Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 69
Filter
1.
J Breast Imaging ; 6(2): 203-216, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38262628

ABSTRACT

Breast surgery is the cornerstone of treatment for early breast cancer. Historically, mastectomy and conventional breast-conserving surgery (BCS) were the main surgical techniques for treatment. Now, oncoplastic breast surgery (OBS), introduced in the 1990s, allows for a combination of BCS and reconstructive surgery to excise the cancer while preserving or enhancing the contour of the breast, leading to improved aesthetic results. Although imaging after conventional lumpectomy demonstrates typical postsurgical changes with known evolution patterns over time, OBS procedures show postsurgical changes/fat necrosis in locations other than the lumpectomy site. The purpose of this article is to familiarize radiologists with various types of surgical techniques for removal of breast cancer and to distinguish benign postoperative imaging findings from suspicious findings that warrant further work-up.


Subject(s)
Breast Neoplasms , Mammaplasty , Humans , Female , Mastectomy , Mastectomy, Segmental/adverse effects , Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Mammaplasty/adverse effects
2.
J Breast Imaging ; 5(6): 675-684, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38141238

ABSTRACT

OBJECTIVE: To evaluate the ability of a long-term technologist coaching program to sustain gains in mammography quality made by a previously implemented quality improvement (QI) initiative. METHODS: Mammography quality metrics from July 2014 to June 2020 were reviewed. Numbers of screening mammograms performed/audited, monthly average mammogram overall quality pass rates, changes in facilities/staffing, and technical recall rates were evaluated. Performance metrics at baseline (July 2013), during the improvement (July 2014 to January 2015), postimprovement (February 2015 to August 2015), and sustained coaching periods (after initiation of the technologist coaching model, from September 2015 to June 2020) were compared. RESULTS: During the postimprovement and sustained coaching periods, 93% (501/541) and 90% (8902/9929) of audited mammograms, respectively, met overall passing criteria, achieving or exceeding the QI goal of 90%, and results for both periods were significantly higher than that during the improvement period (74%, 1098/1489), at P < 0.0001 and P < 0.0001, respectively. The technical recall rates during the improvement and postimprovement periods were 2.6% (85/3321) and 1.7% (54/3236), respectively; the rate during the sustained coaching period was significantly lower than these, at 1.2% (489/40 440) (P < 0.0001 and P = 0.0232, respectively). Sustained quality passing rates and lower technical recall rates were observed despite statistically significantly increases in screening volumes. CONCLUSION: A technologist coaching program resulted in sustained high mammographic quality for almost 5 years.


Subject(s)
Mentoring , Mammography , Quality Improvement , Benchmarking , Early Detection of Cancer
4.
J Breast Imaging ; 4(4): 371-377, 2022 Jul 29.
Article in English | MEDLINE | ID: mdl-38416983

ABSTRACT

OBJECTIVE: To evaluate breast density notification legislation (BDNL) on breast imaging practice patterns, risk assessment, and supplemental screening. METHODS: A 20-question anonymous web-based survey was administered to practicing Society of Breast Imaging radiologists in the U.S. between February and April 2021 regarding breast cancer risk assessment, supplemental screening, and density measurements. Results were compared between facilities with and without BDNL using the two-sided Fisher's exact test. RESULTS: One hundred and ninety-seven radiologists from 41 U.S. states, with (187/197, 95%) or without (10/197, 5%) BDNL, responded. Fifty-seven percent (113/197) performed breast cancer risk assessment, and 93% (183/197) offered supplemental screening for women with dense breasts. Between facilities with or without BDNL, there was no significant difference in whether risk assessment was (P = 0.19) or was not performed (P = 0.20). There was no significant difference in supplemental screening types (P > 0.05) between BDNL and non-BDNL facilities. Thirty-five percent (69/197) of facilities offered no supplemental screening studies, and 25% (49/197) had no future plans to offer supplemental screening. A statistically significant greater proportion of non-BDNL facilities offered no supplemental screening (P < 0.03) and had no plans to offer supplemental screening compared to BDNL facilities (P < 0.02). CONCLUSION: Facilities in BDNL states often offer supplemental screening compared to facilities in non-BDNL states. Compared to BDNL facilities, a statistically significant proportion of non-BDNL facilities had no supplemental screening nor plans for implementation. Our data suggest that upcoming federal BDNL will impact how supplemental screening is addressed in currently non-BDNL states.

