Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 112
Filter
1.
ASAIO J ; 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701397

ABSTRACT

The objective was to investigate the outcomes of concomitant venoarterial extracorporeal membrane oxygenation (ECMO) and left ventricular unloading with Impella (ECPELLA) compared with ECMO alone to treat patients affected by cardiogenic shock. Data from patients needing mechanical circulatory support from 4 international centers were analyzed. Of 438 patients included, ECMO alone and ECPELLA were adopted in 319 (72.8%) and 119 (27.2%) patients, respectively. Propensity score matching analysis identified 95 pairs. In the matched cohort, 30-day mortality rates in the ECMO and ECPELLA were 49.5% and 43.2% ( P = 0.467). The incidences of complications did not differ significantly between groups ( P = 0.877, P = 0.629, P = 1.000, respectively). After a median follow-up of 0.18 years (interquartile range 0.02-2.55), the use of ECPELLA was associated with similar mortality compared with ECMO alone (hazard ratio 0.81, 95% confidence interval 0.54-1.20, P = 0.285), with 1-year overall survival rates of 51.3% and 46.6%, for ECPELLA and ECMO alone, respectively. ECMO alone and ECPELLA are both effective strategies in patients needing mechanical circulatory support for cardiogenic shock, showing similar rates of early and mid-term survival.

4.
Atherosclerosis ; 386: 117363, 2023 12.
Article in English | MEDLINE | ID: mdl-37944269

ABSTRACT

BACKGROUND AND AIMS: Artificial intelligence quantitative CT (AI-QCT) determines coronary plaque morphology with high efficiency and accuracy. Yet, its performance to quantify lipid-rich plaque remains unclear. This study investigated the performance of AI-QCT for the detection of low-density noncalcified plaque (LD-NCP) using near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS). METHODS: The INVICTUS Registry is a multi-center registry enrolling patients undergoing clinically indicated coronary CT angiography and IVUS, NIRS-IVUS, or optical coherence tomography. We assessed the performance of various Hounsfield unit (HU) and volume thresholds of LD-NCP using maxLCBI4mm ≥ 400 as the reference standard and the correlation of the vessel area, lumen area, plaque burden, and lesion length between AI-QCT and IVUS. RESULTS: This study included 133 atherosclerotic plaques from 47 patients who underwent coronary CT angiography and NIRS-IVUS The area under the curve of LD-NCP<30HU was 0.97 (95% confidence interval [CI]: 0.93-1.00] with an optimal volume threshold of 2.30 mm3. Accuracy, sensitivity, and specificity were 94% (95% CI: 88-96%], 93% (95% CI: 76-98%), and 94% (95% CI: 88-98%), respectively, using <30 HU and 2.3 mm3, versus 42%, 100%, and 27% using <30 HU and >0 mm3 volume of LD-NCP (p < 0.001 for accuracy and specificity). AI-QCT strongly correlated with IVUS measurements; vessel area (r2 = 0.87), lumen area (r2 = 0.87), plaque burden (r2 = 0.78) and lesion length (r2 = 0.88), respectively. CONCLUSIONS: AI-QCT demonstrated excellent diagnostic performance in detecting significant LD-NCP using maxLCBI4mm ≥ 400 as the reference standard. Additionally, vessel area, lumen area, plaque burden, and lesion length derived from AI-QCT strongly correlated with respective IVUS measurements.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Plaque, Atherosclerotic/diagnosis , Coronary Artery Disease/diagnosis , Artificial Intelligence , Spectroscopy, Near-Infrared , Ultrasonography, Interventional/methods , Tomography, X-Ray Computed/methods , Coronary Angiography/methods , Computed Tomography Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Lipids , Predictive Value of Tests
5.
J Cardiovasc Comput Tomogr ; 17(6): 401-406, 2023.
Article in English | MEDLINE | ID: mdl-37679247

