1.
Radiol Phys Technol ; 17(2): 458-466, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38700638

ABSTRACT

The purpose of the study is to investigate the variation in Hounsfield unit (HU) values calculated using dual-energy computed tomography (DECT) scanners. A tissue characterization phantom inserting 16 reference materials were scanned three times using DECT scanners [dual-layer CT (DLCT), dual-source CT (DSCT), and fast kilovoltage switching CT (FKSCT)] changing scanning conditions. The single-energy CT images (120 or 140 kVp), and virtual monochromatic images at 70 keV (VMI70) and 140 keV (VMI140) were reconstructed, and the HU values of each reference material were measured. The difference in HU values was larger when the phantom was scanned using the half dose with wrapping with rubber (strong beam-hardening effect) compared with the full dose without the rubber (reference condition), and the difference was larger as the electron density increased. For SECT, the difference in HU values against the reference condition measured by the DSCT (3.2 ± 5.0 HU) was significantly smaller (p < 0.05) than that using DLCT with 120 kVp (22.4 ± 23.8 HU), DLCT with 140 kVp (11.4 ± 12.8 HU), and FKSCT (13.4 ± 14.3 HU). The respective difference in HU values in the VMI70 and VMI140 measured using the DSCT (10.8 ± 17.1 and 3.5 ± 4.1 HU) and FKSCT (11.5 ± 21.8 and 5.5 ± 10.4 HU) were significantly smaller than those measured using the DLCT120 (23.1 ± 27.5 and 12.4 ± 9.4 HU) and DLCT140 (22.3 ± 28.6 and 13.1 ± 11.4 HU). The HU values and the susceptibility to beam-hardening effects varied widely depending on the DECT scanners.


Subject(s)
Phantoms, Imaging , Tomography, X-Ray Computed , Tomography, X-Ray Computed/methods , Image Processing, Computer-Assisted/methods , Radiation Dosage
2.
Radiol Phys Technol ; 17(2): 389-395, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38466497

ABSTRACT

To investigate the geometric accuracy of the radiation focal point (RFP) and cone-beam computed tomography (CBCT) over long-term periods for the ICON Leksell Gamma Knife radiosurgery system. This phantom study utilized the ICON quality assurance tool plus, and the phantom was manually set on the patient position system before the implementation of treatment for patients. The deviation of the RFP position from the unit center point (UCP) and the positions of the four ball bearings (BBs) in the CBCT from the reference position were automatically analyzed. During 544 days, a total of 269 analyses were performed on different days. The mean ± standard deviation (SD) of the deviation between measured RFP and UCP was 0.01 ± 0.03, 0.01 ± 0.03, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively. The deviations with offset values after the cobalt-60 source replacement (0.00 ± 0.03, -0.01 ± 0.01, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively) were significantly (p = 0.001) smaller than those before the replacement (0.02 ± 0.03, 0.02 ± 0.01, and -0.02 ± 0.01 mm in the X, Y, and Z directions, respectively). The overall mean ± SD of four BBs was -0.03 ± 0.03, -0.01 ± 0.05, and 0.01 ± 0.03 mm in the X, Y, and Z directions, respectively. Geometric positional accuracy was ensured to be within 0.1 mm on most days over a long-term period of more than 500 days.


Subject(s)
Cone-Beam Computed Tomography , Phantoms, Imaging , Radiosurgery , Radiosurgery/instrumentation , Quality Assurance, Health Care , Humans , Quality Control , Time Factors
3.
J Appl Clin Med Phys ; : e14294, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38319652

