Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
PLoS One ; 16(7): e0253019, 2021.
Article in English | MEDLINE | ID: mdl-34237065

ABSTRACT

BACKGROUND: Although the pedicle is routinely used as a surgical fixation site, the pedicle wall bone area fraction (bone area per unit area) and its distribution at the isthmus of the pedicle remain unknown. The bone area fraction at the pedicle isthmus is an important factor contributing to the strength of pedicle screw constructs. This study investigates the lumbar pedicle wall microstructure based on micro-computed tomography. METHODS: Six fresh-frozen cadaveric lumbar spines were analyzed. Left and right pedicles of each vertebra from L1 to L5 were resected for micro-computed tomography scanning. Data was analyzed with custom-written software to determine regional variation in pedicle wall bone area fraction. The pedicular cross-section was divided into four regions: lateral, medial, cranial, and caudal. The mean bone area fraction values for each region were calculated for all lumbar spine levels. RESULTS: The lateral region showed lower bone area fraction than the medial region at all spinal levels. Bone area fraction in the medial region was the highest at all levels except for L4, and the median values were 99.8% (95.9-100%). There were significant differences between the lateral region and the caudal region at L1, L2 and L3, but none at L4 and L5. The bone area fraction in the lateral region was less than 64% at all spinal levels and that in the caudal region was less than 67% at the L4 and L5 levels. CONCLUSIONS: This study provides initial detailed data on the lumbar pedicle wall microstructure based on micro-computed tomography. These findings may explain why there is a higher incidence of pedicle screw breach in the pedicle lateral and caudal walls.


Subject(s)
Lumbar Vertebrae/diagnostic imaging , Aged , Female , Humans , Lumbar Vertebrae/anatomy & histology , Lumbar Vertebrae/ultrastructure , Male , Middle Aged , X-Ray Microtomography/methods
2.
Sci Rep ; 11(1): 1709, 2021 01 18.
Article in English | MEDLINE | ID: mdl-33462307

ABSTRACT

This study investigated in vivo the three-dimensional distribution of CT attenuation in the lumbar spine pedicle wall measured in Hounsfield Unit (HU). Seventy-five volunteers underwent clinical lumbar spine CT scans. Data was analyzed with custom-written software to determine the regional variation in pedicle wall attenuation values. A cylindrical coordinate system oriented along the pedicle's long axis was used to calculate the pedicular wall attenuation distribution three-dimensionally and the highest attenuation value was identified. The pedicular cross-section was divided into four quadrants: lateral, medial, cranial, and caudal. The mean HU value for each quadrant was calculated for all lumbar spine levels (L1-5). The pedicle wall attenuation was analyzed by gender, age, spinal levels and anatomical quadrant. The mean HU values of the pedicle wall at L1 and L5 were significantly lower than the values between L2-4 in both genders and in both age groups. Furthermore, the medial quadrant showed higher HU values than the lateral quadrant at all levels and the caudal quadrant showed higher HU values at L1-3 and lower HU values at L4-5 than the cranial quadrant. These findings may explain why there is a higher incidence of pedicle screw breach in the pedicle lateral wall.


Subject(s)
Lumbar Vertebrae/diagnostic imaging , Tomography, X-Ray Computed , Adult , Female , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Lumbar Vertebrae/physiology , Male , Middle Aged , Vertebral Body/diagnostic imaging , Vertebral Body/physiology , Young Adult
3.
Arthroscopy ; 36(10): 2623-2632, 2020 10.
Article in English | MEDLINE | ID: mdl-32534004

ABSTRACT

PURPOSE: (1) To compare the acetabular coverage between dysplasia, borderline dysplasia, and control acetabulum in a quantitative 3-dimensional manner; and (2) to evaluate correlations between the radiologic parameters and the 3-dimensional zonal-acetabular coverage. METHODS: We reviewed contralateral hip computed tomography images of patients 16 to 60 years of age who underwent 1 of 3 types of surgeries: eccentric rotational acetabular osteotomy, curved intertrochanteric varus osteotomy, and total hip replacement with minimum 1-year follow-up from January 2013 to April 2018. A point-cloud model of the acetabulum created from computed tomography was divided into 6 zones. Three-dimensional acetabular coverage was measured radially at intervals of 1°. Mean radial acetabular coverage for each zone was named ZAC (zonal acetabular coverage) and was compared among the 3 subgroups (control: 25° ≤lateral center-edge angle [LCEA] <40°; borderline: 20° ≤LCEA <25°; and dysplasia: LCEA ≤20°) statistically. Further, the correlations between the ZAC in each zone and the LCEA were analyzed using Pearson's correlation coefficient. RESULTS: One-hundred fifteen hips were categorized as control (36 hips), borderline (32 hips), and dysplasia (47 hips). The mean anterocranial ZAC in the borderline (87.5 ± 5.7°) was smaller than that in the control (92.6 ± 5.9°, P = .005) but did not differ compared with the dysplasia (84.5 ± 7.6°, P = .131). In contrast, the anterocaudal (71.2 ± 5.0°), posterocranial (85.0 ± 6.4°), and posterocaudal (82.4 ± 4.5°) mean ZACs in the borderline were not different from those in the control (anterocaudal, 74.3 ± 4.6°, P = .090; posterocranial, 87.9 ± 4.3°, P = .082; posterocaudal, 85.1 ± 5.0°, P = .069) respectively. Although there was a very strong positive correlation with supra-anterior ZAC and LCEA (r = 0.750, P < .001), the correlation between the anterocranial ZAC and LCEA was relatively weak (r = 0.574, P < .001). CONCLUSIONS: The anterosuperior acetabular coverage in the borderline dysplastic acetabulum is more similar to the dysplastic acetabulum than to the normal acetabulum. CLINICAL RELEVANCE: This study emphasizes the importance of evaluating not only the lateral but also the anterior coverage in borderline dysplasia.


