Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Heart Assoc ; 13(1): e030776, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38156546

ABSTRACT

BACKGROUND: Epinephrine is administered to increase coronary perfusion pressure during advanced life support and promote short-term survival. Recent cardiopulmonary resuscitation (CPR) guidelines recommend an epinephrine dosing interval of 3 to 5 minutes during resuscitation; however, scientific evidence supporting this recommendation is lacking. Therefore, we aimed to investigate the hemodynamic effects of repeated epinephrine doses during CPR by monitoring augmented blood pressure after its administration in a swine model of cardiac arrest. METHODS AND RESULTS: A secondary analysis of data from a published study was performed using a swine cardiac arrest model. The epinephrine dose was fixed at 1 mg, and the first dose of epinephrine was administered after no-flow and low-flow times of 2 minutes and 8 minutes, respectively, and subsequently administered every 4 minutes. Four cycles of dosing intervals were defined because a previous study was terminated 26 minutes after the induction of ventricular fibrillation. Augmented blood pressures and corresponding timelines were determined. Augmented blood pressure trends following cycles and the epinephrine effect duration were also monitored. Among the 140 CPR cycles, the augmented blood pressure after epinephrine administration was the highest during the first cycle of CPR and decreased gradually with further cycle repetitions. The epinephrine effect duration did not differ between repeated cycles. The maximum blood pressure was achieved 78 to 97 seconds after epinephrine administration. CONCLUSIONS: Hemodynamic augmentation with repeated epinephrine administration during CPR decreased with cycle progression. Further studies are required to develop an epinephrine administration strategy to maintain its hemodynamic effects during prolonged resuscitation.


Subject(s)
Cardiopulmonary Resuscitation , Heart Arrest , Animals , Swine , Cardiopulmonary Resuscitation/methods , Epinephrine , Heart Arrest/etiology , Hemodynamics , Ventricular Fibrillation
2.
PLoS One ; 18(7): e0288688, 2023.
Article in English | MEDLINE | ID: mdl-37494389

ABSTRACT

BACKGROUND: Automatic chest compression devices (ACCDs) can promote high-quality cardiopulmonary resuscitation (CPR) and are widely used worldwide. Early application of automated external defibrillators (AEDs) along with high-quality CPR is crucial for favorable outcomes in patients with cardiac arrest. Here, we developed an automated CPR (A-CPR) apparatus that combines ACCD and AED and evaluated its performance in a pilot animal-based study. METHODS: Eleven pigs (n = 5, A-CPR group; n = 6, ACCD CPR and AED [conventional CPR (C-CPR)] group) were enrolled in this study. After 2 min observation without any treatment following ventricular fibrillation induction, CPR with a 30:2 compression/ventilation ratio was performed for 6 min, mimicking basic life support (BLS). A-CPR or C-CPR was applied immediately after BLS, and resuscitation including chest compression and defibrillation, was performed following a voice prompt from the A-CPR device or AED. Hemodynamic parameters, including aortic pressure, right atrial pressure, coronary perfusion pressure, carotid blood flow, and end-tidal carbon dioxide, were monitored during resuscitation. Time variables, including time to start rhythm analysis, time to charge, time to defibrillate, and time to subsequent chest compression, were also measured. RESULTS: There were no differences in baseline characteristics, except for arterial carbon dioxide pressure (39 in A-CPR vs. 33 in C-CPR, p = 0.034), between the two groups. There were no differences in hemodynamic parameters between the groups. However, time to charge (28.9 ± 5.6 s, A-CPR group; 47.2 ± 12.4 s, C-CPR group), time to defibrillate (29.1 ± 7.2 s, A-CPR group; 50.5 ± 12.3 s, C-CPR group), and time to subsequent chest compression (32.4 ± 6.3 s, A-CPR group; 56.3 ± 10.7 s, C-CPR group) were shorter in the A-CPR group than in the C-CPR group (p = 0.015, 0.034 and 0.02 respectively). CONCLUSIONS: A-CPR can provide effective chest compressions and defibrillation, thereby shortening the time required for defibrillation.


Subject(s)
Cardiopulmonary Resuscitation , Heart Arrest , Animals , Swine , Pilot Projects , Carbon Dioxide , Heart Arrest/therapy , Animals, Laboratory
SELECTION OF CITATIONS
SEARCH DETAIL