ABSTRACT

BACKGROUND: Coronary CT angiography (CCTA) is a first-line noninvasive imaging modality for evaluating coronary artery disease (CAD). Recent advances in CCTA technology enabled semi-automated detection of coronary arteries and atherosclerosis. However, there have been to date no large-scale validation studies of automated assessment of coronary atherosclerosis phenotype and coronary artery dimensions by artificial intelligence (AI) compared to current standard invasive imaging. METHODS: INVICTUS registry is a multicenter, retrospective, and prospective study designed to evaluate the dimensions of coronary arteries, as well as the characteristic, volume, and phenotype of coronary atherosclerosis by CCTA, compared with the invasive imaging modalities including intravascular ultrasound (IVUS), near-infrared spectroscopy (NIRS)-IVUS and optical coherence tomography (OCT). All patients clinically underwent both CCTA and invasive imaging modalities within three months. RESULTS: Patients data are sent to the core-laboratories to analyze for stenosis severity, plaque characteristics and volume. The variables for CCTA are measured using an AI-based automated software and assessed independently with the variables measured at the imaging core laboratories for IVUS, NIRS-IVUS, and OCT in a blind fashion. CONCLUSION: The INVICTUS registry will provide new insights into the diagnostic value of CCTA for determining coronary atherosclerosis phenotype and coronary artery dimensions compared to IVUS, NIRS-IVUS, and OCT. Our findings will potentially shed new light on precision medicine informed by an AI-based coronary CTA assessment of coronary atherosclerosis burden, composition, and severity. (ClinicalTrials.gov: NCT04066062).


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Coronary Artery Disease/diagnostic imaging , Computed Tomography Angiography , Tomography, Optical Coherence , Artificial Intelligence , Prospective Studies , Retrospective Studies , Ultrasonography, Interventional/methods , Predictive Value of Tests , Coronary Angiography/methods , Coronary Vessels/diagnostic imaging
8.
Heart Vessels ; 38(9): 1095-1107, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37004540

ABSTRACT

Fractional flow reserve (FFR) derived off-site by coronary computed tomography angiography (CCTA) (FFRCT) is obtained by applying the principles of computational fluid dynamics. This study aimed to validate the overall reliability of on-site CCTA-derived FFR based on fluid structure interactions (CT-FFR) and assess its clinical utility compared with FFRCT, invasive FFR, and resting full-cycle ratio (RFR). We calculated the CT-FFR for 924 coronary vessels in 308 patients who underwent CCTA for clinically suspected coronary artery disease. Of these patients, 35 patients with at least one obstructive stenosis (> 50%) detected on CCTA underwent both CT-FFR and FFRCT for further investigation. Furthermore, 24 and 20 patients underwent invasive FFR and RFR in addition to CT-FFR, respectively. The inter-observer correlation (r) of CT-FFR was 0.93 (95% confidence interval [CI] 0.85-0.97, P < 0.0001) with a mean absolute difference of - 0.0042 (limits of agreement - 0.073, 0.064); 97.3% of coronary arteries without obstructive lesions on CCTA had negative results for ischemia on CT-FFR (> 0.80). The correlation coefficient between CT-FFR and FFRCT for 105 coronary vessels was 0.87 (95% CI 0.82-0.91, P < 0.0001) with a mean absolute difference of - 0.012 (limits of agreement - 0.12, 0.10). CT-FFR correlated well with both invasive FFR (r = 0.66, 95% CI 0.36-0.84, P = 0.0003) and RFR (r = 0.78, 95% CI 0.51-0.91, P < 0.0001). These data suggest that CT-FFR can potentially substitute for FFRCT and correlates closely with invasive FFR and RFR with high reproducibility. Our findings should be proven by further clinical investigation in a larger cohort.


Subject(s)
Coronary Artery Disease , Coronary Vessels , Fractional Flow Reserve, Myocardial , Hydrodynamics , Predictive Value of Tests , Reproducibility of Results , Computed Tomography Angiography , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Humans , Middle Aged , Aged , Aged, 80 and over , Male , Female
9.
Intern Med ; 62(24): 3591-3599, 2023 Dec 15.
Article in English | MEDLINE | ID: mdl-37121753

