Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 85
Filter
1.
Article in English | WPRIM (Western Pacific) | ID: wpr-1040393

ABSTRACT

Background@#Despite the popularity of the NeoBase 2 Non-derivatized MSMS assay (PerkinElmer, Turku, Finland), there are no reports of its comprehensive evaluation, including the ability to distinguish transient tyrosinemia of the newborn (TTN) from tyrosinemia type 1 (TYR 1) using succinylacetone (SUAC). No newborn screening (NBS) cutoffs for preterm neonates in the Korean population have been suggested. We evaluated the NeoBase 2 assay and identified analytes requiring different cutoffs in preterm neonates. @*Methods@#Residual NBS dried blood spot samples and proficiency testing (PT) materials of the Newborn Screening Quality Assurance Program and the Korean Association of External Quality Assessment Service were used. Precision, accuracy, limit of detection (LOD), lower limit of quantification (LLOQ), linearity, recovery, carryover, and performance of SUAC were evaluated. Cutoffs were determined, and analytes requiring different cutoffs in preterm neonates were investigated. @*Results@#Mean CVs for within-run and between-day precision were within 15%. Accuracy analysis indicated high agreement with in-house derivatized assay results and results of other PT participants. All analytes demonstrated acceptable LOD, LLOQ, and linearity. Recoveries were acceptable, except for SUAC. Carryover was negligible. Cutoffs were established for all analytes; Tyr, adenosine, and C20:0-lysophosphatidylcholine required different cutoffs in preterm neonates. Differential diagnosis of TYR 1 and TTN was successful with simultaneous Tyr and SUAC measurement. @*Conclusions@#The NeoBase 2 assay demonstrated satisfactory performance. The additional analytes provide a wider diagnostic coverage, and the simultaneous measurement of Tyr and SUAC is efficient in excluding TYR 1. The new cutoffs for preterm neonates may decrease false-positive rates, without compromising diagnostic sensitivity.

2.
Article in English | WPRIM (Western Pacific) | ID: wpr-1040421

ABSTRACT

Background@#Serum cystatin C (cysC), which is less affected by sex, race, and muscle mass than creatinine, is a useful biomarker of the estimated glomerular filtration rate (eGFR). The standardization of cysC measurements remains controversial, although a certified reference material (ERM-DA471/IFCC) is available. Moreover, the effect of combinations of cysC reagents and equations for eGFR is unclear. @*Methods@#We conducted a simulation analysis of cysC measured using two reagents standardized against ERM-DA471/IFCC—Gentian cystatin C immunoassay (Gentiancys; GentianAS, Moss, Norway) and Roche Tina-quant Cystatin C Gen.2 (Rochecys; Roche, Mannheim, Germany)—on a Cobas c702 system (Roche) and eGFR generated by eight combinations of four equations: 2012 cystatin C-based Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPIcys); the Caucasian, Asian, pediatric, and adult equation (CAPAeq); full age spectrum equation (FASeq); and 2023 cystatin C-based European Kidney Function Consortium equation (EKFCcys). @*Results@#A total of 148 participants (mean age, 60.5±14.5 years; 43% female) were enrolled. The mean cysC was 1.72±1.44 mg/L for Gentiancys and 1.71±1.35 mg/L for Rochecys. Regression analysis showed concordance between the reagents within 0.85–4.40 mg/L when using ±7.61% total allowable error. Lin’s concordance correlation coefficient of eGFR, by combining the measuring system and equation, varied from 0.73 to 1.00. @*Conclusions@#The equivalence of cysC values at low concentrations (<0.85 mg/L) between the two reagents was unsatisfactory. Results obtained with different measurement systems could lead to larger differences in eGFR varying with the combination.