ABSTRACT

PURPOSE: To explore the potential of quantitative parameters of the hydrogel spacer distribution as predictors for separating the rectum from the planning target volume (PTV) in linear-accelerator-based stereotactic body radiotherapy (SBRT) for prostate cancer. METHODS: Fifty-five patients underwent insertion of a hydrogel spacer and were divided into groups 1 and 2 of the PTV separated from and overlapping with the rectum, respectively. Prescribed doses of 36.25-45 Gy in five fractions were delivered to the PTV. The spacer cover ratio (SCR) and hydrogel-implant quality score (HIQS) were calculated. RESULTS: Dosimetric and quantitative parameters of the hydrogel spacer distribution were compared between the two groups. For PTV, D99% in group 1 (n = 29) was significantly higher than that in group 2 (n = 26), and Dmax , D0.03cc , D1cc , and D10% for the rectum were significantly lower in group 1 than in group 2. The SCR for prostate (89.5 ± 12.2%) in group 1 was significantly higher (p < 0.05) than that in group 2 (74.7 ± 10.3%). In contrast, the HIQS values did not show a significant difference between the groups. An area under the curve of 0.822 (95% confidence interval, 0.708-0.936) for the SCR was obtained with a cutoff of 93.6%, sensitivity of 62.1%, and specificity of 100%. CONCLUSIONS: The SCR seems promising to predict the separation of the rectum from the PTV in linear-accelerator-based SBRT for prostate cancer.

4.
Phys Med ; 117: 103182, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38086310

ABSTRACT

PURPOSE: To investigate the prognostic power of cone-beam computed-tomography (CBCT)-based delta-radiomics in esophageal squamous cell cancer (ESCC) patients treated with concurrent chemoradiotherapy (CCRT). METHODS: We collected data from 26 ESCC patients treated with CCRT. CBCT images acquired at five time points (1st-5th week) per patient during CCRT were used in this study. Radiomic features were extracted from the five CBCT images on the gross tumor volumes. Then, 17 delta-radiomic feature sets derived from five types of calculations were obtained for all the cases. Leave-one-out cross-validation was applied to investigate the prognostic power of CBCT-based delta-radiomic features. Feature selection and construction of a prediction model using Coxnet were performed using training samples. Then, the test sample was classified into high or low risk in each cross-validation fold. Survival analysis for the two groups were performed to evaluate the prognostic power of the extracted CBCT-based delta-radiomic features. RESULTS: Four delta-radiomic feature sets indicated significant differences between the high- and low-risk groups (p < 0.05). The highest C-index in the 17 delta-radiomic feature sets was 0.821 (95 % confidence interval, 0.735-0.907). That feature set had p-value of the log-rank test and hazard ratio of 0.003 and 4.940 (95 % confidence interval, 1.391-17.544), respectively. CONCLUSIONS: We investigated the potential of using CBCT-based delta-radiomics for prognosis of ESCC patients treated with CCRT. It was demonstrated that delta-radiomic feature sets based on the absolute value of relative difference obtained from the early to the middle treatment stages have high prognostic power for ESCC.


Subject(s)
Carcinoma, Squamous Cell , Esophageal Neoplasms , Humans , Carcinoma, Squamous Cell/diagnostic imaging , Carcinoma, Squamous Cell/therapy , Prognosis , Radiomics , Retrospective Studies , Esophageal Neoplasms/diagnostic imaging , Esophageal Neoplasms/therapy , Cone-Beam Computed Tomography/methods , Chemoradiotherapy , Epithelial Cells/pathology
5.
Phys Med ; 113: 102648, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37672845

ABSTRACT

PURPOSE: The purpose of this study is to develop a virtual CBCT simulator with a head and neck (HN) human phantom library and to demonstrate the feasibility of elemental material decomposition (EMD) for quantitative CBCT imaging using this virtual simulator. METHODS: The library of 36 HN human phantoms were developed by extending the ICRP 110 adult phantoms based on human age, height, and weight statistics. To create the CBCT database for the library, a virtual CBCT simulator that simulated the direct and scattered X-ray on a flat panel detector using ray-tracing and deep-learning (DL) models was used. Gaussian distributed noise was also included on the flat panel detector, which was evaluated using a real CBCT system. The usefulness of the virtual CBCT system was demonstrated through the application of the developed DL-based EMD model for case involving virtual phantom and real patient. RESULTS: The virtual simulator could generate various virtual CBCT images based on the human phantom library, and the prediction of the EMD could be successfully performed by preparing the CBCT database from the proposed virtual system, even for a real patient. The CBCT image degradation owing to the scattered X-ray and the statistical noise affected the prediction accuracy, although these effects were minimal. Furthermore, the elemental distribution using the real CBCT image was also predictable. CONCLUSIONS: This study demonstrated the potential of using computer vision for medical data preparation and analysis, which could have important implications for improving patient outcomes, especially in adaptive radiation therapy.