ABSTRACT

Objective The index of microvascular resistance (IMR) is an invasive method for quantifying the coronary microvasculature independent of the presence and degree of epicardial stenosis during cardiac catheterization, whereas the Selvester QRS score, which is related to myocardial damage, is a relatively simple and non-invasive measurement procedure. We investigated the relationship between the QRS score and coronary microvascular dysfunction (CMD) assessed via IMR. Methods Data from 74 patients who underwent invasive coronary physiological measurements were retrospectively reviewed. Using a coronary wire, we measured IMR by the hyperemic mean transit time and distal coronary pressure. We also determined a simplified QRS score following the Selvester QRS score criteria by 12-lead electrocardiography. After determining the best cutoff value for the QRS score to predict IMR ≥25, which was defined as CMD by the Coronary Vasomotion Disorders International Study Group, patients were categorized into the QRS score ≥3 (n=16) and the QRS score 0-2 (n=58) groups. Results IMR in the QRS score ≥3 group was significantly higher in comparison to the QRS score 0-2 group (31; IQR: 19-57 vs. 20; IQR: 14-29, p<0.01). The percentage of patients with IMR ≥25 in the QRS score ≥3 group was significantly higher than that in the QRS score 0-2 group (69% vs. 34%, p=0.01). Conclusion A higher QRS score was associated with CMD, as estimated by IMR. The Selvester QRS score is noninvasive parameter that is potentially useful for predicting CMD.


Subject(s)
Myocardial Ischemia , Humans , Microcirculation/physiology , Retrospective Studies , Myocardium , Heart , Vascular Resistance , Predictive Value of Tests
10.
Heart Vessels ; 38(8): 1083-1091, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36928668

ABSTRACT

Trans-catheter aortic valve replacement (TAVR) is an excellent alternative intervention for surgical aortic valve replacement. Cardiac sympathetic nervous (CSN) function and left atrial (LA) volume are both important prognostic factors in patients with aortic stenosis (AS) after TAVR. The relationship between the two clinical factors is unknown, however. This retrospective observational study aimed to assess the correlation between CSN function and LA volume in 48 symptomatic patients with severe AS (median age: 85 years, IQR 82-88 years; 81% female) before and after TAVR. CSN function was assessed by performing 123I-metaiodobenzylguanidine (MIBG) scintigraphy before and 6 months after TAVR, and the delayed heart-to-mediastinum ratio (dHMR) and washout rate (WR) were calculated. We also performed transthoracic echocardiography near the same time. TAVR improved the dHMR, WR, and LA volume index (LAVI) (dHMR: median 2.89 [IQR 2.62-3.23] vs. 2.98 [2.49-3.25], p = 0.0182; WR: 28% [24-38] vs. 23% [16-32], p < 0.0001; LAVI: 47.7 mL/m2 [37.8-56.3] vs. 41.2 mL/m2 [33.7-56.1], p = 0.0024). In multiple linear regression analysis, the percentage change in LAVI from baseline to post-TAVR (∆LAVI%) was an independent predictor of change in dHMR from baseline to post-TAVR (ß = - 0.35, p = 0.0110). In conclusion, LA volume reduction reflected CSN functional improvement after TAVR. In patients with TAVR, ∆LAVI% might be a valuable parameter for evaluating CSN functional recovery.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Heart Atria , Retrospective Studies , Severity of Illness Index
13.
Cardiovasc Revasc Med ; 49: 15-21, 2023 04.
Article in English | MEDLINE | ID: mdl-36599747

ABSTRACT

BACKGROUND: Excimer laser coronary angioplasty (ELCA) has been reported to be a safe and effective atherectomy device in percutaneous coronary intervention (PCI). However, thrombotic complications after ELCA have been occasionally observed. In this study, we evaluated the impact of attenuated plaque on thrombus formation and transient no-reflow after ELCA. METHODS: This study enrolled 58 lesions in 56 patients who underwent PCI with ELCA. It was a retrospective observational study at a single center. All lesions were imaged by intravascular ultrasound (IVUS) before and immediately after ELCA. On the plaque with ultrasound attenuation, attenuation angle per millimeter and attenuation length were measured. ELCA-induced thrombus was detected by IVUS, and transient no-reflow after ELCA was recorded. RESULTS: Thrombus was detected in 14 lesions (30 %), and transient no-reflow occurred in 3 lesions (5 %). Lesions with thrombus had a higher mean attenuation angle (median [interquartile range] 142° [112°-152°] vs. 64° [0°-115°]; p = 0.001), maximum attenuation angle (209° [174°-262°] vs. 86° [0°-173°]; p < 0.001), and longer attenuation length (12 mm [8 mm-17 mm] vs. 2 mm [0 mm-5 mm]; p < 0.001). Lesions with thrombus leading to transient no-reflow had a longer lipid length and a significantly higher troponin I level after PCI. CONCLUSIONS: IVUS-identified attenuated plaque was strongly correlated with ELCA-induced thrombus. Furthermore, attenuation length may predict transient no-reflow.


