypoglycemic conditions, ATP usage via the conversion of PCr to Cr, and differential changes in Glu and Gln. Observed metabolic changes during CPB surgery of a neonatal porcine model provide new insights into possible mechanisms for prevention of neuronal injury.


Subject(s)
Cardiopulmonary Bypass , Creatine , Animals , Brain/diagnostic imaging , Brain/metabolism , Cardiopulmonary Bypass/methods , Creatine/metabolism , Glucose/metabolism , Glutamic Acid/metabolism , Glutamine/metabolism , Hypoglycemic Agents/metabolism , Phosphocreatine/metabolism , Proton Magnetic Resonance Spectroscopy , Swine
4.
Pflugers Arch ; 473(11): 1761-1773, 2021 11.
Article in English | MEDLINE | ID: mdl-34415396

ABSTRACT

The role of pyruvate dehydrogenase in mediating lipid-induced insulin resistance stands as a central question in the pathogenesis of type 2 diabetes mellitus. Many researchers have invoked the Randle hypothesis to explain the reduced glucose disposal in skeletal muscle by envisioning an elevated acetyl CoA pool arising from increased oxidation of fatty acids. Over the years, in vivo NMR studies have challenged that monolithic view. The advent of the dissolution dynamic nuclear polarization NMR technique and a unique type 2 diabetic rat model provides an opportunity to clarify. Dynamic nuclear polarization enhances dramatically the NMR signal sensitivity and allows the measurement of metabolic kinetics in vivo. Diabetic muscle has much lower pyruvate dehydrogenase activity than control muscle, as evidenced in the conversion of [1-13C]lactate and [2-13C]pyruvate to HCO3- and acetyl carnitine. The pyruvate dehydrogenase kinase inhibitor, dichloroacetate, restores rapidly the diabetic pyruvate dehydrogenase activity to control level. However, diabetic muscle has a much larger dynamic change in pyruvate dehydrogenase flux than control. The dichloroacetate-induced surge in pyruvate dehydrogenase activity produces a differential amount of acetyl carnitine but does not affect the tricarboxylic acid flux. Further studies can now proceed with the dynamic nuclear polarization approach and a unique rat model to interrogate closely the biochemical mechanism interfacing oxidative metabolism with insulin resistance and metabolic inflexibility.


Subject(s)
Acetyl Coenzyme A/metabolism , Diabetes Mellitus, Type 2/metabolism , Muscle, Skeletal/metabolism , Pyruvate Dehydrogenase Acetyl-Transferring Kinase/metabolism , Pyruvate Dehydrogenase Complex/metabolism , Pyruvic Acid/metabolism , Animals , Fatty Acids/metabolism , Glucose/metabolism , Insulin Resistance/physiology , Magnetic Resonance Spectroscopy/methods , Myocardium/metabolism , Oxidation-Reduction , Oxidoreductases/metabolism , Rats , Rats, Sprague-Dawley
5.
Sci Rep ; 9(1): 3410, 2019 03 04.
Article in English | MEDLINE | ID: mdl-30833588

ABSTRACT

Metabolic reprogramming is one of the defining features of cancer and abnormal metabolism is associated with many other pathologies. Molecular imaging techniques capable of detecting such changes have become essential for cancer diagnosis, treatment planning, and surveillance. In particular, 18F-FDG (fluorodeoxyglucose) PET has emerged as an essential imaging modality for cancer because of its unique ability to detect a disturbed molecular pathway through measurements of glucose uptake. However, FDG-PET has limitations that restrict its usefulness in certain situations and the information gained is limited to glucose uptake only.13C magnetic resonance spectroscopy theoretically has certain advantages over FDG-PET, but its inherent low sensitivity has restricted its use mostly to single voxel measurements unless dissolution dynamic nuclear polarization (dDNP) is used to increase the signal, which brings additional complications for clinical use. We show here a new method of imaging glucose metabolism in vivo by MRI chemical shift imaging (CSI) experiments that relies on a simple, but robust and efficient, post-processing procedure by the higher dimensional analog of singular value decomposition, tensor decomposition. Using this procedure, we achieve an order of magnitude increase in signal to noise in both dDNP and non-hyperpolarized non-localized experiments without sacrificing accuracy. In CSI experiments an approximately 30-fold increase was observed, enough that the glucose to lactate conversion indicative of the Warburg effect can be imaged without hyper-polarization with a time resolution of 12s and an overall spatial resolution that compares favorably to 18F-FDG PET.


