Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ann N Y Acad Sci ; 1531(1): 49-59, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38084081

ABSTRACT

This study aimed to examine the impact of diabetes and hypertension on retinal nerve fiber layer (RNFL) thickness components. Optical coherence tomography (OCT) measurements do not consider blood vessel contribution, which this study addressed. We hypothesized that diabetes and/or hypertension would lead to thinner RNFL versus controls due to the vascular component. OCT angiography was used to measure the RNFL in 121 controls, 50 diabetes patients, 371 hypertension patients, and 177 diabetes patients with hypertension. A novel technique separated the RNFL thickness into original (vascular component) and corrected (no vascular component) measurements. Diabetes-only (98 ± 1.7 µm; p = 0.002) and diabetes with hypertension (99 ± 0.8 µm; p = 0.001) patients had thinner original RNFL versus controls (102 ± 0.8 µm). No difference was seen between hypertension-only patients (101 ± 0.5 µm; p = 0.083) and controls. After removing the blood vessel component, diabetes/hypertension groups had thinner corrected RNFL versus controls (p = 0.024). Discrepancies in diabetes/hypertension patients were due to thicker retinal blood vessels within the RNFL thickness (p = 0.002). Our findings suggest that diabetes and/or hypertension independently contribute to neurodegenerative thinning of the RNFL, even in the absence of retinopathy. The differentiation of neuronal and vascular components in RNFL thickness measurements provided by the novel technique highlights the importance of considering vascular changes in individuals with these conditions.


Subject(s)
Diabetes Mellitus , Hypertension , Retinal Diseases , Humans , Retinal Ganglion Cells , Nerve Fibers , Hypertension/complications , Tomography, Optical Coherence/methods
2.
Ann N Y Acad Sci ; 1529(1): 72-83, 2023 11.
Article in English | MEDLINE | ID: mdl-37656135

ABSTRACT

Data on how retinal structural and vascular parameters jointly influence the diagnostic performance of detection of multiple sclerosis (MS) patients without optic neuritis (MSNON) are lacking. To investigate the diagnostic performance of structural and vascular changes to detect MSNON from controls, we performed a cross-sectional study of 76 eyes from 51 MS participants and 117 eyes from 71 healthy controls. Retinal macular ganglion cell complex (GCC), retinal nerve fiber layer (RNFL) thicknesses, and capillary densities from the superficial (SCP) and deep capillary plexuses (DCP) were obtained from the Cirrus AngioPlex. The best structural parameter for detecting MS was compensated RNFL from the optic nerve head (AUC = 0.85), followed by GCC from the macula (AUC = 0.79), while the best vascular parameter was the SCP (AUC = 0.66). Combining structural and vascular parameters improved the diagnostic performance for MS detection (AUC = 0.90; p<0.001). Including both structure and vasculature in the joint model considerably improved the discrimination between MSNON and normal controls compared to each parameter separately (p = 0.027). Combining optical coherence tomography (OCT)-derived structural metrics and vascular measurements from optical coherence tomography angiography (OCTA) improved the detection of MSNON. Further studies may be warranted to evaluate the clinical utility of OCT and OCTA parameters in the prediction of disease progression.


Subject(s)
Multiple Sclerosis , Humans , Multiple Sclerosis/diagnostic imaging , Cross-Sectional Studies , Retina/diagnostic imaging , Retinal Ganglion Cells , Disease Progression , Tomography, Optical Coherence/methods
3.
PLoS One ; 14(1): e0210780, 2019.
Article in English | MEDLINE | ID: mdl-30699210

ABSTRACT

The expanded polytetrafluoroethylene (ePTFE) heart valve can serve as a viable option for prosthetic aortic valve. In this study, an ePTFE bi-leaflet valve design for aortic valve replacement (AVR) is presented, and the performance of the proposed valve was assessed numerically and experimentally. The valve was designed using CAE software. The dynamic behavior of the newly designed bi-leaflet valve under time-varying physiological pressure loading was first investigated by using commercial finite element code. Then, in-vitro tests were performed to validate the simulation and to assess the hemodynamic performance of the proposed design. A tri-leaflet ePTFE valve was tested in-vitro under the same conditions as a reference. The maximum leaflet coaptation area of the bi-leaflet valve during diastole was 216.3 mm2. When fully closed, no leakage gap was observed and the free edges of the molded valve formed S-shaped lines. The maximum Von Mises stress during a full cardiac cycle was 4.20 MPa. The dynamic performance of the bi-leaflet valve was validated by the in-vitro test under physiological aortic pressure pulse. The effective orifice area (EOA), mean pressure gradient, regurgitant volume, leakage volume and energy loss of the proposed valve were 3.14 cm2, 8.74 mmHg, 5.93 ml/beat, 1.55 ml/beat and 98.99 mJ, respectively. This study reports a novel bi-leaflet valve design for AVR. The performance of the proposed valve was numerically and experimentally assessed. Compared with the reference valve, the proposed design exhibited better structural and hemodynamic performances, which improved valve competency. Moreover, the performance of the bi-leaflet design is comparable to commercialized valves available on the market. The results of the present study provide a viable option for the future clinical applications.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Arterial Pressure , Computer Simulation , Computer-Aided Design , Coronary Circulation , Finite Element Analysis , Hemodynamics , Humans , Imaging, Three-Dimensional , In Vitro Techniques , Models, Cardiovascular , Polytetrafluoroethylene , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...