3.
Article in English | WPRIM (Western Pacific) | ID: wpr-1040435

ABSTRACT

Background@#To ensure valid results of big data research in the medical field, the input laboratory results need to be of high quality. We aimed to establish a strategy for evaluating the quality of laboratory results suitable for big data research. @*Methods@#We used Korean Association of External Quality Assessment Service (KEQAS) data to retrospectively review multicenter data. Seven measurands were analyzed using commutable materials: HbA1c, creatinine (Cr), total cholesterol (TC), triglyceride (TG), alpha-fetoprotein (AFP), prostate-specific antigen (PSA), and cardiac troponin I (cTnI). These were classified into three groups based on their standardization or harmonization status. HbA1c, Cr, TC, TG, and AFP were analyzed with respect to peer group values. PSA and cTnI were analyzed in separate peer groups according to the calibrator type and manufacturer, respectively. The acceptance rate and absolute percentage bias at the medical decision level were calculated based on biological variation criteria. @*Results@#The acceptance rate (22.5%–100%) varied greatly among the test items, and the mean percentage biases were 0.6%–5.6%, 1.0%–9.6%, and 1.6%–11.3% for all items that satisfied optimum, desirable, and minimum criteria, respectively. @*Conclusions@#The acceptance rate of participants and their external quality assessment (EQA) results exhibited statistically significant differences according to the quality grade for each criterion. Even when they passed the EQA standards, the test results did not guarantee the quality requirements for big data. We suggest that the KEQAS classification can serve as a guide for building big data.

4.
Article in English | WPRIM (Western Pacific) | ID: wpr-966809

ABSTRACT

Background@#Thyroxine-binding globulin (TBG) is a major transporter protein for thyroid hormones. The serpin family A member 7 (SERPINA7) gene codes for TBG, and mutations of the SERPINA7 gene result in TBG deficiency. Although more than 40 mutations have been reported in several countries, only a few studies of TBG deficiency and SERPINA7 gene mutation have been performed in Korea. The aim of this study is to review the clinical presentations and laboratory findings of patients with TBG deficiency and to investigate the types of SERPINA7 gene mutation. @*Methods@#Five unrelated Korean adults with TBG deficiency attending endocrinology clinic underwent SERPINA7 gene sequencing. Four patients harbored a SERPINA7 gene mutation. Serum thyroid hormones, anti-microsomal antibodies, and TBG were measured. Genomic DNA was extracted from whole blood. All exons and intron-exon boundaries of the TBG gene were amplified and sequencing was performed. @*Results@#Two patients were heterozygous females, and the other two were hemizygous males. One heterozygous female had coexisting hypothyroidism. The other heterozygous female was erroneously prescribed levothyroxine at a local clinic. One hemizygous male harbored a novel mutation, p.Phe269Cysfs*18, which caused TBG partial deficiency. Three patients had the p.Leu372Phefs*23 mutation, which is known as TBG-complete deficiency Japan (TBG-CDJ) and was also presented in previous mutation analyses in Korea. @*Conclusion@#This study presents four patients diagnosed with TBG deficiency and provides the results of SERPINA7 gene sequencing. One novel mutation, p.Phe269Cysfs*18, causing TBD-partial deficiency and three cases of TBG-CDJ were demonstrated. It is necessary to identify TBG deficiency to prevent improper treatment. Also, sequencing of the SERPINA7 gene would provide valuable information about the TBG variants in Korea.

5.
Article in English | WPRIM (Western Pacific) | ID: wpr-874129

ABSTRACT

The Barricor tube (Becton Dickinson [BD], Sunnyvale, CA, USA) was recently developed to mechanically separate plasma by increasing the centrifugation rate. We compared the Barricor tube with existing serum- and plasma-based tubes based on 35 biochemical analytes and preanalytical turnaround time (TAT). Blood samples were collected from 30 healthy volunteers in a Barricor tube, serum separating tube (SST, Vacutainer SST II Tube 8.5 mL, #368972; BD), or plasma separating tube (PST, Vacutainer PST Tube 8.0 mL, #367964; BD) in random order. Next, 27 chemistry analytes, six immunochemistry analytes, and two cardiac markers were compared using Passing-Bablok regression and the Bland-Altman method. Preanalytical TAT was measured for each tube.The Barricor tube exhibited bias exceeding the desirable limit for nine and four analytes compared with the SST and PST, respectively. The Barricor tube lactate dehydrogenase value showed a bias of -10.29% and -9.86% compared with that of the SST and PST, respectively. The preanalytical TAT of Barricor tube was 8.8 minutes, which was the shortest among the three tubes. The clinical performance of the Barricor tube was equivalent to that of the SST and PST for most analytes, with an apparent advantage in preanalytical TAT. When using the Barricor tube, the reference range needs to be changed for some analytes that exceed the desirable bias limit.