Subject(s)
Acetabulum/diagnostic imaging , Acetabulum/surgery , Hip Dislocation/diagnostic imaging , Hip Dislocation/surgery , Adolescent , Adult , Female , Femur Head/diagnostic imaging , Femur Head/surgery , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Middle Aged , Osteotomy , Retrospective Studies , Tomography, X-Ray Computed , Young Adult
4.
PLoS One ; 15(4): e0231001, 2020.
Article in English | MEDLINE | ID: mdl-32251468

ABSTRACT

Whether borderline hip dysplasia is pathologic remains unclear. In order to evaluate the three-dimensional joint congruity, this study sought to answer the question: are borderline dysplastic hip curvature mismatch and eccentricity between the acetabulum and the femoral head different from dysplastic or control hips three-dimensionally? The 113 hips, categorized as: dysplastic (LCEA ≤ 20°), 47 hips; borderline (20° ≤ LCEA < 25°), 32 hips; and control (25° ≤ LCEA < 35°), 34 hips; were evaluated. Three-dimensional (3D) femoral and coxal bone models were reconstructed from CT images. Using a custom-written Visual C++ routine, the femoral head and acetabular radii of curvature, and the femoral head and the acetabular curvature center were calculated. Then the ratio of the acetabular radius to the femoral head radius (3D curvature mismatch ratio), and the distance between the acetabular curvature center and the femoral head center (3D center discrepancy distance) were calculated. These indices were compared statistically among the three groups using Tukey's post hoc test. The mean 3D curvature mismatch ratio in the borderline (1.13 ± 0.05) was smaller than in the dysplasia (1.23 ± 0.08, p < 0.001), and larger than in the control (1.07 ± 0.02, p < 0.001). The mean 3D center discrepancy distance in the borderline (3.2 ± 1.4 mm) was smaller than in the dysplasia (4.8 ± 2.3, p < 0.001) and larger than in the control (1.6 ± 0.7, p < 0.001). These results demonstrated that three-dimensional congruity of the borderline dysplastic hip is impaired, but its incongruity is not as severe as in dysplastic hips. The 3D curvature mismatch ratio and the 3D center discrepancy distance can be valuable signs of joint congruity in patients with borderline dysplasia. However, future studies are necessary to clarify any associations between curvature mismatch and pathogenesis of osteoarthritis in borderline dysplasia.


Subject(s)
Acetabulum/pathology , Femur Head/pathology , Hip Dislocation/pathology , Acetabulum/diagnostic imaging , Adolescent , Adult , Case-Control Studies , Female , Femur Head/diagnostic imaging , Hip Dislocation/diagnosis , Hip Dislocation/diagnostic imaging , Hip Dislocation/surgery , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Middle Aged , Radiography , Tomography, X-Ray Computed , Young Adult
5.
J Orthop Res ; 38(10): 2197-2205, 2020 10.
Article in English | MEDLINE | ID: mdl-32073168

ABSTRACT

In theory, a hemispherical acetabulum provides the ideal hip congruity in any hip position. However, it remains unknown how the three-dimensional acetabular morphology of borderline dysplastic and frank dysplastic hips compare to normal hips. This study inquires if borderline dysplastic zonal-acetabular curvatures in the anterior, superior, and posterior zones are different from normal or dysplastic hips three-dimensionally. One-hundred and fifteen hips, grouped as control (25°≤ LCEA <40°), 36 hips; borderline (20°≤ LCEA <25°), 32 hips; dysplasia (LCEA ≤20°), 47 hips were analyzed. The radii of acetabular curvature for the anterior, superior, and posterior zones were calculated as the zonal-acetabular radius of curvature (ZARC). The mean acetabular roof obliquity of the borderline (10.6 ± 4.3 [SD]°) was significantly larger than the control (3.0° ± 5.4°; P < .001) and smaller than the dysplasia (19.3° ± 5.7°; P < .001). Although the mean acetabular anteversion angle of the borderline (21.3° ± 3.7°) was significantly larger than control (17.9 ± 3.5°; P = .001), that of the borderline was not different from the dysplasia (23.3° ± 4.0°; P = .053). The mean anterior ZARC in the borderline (29.8 ± 2.6 mm) was significantly larger than the control (28.0 ± 2.2 mm; P = .011) and smaller than the dysplasia (31.5 ± 2.7 mm; P = .009). The mean superior ZARC in the borderline (25.7 ± 3.0 mm) was not different from the control (25.9 ± 2.2 mm; P = .934) or the dysplasia (25.8 ± 2.5 mm; P = .991). Although the mean posterior ZARC in the borderline (27.2 ± 2.5 mm) was not different from the control (26.4 ± 1.9 mm; P = .455), that of the borderline group was significantly smaller than the dysplasia (30.4 ± 3.3 mm; P < .001); that is, the severity of lateral under-coverage affects the anterior and/or posterior zonal-acetabular curvature.


Subject(s)
Acetabulum/diagnostic imaging , Hip Dislocation/diagnostic imaging , Acetabulum/pathology , Adolescent , Adult , Case-Control Studies , Female , Hip Dislocation/pathology , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Tomography, Spiral Computed , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL