Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
2.
Phys Rev Lett ; 119(16): 162501, 2017 Oct 20.
Article in English | MEDLINE | ID: mdl-29099223

ABSTRACT

The charge and magnetic form factors, F_{C} and F_{M}, respectively, of ^{3}He are extracted in the kinematic range 25 fm^{-2}≤Q^{2}≤61 fm^{-2} from elastic electron scattering by detecting ^{3}He recoil nuclei and scattered electrons in coincidence with the two High Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The measurements find evidence for the existence of a second diffraction minimum for the magnetic form factor at Q^{2}=49.3 fm^{-2} and for the charge form factor at Q^{2}=62.0 fm^{-2}. Both minima are predicted to exist in the Q^{2} range accessible by this Jefferson Lab experiment. The data are in qualitative agreement with theoretical calculations based on realistic interactions and accurate methods to solve the three-body nuclear problem.

3.
Biomicrofluidics ; 9(6): 064107, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26634015

ABSTRACT

The flow focusing is a fundamental prior step in order to sort, analyze, and detect particles or cells. The standard hydrodynamic approach requires two fluids to be injected into the microfluidic device: one containing the sample and the other one, called the sheath fluid, allows squeezing the sample fluid into a narrow stream. The major drawback of this approach is the high complexity of the layout for microfluidic devices when parallel streams are required. In this work, we present a novel parallelized microfluidic device that enables hydrodynamic focusing in each microchannel using a single feed flow. At each of the parallel channels, a cross-filter region is present that allows removing fluid from the sample fluid. This fluid is used to create local sheath fluids that hydrodynamically pinch the sample fluid. The great advantage of the proposed device is that, since only one inlet is needed, multiple parallel micro-channels can be easily introduced into the design. In the paper, the design method is described and the numerical simulations performed to define the optimal design are summarized. Moreover, the operational functionality of devices tested by using both polystyrene beads and Acute Lymphoid Leukemia cells are shown.

4.
Phys Rev Lett ; 113(2): 022502, 2014 Jul 11.
Article in English | MEDLINE | ID: mdl-25062169

ABSTRACT

We report the first measurement of the target-normal single-spin asymmetry in deep-inelastic scattering from the inclusive reaction 3)He(↑)(e,e')X on a polarized (3)He gas target. Assuming time-reversal invariance, this asymmetry is strictly zero in the Born approximation but can be nonzero if two-photon-exchange contributions are included. The experiment, conducted at Jefferson Lab using a 5.89 GeV electron beam, covers a range of 1.72 GeV, which is nonzero at the 2.89σ level. Our measured asymmetry agrees both in sign and magnitude with a two-photon-exchange model prediction that uses input from the Sivers transverse momentum distribution obtained from semi-inclusive deep-inelastic scattering.

5.
Phys Rev Lett ; 112(13): 132503, 2014 Apr 04.
Article in English | MEDLINE | ID: mdl-24745410

ABSTRACT

The charge form factor of 4He has been extracted in the range 29 fm(-2) ≤ Q2 ≤ 77 fm(-2) from elastic electron scattering, detecting 4He recoil nuclei and electrons in coincidence with the high resolution spectrometers of the Hall A Facility of Jefferson Lab. The measurements have uncovered a second diffraction minimum for the form factor, which was predicted in the Q2 range of this experiment. The data are in qualitative agreement with theoretical calculations based on realistic interactions and accurate methods to solve the few-body problem.

6.
Opt Lett ; 38(11): 1951-3, 2013 Jun 01.
Article in English | MEDLINE | ID: mdl-23722800

ABSTRACT

We report on a method for surface plasmon resonance (SPR) refractive index sensing based on direct time-domain measurements. An optical resonator is built around an SPR sensor, and its photon lifetime is measured as a function of loss induced by refractive index variations. The method does not rely on any spectroscopic analysis or direct intensity measurement. Time-domain measurements are practically immune to light intensity fluctuations and thus lead to high resolution. A proof of concept experiment is carried out in which a sensor response to liquid samples of different refractive indices is measured. A refractive index resolution of the current system, extrapolated from the reproducibility of cavity-decay time determinations over 133 s, is found to be about 10(-5) RIU. The possibility of long-term averaging suggests that measurements with a resolution better than 10(-7) RIU/√Hz are within reach.