Subject(s)
Atherectomy, Coronary , Coronary Artery Disease , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Thrombosis , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Percutaneous Coronary Intervention/adverse effects , Lasers, Excimer/adverse effects , Coronary Angiography , Treatment Outcome , Ultrasonography, Interventional
14.
Int Heart J ; 63(2): 299-305, 2022.
Article in English | MEDLINE | ID: mdl-35354750

ABSTRACT

P-wave terminal force in lead V1 (PTFV1) is a marker of increased left atrial (LA) overload. Whether PTFV1 is associated with left ventricular (LV) diastolic function remains undetermined. We tested the hypothesis that PTFV1 is associated with LV diastolic parameters derived from gated myocardial perfusion single-photon emission computed tomography (SPECT) in patients with no significant perfusion abnormalities.The study population included 158 patients with preserved ejection fraction and no significant perfusion abnormalities. The amplitude and duration of the P-wave negative phase in lead V1 were measured using an electrocardiogram, and PTFV1 was calculated. The peak filling rate (PFR) and one-third mean filling rate (1/3 MFR) were obtained as LV diastolic parameters using gated SPECT.PTFV1 showed a weak correlation with the LA volume index (r = 0.31; P < 0.001). Significant associations were observed between PTFV1 and PFR (r = -0.27; P < 0.001) and 1/3 MFR (r = -0.26; P = 0.001). A multivariate linear regression analysis showed that age (ß = -0.26; P < 0.001), LV end-diastolic volume index (ß = -0.27; P = 0.001), and PTFV1 (ß = -0.15; P = 0.036) were significant factors associated with PFR. Moreover, male gender (ß = -0.16; P = 0.041), LV mass index (ß = -0.17; P = 0.046), and PTFV1 (ß = -0.17; P = 0.022) were significant factors associated with the 1/3 MFR.PTFV1 is associated with LV diastolic function, as derived from gated SPECT in patients with no significant perfusion abnormalities.


Subject(s)
Tomography, Emission-Computed, Single-Photon , Ventricular Function, Left , Diastole , Humans , Male , Perfusion , Stroke Volume , Tomography, Emission-Computed, Single-Photon/methods
16.
Heart Lung Circ ; 31(5): 671-677, 2022 May.
Article in English | MEDLINE | ID: mdl-34794871

ABSTRACT

BACKGROUND: Numerous studies have shown that 123I-metaiodobenzylguanidine (MIBG) scintigraphy, an index of cardiac sympathetic nervous (CSN) activity, is useful for predicting prognosis in patients with heart failure. However, the factors influencing the CSN activity of patients with severe aortic stenosis (AS) remain unclear. METHODS: We enrolled 91 patients with severe AS who underwent 123I-MIBG scintigraphy, coronary computed tomography (CCT), and transthoracic echocardiography. When CCT angiography (CCTA) showed an obstructive epicardial artery, invasive coronary angiography was performed within 1 week of CCTA. RESULTS: There were 21 male and 70 female patients with a mean age of 84±5 years. Eighty-five (85) patients (93%) had hypertension and 13 patients (14%) had diabetes. Two (2) patients (2%) had previous myocardial infarction and eight (9%) had a previous coronary intervention. All patients had severe AS: aortic valve area was 0.63±0.18 cm2 and the mean pressure gradient was 56±19 mmHg. Regarding 123I-MIBG parameters, early heart-to-mediastinum (H/M) ratio was 3.1±0.5, delayed H/M ratio was 2.8±0.6, and the washout rate (WR) was 35%±13%. Multivariable linear regression analysis showed that coronary artery disease (ß=-0.30, p=0.002) was an independent predictor of delayed H/M ratio, and that aortic valve area (ß=-0.20, p=0.048) was an independent predictor of WR. CONCLUSIONS: Our findings suggest that coronary artery disease is an independent predictor of delayed H/M ratio, and aortic valve area is an independent predictor of WR in patients with severe AS.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Myocardial Perfusion Imaging , 3-Iodobenzylguanidine , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Female , Heart , Humans , Iodine Radioisotopes , Male , Sympathetic Nervous System/diagnostic imaging
17.
Int Heart J ; 62(4): 866-871, 2021 Jul 30.
Article in English | MEDLINE | ID: mdl-34234077