Subject(s)
Cone-Beam Computed Tomography , Head , Adult , Humans , Phantoms, Imaging , Databases, Factual , Neck
6.
Cureus ; 15(1): e34347, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36865951

ABSTRACT

Radiation therapy plays an important role in cancer treatment along with surgery and systemic therapy. The total dose of radiation therapy is divided into small doses, and the treatment is typically delivered once a day. The total treatment period can need several weeks or more, and it is necessary to deliver the radiation dose to the target volume within the patient precisely each time. Therefore, the reproducibility of patient positioning is essential for the precision of the dose delivery. Although radiological technologies such as image-guided radiation therapy have also recently been widely used for positioning patients, skin marking is still widely used in many facilities. Skin marking is an inexpensive and universal positioning technique in patients undergoing radiation therapy; however, it is considered a major source of psychological stress. We propose the use of fluorescent ink pens, which are invisible in standard room lighting, as skin markers for radiotherapy. The primary technique of fluorescence emission is widely employed in molecular biological experiments and for assessing cleaning protocols for infection control. This technique may reduce the stress induced by skin markings during radiotherapy.

7.
Med Phys ; 49(6): 3769-3782, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35315529

ABSTRACT

PURPOSE: In recent years, deep learning-based image processing has emerged as a valuable tool for medical imaging owing to its high performance. However, the quality of deep learning-based methods heavily relies on the amount of training data; the high cost of acquiring a large data set is a limitation to their utilization in medical fields. Herein, based on deep learning, we developed a computed tomography (CT) modality conversion method requiring only a few unsupervised images. METHODS: The proposed method is based on cycle-consistency generative adversarial network (CycleGAN) with several extensions tailored for CT images, which aims at preserving the structure in the processed images and reducing the amount of training data. This method was applied to realize the conversion of megavoltage computed tomography (MVCT) to kilovoltage computed tomography (kVCT) images. Training was conducted using several data sets acquired from patients with head and neck cancer. The size of the data sets ranged from 16 slices (two patients) to 2745 slices (137 patients) for MVCT and 2824 slices (98 patients) for kVCT. RESULTS: The required size of the training data was found to be as small as a few hundred slices. By statistical and visual evaluations, the quality improvement and structure preservation of the MVCT images converted by the proposed model were investigated. As a clinical benefit, it was observed by medical doctors that the converted images enhanced the precision of contouring. CONCLUSIONS: We developed an MVCT to kVCT conversion model based on deep learning, which can be trained using only a few hundred unpaired images. The stability of the model against changes in data size was demonstrated. This study promotes the reliable use of deep learning in clinical medicine by partially answering commonly asked questions, such as "Is our data sufficient?" and "How much data should we acquire?"


Subject(s)
Head and Neck Neoplasms , Radiotherapy Planning, Computer-Assisted , Cone-Beam Computed Tomography , Humans , Image Processing, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed/methods
8.
Radiat Oncol ; 17(1): 41, 2022 Feb 23.
Article in English | MEDLINE | ID: mdl-35197092