Subject(s)
Optical Phenomena , Surface Plasmon Resonance/methods , Time Factors
7.
Opt Express ; 21(23): 28072-82, 2013 Nov 18.
Article in English | MEDLINE | ID: mdl-24514321

ABSTRACT

Design, fabrication, and characterization of an asymmetric metal-semiconductor-metal photodetector, based on internal photoemission effect and integrated into a silicon-on-insulator waveguide, are reported. For this photodetector, a responsivity of 4.5 mA/W has been measured at 1550 nm, making it suitable for power monitoring applications. Because the absorbing metal is deposited strictly around the vertical output facet of the waveguide, a very small contact area of about 3 µm2 is obtained and a transit-time-limited bandwidth of about 1 GHz is demonstrated. Taking advantage of this small area and electrode asymmetry, a significant reduction in the dark current (2.2 nA at -21 V) is achieved. Interestingly, applying reverse voltage, the photodetector is able to tune its cut-off wavelength, extending its range of application into the MID infrared regime.

8.
Phys Rev Lett ; 103(20): 202501, 2009 Nov 13.
Article in English | MEDLINE | ID: mdl-20365979

ABSTRACT

An experimental study of the (16)O(e,e'K(+))(Lambda)(16)N reaction has been performed at Jefferson Lab. A thin film of falling water was used as a target. This permitted a simultaneous measurement of the p(e,e'K(+))Lambda, Sigma(0) exclusive reactions and a precise calibration of the energy scale. A ground-state binding energy of 13.76+/-0.16 MeV was obtained for (Lambda)(16)N with better precision than previous measurements on the mirror hypernucleus (Lambda)(16)O. Precise energies have been determined for peaks arising from a Lambda in s and p orbits coupled to the p(1/2) and p(3/2) hole states of the (15)N core nucleus.

9.
Phys Rev Lett ; 101(2): 022303, 2008 Jul 11.
Article in English | MEDLINE | ID: mdl-18764175

ABSTRACT

We present a measurement of the spin-dependent cross sections for the 3He over -->(e over -->,e')X reaction in the quasielastic and resonance regions at a four-momentum transfer 0.1< or =Q2< or =0.9 GeV2. The spin-structure functions have been extracted and used to evaluate the nuclear Burkhardt-Cottingham and extended Gerasimov-Drell-Hearn sum rules for the first time. The data are also compared to an impulse approximation calculation and an exact three-body Faddeev calculation in the quasielastic region.

10.
Phys Rev Lett ; 99(5): 052501, 2007 Aug 03.
Article in English | MEDLINE | ID: mdl-17930747

ABSTRACT

An experiment measuring electroproduction of hypernuclei has been performed in hall A at Jefferson Lab on a 12C target. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring imaging Cherenkov detector were added to the hall A standard equipment. An unprecedented energy resolution of less than 700 keV FWHM has been achieved. Thus, the observed (Lambda)(12)B spectrum shows for the first time identifiable strength in the core-excited region between the ground-state s-wave Lambda peak and the 11 MeV p-wave Lambda peak.

11.
Opt Lett ; 31(21): 3164-6, 2006 Nov 01.
Article in English | MEDLINE | ID: mdl-17041669

ABSTRACT

An optical phase array with tunable phase step is demonstrated. The phase array consists of a two-dimensional hexagonal lattice of inverted ferroelectric domains fabricated on a Z-cut lithium niobate substrate. The electro-optically tunable phase step is obtained by the application of an external electric field along the z axis of the crystal via transparent electrodes. Theoretical analysis and experimental results are presented, showing that a tunable and flexible adaptive optical illuminator device can be realized by combining the electro-optic tunability with the Talbot effect. Generation of a multiplicity of light patterns is shown.

12.
Opt Express ; 14(12): 5266-78, 2006 Jun 12.
Article in English | MEDLINE | ID: mdl-19516692

ABSTRACT

In this paper, static and dynamic thermo-optical numerical analysis of a Digital Optical Switch (DOS), based on amorphous silicon waveguide and operating at the infrared communications wavelength of 1550 nm, are presented. The aim of our design is to achieve good performances in terms of cross talk and switching time, considering relaxed requirements for the realization of device: large cross section single mode waveguides and an angle between the output branches not too small. Using a low temperature difference between the two output branches, an optical switching with a crosstalk of 25 dB and a response time of the order of ten microseconds are obtained. The device, designed for low-cost photonic applications, could be easily integrated in silicon optoelectronic circuits.

