Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 127
Filter
1.
Expert Rev Med Devices ; 21(4): 269-275, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38571391

ABSTRACT

INTRODUCTION: Ruptured abdominal aortic aneurysms (AAAs) pose an immediate threat for patient's life and endovascular repair (EVAR) is currently the preferred treatment modality in the presence of suitable anatomy. This is determined based on the requirements of each endograft as described in the instructions for use (IFU). The new ALTO system (Endologix, Irvin, CA, U.S.A.), can accommodate a great range of anatomies such as short necks and/or narrow access, but its unique design requires specific technical modifications during treatment of ruptured AAAs. AREAS COVERED: The standard double balloon technique has long been described and it is used to provide circulatory support during EVAR for ruptured AAA. While this technique is straightforward with the use of endografts with a traditional design, this would not be the case if one uses the ALTO system. In that case specific maneuvers would be required to treat AAA patients in an acute setting. EXPERT OPINION: The ALTO system although being able to treat AAAs with adverse anatomy, it may not be appropriate during treatment of ruptured AAA patients with profound hemodynamic instability. A careful evaluation of the individual's patient anatomy and hemodynamic condition is mandatory in order to decide the best endograft for each case.

2.
J Clin Orthop Trauma ; 51: 102407, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38681997

ABSTRACT

Although vascular injuries complicate only 1-2% of patients with orthopedic trauma, they may be encountered in a much higher rate of around 10 % in injuries around the knee and elbow joints following both fractures and dislocations. In case of vascular involvement, specific diagnostic and therapeutic challenges arise and there is a higher risk for significant morbidity (i.e. limb loss) or mortality. In the absence of randomized data, diagnostic and therapeutic algorithms are not always straightforward and clinical practice may be based on experience and local protocols rather than firm evidence. With this article we intend to review available literature regarding concomitant skeletal and vascular trauma in order to provide concise information and clear guidelines of when to operate with least investigations and when to go for a full spectrum of investigations in the absence of hard clinical signs. Additionally, other aspects concerning the manipulation of these patients are discussed, such as the indications of primary amputation, the potential role of endovascular techniques and the value of the Resuscitative Endovascular Balloon Occlusion of the Aorta. In summary, this scoping review summarizes current practices in the diagnostic and therapeutic management of patients with concomitant orthopedic and vascular injuries, discusses different treatment strategies and gives a practical perspective for implementation on every day practice.

3.
Article in English | MEDLINE | ID: mdl-38363603

ABSTRACT

PURPOSE: To compare the hemodynamic performance of three (Bottom Up non-ballet, Top-Down non-ballet, Top Down ballet) idealized stent graft configurations used during endovascular repair of abdominal aortic aneurysms, under the influence of various rheological models. METHODS: Ten rheological models are assumed and a commercial finite volume solver is employed for the simulation of blood flow under realistic boundary conditions. An appropriate mesh convergence study is performed and five hemodynamic variables are computed: the time average wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), endothelial cell activation potential and displacement force (DF) for all three configurations. RESULTS: The choice of blood flow model may affect results, but does not constitute a significant determinant on the overall performance of the assumed stent grafts. On the contrary, stent graft geometry has a major effect. Specifically, the Bottom Up non-ballet type is characterized by the least favorable performance presenting the lowest TAWSS and the highest OSI, RRT and ECAP values. On the other hand, the Top Down ballet type presents hemodynamic advantages yielding the highest TAWSS and lowest OSI, RRT and ECAP average values. Furthermore, the ballet type is characterized by the lowest DF, although differences observed are small and their clinical relevance uncertain. CONCLUSIONS: The effect of the assumed rheological model on the overall performance of the grafts is not significant. It is thus relatively safe to claim that it is the type of stent graft that determines its overall performance rather than the adopted blood flow model.