ABSTRACT

BACKGROUND: The aim of this study was to clarify the association between intrafractional prostate shift and hydrogel spacer. METHODS: Thirty-eight patients who received definitive volumetric modulated arc therapy (VMAT)-stereotactic body radiation therapy (SBRT) for prostate cancer with prostate motion monitoring in our institution in 2018-2019 were retrospectively evaluated. In order to move the rectum away from the prostate, hydrogel spacer (SpaceOAR system, Boston Scientific, Marlborough, the United States) injection was proposed to the patients as an option in case of meeting the indication of use. We monitored intrafractional prostate motion by using a 4-dimensional (4D) transperineal ultrasound device: the Clarity 4D ultrasound system (Elekta AB). The deviation of the prostate was monitored in each direction: superior-inferior, left-right, and anterior-posterior. We also calculated the vector length. The maximum intrafractional displacement (MID) per fraction for each direction was detected and mean of MIDs was calculated per patient. The MIDs in the non-spacer group and the spacer group were compared using the unpaired t-test. RESULTS: We reviewed 33 fractions in eight patients as the spacer group and 148 fractions in 30 patients as the non-spacer group. The superior MID was 0.47 ± 0.07 (mean ± SE) mm versus 0.97 ± 0.24 mm (P = 0.014), the inferior MID was 1.07 ± 0.11 mm versus 1.03 ± 0.25 mm (P = 0.88), the left MID was 0.74 ± 0.08 mm versus 0.87 ± 0.27 mm (P = 0.55), the right MID was 0.67 ± 0.08 mm versus 0.92 ± 0.21 mm (P = 0.17), the anterior MID was 0.45 ± 0.06 mm versus 1.16 ± 0.35 mm (P = 0.0023), and the posterior MID was 1.57 ± 0.17 mm versus 1.37 ± 0.22 mm (P = 0.56) in the non-spacer group and the spacer group, respectively. The max of VL was 2.24 ± 0.19 mm versus 2.89 ± 0.62 mm (P = 0.19), respectively. CONCLUSIONS: Our findings suggest that maximum intrafractional prostate motion during VMAT-SBRT was larger in patients with hydrogel spacer injection in the superior and anterior directions. Since this difference seemed not to disturb the dosimetric advantage of the hydrogel spacer, we do not recommend routine avoidance of the hydrogel spacer use.


Subject(s)
Hydrogels/administration & dosage , Prostatic Neoplasms/radiotherapy , Radiosurgery/methods , Radiotherapy, Intensity-Modulated/methods , Aged , Aged, 80 and over , Humans , Injections , Male , Middle Aged , Motion , Retrospective Studies
11.
J Appl Clin Med Phys ; 21(12): 334-339, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33184970

ABSTRACT

Using a plane-parallel advanced Markus ionization chamber and a stack of water-equivalent solid phantom blocks, percentage surface and build-up doses of Elekta 6 MV flattening filter (FF) and flattening-filter-free (FFF) beams were measured as a function of the phantom depth for field sizes ranging from 2 × 2 to 10 × 10 cm2 . It was found that the dose difference between the FF and the FFF beams was relatively small. The maximum dose difference between the FF and the FFF beams was 4.4% at a depth of 1 mm for a field size of 2 × 2 cm2 . The dose difference was gradually decreased while the field size was increased up to 10 × 10 cm2 . The measured data were also compared to published Varian FF and FFF data, suggesting that the percentage surface and build-up doses as well as the percentage dose difference between FF and FFF beams by our Elekta linac were smaller than those by the Varian linac.


Subject(s)
Photons , Water , Humans , Particle Accelerators , Phantoms, Imaging , Radiotherapy Dosage
12.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 76(11): 1173-1184, 2020.
Article in Japanese | MEDLINE | ID: mdl-33229847

ABSTRACT

PURPOSE: Volumetric modulated arc therapy (VMAT) can acquire projection images during rotational irradiation, and cone-beam computed tomography (CBCT) images during VMAT delivery can be reconstructed. The poor quality of CBCT images prevents accurate recognition of organ position during the treatment. The purpose of this study was to improve the image quality of CBCT during the treatment by cycle generative adversarial network (CycleGAN). METHOD: Twenty patients with clinically localized prostate cancer were treated with VMAT, and projection images for intra-treatment CBCT (iCBCT) were acquired. Synthesis of PCT (SynPCT) with improved image quality by CycleGAN requires only unpaired and unaligned iCBCT and planning CT (PCT) images for training. We performed visual and quantitative evaluation to compare iCBCT, SynPCT and PCT deformable image registration (DIR) to confirm the clinical usefulness. RESULT: We demonstrated suitable CycleGAN networks and hyperparameters for SynPCT. The image quality of SynPCT improved visually and quantitatively while preserving anatomical structures of the original iCBCT. The undesirable deformation of PCT was reduced when SynPCT was used as its reference instead of iCBCT. CONCLUSION: We have performed image synthesis with preservation of organ position by CycleGAN for iCBCT and confirmed the clinical usefulness.