6.
Article in English | WPRIM (Western Pacific) | ID: wpr-874155

ABSTRACT

Background@#Total cholesterol concentration measurement is important in the diagnosis of dyslipidemia and evaluation of cardiovascular disease risk factors. Measurement reliability for obtaining an accurate total cholesterol concentration requires procedure standardization. We evaluated the standardization status for total cholesterol concentration measurement through Korean external quality assessment (EQA) data analysis. @*Methods@#This study involved 1,670 laboratories that participated in the EQA of total cholesterol concentration measurements in 2019 for 32 products from different manufacturers. The target concentrations of three quality control (QC) materials (samples A, B, and C) were measured using the reference method and compared with EQA data. The performance criteria for total cholesterol concentration measurement were based on the National Cholesterol Education Program guidelines, with ± 3% inaccuracy. @*Results@#The target values and inaccuracies of the QC material based on the reference method measurements were 254.65 ± 7.64, 108.30 ± 3.25, and 256.29 ± 7.69 mg/dL (6.59 ± 0.20, 2.80 ± 0.08, and 6.63 ± 0.20 mmol/L) for samples A, B, and C, respectively.The performance criteria were not met in 42.7% laboratories for sample A, 68.4% of laboratories for sample B, and 38.0% laboratories for sample C. @*Conclusions@#Despite significant efforts to accurately measure total cholesterol concentrations, further actions are needed for measurement standardization. Manufacturers reporting values that differ from target values should check calibrator traceability; additional efforts to accurately measure total cholesterol concentrations are required for laboratories that use products from these manufacturers.

7.
Article in English | WPRIM (Western Pacific) | ID: wpr-874169

ABSTRACT

External quality assessment (EQA) is important for evaluating clinical laboratories and enhancing their testing quality. EQA schemes are variable; thus, it is crucial that the EQA organizers share their experiences to continuously improve the EQA scheme. The Korean Association of External Quality Assessment Service (KEQAS) has been the leading, authorized EQA institute for the standardization and quality management of laboratory testing in Korean medical institutions since 1976. The EQA scheme underwent a major change in 2016, and the number of EQA programs increased significantly since then. The key changes implemented in EQA scheme include a fully computerized assessment to accelerate feedback and unification of the testing and reporting methods. We provide an overview of the EQA schemes and performance evaluation criteria of the KEQAS and suggest directions for achieving the global harmonization of EQA.

8.
Article in English | WPRIM (Western Pacific) | ID: wpr-874190

ABSTRACT

Background@#Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is increasingly used for immunosuppressive drug tests. However, most LC-MS/MS tests are laboratory-developed and their agreement is unknown in different Korean laboratories.This interlaboratory comparison study evaluated test reproducibility and identified potential error sources. @*Methods@#Test samples containing three concentrations of tacrolimus, sirolimus, everolimus, cyclosporine, and mycophenolic acid were prepared by pooling surplus samples from patients undergoing routine therapeutic drug monitoring and tested in duplicate in the participating 10 clinical laboratories. Reconstitution and storage experiments were conducted for the commonly used commercial calibrator set. The robust estimators of reproducibility parameters were calculated. Spearman’s rank correlation coefficient (rho, ρ) was used to evaluate the correlation between drugs. Multiple linear regression was used to determine whether the experimental conditions alter the calibration curves. @*Results@#The reproducibility coefficient of variation exceeded 10% only for sirolimus concentrations 1 and 2 (10.8% and 12.5%, respectively) and everolimus concentrations 1 and 2 (12.3% and 11.4%, respectively). The percent difference values showed weak correlations between sirolimus and everolimus (ρ = 0.334, P = 0.175). The everolimus calibration curve slope was significantly altered after reconstitution following prolonged 5°C storage (P = 0.015 for 14 days; P = 0.025 for 28 days); the expected differences at 6 ng/mL were 0.598% for 14 days and 0.384% for 28 days. @*Conclusions@#LC-MS/MS test reproducibility for immunosuppressive drugs seems to be good in the Korean clinical laboratories. Continuous efforts are required to achieve test standardization and harmonization, especially for sirolimus and everolimus.

