1.
Water Res ; 164: 114869, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31377523

ABSTRACT

Past waterborne outbreaks have demonstrated that informed vulnerability assessment of drinking water supplies is paramount for the provision of safe drinking water. Although current monitoring frameworks are not designed to account for short-term peak concentrations of fecal microorganisms in source waters, the recent development of online microbial monitoring technologies is expected to fill this knowledge gap. In this study, online near real-time monitoring of ß-d-glucuronidase (GLUC) activity was conducted for 1.5 years at an urban drinking water intake impacted by multiple point sources of fecal pollution. Parallel routine and event-based monitoring of E. coli and online measurement of physico-chemistry were performed at the intake and their dynamics compared over time. GLUC activity fluctuations ranged from seasonal to hourly time scales. All peak contamination episodes occurred between late fall and early spring following intense rainfall and/or snowmelt. In the absence of rainfall, recurrent daily fluctuations in GLUC activity and culturable E. coli were observed at the intake, a pattern otherwise ignored by regulatory monitoring. Cross-correlation analysis of time series retrieved from the drinking water intake and an upstream Water Resource Recovery Facility (WRRF) demonstrated a hydraulic connection between the two sites. Sewage by-passes from the same WRRF were the main drivers of intermittent GLUC activity and E. coli peaks at the drinking water intake following intense precipitation and/or snowmelt. Near real-time monitoring of fecal pollution through GLUC activity enabled a thorough characterization of the frequency, duration and amplitude of peak contamination periods at the urban drinking water intake while providing crucial information for the identification of the dominant upstream fecal pollution sources. To the best of our knowledge, this is the first characterization of a hydraulic connection between a WRRF and a downstream drinking water intake across hourly to seasonal timescales using high frequency microbial monitoring data. Ultimately, this should help improve source water protection through catchment mitigation actions, especially in a context of de facto wastewater reuse.


Subject(s)
Drinking Water , Wastewater , Environmental Monitoring , Escherichia coli , Feces , Glucuronidase , Water Microbiology , Water Pollution , Water Supply
2.
Water Res ; 152: 241-250, 2019 04 01.
Article in English | MEDLINE | ID: mdl-30677635

ABSTRACT

Microbiological water quality is traditionally assessed using culture-based enumeration of faecal indicator bacteria such as Escherichia coli. Despite their relative ease of use, these methods require a minimal 18-24 h-incubation step before the results are obtained. This study aimed to assess the suitability of an autonomous online fluorescence-based technology measuring ß-glucuronidase (GLUC) activity for rapid near-real time monitoring of E. coli in water. The analytical precision was determined and compared to an automated microbial detection system, two culture-based assays and quantitative real-time PCR (qPCR). Using replicate measurements of grab samples containing E. coli concentrations between 50 and 2330 CFU.100 mL-1, the autonomous GLUC activity measurement technology displayed an average coefficient of variation (CV) of less than 5% that was 4-8-fold lower than other methods tested. Comparable precision was observed during online in situ monitoring of GLUC activity at a drinking water intake using three independent instruments. GLUC activity measurements were not affected by sewage or sediments at concentrations likely to be encountered during long-term monitoring. Furthermore, significant (p < 0.05) correlations were obtained between GLUC activity and the other assays including defined substrate technology (r = 0.77), membrane filtration (r = 0.73), qPCR (r = 0.55) and the automated microbial detection system (r = 0.50). This study is the first to thoroughly compare the analytical performance of rapid automated detection technologies to established culture and molecular-based methods. Results show that further research is required to correlate GLUC activity to the presence of viable E. coli as measured in terms of CFU.100 mL-1. This would allow the use of autonomous online GLUC activity measurements for rapid E. coli monitoring in water supplies used for drinking water production and recreation.


Subject(s)
Escherichia coli , Glucuronidase , Environmental Monitoring , Water , Water Microbiology