13.
Minerva Pediatr ; 57(5): 203-11, 2005 Oct.
Article in Italian | MEDLINE | ID: mdl-16205605

ABSTRACT

Osteoporosis is a common disease characterized by reduced bone mass, with a consequent increase in bone fragility and susceptibility to fracture risk. Bone mineral density (BMD) measurement is used to make the diagnosis of osteoporosis prior to incident fracture, and to predict fracture risk. BMD is determined by the peak bone mass achieved, and the rate and timing of subsequent bone loss. Dual-energy X-ray absorptiometry (DEXA) is the most popular and effective method utilized for osteoporosis screening. Bone disease is a side effect of concern regarding chronic glucocorticoid (GC) administration. Most GC-treated patients exhibit a process of bone loss, frequently leading to osteoporosis, with increased fracture risk, especially in spinal vertebrae. Osteogenesis imperfecta is an inherited and generalized connective tissue disorder characterized mainly by bone fragility. Idiopathic osteoporosis of childhood or adolescence without blue sclerae and other stigmata of osteogenesis imperfecta is occasionally observed and sometimes more than one sib is affected. Beta-thalassemia major is associated with significant bone disease. The etiology of the bone disease is still debatable, many factors can adversely affect bone accretion in thalassemic patients. These include delayed puberty, bone marrow expansion, the deleterious effects of desferrioxamine, iron overload and genetic factors. Current treatment alternatives of osteoporosis include bisphosphonates, calcitonin, and selective estrogen receptor modulators.


Subject(s)
Osteoporosis , Absorptiometry, Photon , Adolescent , Adult , Age Factors , Bone Density , Calcitonin/therapeutic use , Child , Child, Preschool , Diagnosis, Differential , Diphosphonates/therapeutic use , Female , Glucocorticoids/adverse effects , Humans , Male , Osteogenesis Imperfecta/classification , Osteogenesis Imperfecta/diagnosis , Osteoporosis/chemically induced , Osteoporosis/diagnosis , Osteoporosis/drug therapy , Osteoporosis/etiology , Selective Estrogen Receptor Modulators/therapeutic use , Thalassemia/complications
14.
Phys Rev Lett ; 95(10): 102001, 2005 Sep 02.
Article in English | MEDLINE | ID: mdl-16196919

ABSTRACT

We measured angular distributions of recoil-polarization response functions for neutral pion electroproduction for W = 1.23 GeV at Q(2) = 1.0 (GeV/c)(2), obtaining 14 separated response functions plus 2 Rosenbluth combinations; of these, 12 have been observed for the first time. Dynamical models do not describe quantities governed by imaginary parts of interference products well, indicating the need for adjusting magnitudes and phases for nonresonant amplitudes. We performed a nearly model-independent multipole analysis and obtained values for Re (S(1+)/M(1+)) = -(6.84 +/- 0.15)% and Re (E(1+)/M(1+)) = -(2.91 +/- 0.19)% that are distinctly different from those from the traditional Legendre analysis based upon M1+ dominance and ll(pi) < or = 1 truncation.

15.
Phys Rev Lett ; 94(19): 192302, 2005 May 20.
Article in English | MEDLINE | ID: mdl-16090165

ABSTRACT

We have studied the quasielastic 3He(e,e(')p)2H reaction in perpendicular coplanar kinematics, with the energy and the momentum transferred by the electron fixed at 840 MeV and 1502 MeV/c, respectively. The 3He(e,e(')p)2H cross section was measured for missing momenta up to 1000 MeV/c, while the A(TL) asymmetry was extracted for missing momenta up to 660 MeV/c. For missing momenta up to 150 MeV/c, the cross section is described by variational calculations using modern 3He wave functions. For missing momenta from 150 to 750 MeV/c, strong final-state interaction effects are observed. Near 1000 MeV/c, the experimental cross section is more than an order of magnitude larger than predicted by available theories. The A(TL) asymmetry displays characteristic features of broken factorization with a structure that is similar to that generated by available models.

