Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
ERJ Open Res ; 10(4)2024 Jul.
Article in English | MEDLINE | ID: mdl-39040587

ABSTRACT

Introduction: This study aims to answer the question of whether adding mobile cone-beam computed tomography (mCBCT) imaging to shape-sensing robotic-assisted bronchoscopy (ssRAB) translates into a quantifiable improvement in the tool-lesion relationship. Methods: Data from 102 peripheral lung lesions with ≥2 sequential mCBCT orbital spins and from 436 lesions with 0-1 spins were prospectively captured and retrospectively analysed. The primary outcome was the tool-lesion relationship status across the first and the last mCBCT spins. Secondary outcomes included 1) the change in distance between the tip of the sampling tool and the centre of the lesion between the first and the last spins and 2) the per-lesion diagnostic yield. Results: Compared to lesions requiring 0-1 spins, lesions requiring ≥2 spins were smaller and had unfavourable bronchus sign and intra-operative sonographic view. On the first spin, 54 lesions (53%) were designated as non-tool-in-lesion (non-TIL) while 48 lesions (47%) were designated as TIL. Of the 54 initially non-TIL cases, 49 (90%) were converted to TIL status by the last spin. Overall, on the last spin, 96 out of 102 lesions (94%) were defined as TIL and six out of 102 lesions (6%) were defined as non-TIL (p<0.0001). The mean distance between the tool and the centre of the lesion decreased from 10.4 to 6.6 mm between the first and last spins (p<0.0001). The overall diagnostic yield was 77%. Conclusion: Targeting traditionally challenging lung lesions, intra-operative volumetric imaging allowed for the conversion of 90% of non-TIL status to TIL. Guidance with mCBCT resulted in a significant decrease in the distance between the tip of the needle to lesion centre.

2.
Article in English | MEDLINE | ID: mdl-38936600

ABSTRACT

OBJECTIVE: Shape-sensing robotic-assisted bronchoscopy is an emerging technology for the sampling of pulmonary lesions. We seek to characterize the shape-sensing robotic-assisted bronchoscopy learning curve at an academic center. METHODS: Shape-sensing robotic-assisted bronchoscopy procedures performed by 9 proceduralists at a single institution were analyzed. Cumulative sum analyses were performed to examine diagnostic sampling and procedure time over each operator's first 50 cases, with the acceptable yield threshold set to 73%. RESULTS: During the study period, 442 patients underwent sampling of 551 lesions. Each operator sampled 61 lesions (interquartile range, 60-63 lesions). Lesion size was 1.90 cm (interquartile range, 1.33-2.80 cm). The median procedure time for single-target cases decreased from 62 minutes during the first 10 cases to 39 minutes after case 40 (P < .001). The overall diagnostic yield was 72% (range, 58%-83%). Six of 9 operators achieved proficiency over the study period. An aggregated cumulative sum analysis of those who achieved competency demonstrated a steep improvement between lesions 1 and 21 and crossing of the competency threshold by lesion 25. Temporal analysis of yield-related lesion characteristics demonstrated that at approximately lesion 20, more challenging lesions were increasingly targeted, as evidenced by smaller target size, higher rates of unfavorable radial endobronchial ultrasound views, and a negative bronchus sign. CONCLUSIONS: Skills acquisition in shape-sensing robotic-assisted bronchoscopy is variable. Approximately half of proceduralists become facile with the technology within 25 lesions. After the initial learning phase, operators increasingly target lesions with more challenging features. Overall, these findings can inform certification and competency standards and provide new users with expectations related to performance over time.

3.
Respirology ; 29(9): 803-814, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38806394

ABSTRACT

BACKGROUND AND OBJECTIVE: Robotic-assisted bronchoscopy (RAB) is an emerging modality to sample pulmonary lesions. Cone-beam computed tomography (CBCT) can be incorporated into RAB. We investigated the magnitude and predictors of patient and staff radiation exposure during mobile CBCT-guided shape-sensing RAB. METHODS: Patient radiation dose was estimated by cumulative dose area product (cDAP) and cumulative reference air kerma (cRAK). Staff equivalent dose was calculated based on isokerma maps and a phantom simulation. Patient, lesion and procedure-related factors associated with higher radiation doses were identified by logistic regression models. RESULTS: A total of 198 RAB cases were included in the analysis. The median patient cDAP and cRAK were 10.86 Gy cm2 (IQR: 4.62-20.84) and 76.20 mGy (IQR: 38.96-148.38), respectively. Among staff members, the bronchoscopist was exposed to the highest median equivalent dose of 1.48 µSv (IQR: 0.85-2.69). Both patient and staff radiation doses increased with the number of CBCT spins and targeted lesions (p < 0.001 for all comparisons). Patient obesity, negative bronchus sign, lesion size <2.0 cm and inadequate sampling by on-site evaluation were associated with a higher patient dose, while patient obesity and inadequate sampling by on-site evaluation were associated with a higher bronchoscopist equivalent dose. CONCLUSION: The magnitude of patient and staff radiation exposure during CBCT-RAB is aligned with safety thresholds recommended by regulatory authorities. Factors associated with a higher radiation exposure during CBCT-RAB can be identified pre-operatively and solicit procedural optimization by reinforcing radiation protective measures. Future studies are needed to confirm these findings across multiple institutions and practices.


Subject(s)
Bronchoscopy , Cone-Beam Computed Tomography , Radiation Exposure , Robotic Surgical Procedures , Humans , Cone-Beam Computed Tomography/methods , Bronchoscopy/methods , Bronchoscopy/adverse effects , Male , Female , Radiation Exposure/adverse effects , Middle Aged , Robotic Surgical Procedures/adverse effects , Occupational Exposure/adverse effects , Aged , Radiation Dosage , Phantoms, Imaging , Adult , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy
SELECTION OF CITATIONS
SEARCH DETAIL