5.
Diagnostics (Basel) ; 11(7)2021 Jul 15.
Article in English | MEDLINE | ID: mdl-34359350

ABSTRACT

Dedicated breast positron emission tomography (dbPET) is a new diagnostic imaging modality recently used in clinical practice for the detection of breast cancer and the assessment of tumor biology. dbPET has higher spatial resolution than that of conventional whole body PET systems, allowing recognition of detailed morphological attributes of radiotracer accumulation within the breast. 18F-fluorodeoxyglucose (18F-FDG) accumulation in the breast may be due to benign or malignant entities, and recent studies suggest that morphology characterization of 18F-FDG uptake could aid in estimating the probability of malignancy. However, across the world, there are many descriptors of breast 18F-FDG uptake, limiting comparisons between studies. In this article, we propose a lexicon for breast radiotracer uptake to standardize description and reporting of image findings on dbPET, consisting of terms for image quality, radiotracer fibroglandular uptake, breast lesion uptake.

6.
J Breast Imaging ; 3(3): 354-362, 2021.
Article in English | MEDLINE | ID: mdl-34056594

ABSTRACT

OBJECTIVE: To determine the impact of the COVID-19 pandemic on breast imaging education. METHODS: A 22-item survey addressing four themes during the early pandemic (time on service, structured education, clinical training, future plans) was emailed to Society of Breast Imaging members and members-in-training in July 2020. Responses were compared using McNemar's and Mann-Whitney U tests; a general linear model was used for multivariate analysis. RESULTS: Of 136 responses (136/2824, 4.8%), 96 U.S. responses from radiologists with trainees, residents, and fellows were included. Clinical exposure declined during the early pandemic, with almost no medical students on service (66/67, 99%) and fewer clinical days for residents (78/89, 88%) and fellows (48/68, 71%). Conferences shifted to remote live format (57/78, 73%), with some canceled (15/78, 19%). Compared to pre-pandemic, resident diagnostic (75/78, 96% vs 26/78, 33%) (P < 0.001) and procedural (73/78, 94% vs 21/78, 27%) (P < 0.001) participation fell, as did fellow diagnostic (60/61, 98% vs 47/61, 77%) (P = 0.001) and procedural (60/61, 98% vs 43/61, 70%) (P < 0.001) participation. Most thought that the pandemic negatively influenced resident and fellow screening (64/77, 83% and 43/60, 72%, respectively), diagnostic (66/77, 86% and 37/60, 62%), and procedural (71/77, 92% and 37/61, 61%) education. However, a majority thought that decreased time on service (36/67, 54%) and patient contact (46/79, 58%) would not change residents' pursuit of a breast imaging fellowship. CONCLUSION: The pandemic has had a largely negative impact on breast imaging education, with reduction in exposure to all aspects of breast imaging. However, this may not affect career decisions.

7.
Eur J Radiol ; 139: 109686, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33819803

ABSTRACT

PURPOSE: To validate a candidate instrument, to be used by different professionals to assess image quality in digital mammography (DM), against detection performance results. METHODS: A receiver operating characteristics (ROC) study was conducted to assess the detection performance in DM images with four different image quality levels due to different quality issues. Fourteen expert breast radiologists from five countries assessed a set of 80 DM cases, containing 60 lesions (40 cancers, 20 benign findings) and 20 normal cases. A visual grading analysis (VGA) study using a previously-described candidate instrument was conducted to evaluate a subset of 25 of the images used in the ROC study. Eight radiologists that had participated in the ROC study, and seven expert breast-imaging physicists, evaluated this subset. The VGA score (VGAS) and the ROC and visual grading characteristics (VGC) areas under the curve (AUCROC and AUCVGC) were compared. RESULTS: No large differences in image quality among the four levels were detected by either ROC or VGA studies. However, the ranking of the four levels was consistent: level 1 (partial AUCROC: 0.070, VGAS: 6.77) performed better than levels 2 (0.066, 6.15), 3 (0.061, 5.82), and 4 (0.062, 5.37). Similarity between radiologists' and physicists' assessments was found (average VGAS difference of 10 %). CONCLUSIONS: The results from the candidate instrument were found to correlate with those from ROC analysis, when used by either observer group. Therefore, it may be used by different professionals, such as radiologists, radiographers, and physicists, to assess clinically-relevant image quality variations in DM.