Subject(s)
Glucose/metabolism , Lactic Acid/metabolism , Fluorodeoxyglucose F18/analysis , Magnetic Resonance Spectroscopy , Positron-Emission Tomography/methods
6.
Magn Reson Med ; 82(2): 527-550, 2019 08.
Article in English | MEDLINE | ID: mdl-30919510

ABSTRACT

Proton MRS (1 H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good-quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi-adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0 ) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.


Subject(s)
Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Brain/metabolism , Consensus , Humans , Protons
7.
NMR Biomed ; 32(3): e4052, 2019 03.
Article in English | MEDLINE | ID: mdl-30664305

ABSTRACT

Hyperpolarized 13 C MRI takes advantage of the unprecedented 50 000-fold signal-to-noise ratio enhancement to interrogate cancer metabolism in patients and animals. It can measure the pyruvate-to-lactate conversion rate, kPL , a metabolic biomarker of cancer aggressiveness and progression. Therefore, it is crucial to evaluate kPL reliably. In this study, three sequence components and parameters that modulate kPL estimation were identified and investigated in model simulations and through in vivo animal studies using several specifically designed pulse sequences. These factors included a magnetization spoiling effect due to RF pulses, a crusher gradient-induced flow suppression, and intrinsic image weightings due to relaxation. Simulation showed that the RF-induced magnetization spoiling can be substantially improved using an inputless kPL fitting. In vivo studies found a significantly higher apparent kPL with an additional gradient that leads to flow suppression (kPL,FID-Delay,Crush /kPL,FID-Delay  = 1.37 ± 0.33, P < 0.01, N = 6), which agrees with simulation outcomes (12.5% kPL error with Δv = 40 cm/s), indicating that the gradients predominantly suppressed flowing pyruvate spins. Significantly lower kPL was found using a delayed free induction decay (FID) acquisition versus a minimum-TE version (kPL,FID-Delay /kPL,FID  = 0.67 ± 0.09, P < 0.01, N = 5), and the lactate peak had broader linewidth than pyruvate (Δωlactate /Δωpyruvate  = 1.32 ± 0.07, P < 0.000 01, N = 13). This illustrated that lactate's T2 *, shorter than that of pyruvate, can affect calculated kPL values. We also found that an FID sequence yielded significantly lower kPL versus a double spin-echo sequence that includes spin-echo spoiling, flow suppression from crusher gradients, and more T2 weighting (kPL,DSE /kPL,FID  = 2.40 ± 0.98, P < 0.0001, N = 7). In summary, the pulse sequence, as well as its interaction with pharmacokinetics and the tissue microenvironment, can impact and be optimized for the measurement of kPL . The data acquisition and analysis pipelines can work synergistically to provide more robust and reproducible kPL measures for future preclinical and clinical studies.


Subject(s)
Carbon Isotopes/metabolism , Lactic Acid/metabolism , Magnetic Resonance Imaging , Pyruvic Acid/metabolism , Animals , Computer Simulation , Image Processing, Computer-Assisted , Mice, Inbred C57BL , Models, Theoretical
8.
Oncotarget ; 8(53): 90959-90968, 2017 Oct 31.
Article in English | MEDLINE | ID: mdl-29207616

ABSTRACT

Cancer metabolism has emerged as an increasingly attractive target for interfering with tumor growth. Small molecule activators of pyruvate kinase isozyme M2 (PKM2) suppress tumor formation but have an unknown effect on established tumors. We demonstrate that TEPP-46, a PKM2 activator, results in increased glucose consumption, providing the rationale for combining PKM2 activators with the toxic glucose analog, 2-deoxy-D-glucose (2-DG). Combination treatment resulted in reduced viability of a range of cell lines in standard cell culture conditions at concentrations of drugs that had no effect when used alone. This effect was replicated in vivo on established subcutaneous tumors. We further demonstrated the ability to detect acute metabolic differences in combination treatment using hyperpolarized magnetic resonance spectroscopy (MRS). Combination treated tumors displayed a higher pyruvate to lactate 13C-label exchange 2 hr post-treatment. This ability to assess the effect of drugs non-invasively may accelerate the implementation and clinical translation of drugs that target cancer metabolism.