ABSTRACT

The monocyte to high-density lipoprotein cholesterol (HDL-C) ratio has been considered to be a prognostic marker. Whether this ratio is associated with left ventricular (LV) diastolic function remains undetermined. We tested the hypothesis that the monocyte to HDL-C ratio is associated with LV diastolic parameters derived from gated myocardial perfusion single-photon emission computed tomography (SPECT) in patients with no significant perfusion abnormality.The study population included 196 patients with no significant perfusion abnormalities and preserved ejection fraction. The peak filling rate (PFR) and one-third mean filling rate (1/3 MFR) were obtained as LV diastolic parameters using gated SPECT. Monocyte counts and plasma HDL-C levels were also examined.Significant associations were observed between the monocyte to HDL-C ratio and PFR (r = -0.20; P = 0.005) and 1/3 MFR (r = -0.19; P = 0.009). Multivariate linear regression analysis was performed to determine factors associated with LV diastolic parameters. Age (ß = -0.27; P < 0.001), LV end-diastolic volume (ß = -0.19; P = 0.034), and monocyte to HDL-C ratio (ß = -0.15; P = 0.027) were determined to be significantly associated with PFR. Moreover, age (ß = -0.13; P = 0.007), LV mass index (ß = -0.18; P = 0.037), and the monocyte to HDL-C ratio (ß = -0.13; P = 0.045) were significantly associated with 1/3 MFR.These results demonstrated that the monocyte to HDL-C ratio is associated with LV diastolic function, as derived from gated SPECT in patients with no significant perfusion abnormality.


Subject(s)
Cholesterol, HDL , Monocytes , Myocardial Perfusion Imaging , Tomography, Emission-Computed, Single-Photon , Ventricular Function, Left , Aged , Aged, 80 and over , Diastole , Female , Humans , Male
18.
Eur Heart J Cardiovasc Imaging ; 22(9): 964-973, 2021 08 14.
Article in English | MEDLINE | ID: mdl-34041531

ABSTRACT

AIMS: This study aimed to evaluate the prevalence and distribution of pulmonary venous systolic flow reversal (PVSFR) in patients with severe mitral regurgitation (MR), and to examine the relationship between PVSFR profile and cardiac parameters. METHODS AND RESULTS: A total of 125 patients with severe MR who had transoesophageal echocardiography (TOE) performed were reviewed. Of these, 121 (96.8%) patients showed all four pulmonary venous (PV) flows by TOE. They were categorized into three groups by the MR aetiology: degenerative MR (DMR) (n = 72), ventricular functional MR (V-FMR) (n = 20), and atrial functional MR (A-FMR) (n = 16). Eighteen (16.7%) patients had PVSFR in all four PVs. Twenty-nine (26.9%) had PVSFR in three PVs, 23 (21.3%) in two PVs, and 23 (21.3%) in one PV. PVSFR appeared at right PVs more frequently compared with left PVs. A high number of PVSFR was significantly correlated with higher pulmonary capillary wedge pressure (PCWP) and 3D vena contracta area (3D-VCA). With regard to MR aetiology, the number of PVSFRs was correlated with high 3D-VCA in patients with DMR and A-FMR, while it was correlated with high PCWP in patients with V-FMR. Laminar-type PVSFR appeared more frequently in FMR compared with DMR, and it had a relationship with higher PCWP and lower right ventricular fractional area change (RVFAC). CONCLUSION: All four PV were detected in 96.8%, and 16.8% patients had PVSFR in all four PVs. PCWP and 3D-VCA were correlated with the number of PVSFRs in severe MR patients. Laminar-type PVSFR was related to higher PCWP and lower RVFAC.


