Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMJ Innov ; 7(2): 261-270, 2021 Apr.
Article in English | MEDLINE | ID: mdl-34192015

ABSTRACT

OBJECTIVES: There exists a wide gap in the availability of mechanical ventilator devices and their acute need in the context of the COVID-19 pandemic. An initial triaging method that accurately identifies the need for mechanical ventilation in hospitalised patients with COVID-19 is needed. We aimed to investigate if a potentially deteriorating clinical course in hospitalised patients with COVID-19 can be detected using all X-ray images taken during hospitalisation. METHODS: We exploited the well-established DenseNet121 deep learning architecture for this purpose on 663 X-ray images acquired from 528 hospitalised patients with COVID-19. Two Pulmonary and Critical Care experts blindly and independently evaluated the same X-ray images for the purpose of validation. RESULTS: We found that our deep learning model predicted the need for mechanical ventilation with a high accuracy, sensitivity and specificity (90.06%, 86.34% and 84.38%, respectively). This prediction was done approximately 3 days ahead of the actual intubation event. Our model also outperformed two Pulmonary and Critical Care experts who evaluated the same X-ray images and provided an incremental accuracy of 7.24%-13.25%. CONCLUSIONS: Our deep learning model accurately predicted the need for mechanical ventilation early during hospitalisation of patients with COVID-19. Until effective preventive or treatment measures become widely available for patients with COVID-19, prognostic stratification as provided by our model is likely to be highly valuable.

2.
JAMA Netw Open ; 4(5): e2111176, 2021 05 03.
Article in English | MEDLINE | ID: mdl-34028548

ABSTRACT

Importance: Interstitial fibrosis and tubular atrophy (IFTA) is a strong indicator of decline in kidney function and is measured using histopathological assessment of kidney biopsy core. At present, a noninvasive test to assess IFTA is not available. Objective: To develop and validate a deep learning (DL) algorithm to quantify IFTA from kidney ultrasonography images. Design, Setting, and Participants: This was a single-center diagnostic study of consecutive patients who underwent native kidney biopsy at John H. Stroger Jr. Hospital of Cook County, Chicago, Illinois, between January 1, 2014, and December 31, 2018. A DL algorithm was trained, validated, and tested to classify IFTA from kidney ultrasonography images. Of 6135 Crimmins-filtered ultrasonography images, 5523 were used for training (5122 images) and validation (401 images), and 612 were used to test the accuracy of the DL system. Kidney segmentation was performed using the UNet architecture, and classification was performed using a convolution neural network-based feature extractor and extreme gradient boosting. IFTA scored by a nephropathologist on trichrome stained kidney biopsy slide was used as the reference standard. IFTA was divided into 4 grades (grade 1, 0%-24%; grade 2, 25%-49%; grade 3, 50%-74%; and grade 4, 75%-100%). Data analysis was performed from December 2019 to May 2020. Main Outcomes and Measures: Prediction of IFTA grade was measured using the metrics precision, recall, accuracy, and F1 score. Results: This study included 352 patients (mean [SD] age 47.43 [14.37] years), of whom 193 (54.82%) were women. There were 159 patients with IFTA grade 1 (2701 ultrasonography images), 74 patients with IFTA grade 2 (1239 ultrasonography images), 41 patients with IFTA grade 3 (701 ultrasonography images), and 78 patients with IFTA grade 4 (1494 ultrasonography images). Kidney ultrasonography images were segmented with 91% accuracy. In the independent test set, the point estimates for performance matrices showed precision of 0.8927 (95% CI, 0.8682-0.9172), recall of 0.8037 (95% CI, 0.7722-0.8352), accuracy of 0.8675 (95% CI, 0.8406-0.8944), and an F1 score of 0.8389 (95% CI, 0.8098-0.8680) at the image level. Corresponding estimates at the patient level were precision of 0.9003 (95% CI, 0.8644-0.9362), recall of 0.8421 (95% CI, 0.7984-0.8858), accuracy of 0.8955 (95% CI, 0.8589-0.9321), and an F1 score of 0.8639 (95% CI, 0.8228-0.9049). Accuracy at the patient level was highest for IFTA grade 1 and IFTA grade 4. The accuracy (approximately 90%) remained high irrespective of the timing of ultrasonography studies and the biopsy diagnosis. The predictive performance of the DL system did not show significant improvement when combined with baseline clinical characteristics. Conclusions and Relevance: These findings suggest that a DL algorithm can accurately and independently predict IFTA from kidney ultrasonography images.


Subject(s)
Algorithms , Biopsy/standards , Deep Learning , Fibrosis/diagnostic imaging , Image Interpretation, Computer-Assisted/standards , Kidney Diseases/diagnostic imaging , Ultrasonography/standards , Adult , Chicago , Female , Fibrosis/physiopathology , Humans , Kidney Diseases/complications , Kidney Diseases/physiopathology , Male , Middle Aged , Practice Guidelines as Topic/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...