9.
Magn Reson Med ; 77(5): 1741-1748, 2017 05.
Article in English | MEDLINE | ID: mdl-28261868

ABSTRACT

PURPOSE: The intracellular lactate to pyruvate concentration ratio is a commonly used tissue assay biomarker of redox, being proportional to free cytosolic [NADH]/[NAD+ ]. In this study, we assessed the use of hyperpolarized [1-13 C]alanine and the subsequent detection of the intracellular products of [1-13 C]pyruvate and [1-13 C]lactate as a useful substrate for assessing redox levels in the liver in vivo. METHODS: Animal experiments were conducted to measure in vivo metabolism at baseline and after ethanol infusion. A solution of 80-mM hyperpolarized [1-13 C]alanine was injected intravenously at baseline (n = 8) and 45 min after ethanol infusion (n = 4), immediately followed by the dynamic acquisition of 13 C MRS spectra. RESULTS: In vivo rat liver spectra showed peaks from [1-13 C] alanine and the products of [1-13 C]lactate, [1-13 C]pyruvate, and 13 C-bicarbonate. A significantly increased 13 C-lactate/13 C-pyruvate ratio was observed after ethanol infusion (8.46 ± 0.58 at baseline versus 13.58 ± 0.69 after ethanol infusion; P < 0.001) consistent with the increased NADH produced by liver metabolism of ethanol to acetaldehyde and then acetate. A decrease in 13 C-bicarbonate production was also noted, potentially reflecting ethanol-induced mitochondrial redox changes. CONCLUSION: A method to measure in vivo tissue redox using hyperpolarized [1-13 C]alanine is presented, with the validity of the proposed 13 C-pyruvate/13 C-lactate metric tested using an ethanol challenge to alter liver redox state. Magn Reson Med 77:1741-1748, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Subject(s)
Alanine/chemistry , Carbon Isotopes/chemistry , Liver/diagnostic imaging , Liver/physiology , Oxidation-Reduction , Animals , Cytosol/metabolism , Ethanol/chemistry , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Male , Mitochondria/metabolism , Oxygen/chemistry , Positron-Emission Tomography , Pyruvic Acid/chemistry , Rats , Rats, Wistar , Reproducibility of Results
10.
NMR Biomed ; 29(5): 650-9, 2016 May.
Article in English | MEDLINE | ID: mdl-26990457

ABSTRACT

Hyperpolarized [1-(13)C]pyruvate MRS provides a unique imaging opportunity to study the reaction kinetics and enzyme activities of in vivo metabolism because of its favorable imaging characteristics and critical position in the cellular metabolic pathway, where it can either be reduced to lactate (reflecting glycolysis) or converted to acetyl-coenzyme A and bicarbonate (reflecting oxidative phosphorylation). Cancer tissue metabolism is altered in such a way as to result in a relative preponderance of glycolysis relative to oxidative phosphorylation (i.e. Warburg effect). Although there is a strong theoretical basis for presuming that readjustment of the metabolic balance towards normal could alter tumor growth, a robust noninvasive in vivo tool with which to measure the balance between these two metabolic processes has yet to be developed. Until recently, hyperpolarized (13)C-pyruvate imaging studies had focused solely on [1-(13)C]lactate production because of its strong signal. However, without a concomitant measure of pyruvate entry into the mitochondria, the lactate signal provides no information on the balance between the glycolytic and oxidative metabolic pathways. Consistent measurement of (13)C-bicarbonate in cancer tissue, which does provide such information, has proven difficult, however. In this study, we report the reliable measurement of (13)C-bicarbonate production in both the healthy brain and a highly glycolytic experimental glioblastoma model using an optimized (13)C MRS imaging protocol. With the capacity to obtain signal in all tumors, we also confirm for the first time that the ratio of (13)C-lactate to (13)C-bicarbonate provides a more robust metric relative to (13)C-lactate for the assessment of the metabolic effects of anti-angiogenic therapy. Our data suggest a potential application of this ratio as an early biomarker to assess therapeutic effectiveness. Furthermore, although further study is needed, the results suggest that anti-angiogenic treatment results in a rapid normalization in the relative tissue utilization of glycolytic and oxidative phosphorylation by tumor tissue.


