Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Med ; 2024 Mar 12.
Article in English | MEDLINE | ID: mdl-38469893

ABSTRACT

PURPOSE: Ultrahigh field (≥7 T) MRI is at the cutting edge of medical imaging, enabling enhanced spatial and spectral resolution as well as enhanced susceptibility contrast. However, transmit ( B 1 + $$ {\mathrm{B}}_1^{+} $$ ) field inhomogeneity due to standing wave effects caused by the shortened RF wavelengths at 7 T is still a challenge to overcome. Novel hardware methods such as dielectric pads have been shown to improve the B 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneity but are currently limited in their corrective effect by the range of high-permittivity materials available and have a fixed shelf life. In this work, an optimized metasurface design is presented that demonstrates in vivo enhancement of the B 1 + $$ {\mathrm{B}}_1^{+} $$ field. METHODS: A prototype metasurface was optimized by an empirical capacitor sweep and by varying the period size. Phantom temperature experiments were performed to evaluate potential metasurface heating effects during scanning. Lastly, in vivo gradient echo images and B 1 + $$ {\mathrm{B}}_1^{+} $$ maps were acquired on five healthy subjects on a 7 T system. Dielectric pads were also used as a comparison throughout the work as a standard comparison. RESULTS: The metasurfaces presented here enhanced the average relative SNR of the gradient echo images by a factor of 2.26 compared to the dielectric pads factor of 1.61. Average B 1 + $$ {\mathrm{B}}_1^{+} $$ values reflected a similar enhancement of 27.6% with the metasurfaces present versus 8.9% with the dielectric pads. CONCLUSION: The results demonstrate that metasurfaces provide superior performance to dielectric padding as shown by B 1 + $$ {\mathrm{B}}_1^{+} $$ maps reflecting their direct effects and resulting enhancements in image SNR at 7 T.

2.
PLoS One ; 19(2): e0297310, 2024.
Article in English | MEDLINE | ID: mdl-38363747

ABSTRACT

INTRODUCTION: With nicotine dependence being a significant healthcare issue worldwide there is a growing interest in developing novel therapies and diagnostic aids to assist in treating nicotine addiction. Glutamate (Glu) plays an important role in cognitive function regulation in a wide range of conditions including traumatic brain injury, aging, and addiction. Chemical exchange saturation transfer (CEST) imaging via ultra-high field MRI can image the exchange of certain saturated labile protons with the surrounding bulk water pool, making the technique a novel tool to investigate glutamate in the context of addiction. The aim of this work was to apply glutamate weighted CEST (GluCEST) imaging to study the dorsal anterior cingulate cortex (dACC) in a small population of smokers and non-smokers to determine its effectiveness as a biomarker of nicotine use. METHODS: 2D GluCEST images were acquired on 20 healthy participants: 10 smokers (ages 29-50) and 10 non-smokers (ages 25-69), using a 7T MRI system. T1-weighted images were used to segment the GluCEST images into white and gray matter tissue and further into seven gray matter regions. Wilcoxon rank-sum tests were performed, comparing mean GluCEST contrast between smokers and non-smokers across brain regions. RESULTS: GluCEST levels were similar between smokers and non-smokers; however, there was a moderate negative age dependence (R2 = 0.531) in smokers within the cingulate gyrus. CONCLUSION: Feasibility of GluCEST imaging was demonstrated for in vivo investigation of smokers and non-smokers to assess glutamate contrast differences as a potential biomarker with a moderate negative age correlation in the cingulate gyrus suggesting reward network involvement.


Subject(s)
Glutamic Acid , Nicotine , Humans , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Neuroimaging , Biomarkers
3.
NMR Biomed ; 37(4): e5094, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38214202

ABSTRACT

We present a review outlining the basic mechanism, background, recent technical developments, and clinical applications of aqueous dielectric padding in the field of MRI. Originally meant to be a temporary solution, it has gained traction as an effective method for correcting B1 + inhomogeneities due to the unique properties of the calcium titanate and barium titanate perovskites used. Aqueous dielectric pads have used a variety of high-permittivity materials over the years to improve the quality of MRI acquisitions at 1.5 and 3 T and more recently for 7 T neuroimaging applications. The technical development and assessment of these pads have been advanced by an increased use of mathematical modeling and electromagnetic simulations. These tools have allowed for a more complete understanding of the physical interactions between dielectric pads and the RF coil, making testing and safety assessments more accurate. The ease of use and effectiveness that dielectric pads offer have allowed them to become more commonplace in tackling imaging challenges in more clinically focused environments. More recently, they have seen usage not only in anatomical imaging methods but also in specialized metabolic imaging sequences such as GluCEST and NOEMTR . New colossally high-permittivity materials have been proposed; however, practical utilization has been a continued challenge due to unfavorable frequency dependences as well as safety limitations. A new class of metasurfaces has been under development to address the shortcomings of conventional dielectric padding while also providing increased performance in enhancing MRI images.