9.
Article in English | WPRIM (Western Pacific) | ID: wpr-831570

ABSTRACT

Background@#Teicoplanin is used to treat serious gram-positive infections. Optimal teicoplanin trough levels are considered to be ≥ 10 μg/mL. Despite its wide use in various clinical settings, data on teicoplanin trough level in pediatric patients are limited. Therefore, the aim of this study was to investigate the therapeutic drug level monitoring of teicoplanin in Korean pediatric patients, including those with impaired renal function. @*Methods@#A retrospective study was performed in pediatric patients (age ≤ 18 years old) who received teicoplanin from September 2014 to April 2018. The regimen included a loading dose of 10 mg/kg/dose at 12 hours' interval three times in a row, and a maintenance dose of 10 mg/kg/dose commenced at 24 hours of interval after the loading dose, with a maximum of 400 mg/dose, respectively. The first therapeutic drug levels were measured. Distribution and characteristics of trough levels in patients with decreased renal function and those with bacteremia were also assessed. @*Results@#A total of 187 trough levels were collected from 143 patients. Hematologic and oncologic diseases were the most common underlying diseases (83.2%, n = 119). One hundred eighty trough levels were first measured, and their median value was 16.2 μg/mL (range, 2.3–100 μg/mL) and the median interval between initial teicoplanin injection and 1st trough level was 96.5 hours (range 47.6–179.3 hours). Lower steady-state levels were observed in younger age group (median, 13.5 vs. 18.0 μg/mL, P = 0.038). Median trough levels were higher in patients with decreased renal functions (P < 0.001). In addition, among eight with gram-positive bacteremia, seven of them had a favorable outcome. @*Conclusion@#This study provides additive information on trough level monitoring of teicoplanin in children with impaired renal function and treatment effect in patients with gram-positive bacteremia. Careful monitoring for steady state trough levels of teicoplanin is warranted.

10.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-782249

ABSTRACT

0.99, slope: 0.965 and 0.955). When Modular D and Cobas 8000c 702 were compared, the slope and y-intercept were 0.9928 (95% confidence interval [CI]: 0.9802 to 1.000) and -0.0156 (95% CI: −0.0200 to −0.0054), respectively. The slope and y-intercept were 0.9811 (95% CI: 0.9570 to 0.9951) and -0.0484 (95% CI: −0.0638 to −0.0297) when Modular D and Au5800 were compared. Serum Cr measured by Cobas 8000 c702 and AU5800 using the Jaffe method were 3.2% and 6.9% lower than the values measured by Modular D, respectively. Both Modular D and Cobas 8000 c702 showed acceptable accuracies.CONCLUSIONS: Serum Cr measurements using Cobas 8000 c702 and AU5800 were comparable to those measured by Modular D, and showed satisfactory precision and linearity; thus, these techniques could be useful for clinical laboratories.


Subject(s)
Creatinine , Methods
13.
Laboratory Medicine Online ; : 197-201, 2020.
Article | WPRIM (Western Pacific) | ID: wpr-836925

ABSTRACT

Background@#IgD is an immunoglobulin isotype that accounts for 100 mg/L. The established upper limit of the reference interval was 53.6 mg/L. @*Conclusions@#The SPAPLUS shows good analytical performance for serum IgD quantification.

14.
Laboratory Medicine Online ; : 185-196, 2020.
Article | WPRIM (Western Pacific) | ID: wpr-836926

ABSTRACT

The use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) in clinical laboratories is increasing and is likely to expand into even more clinical venues in the future. Mass spectrometry is the standard method for analyte identification in the clinical chemistry field; however, differences in mass spectrometry protocols and handling affect the accuracy and reliability of these tests and prevent direct comparisons of results between laboratories. For example, the results of laboratories using LC-MS/MS methods are less likely to be reproducible than those of laboratories using conventional, automated methods. This is due to inadequate handling of the equipment and/or poor quality control after the implementation of the method, which may result in unnecessary medical expenditures or even adverse outcomes for the patients. Unfortunately, guidelines to monitor the accuracy of LC-MS/MS-based clinical tests are still lacking. In general, the quality control methods used in conventional clinical tests could also be applied to LC-MS/MS. However, additional quality control methods specific to LC-MS/MS techniques must be continuously employed to maintain the same quality level achieved during method development and verification. This report is intended to help clinical laboratories that operate LC-MS/MS improve the accuracy and reliability of their testing by providing guidance for quality assurance and improvement, based on a collection of existing guidelines and expert opinions from the literature.