Subject(s)
Bicarbonates/metabolism , Biomarkers, Tumor/metabolism , Lactic Acid/metabolism , Magnetic Resonance Imaging/methods , Vascular Endothelial Growth Factor A/antagonists & inhibitors , Animals , Brain Neoplasms/metabolism , Brain Neoplasms/pathology , Carbon Isotopes , Cell Count , Cell Proliferation , Energy Metabolism , Glioma/metabolism , Glioma/pathology , Male , Metabolome , Rats, Wistar , Tumor Burden , Vascular Endothelial Growth Factor A/metabolism
11.
Magn Reson Med ; 75(2): 917-22, 2016 Feb.
Article in English | MEDLINE | ID: mdl-25765516

ABSTRACT

PURPOSE: Hyperpolarization of carbon-13 ((13) C) nuclei by dissolution dynamic nuclear polarization increases signal-to-noise ratio (SNR) by >10,000-fold for metabolic imaging, but care must be taken when transferring hyperpolarized (HP) samples from polarizer to MR scanner. Some (13) C substrates relax rapidly in low ambient magnetic fields. A handheld electromagnet carrier was designed and constructed to preserve polarization by maintaining a sufficient field during sample transfer. METHODS: The device was constructed with a solenoidal electromagnet, powered by a nonmagnetic battery, holding the HP sample during transfer. A specially designed switch automated deactivation of the field once transfer was complete. Phantom and rat experiments were performed to compare MR signal enhancement with or without the device for HP [(13) C]urea and [1-(13) C]pyruvate. RESULTS: The magnetic field generated by this device was tested to be >50 G over a 6-cm central section. In phantom and rat experiments, [(13) C]urea transported via the device showed SNR improvement by a factor of 1.8-1.9 over samples transferred through the background field. CONCLUSION: A device was designed and built to provide a suitably high yet safe magnetic field to preserve hyperpolarization during sample transfer. Comparative testing demonstrated SNR improvements of approximately two-fold for [(13) C]urea while maintaining SNR for [1-(13) C]pyruvate.


Subject(s)
Electromagnetic Fields , Magnetic Resonance Imaging , Animals , Carbon Isotopes , Equipment Design , Phantoms, Imaging , Rats , Signal-To-Noise Ratio
12.
Magn Reson Med ; 75(3): 973-84, 2016 Mar.
Article in English | MEDLINE | ID: mdl-25946547

ABSTRACT

PURPOSE: MRS of hyperpolarized [2-(13)C]pyruvate can be used to assess multiple metabolic pathways within mitochondria as the (13)C label is not lost with the conversion of pyruvate to acetyl-CoA. This study presents the first MR spectroscopic imaging of hyperpolarized [2-(13)C]pyruvate in glioma-bearing brain. METHODS: Spiral chemical shift imaging with spectrally undersampling scheme (1042 Hz) and a hard-pulse excitation was exploited to simultaneously image [2-(13)C]pyruvate, [2-(13)C]lactate, and [5-(13)C]glutamate, the metabolites known to be produced in brain after an injection of hyperpolarized [2-(13)C]pyruvate, without chemical shift displacement artifacts. A separate undersampling scheme (890 Hz) was also used to image [1-(13)C]acetyl-carnitine. Healthy and C6 glioma-implanted rat brains were imaged at baseline and after dichloroacetate administration, a drug that modulates pyruvate dehydrogenase kinase activity. RESULTS: The baseline metabolite maps showed higher lactate and lower glutamate in tumor as compared to normal-appearing brain. Dichloroacetate led to an increase in glutamate in both tumor and normal-appearing brain. Dichloroacetate-induced %-decrease of lactate/glutamate was comparable to the lactate/bicarbonate decrease from hyperpolarized [1-(13)C]pyruvate studies. Acetyl-carnitine was observed in the muscle/fat tissue surrounding the brain. CONCLUSION: Robust volumetric imaging with hyperpolarized [2-(13)C]pyruvate and downstream products was performed in glioma-bearing rat brains, demonstrating changes in mitochondrial metabolism with dichloroacetate.