Subject(s)
Mitral Valve Insufficiency , Pulmonary Veins , Echocardiography, Transesophageal , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/epidemiology , Prevalence , Pulmonary Veins/diagnostic imaging , Pulmonary Wedge Pressure
19.
Echocardiography ; 38(6): 932-942, 2021 06.
Article in English | MEDLINE | ID: mdl-33983660

ABSTRACT

BACKGROUND: Left ventricular (LV) outflow tract (LVOT) obstruction increases mortality in patients undergoing transcatheter mitral valve implantation (TMVI) in degenerated bioprostheses, annuloplasty rings, and native mitral valves. We aimed to evaluate the LVOT area after TMVI using 3-dimensional (3D) transesophageal echocardiography (TEE) and to investigate the preprocedural cardiac geometry that affects the LVOT area after TMVI. METHODS: We retrospectively reviewed echocardiography data in 43 patients who had TMVI. A change in pressure gradient across LVOT from before to after TMVI (∆PG) and postprocedure 3D LVOT cross-sectional area at the level of the most distal portion of the mitral valve stent that was closest to the LV apex were assessed as evidence of LVOT narrowing. RESULTS: Transcatheter mitral valve implantation with the use of balloon-expandable valve system was performed for 24 bioprostheses, 7 annuloplasty rings, and 12 native valves. Compared to patients without increase in LVOT gradient (∆PG <10 mm Hg; n = 33), patients with increase in LVOT gradient (∆PG ≥10 mm Hg; n = 10) had smaller LV end-systolic volume (LVESV), greater LV ejection fraction (LVEF), and smaller aorto-mitral (AM) angle. The LVOT area at the valve stent distal edge showed strong association with ∆PG (r = -.68, P < .0001). Only a small AM angle was associated with a small LVOT area at the valve stent distal edge on multivariable analysis, independent of LVESV and LVEF. CONCLUSION: Small LV size, preserved LVEF, and small AM angle were associated with LVOT narrowing. 3D-derived AM angle might be independently associated with LVOT narrowing in patients undergoing transcatheter mitral valve-in-valve, valve-in-ring, and valve-in-native valve implantation, independent of LVESV and LVEF.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Transcatheter Aortic Valve Replacement , Ventricular Outflow Obstruction , Cardiac Catheterization , Echocardiography, Transesophageal , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Retrospective Studies , Treatment Outcome
20.
Ann Nucl Med ; 35(6): 662-668, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33866517

ABSTRACT

BACKGROUND: The frontal QRS-T angle is one of markers of ventricular repolarization. We investigated whether or not the frontal QRS-T angle could predict left ventricular (LV) volume and function derived from ECG-gated SPECT in patients with advanced chronic kidney disease (CKD). METHODS: Two hundred and twelve patients with advanced CKD defined as estimated glomerular filtration rate of < 45 ml min-1/1.73 m2 were enrolled. Wide QRS-T angle was defined as its angle of > 90°, and was considered abnormal. Enlarged LV end-diastolic volume (LVEDV) was defined as LVEDV index of > 76 ml m-2 in men and > 57 ml m-2 in women. Reduced LV ejection fraction (LVEF) was defined as LVEF of < 40%. RESULTS: Fifty-one patients (24%) had wide QRS-T angle, and 161 patients (76%) had normal QRS-T angle. Patients with wide QRS-T angle had larger SSS [9 (5-16) vs 4 (1-9), p < 0.001], larger LVEDV index (69 ± 29 vs 50 ± 18 ml m-2, p < 0.001) and lower LVEF (47 ± 13 vs 59 ± 12%, p < 0.001) than those with normal QRS-T angle. Multivariate analysis showed that wide QRS-T angle (odds ratio 5.93; 95% CI 2.55-14.33; p < 0.001) was significantly associated with enlarged LVEDV, whereas SSS severity was not. Severely abnormal SSS (odds ratio 3.80; 95% CI 1.16-14.05; p < 0.03) and wide QRS-T angle (odds ratio 5.67; 95% CI 2.10-16.22; p < 0.001) were significantly associated with reduced LVEF. CONCLUSIONS: Our results suggest that wide QRS-T angle is associated with LV remodeling such as enlarged LVEDV or reduced LVEF in patients with advanced CKD.


Subject(s)
Stroke Volume , Tomography, Emission-Computed, Single-Photon , Aged , Female , Heart Ventricles , Humans , Male , Middle Aged , Ventricular Dysfunction, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...