16.
Phys Rev Lett ; 94(8): 082305, 2005 Mar 04.
Article in English | MEDLINE | ID: mdl-15783882

ABSTRACT

Results of the Jefferson Lab Hall A quasielastic 3He(e,e'p)pn measurements are presented. These measurements were performed at fixed transferred momentum and energy, q=1502 MeV/c and omega=840 MeV, respectively, for missing momenta p(m) up to 1 GeV/c and missing energies in the continuum region, up to pion threshold; this kinematic coverage is much more extensive than that of any previous experiment. The cross section data are presented along with the effective momentum density distribution and compared to theoretical models.

17.
Phys Rev Lett ; 93(15): 152301, 2004 Oct 08.
Article in English | MEDLINE | ID: mdl-15524867

ABSTRACT

The generalized forward spin polarizabilities gamma(0) and delta(LT) of the neutron have been extracted for the first time in a Q2 range from 0.1 to 0.9 GeV2. Since gamma(0) is sensitive to nucleon resonances and delta(LT) is insensitive to the Delta resonance, it is expected that the pair of forward spin polarizabilities should provide benchmark tests of the current understanding of the chiral dynamics of QCD. The new results on delta(LT) show significant disagreement with chiral perturbation theory calculations, while the data for gamma(0) at low Q2 are in good agreement with a next-to-leading-order relativistic baryon chiral perturbation theory calculation. The data show good agreement with the phenomenological MAID model.

18.
Phys Rev Lett ; 92(2): 022301, 2004 Jan 16.
Article in English | MEDLINE | ID: mdl-14753931

ABSTRACT

We have measured the spin structure functions g(1) and g(2) of 3He in a double-spin experiment by inclusively scattering polarized electrons at energies ranging from 0.862 to 5.058 GeV off a polarized 3He target at a 15.5 degrees scattering angle. Excitation energies covered the resonance and the onset of the deep inelastic regions. We have determined for the first time the Q2 evolution of Gamma(1)(Q2)= integral (1)(0)g(1)(x,Q2)dx, Gamma(2)(Q2)= integral (1)(0)g(2)(x,Q2)dx, and d(2)(Q2)= integral (1)(0)x(2)[2g(1)(x,Q2)+3g(2)(x,Q2)]dx for the neutron in the range 0.1< or =Q2< or =0.9 GeV2 with good precision. Gamma(1)(Q2) displays a smooth variation from high to low Q2. The Burkhardt-Cottingham sum rule holds within uncertainties and d(2) is nonzero over the measured range.

19.
Phys Rev Lett ; 89(24): 242301, 2002 Dec 09.
Article in English | MEDLINE | ID: mdl-12484938

ABSTRACT

We present data on the inclusive scattering of polarized electrons from a polarized 3He target at energies from 0.862 to 5.06 GeV, obtained at a scattering angle of 15.5 degrees. Our data include measurements from the quasielastic peak, through the nucleon resonance region, and beyond, and were used to determine the virtual photon cross-section difference sigma(1/2)-sigma(3/2). We extract the extended Gerasimov-Drell-Hearn integral for the neutron in the range of four-momentum transfer squared Q2 of 0.1-0.9 GeV2.

20.
Phys Rev Lett ; 88(9): 092301, 2002 Mar 04.
Article in English | MEDLINE | ID: mdl-11863996

ABSTRACT

The ratio of the electric and magnetic form factors of the proton G(E(p))/G(M(p)), which is an image of its charge and magnetization distributions, was measured at the Thomas Jefferson National Accelerator Facility (JLab) using the recoil polarization technique. The ratio of the form factors is directly proportional to the ratio of the transverse to longitudinal components of the polarization of the recoil proton in the elastic e(-->)p---> e(-->)p reaction. The new data presented span the range 3.5< Q(2)< 5.6 GeV(2) and are well described by a linear Q(2) fit. Also, the ratio sqrt[Q(2)] F(2(p))/F(1(p)) reaches a constant value above Q(2) = 2 GeV(2).

SELECTION OF CITATIONS
SEARCH DETAIL
...