Subject(s)
Brain Neoplasms/pathology , Carbon Isotopes/metabolism , Glioma/pathology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Neuroimaging/methods , Pyruvic Acid/metabolism , Animals , Brain/metabolism , Brain/pathology , Carbon Isotopes/chemistry , Male , Pyruvic Acid/chemistry , Rats , Rats, Wistar , Signal Processing, Computer-Assisted
13.
J Exp Biol ; 218(Pt 20): 3308-18, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26347554

ABSTRACT

The production of glycolytic end products, such as lactate, usually evokes a cellular shift from aerobic to anaerobic ATP generation and O2 insufficiency. In the classical view, muscle lactate must be exported to the liver for clearance. However, lactate also forms under well-oxygenated conditions, and this has led investigators to postulate lactate shuttling from non-oxidative to oxidative muscle fiber, where it can serve as a precursor. Indeed, the intracellular lactate shuttle and the glycogen shunt hypotheses expand the vision to include a dynamic mobilization and utilization of lactate during a muscle contraction cycle. Testing the tenability of these provocative ideas during a rapid contraction cycle has posed a technical challenge. The present study reports the use of hyperpolarized [1-(13)C]lactate and [2-(13)C]pyruvate in dynamic nuclear polarization (DNP) NMR experiments to measure the rapid pyruvate and lactate kinetics in rat muscle. With a 3 s temporal resolution, (13)C DNP NMR detects both [1-(13)C]lactate and [2-(13)C]pyruvate kinetics in muscle. Infusion of dichloroacetate stimulates pyruvate dehydrogenase activity and shifts the kinetics toward oxidative metabolism. Bicarbonate formation from [1-(13)C]lactate increases sharply and acetyl-l-carnitine, acetoacetate and glutamate levels also rise. Such a quick mobilization of pyruvate and lactate toward oxidative metabolism supports the postulated role of lactate in the glycogen shunt and the intracellular lactate shuttle models. The study thus introduces an innovative DNP approach to measure metabolite transients, which will help delineate the cellular and physiological role of lactate and glycolytic end products.


Subject(s)
Lactic Acid/metabolism , Muscle, Skeletal/metabolism , Pyruvic Acid/metabolism , Animals , Bicarbonates/metabolism , Carbon-13 Magnetic Resonance Spectroscopy , Dichloroacetic Acid/pharmacology , Glutamic Acid/metabolism , Male , Oxidation-Reduction , Pyruvate Dehydrogenase Complex/metabolism , Rats , Rats, Sprague-Dawley
14.
Radiology ; 270(3): 658-79, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24568703

ABSTRACT

A large body of published work shows that proton (hydrogen 1 [(1)H]) magnetic resonance (MR) spectroscopy has evolved from a research tool into a clinical neuroimaging modality. Herein, the authors present a summary of brain disorders in which MR spectroscopy has an impact on patient management, together with a critical consideration of common data acquisition and processing procedures. The article documents the impact of (1)H MR spectroscopy in the clinical evaluation of disorders of the central nervous system. The clinical usefulness of (1)H MR spectroscopy has been established for brain neoplasms, neonatal and pediatric disorders (hypoxia-ischemia, inherited metabolic diseases, and traumatic brain injury), demyelinating disorders, and infectious brain lesions. The growing list of disorders for which (1)H MR spectroscopy may contribute to patient management extends to neurodegenerative diseases, epilepsy, and stroke. To facilitate expanded clinical acceptance and standardization of MR spectroscopy methodology, guidelines are provided for data acquisition and analysis, quality assessment, and interpretation. Finally, the authors offer recommendations to expedite the use of robust MR spectroscopy methodology in the clinical setting, including incorporation of technical advances on clinical units.