Subject(s)
Breast Neoplasms , Mammography , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Humans , ROC Curve , Radiographic Image Enhancement , Radiologists
8.
Radiology ; 299(3): 559-567, 2021 06.
Article in English | MEDLINE | ID: mdl-33825509

ABSTRACT

Background Interval cancer rates can be used to evaluate whether screening with digital breast tomosynthesis (DBT) contributes to a screening benefit. Purpose To compare interval cancer rates and tumor characteristics in DBT screening to those in a contemporary population screened with digital mammography (DM). Materials and Methods The prospective population-based Malmö Breast Tomosynthesis Screening Trial (MBTST) was designed to compare one-view DBT to two-view DM in breast cancer detection. The interval cancer rates and cancer characteristics in the MBTST were compared with an age-matched contemporary control group, screened with two-view DM at the same center. Conditional logistic regression was used for data analysis. Results There were 14 848 women who were screened with DBT and DM in the MBTST between January 2010 and February 2015. The trial women were matched with two women of the same age and screening occasion at DM screening during the same period. Matches for 13 369 trial women (mean age, 56 years ± 10 [standard deviation]) were found with 26 738 women in the control group (mean age, 56 years ± 10). The interval cancer rate in the MBTST was 1.6 per 1000 screened women (21 of 13 369; 95% CI: 1.0, 2.4) compared with 2.8 per 1000 screened women in the control group (76 of 26 738 [95% CI: 2.2, 3.6]; conditional odds ratio, 0.6 [95% CI: 0.3, 0.9]; P = .02). The invasive interval cancers in the MBTST and in the control group showed in general high Ki-67 (63% [12 of 19] and 75% [54 of 72]), and low proportions of luminal A-like subtype (26% [five of 19] and 17% [12 of 72]), respectively. Conclusion The reduced interval cancer rate after screening with digital breast tomosynthesis compared with a contemporary age-matched control group screened with digital mammography might translate into screening benefits. Interval cancers in the trial generally had nonfavorable characteristics. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Mann in this issue.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/epidemiology , Mammography/methods , Mass Screening/methods , Adult , Aged , Breast Neoplasms/pathology , Early Detection of Cancer , Female , Humans , Middle Aged , Prospective Studies , Sweden/epidemiology
9.
Eur Radiol ; 31(7): 5335-5343, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33475774

ABSTRACT

OBJECTIVES: To study how radiologists' perceived ability to interpret digital mammography (DM) images is affected by decreases in image quality. METHODS: One view from 45 DM cases (including 30 cancers) was degraded to six levels each of two acquisition-related issues (lower spatial resolution and increased quantum noise) and three post-processing-related issues (lower and higher contrast and increased correlated noise) seen during clinical evaluation of DM systems. The images were shown to fifteen breast screening radiologists from five countries. Aware of lesion location, the radiologists selected the most-degraded mammogram (indexed from 1 (reference) to 7 (most degraded)) they still felt was acceptable for interpretation. The median selected index, per degradation type, was calculated separately for calcification and soft tissue (including normal) cases. Using the two-sided, non-parametric Mann-Whitney test, the median indices for each case and degradation type were compared. RESULTS: Radiologists were not tolerant to increases (medians: 1.5 (calcifications) and 2 (soft tissue)) or decreases (median: 2, for both types) in contrast, but were more tolerant to correlated noise (median: 3, for both types). Increases in quantum noise were tolerated more for calcifications than for soft tissue cases (medians: 3 vs. 4, p = 0.02). Spatial resolution losses were considered less acceptable for calcification detection than for soft tissue cases (medians: 3.5 vs. 5, p = 0.001). CONCLUSIONS: Perceived ability of radiologists for image interpretation in DM was affected not only by image acquisition-related issues but also by image post-processing issues, and some of those issues affected calcification cases more than soft tissue cases. KEY POINTS: • Lower spatial resolution and increased quantum noise affected the radiologists' perceived ability to interpret calcification cases more than soft tissue lesion or normal cases. • Post-acquisition image processing-related effects, not only image acquisition-related effects, also impact the perceived ability of radiologists to interpret images and detect lesions. • In addition to current practices, post-acquisition image processing-related effects need to also be considered during the testing and evaluation of digital mammography systems.