15.
Laboratory Medicine Online ; : 265-275, 2020.
Article in English | WPRIM (Western Pacific) | ID: wpr-902682

ABSTRACT

Background@#Therapeutic drug monitoring (TDM) is clinically recommended for vancomycin and aminoglycoside antibiotics owing to their narrow therapeutic range and nephrotoxicity at high concentrations in the blood. This study was conducted to investigate the current status of TDM of vancomycin and aminoglycosides in Korean clinical laboratories. @*Methods@#Ten organizations participated in this survey. Vancomycin, amikacin, gentamicin, and tobramycin were prepared in three samples of five or six different concentrations. Data from each institution were calculated for the mean, standard deviation, within-day, between-day, and within-laboratory precision. The results from each institution were compared in various ways. @*Results@#Six instruments from three manufacturers were used. Samples with the lowest drug concentration were reported as below the lower limit of quantitation in most laboratories. Coefficients of variation for within-laboratory values ranged from 1.1% to 10.9% for vancomycin, 0.8% to 18.2% for amikacin, 1.2% to 7.8% for gentamicin, and 1.3% to 6.1% for tobramycin. Based on the overall results of the participants, only one institution’s vancomycin samples standard deviation index exceeded 3, with all other values below 2. The College of American Pathologist criteria were met by all institutions; however, measurement of vancomycin in one laboratory and of gentamycin in three laboratories failed to meet the Royal College of Pathologists of Australasia acceptance criteria. @*Conclusions@#Although the precision of the antibiotic test in individual institutions was excellent, there was a difference in the measured values between laboratories. Harmonization of antibiotic TDM is needed to reduce inconsistencies in results.

16.
Laboratory Medicine Online ; : 265-275, 2020.
Article in English | WPRIM (Western Pacific) | ID: wpr-894978

ABSTRACT

Background@#Therapeutic drug monitoring (TDM) is clinically recommended for vancomycin and aminoglycoside antibiotics owing to their narrow therapeutic range and nephrotoxicity at high concentrations in the blood. This study was conducted to investigate the current status of TDM of vancomycin and aminoglycosides in Korean clinical laboratories. @*Methods@#Ten organizations participated in this survey. Vancomycin, amikacin, gentamicin, and tobramycin were prepared in three samples of five or six different concentrations. Data from each institution were calculated for the mean, standard deviation, within-day, between-day, and within-laboratory precision. The results from each institution were compared in various ways. @*Results@#Six instruments from three manufacturers were used. Samples with the lowest drug concentration were reported as below the lower limit of quantitation in most laboratories. Coefficients of variation for within-laboratory values ranged from 1.1% to 10.9% for vancomycin, 0.8% to 18.2% for amikacin, 1.2% to 7.8% for gentamicin, and 1.3% to 6.1% for tobramycin. Based on the overall results of the participants, only one institution’s vancomycin samples standard deviation index exceeded 3, with all other values below 2. The College of American Pathologist criteria were met by all institutions; however, measurement of vancomycin in one laboratory and of gentamycin in three laboratories failed to meet the Royal College of Pathologists of Australasia acceptance criteria. @*Conclusions@#Although the precision of the antibiotic test in individual institutions was excellent, there was a difference in the measured values between laboratories. Harmonization of antibiotic TDM is needed to reduce inconsistencies in results.

17.
Article in English | WPRIM (Western Pacific) | ID: wpr-1045693

ABSTRACT

The demand for obtaining test results using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for accurate diagnosis in the field of laboratory medicine is expected to increase, but it is still not easy to introduce diagnostic methods using LC-MS/MS into clinical laboratories for many reasons. There are many different methods used to evaluate the performance of LC-MS/MS in clinical laboratories, which have not been standardized to date. Thus, various data have been analyzed and described based on the type of validation method used and the criteria needed to introduce a new test using LC-MS/MS in a clinical laboratory. Relevant data from home and abroad were reviewed to include the minimum number of validation items required and methods of implementation. In general, the items required for a full validation of the quantitative test and various guidelines were used to summarize the following validation items: accuracy, precision, calibration, specificity, ion suppression or improvement, limit of detection, limit of quantification, stability, reference interval, carryover, and dilution integrity. Among these, the first five items mentioned beforehand are essential parameters for LC-MS/MS validation and are presented in numerous guidelines. The other parameters are required for further verification depending on the characteristics of the analysis and the analytes. This recommendation is intended to outline and present the validation methods that should be carried out when introducing new tests in clinical laboratories using LC-MS/MS with reference to the existing guidelines and literature containing expert opinions.