Subject(s)
Biomarkers/metabolism , Central Nervous System Diseases/diagnosis , Magnetic Resonance Spectroscopy/methods , Central Nervous System Diseases/metabolism , Central Nervous System Diseases/pathology , Humans
15.
NMR Biomed ; 27(2): 212-8, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24353129

ABSTRACT

Blip-reversed echo-planar imaging (EPI) is investigated as a method for measuring and correcting the spatial shifts that occur due to bulk frequency offsets in (13)C metabolic imaging in vivo. By reversing the k-space trajectory for every other time point, the direction of the spatial shift for a given frequency is reversed. Here, mutual information is used to find the 'best' alignment between images and thereby measure the frequency offset. Time-resolved 3D images of pyruvate/lactate/urea were acquired with 5 s temporal resolution over a 1 min duration in rats (N = 6). For each rat, a second injection was performed with the demodulation frequency purposely mis-set by +35 Hz, to test the correction for erroneous shifts in the images. Overall, the shift induced by the 35 Hz frequency offset was 5.9 ± 0.6 mm (mean ± standard deviation). This agrees well with the expected 5.7 mm shift based on the 2.02 ms delay between k-space lines (giving 30.9 Hz per pixel). The 0.6 mm standard deviation in the correction corresponds to a frequency-detection accuracy of 4 Hz. A method was presented for ensuring the spatial registration between (13)C metabolic images and conventional anatomical images when long echo-planar readouts are used. The frequency correction method was shown to have an accuracy of 4 Hz. Summing the spatially corrected frames gave a signal-to-noise ratio (SNR) improvement factor of 2 or greater, compared with the highest single frame.


Subject(s)
Artifacts , Echo-Planar Imaging/methods , Kidney/anatomy & histology , Kidney/metabolism , Lactic Acid/metabolism , Pyruvic Acid/metabolism , Urea/metabolism , Algorithms , Animals , Carbon Isotopes/pharmacokinetics , Magnetic Resonance Spectroscopy/methods , Molecular Imaging/methods , Radiopharmaceuticals/pharmacokinetics , Rats , Rats, Nude , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic , Tissue Distribution
16.
Sci Transl Med ; 5(198): 198ra108, 2013 Aug 14.
Article in English | MEDLINE | ID: mdl-23946197

ABSTRACT

This first-in-man imaging study evaluated the safety and feasibility of hyperpolarized [1-¹³C]pyruvate as an agent for noninvasively characterizing alterations in tumor metabolism for patients with prostate cancer. Imaging living systems with hyperpolarized agents can result in more than 10,000-fold enhancement in signal relative to conventional magnetic resonance (MR) imaging. When combined with the rapid acquisition of in vivo ¹³C MR data, it is possible to evaluate the distribution of agents such as [1-¹³C]pyruvate and its metabolic products lactate, alanine, and bicarbonate in a matter of seconds. Preclinical studies in cancer models have detected elevated levels of hyperpolarized [1-¹³C]lactate in tumor, with the ratio of [1-¹³C]lactate/[1-¹³C]pyruvate being increased in high-grade tumors and decreased after successful treatment. Translation of this technology into humans was achieved by modifying the instrument that generates the hyperpolarized agent, constructing specialized radio frequency coils to detect ¹³C nuclei, and developing new pulse sequences to efficiently capture the signal. The study population comprised patients with biopsy-proven prostate cancer, with 31 subjects being injected with hyperpolarized [1-¹³C]pyruvate. The median time to deliver the agent was 66 s, and uptake was observed about 20 s after injection. No dose-limiting toxicities were observed, and the highest dose (0.43 ml/kg of 230 mM agent) gave the best signal-to-noise ratio for hyperpolarized [1-¹³C]pyruvate. The results were extremely promising in not only confirming the safety of the agent but also showing elevated [1-¹³C]lactate/[1-¹³C]pyruvate in regions of biopsy-proven cancer. These findings will be valuable for noninvasive cancer diagnosis and treatment monitoring in future clinical trials.