Subject(s)
Breast Neoplasms , Calcinosis , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Female , Humans , Mammography , Radiographic Image Enhancement , Radiologists
10.
Br J Radiol ; 94(1118): 20201166, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33332980

ABSTRACT

OBJECTIVE: To compare positive predictive values (PPVs) of clumped vs non-clumped (homogenous and heterogeneous) internal enhancement on MRI detected linear non-mass enhancement (NME) on MRI-guided vacuum-assisted breast biopsy (MRI-VABB). METHODS: With IRB (Institutional Review Board) approval, we retrospectively reviewed 598 lesions undergoing MRI-VABB from January 2015 to April 2018 that showed linear NME. We reviewed the electronic medical records for MRI-VABB pathology, any subsequent surgery and clinical follow-up. The X2 test was performed for univariate analysis. RESULTS: There were 120/598 (20%) linear NME MRI-VABB lesions with clumped (52/120, 43%) vs non-clumped (68/120, 57%) internal enhancement, average size 1.8 cm (range 0.6-7.6 cm). On MRI-VABB, cancer was identified in 22/120 (18%) lesions, ductal carcinoma in situ (DCIS) was found in 18/22 (82%) and invasive cancer in 4 (18%). 3/31 (10%) high-risk lesions upgraded to DCIS at surgery, for a total of 25/120 (21%) malignancies. Malignancy was found in 12/52 (23%) clumped lesions and in 13/68 (19%) of non-clumped lesions that showed heterogeneous (5/13, 38%) or homogenous (8/13, 62%) internal enhancement. The PPV of linear NME with clumped internal enhancement (23.1%) was not significantly different from the PPV of non-clumped linear NME (19.1%) (p = 0.597). The PPV of linear NME lesions <1 cm (33.3%) was not significantly different from the PPV of lesions ≥1 cm (18.6%) (p = 0.157). CONCLUSIONS: Linear NME showed malignancy in 21% of our series. Linear NME with clumped or non-clumped internal enhancement patterns, regardless of lesion size, might need to undergo MRI-VABB in appropriate populations. ADVANCES IN KNOWLEDGE: Evaluation of linear NME lesions on breast MRI focuses especially on internal enhancement pattern.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Breast/diagnostic imaging , Breast/pathology , Female , Humans , Image-Guided Biopsy , Middle Aged , Retrospective Studies , Vacuum
11.
Eur J Radiol ; 134: 109464, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33307458

ABSTRACT

PURPOSE: To develop a candidate instrument to assess image quality in digital mammography, by identifying clinically relevant features in images that are affected by lower image quality. METHODS: Interviews with fifteen expert breast radiologists from five countries were conducted and analysed by using adapted directed content analysis. During these interviews, 45 mammographic cases, containing 44 lesions (30 cancers, 14 benign findings), and 5 normal cases, were shown with varying image quality. The interviews were performed to identify the structures from breast tissue and lesions relevant for image interpretation, and to investigate how image quality affected the visibility of those structures. The interview findings were used to develop tentative items, which were evaluated in terms of wording, understandability, and ambiguity with expert breast radiologists. The relevance of the tentative items was evaluated using the content validity index (CVI) and modified kappa index (k*). RESULTS: Twelve content areas, representing the content of image quality in digital mammography, emerged from the interviews and were converted into 29 tentative items. Fourteen of these items demonstrated excellent CVI ≥ 0.78 (k* > 0.74), one showed good CVI < 0.78 (0.60 ≤ k* ≤ 0.74), while fourteen were of fair or poor CVI < 0.78 (k* ≤ 0.59). In total, nine items were deleted and five were revised or combined resulting in 18 items. CONCLUSIONS: By following a mixed-method methodology, a candidate instrument was developed that may be used to characterise the clinically-relevant impact that image quality variations can have on digital mammography.