Subject(s)
Magnetic Resonance Imaging , Neuroimaging , Magnetic Resonance Imaging/methods , Neuroimaging/methods , Water , Radio Waves , Magnetic Resonance Spectroscopy , Phantoms, Imaging
4.
Magn Reson Med ; 90(4): 1537-1546, 2023 10.
Article in English | MEDLINE | ID: mdl-37279010

ABSTRACT

PURPOSE: Nuclear Overhauser effect magnetization transfer ratio (NOEMTR ) is a technique used to investigate brain lipids and macromolecules in greater detail than other techniques and benefits from increased contrast at 7 T. However, this contrast can become degraded because of B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities present at ultra-high field strengths. High-permittivity dielectric pads (DP) have been used to correct for these inhomogeneities via displacement currents generating secondary magnetic fields. The purpose of this work is to demonstrate that dielectric pads can be used to mitigate B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities and improve NOEMTR contrast in the temporal lobes at 7 T. METHODS: Partial 3D NOEMTR contrast images and whole brain B 1 + $$ {\mathrm{B}}_1^{+} $$ field maps were acquired on a 7 T MRI across six healthy subjects. Calcium titanate DP, having a relative permittivity of 110, was placed next to the subject's head near the temporal lobes. Pad corrected NOEMTR images had a separate postprocessing linear correction applied. RESULTS: DP provided supplemental B 1 + $$ {\mathrm{B}}_1^{+} $$ to the temporal lobes while also reducing the B 1 + $$ {\mathrm{B}}_1^{+} $$ magnitude across the posterior and superior regions of the brain. This resulted in a statistically significant increase in NOEMTR contrast in substructures of the temporal lobes both with and without linear correction. The padding also produced a convergence in NOEMTR contrast toward approximately equal mean values. CONCLUSION: NOEMTR images showed significant improvement in temporal lobe contrast when DP were used, which resulted from an increase in B 1 + $$ {\mathrm{B}}_1^{+} $$ homogeneity across the entire brain slab. DP-derived improvements in NOEMTR are expected to increase the robustness of the brain substructural measures both in healthy and pathological conditions.


Subject(s)
Brain , Head , Humans , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Brain Mapping , Magnetic Fields , 5-Methyltetrahydrofolate-Homocysteine S-Methyltransferase
5.
Magn Reson Med ; 89(6): 2295-2304, 2023 06.
Article in English | MEDLINE | ID: mdl-36744726

ABSTRACT

PURPOSE: Nuclear Overhauser effect (NOE) is based on dipolar cross-relaxation mechanism that enables the indirect detection of aliphatic protons via the water proton signal. This work focuses on determining the reproducibility of NOE magnetization transfer ratio (NOEMTR ) and isolated or relayed NOE (rNOE) contributions to the NOE MRI of the healthy human brain at 7 Tesla (T). METHODS: We optimized the B 1 + $$ {\mathrm{B}}_1^{+} $$ amplitude and length of the saturation pulse by acquiring NOE images with different B 1 + $$ {\mathrm{B}}_1^{+} $$ values with multiple saturation lengths. Repeated NOE MRI measurements were made on five healthy volunteers by using optimized saturation pulse parameters including correction of B0 and B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities. To isolate the individual contributions from z-spectra, we have fit the NOE z-spectra using multiple Lorentzians and calculated the total contribution from each pool contributing to the overall NOEMTR contrast. RESULTS: We found that a saturation amplitude of 0.72 µT and a length of 3 s provided the highest contrast. We found that the mean NOEMTR value in gray matter (GM) was 26%, and in white matter (WM) was 33.3% across the 3D slab of the brain. The mean rNOE contributions from GM and WM values were 8.9% and 9.6%, which were ∼10% of the corresponding total NOEMTR signal. The intersubject coefficient of variations (CoVs) of NOEMTR from GM and WM were 4.5% and 6.5%, respectively, whereas the CoVs of rNOE were 4.8% and 5.6%, respectively. The intrasubject CoVs of the NOEMTR range was 2.1%-4.2%, and rNOE range was 2.9%-10.5%. CONCLUSION: This work has demonstrated an excellent reproducibility of both inter- and intrasubject NOEMTR and rNOE metrics in healthy human brains at 7 T.