Subject(s)
Magnetic Resonance Imaging/methods , Prostatic Neoplasms/diagnosis , Pyruvic Acid , Aged , Carbon Isotopes , Humans , Male , Middle Aged , Sensitivity and Specificity
17.
NMR Biomed ; 26(10): 1197-203, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23553852

ABSTRACT

Hyperpolarized [1-(13) C]pyruvate ([1-(13) C]Pyr) has been used to assess metabolism in healthy and diseased states, focusing on the downstream labeling of lactate (Lac), bicarbonate and alanine. Although hyperpolarized [2-(13) C]Pyr, which retains the labeled carbon when Pyr is converted to acetyl-coenzyme A, has been used successfully to assess mitochondrial metabolism in the heart, the application of [2-(13) C]Pyr in the study of brain metabolism has been limited to date, with Lac being the only downstream metabolic product reported previously. In this study, single-time-point chemical shift imaging data were acquired from rat brain in vivo. [5-(13) C]Glutamate, [1-(13) C]acetylcarnitine and [1-(13) C]citrate were detected in addition to resonances from [2-(13) C]Pyr and [2-(13) C]Lac. Brain metabolism was further investigated by infusing dichloroacetate, which upregulates Pyr flux to acetyl-coenzyme A. After dichloroacetate administration, a 40% increase in [5-(13) C]glutamate from 0.014 ± 0.004 to 0.020 ± 0.006 (p = 0.02), primarily from brain, and a trend to higher citrate (0.002 ± 0.001 to 0.004 ± 0.002) were detected, whereas [1-(13) C]acetylcarnitine was increased in peripheral tissues. This study demonstrates, for the first time, that hyperpolarized [2-(13) C]Pyr can be used for the in vivo investigation of mitochondrial function and tricarboxylic acid cycle metabolism in brain.


Subject(s)
Brain/metabolism , Magnetic Resonance Spectroscopy/methods , Mitochondria/metabolism , Pyruvates/metabolism , Animals , Carbon Isotopes , Male , Metabolic Networks and Pathways , Rats , Rats, Wistar , Time Factors
18.
Neuro Oncol ; 15(4): 433-41, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23328814

ABSTRACT

BACKGROUND: The metabolic phenotype that derives disproportionate energy via glycolysis in solid tumors, including glioma, leads to elevated lactate labeling in metabolic imaging using hyperpolarized [1-(13)C]pyruvate. Although the pyruvate dehydrogenase (PDH)-mediated flux from pyruvate to acetyl coenzyme A can be indirectly measured through the detection of carbon-13 ((13)C)-labeled bicarbonate, it has proven difficult to visualize (13)C-bicarbonate at high enough levels from injected [1-(13)C]pyruvate for quantitative analysis in brain. The aim of this study is to improve the detection of (13)C-labeled metabolites, in particular bicarbonate, in glioma and normal brain in vivo and to measure the metabolic response to dichloroacetate, which upregulates PDH activity. METHODS: An optimized protocol for chemical shift imaging and high concentration of hyperpolarized [1-(13)C]pyruvate were used to improve measurements of lactate and bicarbonate in C6 glioma-transplanted rat brains. Hyperpolarized [1-(13)C]pyruvate was injected before and 45 min after dichloroacetate infusion. Metabolite ratios of lactate to bicarbonate were calculated to provide improved metrics for characterizing tumor metabolism. RESULTS: Glioma and normal brain were well differentiated by lactate-to-bicarbonate ratio (P = .002, n = 5) as well as bicarbonate (P = .0002) and lactate (P = .001), and a stronger response to dichloroacetate was observed in glioma than in normal brain. CONCLUSION: Our results clearly demonstrate for the first time the feasibility of quantitatively detecting (13)C-bicarbonate in tumor-bearing rat brain in vivo, permitting the measurement of dichloroacetate-modulated changes in PDH flux. The simultaneous detection of lactate and bicarbonate provides a tool for a more comprehensive analysis of glioma metabolism and the assessment of metabolic agents as anti-brain cancer drugs.