Subject(s)
Radiotherapy, Intensity-Modulated , Spiral Cone-Beam Computed Tomography , Algorithms , Cone-Beam Computed Tomography , Humans , Image Processing, Computer-Assisted , Male , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
13.
Radiol Phys Technol ; 13(3): 238-248, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32656744

ABSTRACT

This study aimed to reconstruct the dose distribution of single fraction of stereotactic body radiotherapy for patients with prostate cancer using cone-beam computed tomography (CBCT) and a log file during volumetric-modulated arc therapy (VMAT) delivery with flattening-filter-free (FFF) mode. Twenty patients with clinically localized prostate cancer were treated with FFF-VMAT, and projection images for in-treatment CBCT (iCBCT) imaging were concomitantly acquired with a log file. A D95 dose of 36.25 Gy in five fractions was prescribed to each planning target volume (PTV) on each treatment planning CT (pCT). Deformed pCT (dCT) was obtained from the iCBCT using a hybrid deformable image registration algorithm. Dose distributions on the dCT were calculated using Pinnacle3 v9.10 by converting the log file data to Pinnacle3 data format using an in-house software. Dose warping was performed by referring to deformation vector fields calculated from pCT and dCT. Reconstructed dose distribution was compared with that of the original plan. Dose differences between the original and reconstructed dose distributions were within 3% at the isocenter and observed in PTV and organ-at-risk (OAR) regions. Differences in OAR regions were relatively larger than those in the PTV, presumably because OARs were more deformed than the PTV. Therefore, our method can be used successfully to reconstruct the dose distributions of one fraction using iCBCT and a log file during FFF-VMAT delivery.


Subject(s)
Cone-Beam Computed Tomography , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiation Dosage , Radiosurgery , Radiotherapy, Intensity-Modulated , Aged , Humans , Male , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Retrospective Studies
14.
Oncol Lett ; 19(4): 2695-2704, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32218820

ABSTRACT

A standard treatment for patients with early-stage non-small cell lung cancer (NSCLC) who undergo surgery, and subsequently develop local failure or intrathoracic oligo-recurrence, has not yet been established. The present study aimed to assess the feasibility of stereotactic body radiotherapy (SBRT) for this subgroup of patients. Consequently, a retrospective analysis was conducted of patients with NSCLC recurrence who were treated with SBRT, and previously underwent curative surgical resection between October 2011 and October 2016. Post-SBRT survival [overall survival (OS); progression-free survival (PFS); and local control (LC)] and toxicity were analyzed. Prognostic factors for OS were identified using univariate and multivariate analysis. A total of 52 patients and 59 tumors were analyzed. The median follow-up time was 25 months (35 months for surviving patients), and median OS following salvage SBRT was 32 months. The 1- and 3-year OS rates were 84.4 and 67.8%, respectively. 1- and 3-year PFS rates were 80.8 and 58.7%, respectively. Only 4 patients (7.7%) developed local failure. Median LC was 71 months and 1- and 3-year LC rate were 97.9 and 94.9%, respectively. A total of 4 patients experienced grade 3 or higher adverse events (AEs) and two experienced grade 5 AEs (pneumonitis and hemoptysis). Central tumor location and the possibility of re-operation were independent prognostic factors for OS. The present study indicated that post-operative salvage SBRT is a promising therapeutic option for patients with NSCLC with locoregional or intrathoracic oligo-recurrence. We regard toxicity was also acceptable. However, further research is required on the appropriate selection of subjects, and stratification of the analysis by certain risk factors would increase the accuracy of the conclusions.