18.
Laboratory Medicine Online ; : 109-115, 2020.
Article in English | WPRIM (Western Pacific) | ID: wpr-1045698

ABSTRACT

Background@#Liver cirrhosis is advanced stage of hepatic brosis caused by viral hepatitis. Mac-2 binding protein glycosylation isomer (M2BPGi) is a serum marker to diagnose and evaluate hepatic brosis progression. In this study, we evaluated the efficacy of serum M2BPGi to predict chronic hepatitis B (HBV)-mediated cirrhosis by liver biopsy. @*Methods@#M2BPGi cut-off index (COI) was evaluated from 312 patients with chronic HBV-mediated hepatocellular carcinoma and 105 healthy controls. Comparative analysis was performed with conventional hepatic brosis markers such as brosis index based on four factors (FIB-4), aspartate aminotransferase-to-platelet ratio index (APRI), and Fibroscan. @*Results@#Korean Study Group for Pathology of Digestive Diseases classified 165 (52%) patients with histological stage F4 liver cirrhosis. Comparison of cases with stage F4 cirrhosis and stage F3 septal brosis revealed significant difference between M2BPGi, platelet count, APRI, FIB-4, and Fibroscan prediction. M2BPGi 2+ (COI ≥3) was found to be 8% in patients with F4 cirrhosis and 1% in patients with F3 brosis. In multi-regression analysis, M2BPGi showed higher odds ratio than that of other serum markers while M2BPGi 2+ showed comparable odds ratio to Fibroscan F3 and F4 assessment. @*Conclusions@#In patients with chronic HBV-mediated hepatocellular carcinoma, M2BPGi was neither comprehensive nor as effective as Fibroscan in assessing liver cirrhosis and brosis progression.

19.
Article in English | WPRIM (Western Pacific) | ID: wpr-760211

ABSTRACT

PURPOSE: Pompe disease (PD) is an autosomal recessive disorder caused by a deficiency of acid alpha-glucosidase resulting from pathogenic GAA variants. This study describes the clinical features, genotypes, changes before and after enzyme replacement therapy (ERT), and long-term outcomes in patients with infantile-onset PD (IOPD) and late-onset PD (LOPD) at a tertiary medical center. METHODS: The medical records of 5 Korean patients (2 male, 3 female patients) diagnosed with PD between 2002 and 2013 at Samsung Medical Center in Seoul, Republic of Korea were retrospectively reviewed for data, including clinical and genetic characteristics at diagnosis and clinical course after ERT. RESULTS: Common initial symptoms included hypotonia, cyanosis, and tachycardia in patients with IOPD and limb girdle weakness in patients with LOPD. Electrocardiography at diagnosis revealed hypertrophic cardiomyopathy in all patients with IOPD who showed a stable disease course during a median follow-up period of 10 years. Patients with LOPD showed improved hepatomegaly and liver transaminase level after ERT. CONCLUSION: As ERT is effective for treatment of PD, early identification of this disease is very important. Thus, patients with IOPD should be considered candidates for clinical trials of new drugs in the future.


Subject(s)
Child , Female , Humans , Male , alpha-Glucosidases , Cardiomyopathy, Hypertrophic , Cyanosis , Diagnosis , Electrocardiography , Enzyme Replacement Therapy , Extremities , Follow-Up Studies , Genotype , Glycogen Storage Disease Type II , Hepatomegaly , Liver , Medical Records , Muscle Hypotonia , Republic of Korea , Retrospective Studies , Seoul , Tachycardia
20.
Laboratory Medicine Online ; : 161-165, 2019.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-760500

ABSTRACT

The Clinical Mass Spectrometry Research Committee (CMSRC), in affiliation with the Korean Society of Clinical Chemistry (KSCC), conducted a questionnaire survey on opinions about the general status of clinical mass spectrometric analysis in Korea. As a result, we understand that this field has passed through the introductory stage and is settled as a field of clinical laboratory testing in Korea, with the number of new laboratories performing mass spectrometric analysis being low. In spite of the many difficulties in introducing and operating clinical mass spectrometric analysis, there is a strong interest in this field, and even though further expansion is expected, there are still many issues to be resolved. In the future, it will be necessary to make concrete and thorough efforts to further develop the laboratory tests using clinical mass spectrometric analysis in Korea, centering on the CMSRC affiliated with the KSCC.


Subject(s)
Chemistry, Clinical , Korea , Mass Spectrometry
SELECTION OF CITATIONS
SEARCH DETAIL