Subject(s)
Brain Neoplasms/metabolism , Brain/metabolism , Carbon Radioisotopes , Dichloroacetic Acid/pharmacology , Glioma/metabolism , Magnetic Resonance Imaging , Acetyl Coenzyme A/metabolism , Animals , Brain/drug effects , Brain/pathology , Brain Neoplasms/drug therapy , Brain Neoplasms/pathology , Glioma/drug therapy , Glioma/pathology , Male , Mitochondria/drug effects , Mitochondria/metabolism , Protein Serine-Threonine Kinases/metabolism , Pyruvate Dehydrogenase Acetyl-Transferring Kinase , Pyruvates/metabolism , Rats , Rats, Wistar , Tumor Cells, Cultured
19.
Magn Reson Imaging ; 31(5): 635-42, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23260391

ABSTRACT

Metabolic imaging with hyperpolarized [1-(13)C]-pyruvate can rapidly probe tissue metabolic profiles in vivo and has been shown to provide cancer imaging biomarkers for tumor detection, progression, and response to therapy. This technique uses a bolus injection followed by imaging within 1-2 minutes. The observed metabolites include vascular components and their generation is also influenced by cellular transport. These factors complicate image interpretation, especially since [1-(13)C]lactate, a metabolic product that is a biomarker of cancer, is also produced by red blood cells. It would be valuable to understand the distribution of metabolites between the vasculature, interstitial space, and intracellular compartments. The purpose of this study was to better understand this compartmentalization by using a perfusion and diffusion-sensitive stimulated-echo acquisition mode (STEAM) MRSI acquisition method tailored to hyperpolarized substrates. Our results in mouse models showed that among metabolites, the injected substrate (13)C-pyruvate had the largest vascular fraction overall while (13)C-alanine had the smallest vascular fraction. We observed a larger vascular fraction of pyruvate and lactate in the kidneys and liver when compared to back muscle and prostate tumor tissue. Our data suggests that (13)C-lactate in prostate tumor tissue voxels was the most abundant labeled metabolite intracellularly. This was shown in STEAM images that highlighted abnormal cancer cell metabolism and suppressed vascular (13)C metabolite signals.


Subject(s)
Biomarkers, Tumor/metabolism , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Perfusion Imaging/methods , Prostatic Neoplasms/metabolism , Prostatic Neoplasms/pathology , Animals , Carbon Isotopes/pharmacokinetics , Contrast Media/pharmacokinetics , Male , Mice , Radiopharmaceuticals/pharmacokinetics , Reproducibility of Results , Sensitivity and Specificity
20.
Magn Reson Med ; 70(4): 936-42, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23165935

ABSTRACT

PURPOSE: The use of unlabeled exchange-linked dissolution agents in hyperpolarized metabolic imaging was studied to examine pool size limits and saturation relative to the availability of NADH. METHODS: Three-dimensional dynamic metabolic images were obtained, and compared following injection of a bolus of hyperpolarized [1-(13)C]pyruvate, prepared with and without unlabeled sodium lactate in the dissolution buffer. Comparisons were made on the basis of apparent rate constants and [1-(13)C]lactate signal-to-noise ratio. Range finding data were obtained for different bolus compositions. Isotope exchange was also probed in the reverse direction, following injection of a bolus of hyperpolarized [1-(13)C]lactate, with and without unlabeled sodium pyruvate in the dissolution buffer. RESULTS: Liver, kidney, and vascular regions of interest all showed an increase in [1-(13)C]lactate signal with addition of unlabeled sodium lactate in the dissolution buffer. Injection of hyperpolarized [1-(13)C]lactate with unlabeled sodium pyruvate in the dissolution buffer, provided exchange rate constants Klp for kidney and vascular regions of interest. CONCLUSIONS: These results are consistent with a high level of (13)C-exchange, and with labeling rates that are limited by steady-state pool sizes in vivo.


Subject(s)
Blood Vessels/metabolism , Kidney/metabolism , Liver/metabolism , Magnetic Resonance Imaging/methods , Molecular Imaging/methods , Pyruvic Acid/pharmacokinetics , Sodium Lactate/pharmacokinetics , Animals , Carbon Isotopes/pharmacokinetics , Male , Organ Specificity , Radiopharmaceuticals/pharmacokinetics , Rats , Rats, Wistar , Reproducibility of Results , Sensitivity and Specificity