1.
Talanta ; 278: 126509, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39003839

ABSTRACT

Bipolar electrochemical microscopy (BEM), which visualizes the concentration distribution of molecular species in biological systems by electrochemiluminescence (ECL), is expected to be applied to the high-spatiotemporal-resolution imaging of biomolecules, enabling the analysis of cellular functions. In the past, the molecular species that could be imaged by BEM were generally restricted to oxidized molecules due to the limitation derived from the ECL mechanism of the luminophore. Recently, the imaging of dopamine (DA), a reduced molecule, was achieved using Ru (bpy)32+/glutathione disulfide (GSSG) as a cathodic luminophore. However, a large driving voltage was required for ECL generation, resulting in a low S/N ratio. In this study, we employed N,N'-dimethyl-3,4,9,10-perylenetetracarboxylic diimide (PDI-CH3)/potassium peroxodisulfate (K2S2O8), which is a cathodic luminophore that can be reduced at a nobler potential to produce ECL than [Ru(bpy)3]2+/GSSG. First, the ECL mechanism of PDI-CH3/K2S2O8 was elucidated by using a PDI-CH3 drop-cast glassy carbon electrode (GCE) immersed in K2S2O8 solution as the working electrode in a 3-electrode system. The PDI-CH3 drop-casted GCE, a single closed bipolar electrode (c-BPE), was used as the cathode in the successful quantification of 50-500 µmol L-1 DA in a sample chamber in which a c-BPE anode was immersed, resulting in a high S/N. The selective detection of DA in the presence of ascorbic acid was achieved by modifying the anode with Nafion. Finally, DA imaging was demonstrated using a commercially available anisotropic conducting film with PDI-CH3 coating on the cathode surface as a c-BPE array. The change in the concentration distribution in the inflow of DA was successfully imaged based on the change in the ECL intensity at the c-BPE cathode. This BEM system is expected to be useful for DA imaging of the brain.


Subject(s)
Dopamine , Electrochemical Techniques , Electrodes , Imides , Perylene , Dopamine/analysis , Dopamine/chemistry , Perylene/chemistry , Perylene/analogs & derivatives , Imides/chemistry , Electrochemical Techniques/methods , Luminescent Measurements/methods , Sulfates/chemistry , Sulfates/analysis , Potassium Compounds
2.
Anal Chem ; 94(25): 8857-8866, 2022 06 28.
Article in English | MEDLINE | ID: mdl-35700401

ABSTRACT

In this study, a carbon paste filling method was proposed as a simple strategy for fabricating high-density bipolar electrode (BPE) arrays for bipolar electrochemical microscopy (BEM). High spatiotemporal resolution imaging was achieved using the fabricated BPE array. BEM, which is an emerging microscopic system in recent years, achieves label-free and high spatiotemporal resolution imaging of molecular distributions using high-density BPE arrays and electrochemiluminescence (ECL) signals. We devised a simple method to fabricate a BPE array by filling a porous plate with carbon paste and succeeded in fabricating a high-density BPE array (15 µm pitch). After a detailed observation of the surface of the BPE array using a scanning electron microscope, the basic electrochemical and ECL emission characteristics were evaluated using potassium ferricyanide solution as a sample solution. Moreover, inflow imaging of the sample molecules was conducted to evaluate the imaging ability of the prepared BPE array. In addition, Prussian Blue containing carbon ink was applied to the sample solution side of the BPE array to provide catalytic activity to hydrogen peroxide, and the quantification and inflow imaging of hydrogen peroxide by ECL signals was achieved. This simple fabrication method of the BPE array can accelerate the research and development of BEM. Furthermore, hydrogen peroxide imaging by BEM is an important milestone for achieving bioimaging with high spatiotemporal resolution such as biomolecule imaging using enzymes.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Biosensing Techniques/methods , Carbon , Electrochemical Techniques/methods , Electrodes , Hydrogen Peroxide/chemistry , Luminescent Measurements/methods
3.
Analyst ; 145(21): 6895-6900, 2020 Oct 26.
Article in English | MEDLINE | ID: mdl-32820751

ABSTRACT

In this study, we developed bipolar electrochemical microscopy (BEM) using a closed bipolar electrode (cBPE) array with an electrochemiluminescence (ECL) detecting system. Because cBPEs are not directly connected to a detector, high spatio-temporal resolution imaging can be achieved by fabricating a microelectrode array in which each electrode point is arranged in a short interval. A cBPE array with individual cBPEs arranged in 41 µm intervals was successfully fabricated by depositing gold in the pores of a track-etched membrane using electroless plating. Using BEM with the cBPE array, which has a higher density of electrode points than the conventional multi-electrode array, we effectively demonstrated the imaging of [Fe(CN)6]3- diffusion and the respiratory activity of MCF-7 spheroids with high spatio-temporal resolution.

4.
Micromachines (Basel) ; 11(5)2020 May 22.
Article in English | MEDLINE | ID: mdl-32456040

ABSTRACT

Mammalian cell analysis is essential in the context of both fundamental studies and clinical applications. Among the various techniques available for cell analysis, electrochemiluminescence (ECL) has attracted significant attention due to its integration of both electrochemical and spectroscopic methods. In this review, we summarize recent advances in the ECL-based systems developed for mammalian cell analysis. The review begins with a summary of the developments in luminophores that opened the door to ECL applications for biological samples. Secondly, ECL-based imaging systems are introduced as an emerging technique to visualize single-cell morphologies and intracellular molecules. In the subsequent section, the ECL sensors developed in the past decade are summarized, the use of which made the highly sensitive detection of cell-derived molecules possible. Although ECL immunoassays are well developed in terms of commercial use, the sensing of biomolecules at a single-cell level remains a challenge. Emphasis is therefore placed on ECL sensors that directly detect cellular molecules from small portions of cells or even single cells. Finally, the development of bipolar electrode devices for ECL cell assays is introduced. To conclude, the direction of research in this field and its application prospects are described.