Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38509402

ABSTRACT

BACKGROUND: Roughly one in six patients receiving conventional transvenous pacemaker systems experience significant complications within 1 year of implant, mainly due to the transvenous lead and subcutaneous pocket. A new helix-fixation single-chamber ventricular leadless pacemaker (LP) system capable of pre-deployment exploratory electrical mapping is commercially available. Such an LP may mitigate complications while streamlining the implantation. In this study, the initial real-world implant experience of the helix-fixation LP was evaluated following its commercial release. METHODS: In patients indicated for single-chamber right ventricular pacing, helix-fixation Aveir VR LPs (Abbott, Abbott Park, IL) were implanted using the dedicated loading tool, introducer, and delivery catheter. Implant procedural characteristics, electrical parameters, and any 30-day procedure-related adverse events of consecutive implant attempts were retrospectively evaluated. RESULTS: A total of 167 patients with Class I indication for permanent pacing received implants in four North American centers (57% male, 70 years old). Pre-fixation electrical mapping of potential sites allowed repositioning to be avoided in 95.7% of patients. Median [interquartile range] LP procedure and fluoroscopy durations were 25.5 min [20.0, 35.0] and 5.7 min [4.0, 9.2], respectively. Pacing capture threshold, sensed R-wave amplitude, and impedance were 0.8 V [0.5, 1.3], 9.0 mV [6.0, 12.0], and 705 Ω [550, 910], respectively. Implantation was successful in 98.8% of patients, with 98.2% free from acute adverse events. CONCLUSIONS: The initial, real-world experience of the helix-fixation ventricular leadless pacemaker demonstrated safe and efficient implantation with minimal repositioning, viable electrical metrics, and limited acute complications.

2.
J Pak Med Assoc ; 57(3): 159-62, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17432028

ABSTRACT

OBJECTIVE: To assess the frequency of depression among hospitalized patients, the socio-demographic variables associated with depression and the number of cases referred by physicians to Psychiatry. METHODS: A cross-sectional study was carried out at the Aga Khan University Hospital Karachi. An anonymous Urdu version of the WHO-developed self-reporting questionnaire (SRQ) was administered to inpatients meeting the inclusion criteria. Data was analyzed by SPSS version 13.0. RESULT: Of the 225 patients approached, 178 completed the questionnaire (men= 45.2%, women = 54.8%). The mean age of the sample was 45.2 years. Out of the total 30.5% of patients were identified as having probable depression, among which housewives were more likely to be depressed compared to others (p=0.031). Among variable comparison, there with secondary school education or below and those with psychiatric co-morbidities, showed significantly greater prevalence of depression (p=0.003) and (p=0.005) respectively. Attending physicians correctly diagnosed 7 (13%) patients and referred only 3 patients to Psychiatry over the previous month. CONCLUSION: The prevalence of depression among inpatients is comparable to that in the general population. Being a housewife, level at or below secondary school education and having a past psychiatric history are significant factors associated with depression in medical inpatients. A very small number of depressed cases were referred to a psychiatrist.


Subject(s)
Depression/epidemiology , Inpatients , Psychiatry/methods , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Pakistan/epidemiology , Prevalence , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...