4.
J Endovasc Ther ; : 15266028231214761, 2023 Nov 29.
Article in English | MEDLINE | ID: mdl-38031419

ABSTRACT

PURPOSE: Our objective was to investigate whether patients who receive anticoagulation therapy have different outcomes after endovascular aneurysm repair (EVAR) from those who do not. MATERIALS AND METHODS: We conducted a systematic review of studies that compared outcomes of EVAR in patients who were on therapeutic anticoagulation vs those who were not. We developed and reported the review in accordance with the PRISMA guidelines with a registered protocol (CRD42022375894). The Ovid interface was used to search Medical Literature Analysis and Retrieval System Online (MEDLINE), Excerpta Medica Database (EMBASE), and Cochrane Central Register of Controlled Trials (CENTRAL) up to November 2022. The quality of studies was assessed with the Newcastle-Ottawa Scale (NOS) (maximum score=9), and the evidence was appraised with the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) framework. The hazard ratio (HR) and 95% confidence interval (CI) was the effect estimate in time-to-event meta-analyses, calculated using the inverse-variance statistical method and random-effects models. RESULTS: Sixteen studies qualified for inclusion reporting a total of 35 739 individuals. Anticoagulated patients had a statistically significantly higher hazard of death (HR=1.93, 95% CI=1.03-3.63), endoleak (HR=2.13, 95% CI=1.55-2.93), reintervention (HR=1.79, 95% CI=1.27-2.52), and aneurysm sac expansion (HR=2.72, 95% CI=1.57-4.72) than patients not receiving anticoagulation therapy. The median score on the NOS was 7 (range=4-9). The certainty of evidence was very low for mortality and reintervention and low for endoleak and sac expansion. CONCLUSIONS: Anticoagulation is a poor prognostic factor after standard EVAR and should be considered in decision-making, consent processes, and surveillance strategies. CLINICAL IMPACT: The number of individuals who take anticoagulation treatment has been rapidly increasing over the recent years. We aimed to investigate the effect of such treatment on outcomes after endovascular aneurysm repair (EVAR). Anticoagulated patients were found to have increased mortality, endoleak, and reintervention rates after EVAR compared to their non-anticoagulated counterparts. Anticoagulation therapy has a prognostic role in EVAR and should be considered in decision making and EVAR surveillance. Anticoagulated patients need to be informed of the higher failure rates of EVAR, and intensified surveillance strategies may need to be implemented in this patient cohort.

5.
EJVES Vasc Forum ; 60: 24-27, 2023.
Article in English | MEDLINE | ID: mdl-37547924

ABSTRACT

Introduction: Several surgical and endovascular techniques are used during the treatment of aorto-iliac occlusive disease. Aortobifemoral bypass (AoBFB) is the standard of care, but other options such as axillobifemoral (AxBFB) bypass, aorto-iliac kissing stents (KS), and covered endovascular reconstruction of aortic bifurcation (CERAB) are also available. This study aimed to perform a computational comparison of these four modalities to investigate their haemodynamic performance. Report: Eight patient specific anatomies were analysed, with each of the abovementioned techniques used to treat two anatomies. The CT angiograms were segmented from the renal (or axillary) to common femoral arteries and the 3D geometries were exported. A commercial finite volume solver was implemented for numerical simulations. Outcomes that were assessed were pressure drop (ΔP) between the inlet and the outlet for every configuration and haemodynamic indices of Time Average Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI), and Relative Residence Time (RRT) as markers of a thrombogenic environment. The results indicate that maximum ΔP was observed at peak systole for all models, with values ranging between 12 mmHg and 21 mmHg for the AoBFB, 64 mmHg and 96 mmHg for the AxBFB, 31 mmHg and 46 mmHg for the KS, and 43 mmHg and 46 mmHg for the CERAB configuration. TAWSS, OSI, and RRT varied among different configurations, mostly presenting values well above thrombogenic thresholds. Regarding RRT, the percentage of total surface area presenting such values is 2.5%, 3.2%, 2%, and 4.3% for the AoBFB, AxBFB, KS, and CERAB configurations, respectively. Discussion: Computational modelling indicates a favourable haemodynamic performance of AoBFB compared with the other configurations. This leads to a smaller pressure drop and sconsequently a higher pressure in the outlet of the conduit, which is the perfusion pressure of the limb. Notably, lower patency rates of the latter modalities cannot be explained based on haemodynamic indices.

7.
Bioengineering (Basel) ; 10(7)2023 Jun 28.
Article in English | MEDLINE | ID: mdl-37508803

ABSTRACT

During the vascular surgical reconstruction of aorto-iliac occlusive/aneurysmal disease, bifurcated grafts are used where vascular surgeons intra-operatively select the size and the relative lengths of the parent and daughter portions of the graft. Currently, clinical practice regarding the selection of the most favorable geometric configuration of the graft is an understudied research subject: decisions are solely based on the clinical experience of the operating surgeon. This manuscript aims to evaluate the hemodynamic performance of various diameters, D, of bifurcated aortic grafts and relate those with proximal/distal part length ratios (the angle φ between the limbs is used as a surrogate marker of the main body-to-limb length ratio) in order to provide insights regarding the effects of different geometries on the hemodynamic environment. To this end, a computationally intensive set of simulations is conducted, and the resulting data are analyzed with modern statistical regression tools. A negative curvilinear relationship of TAWSS with both φ and D is recorded. It is shown that the angle between limbs is a more important predictor for the variability of TAWSS, while the graft's diameter is an important determinant for the variability of OSI. Large percentages of the total graft area with TAWSS < 0.4 Pa, which correspond to thrombogenic stimulating environments, are only observed for large values of φ and D > 20 mm. This variable ranges from 10% (for the smallest values of φ and D) to 55% (for the largest φ and D values). Our findings suggest that grafts with the smallest possible angle between the limbs (i.e., smallest parent-to-daughter length ratio) present the most favorable hemodynamic performance, yielding the smallest percentage of total graft area under thrombogenic simulating environments. Similarly, grafts with the smallest acceptable diameter should be preferred for the same reason. Especially, grafts with diameters greater than 20 mm should be avoided, given the abrupt increase in estimated thrombogenic areas.

10.
Aorta (Stamford) ; 11(2): 57-62, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37055015

ABSTRACT

BACKGROUND: Abdominal compartment syndrome (ACS) often complicates ruptured abdominal aortic aneurysm (rAAA) repair. We report results with routine skin-only abdominal wound closure after rAAA surgical repair. METHODS: This was a single-center retrospective study including consecutive patients undergoing rAAA surgical repair for the duration of 7 years. Skin-only closure was routinely performed, and if possible, secondary abdominal closure was performed during the same admission. Demographic information, preoperative hemodynamic condition, and perioperative information (ACS, mortality, rate of abdominal closure, and postoperative outcomes) were collected. RESULTS: During the study period, 93 rAAAs were recorded. Ten patients were too frail to undergo repair or refused treatment. Eighty-three patients underwent immediate surgical repair. The mean age was 72.4 ± 10.5 years, and the vast majority were male (82:1). Preoperative systolic blood pressure <90 mm Hg was recorded in 31 patients. Intraoperative mortality was recorded in nine cases. Overall in-hospital mortality was 34.9% (29/83). Primary fascial closure was performed in five patients, while skin-only closure was performed in 69. ACS was recorded in two cases in whom skin sutures were removed and negative pressure wound treatment was applied. Secondary fascial closure was feasible in 30 patients during the same admission. Among 37 patients not undergoing fascial closure, 18 died and 19 survived and were discharged with a planned ventral hernia repair. Median length of intensive care unit and hospital stay were 5 (1-24) and 13 (8-35) days, respectively. After a mean follow-up of 21 months, telephone contact was possible with 14/19 patients who left the hospital with an abdominal hernia. Three reported hernia-related complications mandating surgical repair, while in 11, this was well tolerated. CONCLUSION: Routine skin-only closure during rAAA surgical repair results in low rates of ACS at the expense of a high rate of patients being discharged with a planned ventral hernia which, however, seems to be well tolerated by the majority of patients.

11.
Ann Vasc Surg ; 93: 338-350, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36868463

ABSTRACT

BACKGROUND: Abdominal aortic aneurysms (AAAs) are currently treated based on the universal maximum diameter criterion, but other geometric variables may play a role in the risk of rupture. The hemodynamic environment inside the AAA sac has been shown to interact with several biologic processes which can affect prognosis. AAA geometric configuration has a significant impact in the hemodynamic conditions that develop, which has only been recently realized, with implications for rupture risk estimations. We aim to perform a parametric study to evaluate the effect of aortic neck angulation, angle between the iliac arteries, and sac asymmetry (SA) on the hemodynamic variables of AAAs. METHODS: This study uses idealized AAA models and it is parametrized in terms of 3 quantities as follows: the neck angle, φ (°), iliac angle, θ (°), and SA (%), each of which accepts 3 different values, specifically φ = (0°, 30°, 60°), θ = (40°, 60°, 80°), and SA = (S, °SS, °OS), where the SA can either be on the same side with respect to neck (SS) or on the opposite side (OS). Time average wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and the velocity profile are calculated for different geometric configurations, while the percentage of the total surface area under thrombogenic conditions, using thresholds previously reported in the literature, is also recorded. RESULTS: In case of an angulated neck and a higher angle between iliac arteries, favorable hemodynamic conditions are predicted with higher TAWSS and lower OSI and RRT values. The area under thrombogenic conditions reduces by 16-46% as the neck angle increases from 0° to 60°, depending on the hemodynamic variable under consideration. The effect of iliac angulation is present but less pronounced with 2.5-7.5% change between the lower and the higher angle. The effect of SA seems to be significant for OSI, with a nonsymmetrical configuration being hemodynamically favorable, which in the presence of an angulated neck is more pronounced for the OS outline. CONCLUSIONS: Favorable hemodynamic conditions develop inside the sac of idealized AAAs with increasing neck and iliac angles. Regarding the SA parameter, asymmetrical configurations most often appear advantageous. Concerning the velocity profile the triplet (φ, θ, SA) may affect outcomes under certain conditions and thus should be taken into account when parametrizing the geometric characteristics of AAAs.


Subject(s)
Aortic Aneurysm, Abdominal , Humans , Treatment Outcome , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Hemodynamics , Stress, Mechanical , Rupture
12.
Bioengineering (Basel) ; 10(2)2023 Feb 20.
Article in English | MEDLINE | ID: mdl-36829766

ABSTRACT

BACKGROUND: The effects of non-Newtonian rheology and boundary conditions on various pathophysiologies have been studied quite extensively in the literature. The majority of results present qualitative and/or quantitative conclusions that are not thoroughly assessed from a statistical perspective. METHODS: The finite volume method was employed for the numerical simulation of seven patient-specific abdominal aortic aneurysms. For each case, five rheological models and three inlet velocity boundary conditions were considered. Outlier- and heteroscedasticity-robust ANOVA tests assessed the simultaneous effect of rheological specifications and boundary conditions on fourteen variables that capture important characteristics of vascular flows. RESULTS: The selection of inlet velocity profiles appears as a more critical factor relative to rheological specifications, especially regarding differences in the oscillatory characteristics of computed flows. Response variables that relate to the average tangential force on the wall over the entire cycle do not differ significantly across alternative factor levels, as long as one focuses on non-Newtonian specifications. CONCLUSIONS: The two factors, namely blood rheological models and inlet velocity boundary condition, exert additive effects on variables that characterize vascular flows, with negligible interaction effects. Regarding thrombus-prone conditions, the Plug inlet profile offers an advantageous hemodynamic configuration with respect to the other two profiles.

15.
Ann Vasc Surg ; 91: 90-107, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36494004

ABSTRACT

BACKGROUND: To investigate outcomes of pre-emptive embolization of the aneurysm sac or aortic side branches in endovascular aneurysm repair (EVAR). METHODS: The review was reported as per Preferred Reporting Items for Systematic reviews and Meta-Analyses 2020 with a preregistered protocol. Bibliographic sources (MEDLINE, Embase, and CENTRAL) were searched using subject headings and free text terms. Randomized controlled trials comparing EVAR with versus without embolization were included. Pooled estimates of dichotomous outcomes were calculated using odds ratio (OR) or risk difference (RD) and 95% confidence interval (CI) applying the Mantel-Haenszel method. Continuous outcomes were summarized using mean difference (MD) and 95% CI applying the inverse variance method. The certainty of evidence was appraised with the Grading of Recommendations Assessment, Development, and Evaluation framework. Version 2 of the Cochrane tool was used to assess the risk of bias. Trial sequential analysis assumed alpha = 5% and power = 80%. RESULTS: Four randomized controlled trials were included. No significant difference was found in aneurysm-related mortality (RD 0.00, 95% CI -0.03 to 0.03), overall mortality (OR 1.85, 95% CI 0.42-8.13), aneurysm rupture (RD 0.00, 95% CI -0.03 to 0.03), type II endoleak-related reintervention (RD -0.07, 95% CI -0.21 to 0.06), procedure time (MD 20.12, 95% CI -11.54 to 51.77), or fluoroscopy time (MD 11.17, 95% CI -11.22 to 33.56). Patients with pre-emptive embolization had significantly lower odds of type II endoleak (OR 0.45, 95% CI 0.26-0.78) and sac expansion (OR 0.19, 95% CI 0.07-0.52). The risk of bias was high for all outcomes. The certainty of evidence was very low for all outcomes, except for type II endoleak, for which it was low. Trial sequential analysis showed an inconclusive result for overall mortality and type II endoleak-related reintervention but confirmed the advantage of embolization in reducing type II endoleak and sac expansion. CONCLUSIONS: Limited, low certainty data suggest pre-emptive embolization confers no clinical benefits in EVAR.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Endovascular Procedures , Humans , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Endovascular Aneurysm Repair , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/prevention & control , Treatment Outcome , Blood Vessel Prosthesis Implantation/adverse effects , Randomized Controlled Trials as Topic , Embolization, Therapeutic/adverse effects , Risk Factors
16.
Vascular ; 31(3): 409-416, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35687809

ABSTRACT

OBJECTIVES: To develop a prediction model that could risk stratify abdominal aortic aneurysms (AAAs) into high and low growth rate groups, using machine learning algorithms based on variables from different pathophysiological fields. METHODS: A cohort of 40 patients with small AAAs (maximum diameter 32-53 mm) who had at least an initial and a follow-up CT scan (median follow-up 12 months, range 3-36 months) were included. 29 input variables from clinical, biological, morphometric, and biomechanical pathophysiological aspects extracted for predictive modeling. Collected data were used to build two supervised machine learning models. A gradient boosting (XGboost) and a support vector machines (SVM) algorithm were trained with 60% and tested with 40% of the data to predict which AAA would achieve a growth rate higher than the median of our study cohort. Receiver operating characteristics (ROC) curves and areas under the curve (AUC) were used for the evaluation of the developed algorithms. RESULTS: XGboost achieved the highest AUC in predicting high compared to low AAA growth rate with an AUC of 81.2% (95% CI from 61.1 to 100%). SVM achieved the second highest performance with an AUC of 68.8% (95% CI from 46.5 to 91%). Based on the best performing algorithm, variable importance was estimated. Diameter-diameter ratio (maximum diameter/neck diameter), Tortuosity from Renal arteries to aortic bifurcation, and maximum thickness of the intraluminal thrombus were found to be the most important factors for model predictions. Other factors were also found to play a significant but less important role. CONCLUSIONS: A prediction model that can risk stratify AAAs into high and low growth rate groups could be developed by analyzing several factors implicated in the multifactorial pathophysiology of this disease, with the use of machine learning algorithms. Future studies including larger patient cohorts and implementing additional risk markers may aid in the establishment of such methodology during AAA rupture risk estimation.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Rupture , Biological Products , Humans , Artificial Intelligence , Aortic Aneurysm, Abdominal/diagnostic imaging , Aorta, Abdominal , Tomography, X-Ray Computed , Risk Factors
17.
Ann Vasc Surg ; 88: 337-345, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35921980