Subject(s)
Algorithms , Brain Neoplasms , Humans , Reproducibility of Results , Image Interpretation, Computer-Assisted/methods , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Protons
6.
Magn Reson Med ; 88(6): 2475-2484, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36178233

ABSTRACT

PURPOSE: Ultra-high field MR imaging lacks B1 + inhomogeneity due to shorter RF wavelengths used at higher field strengths compared to human anatomy. CEST techniques tend to be highly susceptible to B1 + inhomogeneities due to a high and uniform B1 + field being necessary to create the endogenous contrast. High-permittivity dielectric pads have seen increasing usage in MR imaging due to their ability to tailor the spatial distribution of the B1 + field produced. The purpose of this work is to demonstrate that dielectric materials can be used to improve glutamate weighted CEST (gluCEST) at 7T. THEORY AND METHODS: GluCEST images were acquired on a 7T system on six healthy volunteers. Aqueous calcium titanate pads, with a permittivity of approximately 110, were placed on either side in the subject's head near the temporal lobes. A post-processing correction algorithm was implemented in combination with dielectric padding to compare contrast improvement. Tissue segmentation was performed to assess the effect of dielectric pads on gray and white matter separately. RESULTS: GluCEST images demonstrated contrast enhancement in the lateral temporal lobe regions with dielectric pad placement. Tissue segmentation analysis showed an increase in correction effectiveness within the gray matter tissue compared to white matter tissue. Statistical testing suggested a significant difference in gluCEST contrast when pads were used and showed a difference in the gray matter tissue segment. CONCLUSION: The use of dielectric pads improved the B1 + field homogeneity and enhanced gluCEST contrast for all subjects when compared to data that did not incorporate padding.


Subject(s)
Glutamic Acid , White Matter , Algorithms , Gray Matter , Humans , Magnetic Resonance Imaging/methods
7.
Med Phys ; 48(2): 781-790, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33294999

ABSTRACT

PURPOSE: A 7T magnetic resonance thermometry (MRT) technique was developed to validate the conversion factor between the system-measured transmitted radiofrequency (RF) power into a home-built RF wrist coil with the system-predicted SAR value. The conversion factor for a new RF coil developed for ultra high magnetic field MRI systems is used to ensure that regulatory limits on RF energy deposition in tissue, specifically the local 10g-averaged specific absorption rate (SAR10g ), are not exceeded. MRT can be used to validate this factor by ensuring that MRT-measured SAR values do not exceed those predicted by the system. METHODS: A 14-cm diameter high-pass birdcage RF coil was built to image the wrist at 7T. A high spatial and temporal resolution dual-echo gradient echo MRT technique, incorporating quasi-simultaneous RF-induced heating and temperature change measurements using the proton resonance frequency method, was developed. The technique allowed for high-temperature resolution measurements (~±0.1°C) to be performed every 20 s over a 4-min heating period, with high spatial resolution (2.56 mm3 voxel size) and avoiding phase discontinuities arising from severe magnetic susceptibility-induced B0 inhomogeneities. Magnetic resonance thermometry was performed on a phantom made from polyvinylpyrrolidone to mimic the dielectric properties of muscle tissue at 297.2 MHz. Temperature changes measured with MRT and four fiber optic temperature sensors embedded in the phantom were compared. Electromagnetic simulations of the coil and phantom were developed and validated via comparison of simulated and measured B1 + maps in the phantom. The position of maximum SAR within the coil was determined from simulations, and MRT was performed within a wrist-sized piece of meat positioned at that SAR hotspot location. MRT-measured and system-predicted SAR values for the phantom and meat were compared. RESULTS: Temperature change measurements from MRT matched closely to those from the fiber optic temperature sensors. The simulations were validated via close correlation between the simulated and MRT-measured B1 + and SAR maps. Using a coil conversion factor of 2 kg-1 , MRT-measured point-SAR values did not exceed the system-predicted SAR10g in either the uniform phantom or in the piece of meat mimicking the wrist located at the SAR hotspot location. CONCLUSIONS: A highly accurate MRT technique with high spatial and temporal resolution was developed. This technique can be used to ensure that system-predicted SAR values are not exceeded in practice, thereby providing independent validation of SAR levels delivered by a newly built RF wrist coil. The MRT technique is readily generalizable to perform safety evaluations for other RF coils at 7T.


Subject(s)
Thermometry , Wrist , Magnetic Resonance Imaging , Phantoms, Imaging , Radio Waves , Wrist/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...