Subject(s)
Breast , Mammography , Humans , Reproducibility of Results , Research Design
12.
J Magn Reson Imaging ; 53(3): 807-817, 2021 03.
Article in English | MEDLINE | ID: mdl-33067849

ABSTRACT

BACKGROUND: Diffusion-weighted imaging (DWI) has shown promise to screen for breast cancer without a contrast injection, but image distortion and low spatial resolution limit standard single-shot DWI. Multishot DWI methods address these limitations but introduce shot-to-shot phase variations requiring correction during reconstruction. PURPOSE: To investigate the performance of two multishot DWI reconstruction methods, multiplexed sensitivity encoding (MUSE) and shot locally low-rank (shot-LLR), compared to single-shot DWI in the breast. STUDY TYPE: Prospective. POPULATION: A total of 45 women who consented to have multishot DWI added to a clinically indicated breast MRI. FIELD STRENGTH/SEQUENCES: Single-shot DWI reconstructed by parallel imaging, multishot DWI with four or eight shots reconstructed by MUSE and shot-LLR, 3D T2 -weighted imaging, and contrast-enhanced MRI at 3T. ASSESSMENT: Three blinded observers scored images for 1) general image quality (perceived signal-to-noise ratio [SNR], ghosting, distortion), 2) lesion features (discernment and morphology), and 3) perceived resolution. Apparent diffusion coefficient (ADC) of the lesion was also measured and compared between methods. STATISTICAL TESTS: Image quality features and perceived resolution were assessed with a mixed-effects logistic regression. Agreement among observers was estimated with a Krippendorf's alpha using linear weighting. Lesion feature ratings were visualized using histograms, and correlation coefficients of lesion ADC between different methods were calculated. RESULTS: MUSE and shot-LLR images were rated to have significantly better perceived resolution (P < 0.001), higher SNR (P < 0.005), and a lower level of distortion (P < 0.05) with respect to single-shot DWI. Shot-LLR showed reduced ghosting artifacts with respect to both MUSE (P < 0.001) and single-shot DWI (P < 0.001). Eight-shot DWI had improved perceived SNR and perceived resolution with respect to four-shot DWI (P < 0.005). DATA CONCLUSION: Multishot DWI enables increased resolution and improved image quality with respect to single-shot DWI in the breast. Shot-LLR reconstructs multishot DWI with minimal ghosting artifacts. The improvement of multishot DWI in image quality increases with an increased number of shots. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Subject(s)
Diffusion Magnetic Resonance Imaging , Echo-Planar Imaging , Artifacts , Female , Humans , Magnetic Resonance Imaging , Prospective Studies , Reproducibility of Results
13.
J Breast Imaging ; 3(3): 343-353, 2021 May 21.
Article in English | MEDLINE | ID: mdl-38424771

ABSTRACT

OBJECTIVE: To determine the early impact of the COVID-19 pandemic on breast imaging centers in California and Texas and compare regional differences. METHODS: An 11-item survey was emailed to American College of Radiology accredited breast imaging facilities in California and Texas in August 2020. A question subset addressed March-April government restrictions on elective services ("during the shutdown" and "after reopening"). Comparisons were made between states with chi-square and Fisher's tests, and timeframes with McNemar's and paired t-tests. RESULTS: There were 54 respondents (54/240, 23%, 26 California, 28 Texas). Imaging volumes fell during the shutdown and remained below pre-pandemic levels after reopening, with reduction in screening greatest (ultrasound 12% of baseline, mammography 13%, MRI 23%), followed by diagnostic MRI (43%), procedures (44%), and diagnostics (45%). California reported higher volumes during the shutdown (procedures, MRI) and after reopening (diagnostics, procedures, MRI) versus Texas (P = 0.001-0.02). Most screened patients (52/54, 96% symptoms and 42/54, 78% temperatures), and 100% (53/53) modified check-in and check-out. Reading rooms or physician work were altered for social distancing (31/54, 57%). Physician mask (45/48, 94%), gown (15/48, 31%), eyewear (22/48, 46%), and face shield (22/48, 46%) use during procedures increased after reopening versus pre-pandemic (P < 0.001-0.03). Physician (47/54, 87%) and staff (45/53, 85%) financial impacts were common, but none reported terminations. CONCLUSION: Breast imaging volumes during the early pandemic fell more severely in Texas than in California. Safety measures and financial impacts on physicians and staff were similar in both states.

14.
Breast J ; 26(9): 1838-1840, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32304610
15.
Breast Cancer ; 27(3): 405-414, 2020 May.
Article in English | MEDLINE | ID: mdl-31838725

ABSTRACT

BACKGROUND: To evaluate imaging characteristics, outcome of surgical excision or imaging follow-up on high-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy (MRI-VABB). METHODS: We retrospectively reviewed 598 lesions undergoing 9-gauge MRI-VABB from January 2015 to April 2018 to identify high risk breast lesions. We collected patient demographics, breast MRI BI-RADS descriptors, histopathological diagnosis at MRI-VABB and surgical excision, frequency of upgrade to malignancy and imaging follow-up of high-risk lesions. The x2 test and Fisher exact tests were performed for univariate analysis. RESULTS: 114 patients with 124/598 findings (20.7%) had high-risk lesions at MRI-VABB, including atypical ductal hyperplasia (ADH) (21/124, 16.9%), lobular neoplasia (40/124, 32.3%), radial scar/complex sclerosing lesion (RS/CSL) (13/124, 10.5%), papillary lesions (49/124, 39.5%), and flat epithelial atypia (FEA) (1/124, 0.8%). 84/124 (67.7%) high-risk lesions were excised. 19/84 (22.6%) were upgraded to malignancy (7 invasive cancer, 12 DCIS). The upgrade rate for ADH and lobular neoplasia was 7/18 (38.9%) and 9/31 (29.0%), respectively. The upgrade rate for RS/CSL was 1/10 (10%). Of the 25 papillary lesions excised, 2 (8%) demonstrated pathologic atypia and were upgraded to DCIS. The other 23 papillary lesions had no upgrade or atypia. Excised high-risk lesions showing upgrade varied from 0.4 to 6 cm in length (mean 1.6 cm). There was a non-significant trend (p = 0.054) between larger lesion and upgrade to malignancy; however, there were no other specific imaging features to predict malignancy upgrade. CONCLUSIONS: There were no specific MRI imaging characteristics of high-risk lesions to predict malignancy upgrade. Therefore, surgical excision is recommended for high-risk lesions, especially ADH or lobular neoplasia.


Subject(s)
Breast Neoplasms/pathology , Carcinoma, Ductal, Breast/pathology , Carcinoma, Intraductal, Noninfiltrating/pathology , Carcinoma, Lobular/pathology , Image-Guided Biopsy/methods , Magnetic Resonance Imaging/methods , Mammography/methods , Adult , Aged , Aged, 80 and over , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/surgery , Carcinoma, Intraductal, Noninfiltrating/surgery , Carcinoma, Lobular/surgery , Female , Follow-Up Studies , Humans , Lymphatic Metastasis , Middle Aged , Neoplasm Invasiveness , Prognosis , Retrospective Studies , Vacuum , Young Adult
16.
J Breast Imaging ; 2(2): 141-146, 2020 Mar 25.
Article in English | MEDLINE | ID: mdl-38424890