ABSTRACT

BACKGROUND: Patients with wide aortic necks undergoing Endovascular Aneurysm Repair (EVAR) have been shown to be at a higher risk for neck-related complications. We aim to examine outcomes of EVAR with an endograft exerting minimal outward pressure (Ovation-Endologix) in patients with a large baseline neck diameter. METHODS: We performed a retrospective single center study, including consecutive patients undergoing EVAR with the Ovation system from May 2011 to April 2021. Patients were divided in Groups 1 and 2 if the 20, 23, 26, 29 mm or the 34 mm proximal diameter main body was used, respectively. According to the instructions for use of the device, for neck diameters 27-30 mm the 34 mm main body is required. Primary endpoint was rate of neck related complications during follow-up, (type Ia endoleak, migration >10 mm and neck-related re-interventions) and rate of aortic neck dilatation (AND). AND was determined based on multiple aortic neck diameters that were recorded and compared between the 1-month computed tomography angiography (CTA) after EVAR and the last available follow-up CTA.Secondary endpoints were peri-procedural and follow-up outcomes such as endoleaks, reinterventions and overall mortality. RESULTS: In total 281 patients were included, 222 in Group 1 and 59 in Group 2. Patients in Group 2 presented significantly shorter neck length, higher neck angulation and more common reversed tapered configuration. Median follow-up was 36 months (Range: 6-106). Early and late type Ia endoleak was observed in 4 and 2 patients in each group, respectively (P = 0.063 and P = 0.195, respectively). Distal migration was observed in 2 patients in Group 2 and AND was recorded in 2 patients in each group (P = 0.195). Freedom from the primary endpoint was estimated at 98%, 94%, 94% at 12-, 36-, 60-months for Group 1 and at 98%, 95%, 86% for Group 2 (P-Value 0.266). Probability of survival was 95%, 86%, 75% at 12-, 36-, 60-months for Group 1 and 83%, 77%, 72% for Group 2 (P-Value 0.226).Multivariate regression analysis identified neither Group 1 versus Group 2 nor absolute value of aortic neck diameter as significant predictors of neck-related adverse events. Neck diameters did not display significant differences over time in any of the levels evaluated. CONCLUSIONS: EVAR with the Ovation endograft results in low rates of late neck related complications which is also true for patients with wide baseline aortic necks.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Endoleak/diagnostic imaging , Endoleak/etiology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Blood Vessel Prosthesis/adverse effects , Retrospective Studies , Endovascular Aneurysm Repair , Treatment Outcome , Risk Factors , Time Factors
18.
J Ultrason ; 22(91): e245-e248, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36483787

ABSTRACT

We present a rare case of a common carotid artery wall hematoma after ultrasound-guided parathyroid fine-needle aspiration. The hematoma was detected within seconds from needle insertion, extending along the common carotid artery wall from the lower neck to the common carotid artery bifurcation, and it was quickly restricted with firm pressure. The patient only reported mild discomfort. A follow-up assessment by a vascular surgeon two hours later showed no signs of ischemic events and complete absorption of the hematoma without further clinical consequences. Physicians performing parathyroid fine-needle aspiration must be aware of this rare complication, which may be easily overlooked. Continuous meticulous sonographic surveillance during the fine needle aspiration procedure is the only way to directly diagnose this complication and apply immediate pressure to restrict it.

19.
J Vasc Interv Radiol ; 33(12): 1531-1535, 2022 12.
Article in English | MEDLINE | ID: mdl-36100065

ABSTRACT

This study investigated the role of dual-energy computed tomography (CT) for lesion characterization in patients with peripheral arterial disease manifesting with chronic total occlusions (CTOs). Forty-one symptomatic patients with CTOs underwent dual-energy CT angiography before endovascular treatment. The lesions were subsequently analyzed in a dedicated workstation, and 2 indexes-dual-energy index (DEI) and effective Z (Zeff)-were calculated, ranging from 0.0027 to 0.321 and from 6.89 to 13.02, respectively. Statistical analysis showed a significant correlation between the DEI and Zeff values (P < .001). The interobserver intraclass correlation coefficient was 0.91 for the mean Zeff values and 0.86 for the mean DEI values. This technique could potentially provide useful information regarding the composition of a CTO.


Subject(s)
Peripheral Arterial Disease , Tomography, X-Ray Computed , Humans , Feasibility Studies , Tomography, X-Ray Computed/methods , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Angiography , Chronic Disease
SELECTION OF CITATIONS
SEARCH DETAIL
...