16.
Med Phys ; 47(3): 998-1010, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31840269

ABSTRACT

PURPOSE: Cone-beam computed tomography (CBCT) offers advantages over conventional fan-beam CT in that it requires a shorter time and less exposure to obtain images. However, CBCT images suffer from low soft-tissue contrast, noise, and artifacts compared to conventional fan-beam CT images. Therefore, it is essential to improve the image quality of CBCT. METHODS: In this paper, we propose a synthetic approach to translate CBCT images with deep neural networks. Our method requires only unpaired and unaligned CBCT images and planning fan-beam CT (PlanCT) images for training. The CBCT images and PlanCT images may be obtained from other patients as long as they are acquired with the same scanner settings. Once trained, three-dimensionally reconstructed CBCT images can be directly translated into high-quality PlanCT-like images. RESULTS: We demonstrate the effectiveness of our method with images obtained from 20 prostate patients, and provide a statistical and visual comparison. The image quality of the translated images shows substantial improvement in voxel values, spatial uniformity, and artifact suppression compared to those of the original CBCT. The anatomical structures of the original CBCT images were also well preserved in the translated images. CONCLUSIONS: Our method produces visually PlanCT-like images from CBCT images while preserving anatomical structures.


Subject(s)
Cone-Beam Computed Tomography , Deep Learning , Image Processing, Computer-Assisted/methods , Humans
17.
Clin Transl Radiat Oncol ; 20: 9-12, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31709307

ABSTRACT

Optimizing irradiation protocols for pregnant women is challenging, because there are few cases and a dearth of fetal dosimetry data. We cared for a 36-year-old pregnant woman with tongue cancer. Prior to treatment, we compared three intensity-modulated radiation therapy (IMRT) techniques, including helical tomotherapy, volumetric arc therapy (VMAT), and flattening-filter free VMAT (FFF-VMAT) using treatment planning software. FFF-VMAT achieved the minimum fetal exposure and was selected as the optimal modality. We prescribed 66 Gy to the involved nodes, 60 Gy to the tumor bed and ipsilateral neck, and 54 Gy to the contralateral neck over 33 fractions. To confirm the out-of-field exposure per fraction, surface doses and the rectal dose were measured during FFF-VMAT delivery. Postoperative chemoradiotherapy was delivered using IMRT and a cisplatin regimen. Without any shielding, the total fetal dose was 0.03 Gy, within the limits established by the ICRP. A healthy girl was born vaginally at 37 weeks' gestation.

18.
Eur Radiol ; 29(2): 985-992, 2019 Feb.
Article in English | MEDLINE | ID: mdl-29987416

ABSTRACT

OBJECTIVES: To (a) evaluate the interpolation frames of frame rate conversion (FRC) compared with fluoroscopic frames of conventional method, and (b) compare radiation dose and fluoroscopy time between various clinical examinations without and with FRC retrospectively. METHODS: This study consisted of a basic study and a clinical retrospective analysis. The radiation dosimetry, visual assessment and measurements of contrast to noise ratio were examined. Similarity between interpolation frames and fluoroscopic frames was evaluated using normalised cross-correlation values. In the clinical retrospective analysis approved by the institutional review board, we extracted 270 examinations performed without FRC (conventional group, 12.5 pulses/s) and with FRC (FRC group, 6.25 pulses/s) from 23 May to 31 December 2016. The fluoroscopy parameters and demographics of the two groups of the clinical examinations were compared. Statistical analyses were performed with Wilcoxon signed-rank test, Brunner-Munzel test and χ2 test. RESULTS: In the basic study, the only significant difference was that the radiation dose of FRC was approximately half that of the conventional method in the same fluoroscopy time (p = .031). The interpolation frames of FRC were similar to the fluoroscopic frames of the conventional method. In the clinical retrospective analysis, the only significant difference was that FRC reduced the fluoroscopy dose by 48% and the total dose by 31% compared with the conventional method (p < .001). There was no significant difference in the others. CONCLUSION: FRC significantly reduced the radiation dose without extending the fluoroscopy time and maintaining the image quality compared to the conventional method. KEY POINTS: • Although X-ray fluoroscopic techniques are widely used for various clinical purposes, X-ray fluoroscopic examinations have radiation risks. • Frame rate conversion is an image processing technique for radiation dose reduction. • Clinical retrospective analysis showed that FRC reduces radiation doses of patients.


