Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JMIR Perioper Med ; 6: e40474, 2023 Feb 20.
Article in English | MEDLINE | ID: mdl-36804173

ABSTRACT

BACKGROUND: Postoperative deterioration is often preceded by abnormal vital parameters. Therefore, vital parameters of postoperative patients are routinely measured by nursing staff. Wrist-worn sensors could potentially provide an alternative tool for the measurement of vital parameters in low-acuity settings. These devices would allow more frequent or even continuous measurements of vital parameters without relying on time-consuming manual measurements, provided their accuracy in this clinical population is established. OBJECTIVE: This study aimed to assess the accuracy of heart rate (HR) and respiratory rate (RR) measures obtained via a wearable photoplethysmography (PPG) wristband in a cohort of postoperative patients. METHODS: The accuracy of the wrist-worn PPG sensor was assessed in 62 post-abdominal surgery patients (mean age 55, SD 15 years; median BMI 34, IQR 25-40 kg/m2). The wearable obtained HR and RR measurements were compared to those of the reference monitor in the postanesthesia or intensive care unit. Bland-Altman and Clarke error grid analyses were performed to determine agreement and clinical accuracy. RESULTS: Data were collected for a median of 1.2 hours per patient. With a coverage of 94% for HR and 34% for RR, the device was able to provide accurate measurements for the large majority of the measurements as 98% and 93% of the measurements were within 5 bpm or 3 rpm of the reference signal. Additionally, 100% of the HR and 98% of the RR measurements were clinically acceptable on Clarke error grid analysis. CONCLUSIONS: The wrist-worn PPG device is able to provide measurements of HR and RR that can be seen as sufficiently accurate for clinical applications. Considering the coverage, the device was able to continuously monitor HR and report RR when measurements of sufficient quality were obtained. TRIAL REGISTRATION: ClinicalTrials.gov NCT03923127; https://www.clinicaltrials.gov/ct2/show/NCT03923127.

2.
Sleep Med ; 100: 573-576, 2022 12.
Article in English | MEDLINE | ID: mdl-36327586

ABSTRACT

Previous research has shown an interplay between the thalamus and cerebral cortex during NREM sleep in humans, however the directionality of the thalamocortical synchronization is as yet unknown. In this study thalamocortical connectivity during different NREM sleep stages using sleep scalp electroencephalograms and local field potentials from the left and right anterior thalamus was measured in three epilepsy patients implanted with deep brain stimulation electrodes. Connectivity was assessed as debiased weighted phase lag index and granger causality between the thalamus and cortex for the NREM sleep stages N1, N2 and N3. Results showed connectivity was most prominently directed from cortex to thalamus. Moreover, connectivity varied in strength between the different sleep stages, but barely in direction or frequency. These results imply relatively stable thalamocortical connectivity during NREM sleep directed from the cortex to the thalamus.


Subject(s)
Deep Brain Stimulation , Humans , Deep Brain Stimulation/methods , Sleep Stages/physiology , Electroencephalography/methods , Thalamus , Cerebral Cortex/physiology , Sleep/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...