ABSTRACT

OBJECTIVE: Fibrocystic change (FCC) is considered one of the most common benign findings in the breast and may be commonly seen on breast MRI. We performed this study to identify MRI characteristics of pure FCC on MRI-guided vacuum-assisted breast biopsy (VABB) without other associated pathologies and describe the findings on MRI follow-up and outcomes. METHODS: A retrospective review was performed for 598 lesions undergoing 9-gauge MRI-guided VABB at our institution from January 2015 to April 2018, identifying 49 pure FCC lesions in 43 patients. The associations between variables and lesion changes on follow-up MRI were analyzed using exact Mann-Whitney tests and Fisher's exact tests. RESULTS: MRI features of pure FCC are predominantly clumped nonmass enhancement (19/49, 39%) or irregular masses with initial fast/late washout kinetics (9/49, 18%). There was no upgrade to high-risk or cancerous lesions among the 11 patients (25.6%) who underwent surgery. There were 22 pure FCC lesions in 19 (44.2%) patients who had follow-up MRI (mean 18.0 months, range 11-41 months) showing regression (13, 59%), stability (8, 36%), or progression (1, 5%) of the lesion size, and no cancers were found on follow-up at the site of the MRI biopsy for fibrocystic changes. No patient demographics or lesion features were associated with lesion regression or stability (P > 0.05). CONCLUSION: Our study shows that MRI features of VABB-proven FCC lesions may mimic malignancy. After VABB of pure FCC, given that adequate sampling has been performed, a 12-month follow-up MRI may be reasonable.

18.
AJR Am J Roentgenol ; 210(4): 807-815, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29412019

ABSTRACT

OBJECTIVE: The purpose of this project was to achieve sustained improvement in mammographic breast positioning in our department. MATERIALS AND METHODS: Between June 2013 and December 2016, we conducted a team-based performance improvement initiative with the goal of improving mammographic positioning. The team of technologists and radiologists established quantitative measures of positioning performance based on American College of Radiology (ACR) criteria, audited at least 35 mammograms per week for positioning quality, displayed performance in dashboards, provided technologists with positioning training, developed a supportive environment fostering technologist and radiologist communication surrounding mammographic positioning, and employed a mammography positioning coach to develop, improve, and maintain technologist positioning performance. Statistical significance in changes in the percentage of mammograms passing the ACR criteria were evaluated using a two-proportion z test. RESULTS: A baseline mammogram audit performed in June 2013 showed that 67% (82/122) met ACR passing criteria for positioning. Performance improved to 80% (588/739; p < 0.01) after positioning training and technologist and radiologist agreement on positioning criteria. With individual technologist feedback, positioning further improved, with 91% of mammograms passing ACR criteria (p < 0.01). Seven months later, performance temporarily decreased to 80% but improved to 89% with implementation of a positioning coach. The overall mean performance of 91% has been sustained for 23 months. The program cost approximately $30,000 to develop, $42,000 to launch, and $25,000 per year to maintain. Almost all costs were related to personnel time. CONCLUSION: Dedicated performance improvement methods may achieve significant and sustained improvement in mammographic breast positioning, which may better enable facilities to pass the recently instated Enhancing Quality Using the Inspection Program portion of a practice's annual Mammography Quality Standards Act inspections.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography/standards , Mass Screening/standards , Patient Positioning , Quality Improvement , Radiology/education , Academic Medical Centers , Female , Humans , Inservice Training
19.
Breast Cancer Res Treat ; 169(3): 437-446, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29423901

ABSTRACT

PURPOSE: Premenopausal physiologic steroid levels change cyclically, in contrast to steady state low levels seen in postmenopausal patients. The purpose of this study was to evaluate whether 18F-fluorodeoxyglucose (18F-FDG) uptake in breast cancer is influenced by physiological hormonal fluctuations. METHODS: A total of 160 primary invasive breast cancers from 155 females (54 premenopausal, 101 postmenopausal) who underwent 18F-FDG positron emission tomography/computed tomography before therapy were retrospectively analyzed. The maximal standardized uptake values (SUVmax) of tumors were compared with menstrual phases and menopausal status according to the following subgroups: 'luminal A-like,' 'luminal B-like,' and 'non-luminal.' Additionally, the effect of estradiol (E2) on 18F-FDG uptake in breast cancer cells was evaluated in vitro. RESULTS: Among premenopausal patients, SUVmax during the periovulatory-luteal phase was significantly higher than that during the follicular phase in luminal A-like tumors (n = 25, p = 0.004), while it did not differ between the follicular phase and the periovulatory-luteal phase in luminal B-like (n = 24) and non-luminal tumors (n = 7). Multiple regression analysis showed menstrual phase, tumor size, and Ki-67 index are independent predictors for SUVmax in premenopausal luminal A-like tumors. There were no significant differences in SUVmax between pre- and postmenopausal patients in any of the subgroups. In in vitro studies, uptake in estrogen receptor-positive cells was significantly augmented when E2 concentration was increased from 0.01 to ≥ 1 nM. CONCLUSIONS: Our data suggest that 18F-FDG uptake may be impacted by physiological hormonal fluctuations during menstrual cycle in luminal A-like cancers, and that E2 could be partly responsible for these events.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/metabolism , Fluorodeoxyglucose F18/metabolism , Hormones/metabolism , Positron-Emission Tomography , Adult , Aged , Biomarkers , Breast Neoplasms/pathology , Cell Line, Tumor , Female , Humans , Menstrual Cycle , Middle Aged , Positron Emission Tomography Computed Tomography , Postmenopause , Premenopause , Risk Factors
20.
Radiology ; 285(2): 401-413, 2017 11.
Article in English | MEDLINE | ID: mdl-28708462

ABSTRACT

Purpose To identify the molecular basis of quantitative imaging characteristics of tumor-adjacent parenchyma at dynamic contrast material-enhanced magnetic resonance (MR) imaging and to evaluate their prognostic value in breast cancer. Materials and Methods In this institutional review board-approved, HIPAA-compliant study, 10 quantitative imaging features depicting tumor-adjacent parenchymal enhancement patterns were extracted and screened for prognostic features in a discovery cohort of 60 patients. By using data from The Cancer Genome Atlas (TCGA), a radiogenomic map for the tumor-adjacent parenchymal tissue was created and molecular pathways associated with prognostic parenchymal imaging features were identified. Furthermore, a multigene signature of the parenchymal imaging feature was built in a training cohort (n = 126), and its prognostic relevance was evaluated in two independent cohorts (n = 879 and 159). Results One image feature measuring heterogeneity (ie, information measure of correlation) was significantly associated with prognosis (false-discovery rate < 0.1), and at a cutoff of 0.57 stratified patients into two groups with different recurrence-free survival rates (log-rank P = .024). The tumor necrosis factor signaling pathway was identified as the top enriched pathway (hypergeometric P < .0001) among genes associated with the image feature. A 73-gene signature based on the tumor profiles in TCGA achieved good association with the tumor-adjacent parenchymal image feature (R2 = 0.873), which stratified patients into groups regarding recurrence-free survival (log-rank P = .029) and overall survival (log-rank P = .042) in an independent TCGA cohort. The prognostic value was confirmed in another independent cohort (Gene Expression Omnibus GSE 1456), with log-rank P = .00058 for recurrence-free survival and log-rank P = .0026 for overall survival. Conclusion Heterogeneous enhancement patterns of tumor-adjacent parenchyma at MR imaging are associated with the tumor necrosis signaling pathway and poor survival in breast cancer. © RSNA, 2017 Online supplemental material is available for this article.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/mortality , Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging , Parenchymal Tissue/diagnostic imaging , Adult , Aged , Biomarkers, Tumor/analysis , Biomarkers, Tumor/genetics , Biomarkers, Tumor/metabolism , Breast Neoplasms/chemistry , Breast Neoplasms/genetics , Female , Gene Expression Profiling , Genomics , Humans , Kaplan-Meier Estimate , Middle Aged , Molecular Imaging , Parenchymal Tissue/chemistry , Prognosis , Signal Transduction
SELECTION OF CITATIONS
SEARCH DETAIL
...