Subject(s)
Fluoroscopy/instrumentation , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Radiation Injuries/prevention & control , Adolescent , Adult , Aged , Aged, 80 and over , Child , Equipment Design , Female , Humans , Male , Middle Aged , Radiation Dosage , Retrospective Studies , Young Adult
19.
Oncol Lett ; 16(4): 4498-4506, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30214585

ABSTRACT

Stereotactic body radiotherapy (SBRT) for centrally-located lung tumors remains a challenge because of the increased risk of treatment-related adverse events (AEs), and uncertainty around prescribing the optimal dose. The present study reported the results of central tumor SBRT with 56 Gy in 7 fractions (fr) at the University of Tokyo Hospital. A total of 35 cases that underwent SBRT with or without volumetric-modulated arc therapy consisting of 56 Gy/7 fr for central lung lesions between 2010 and 2016 at the University of Tokyo Hospital were reveiwed. A central lesion was defined as a tumor within 2 cm of the proximal bronchial tree (RTOG 0236 definition) or within 2 cm in all directions of any critical mediastinal structure. Local control (LC), overall survival (OS), and AEs were investigated. The Kaplan-Meier method was used to estimate LC and OS. AEs were scored per the Common Terminology Criteria for Adverse Events Version 4.0. Thirty-five patients with 36 central lung lesions were included. Fifteen lesions were primary non-small cell lung cancer (NSCLC), 13 were recurrences of NSCLC, and 8 had oligo-recurrences from other primaries. Median tumor diameter was 29 mm. Eighteen patients had had prior surgery. At a median follow-up of 13.1 months for all patients and 18.3 months in surviving patients, 22 patients had died, ten due to primary disease (4 NSCLC), while three were treatment-related. The 1- and 2-year OS were 57.3 and 40.4%, respectively, and median OS was 15.7 months. Local recurrence occurred in only two lesions. 1- and 2-year LC rates were both 96%. Nine patients experienced grade ≥3 toxicity, representing 26% of the cohort. Two of these were grade 5, one pneumonitis and one hemoptysis. Considering the background of the subject, tumor control of our central SBRT is promising, especially in primary NSCLC. However, the safety of SBRT to central lung cancer remains controversial.

20.
Oncol Lett ; 15(3): 3928-3936, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29563993

ABSTRACT

The present study sought to evaluate the impact of the flattening filter-free (FFF) technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy. Its clinical safety and availability were compared with the flattening filter (FF) method. The cases of 65 patients who underwent lung volumetric modulated arc therapy-stereotactic body radiotherapy (VMAT-SBRT) using FF or FFF techniques were reviewed. A total of 55 Gy/4 fractions (fr) was prescribed for peripheral lesions or 56 Gy/7 fr for central lesions. The total monitor units (MU), treatment time, dose to tumors, dose to organs at risk, tumor control (local control rate, overall survival, progression-free survival) and adverse events between cases treated with FF and cases treated with the FFF technique were compared. A total of 35 patients were treated with conventional FF techniques prior to November 2014 and 30 patients were treated with FFF techniques after this date. It was revealed that the beam-on time was significantly shortened by the FFF technique (P<0.01). Other factors were similar for FFF and FF plans in respect to conformity (P=0.95), homogeneity (P=0.20) and other dosimetric values, including total MU and planning target volume/internal target volume coverage. The median follow-up period was 18 months (range, 2-35). One-year local control rates were 97.1 and 90.0% in the FF group and FFF groups, respectively (P=0.33). Grade 3 pneumonitis was observed in 5.8% of FF patients and 3.4% of FFF patients (P=1.00). No other adverse events ≥grade 3 were observed. The results of the study suggest that VMAT-SBRT using the FFF technique shortens the treatment time for lung SBRT while maintaining a high local control rate with low toxicity.